• Title/Summary/Keyword: Power Distribution Systems

Search Result 1,310, Processing Time 0.03 seconds

Optimal installation of electric vehicle charging stations connected with rooftop photovoltaic (PV) systems: a case study

  • Heo, Jae;Chang, Soowon
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.937-944
    • /
    • 2022
  • Electric vehicles (EVs) have been growing to reduce energy consumption and greenhouse gas (GHG) emissions in the transportation sector. The increasing number of EVs requires adequate recharging infrastructure, and at the same time, adopts low- or zero-emission electricity production because the GHG emissions are highly dependent on primary sources of electricity production. Although previous research has studied solar photovoltaic (PV) -integrated EV charging stations, it is challenging to optimize spatial areas between where the charging stations are required and where the renewable energy sources (i.e., solar photovoltaic (PV)) are accessible. Therefore, the primary objective of this research is to support decisions of siting EV charging stations using a spatial data clustering method integrated with Geographic Information System (GIS). This research explores spatial relationships of PV power outputs (i.e., supply) and traffic flow (i.e., demand) and tests a community in the state of Indiana, USA for optimal sitting of EV charging stations. Under the assumption that EV charging stations should be placed where the potential electricity production and traffic flow are high to match supply and demand, this research identified three areas for installing EV charging stations powered by rooftop PV in the study area. The proposed strategies will drive the transition of existing energy infrastructure into decentralized power systems. This research will ultimately contribute to enhancing economic efficiency and environmental sustainability by enabling significant reductions in electricity distribution loss and GHG emissions driven by transportation energy.

  • PDF

Channel characteristics of multi-path power line using a contactless inductive coupling unit (비접촉식 유도성 결합기를 이용한 다중경로 전력선 채널 특성)

  • Kim, Hyun-Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.799-804
    • /
    • 2016
  • Broadband powerline communication (BPLC) uses distribution lines as a medium for achieving effective bidirectional data communication along with electric current flow. As the material characteristics of power lines are not good at the communication channel, the development of power line communication (PLC) systems for internet, voice, and data services requires measurement-based models of the transfer characteristics of the network suitable for performance analysis by simulation. In this paper, an analytic model describing a complex transfer function is presented to obtain the attenuation and path parameters for a multipath power line model. The calculated results demonstrated frequency-selective fading in multipath channels and signal attenuation with frequency, and were in good agreement with the experimental results. Inductive coupling units are used as couplers for coupling the signal to the power line to avoid physical connections to the distribution line. The inductance of the ferrite core, which depends on the frequency, determines the cut-off frequency of the inductive coupler. Coupling loss can be minimized by increasing the number of windings around the coupler. Coupling efficiency was improved by more than 6 dB with three windings compared to the results obtained with one winding.

Reducing Test Power and Improving Test Effectiveness for Logic BIST

  • Wang, Weizheng;Cai, Shuo;Xiang, Lingyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.640-648
    • /
    • 2014
  • Excessive power dissipation is one of the major issues in the testing of VLSI systems. Many techniques are proposed for scan test, but there are not so many for logic BIST because of its unmanageable randomness. This paper presents a novel low switching activity BIST scheme that reduces toggle frequency in the majority of scan chain inputs while allowing a small portion of scan chains to receive pseudorandom test data. Reducing toggle frequency in the scan chain inputs can reduce test power but may result in fault coverage loss. Allowing a small portion of scan chains to receive pseudorandom test data can make better uniform distribution of 0 and 1 and improve test effectiveness significantly. When compared with existing methods, experimental results on larger benchmark circuits of ISCAS'89 show that the proposed strategy can not only reduce significantly switching activity in circuits under test but also achieve high fault coverage.

A Study on the Implementation of Automation Network for Power Utility using UCA and Fieldbus (UCA와 필드버스를 이용한 전력 설비 자동화 통신망 구축 방안 연구)

  • Choe, In-Ho;Hwang, In-Hwi;Hong, Seung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.6
    • /
    • pp.287-298
    • /
    • 2000
  • The UCA is a standard-based approach to utility communications which provides for wide scale integration of functional areas including customer interface, distribution, transmission, power plant, control center, and corporate information systems. Field devices in the power facilities require real-time communications, and they must be interconnected into fieldbus. This study introduces a method of implementing gateway that interfaces UCA and fieldbus. In this study, PROFIBUS and FOUNDATION Fieldbus are selected as candidate fieldbus protocols. Protocol interface in the gateway can be accomplished by mapping objects and services of UCA and fieldbus. MOst of the UCAs CASM objects and services are directly mapped into those of the application and user layers of fieldbus. However, some CASM services are not supported in the application and user layers of fieldbus. This study presents the method of implementing those services. In order to show that the implementation of interface is possible, this study presents pseudo-codes of interface program that maps the objects and services of UCA and fieldbus.

  • PDF

The Analysis of the interconnection Simulation Result for Dispersed Sources in Distribution Systems (배전계통에 있어서 분산전원 연계 판정 시뮬레이션 결과 분석에 관한 연구)

  • Kang, Min-Kwan;Park, Jae-Ho;Rho, Dae-Seok;Oh, Yong-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.90-92
    • /
    • 2006
  • 국가차원의 신 재생에너지 활성화 방안에 따라 지자체 등의 분산전원 시실계획이 점차 증가하고 있으나, 아직 우리나라에서는 분산전원의 배전계통 연계에 대한 체계적인 기술지침이 초기 단계에 있거나 제정 중에 있어서, 계통 연계와 관련하여 발전사업자와 전력회사간의 이해가 상충되는 등 문제점이 발생되고 있다. 또한, 대규모 분산전원 단지의 도입이 이루어지고 있으나, 이에 대한 기술적인 평가방안이나 해석 방법이 구체적으로 제시되어 있지 않아, 설치자(시도 및 지자체)와 운용자(한전의 배전지사/지점)들은 많은 혼돈과 어려움을 겪고 있는 실정이다. 따라서 본 논문에서는 태양광, 풍력 등의 분산전원이 배전계통에 도입되는 경우, 연계에 대한 기술적인적합여부를 종합적으로 평가 할 수 있도록 분산전원 연계판정 시뮬레이션 시스템을 연구하였다. 즉, 구체적으로는 전력용량, 전기방식, 역률, 뱅크 역 조류, 상시전압변동, 순시전압변동, 플리커, 단락용량, 연계가능용량 등이며, 이들 항목을 계통연계 가이드라인과 평가 알고리즘에 의하여 연계 적합 여부를 판단해 주는 시스템이다.

  • PDF

Wavelet-like convolutional neural network structure for time-series data classification

  • Park, Seungtae;Jeong, Haedong;Min, Hyungcheol;Lee, Hojin;Lee, Seungchul
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.175-183
    • /
    • 2018
  • Time-series data often contain one of the most valuable pieces of information in many fields including manufacturing. Because time-series data are relatively cheap to acquire, they (e.g., vibration signals) have become a crucial part of big data even in manufacturing shop floors. Recently, deep-learning models have shown state-of-art performance for analyzing big data because of their sophisticated structures and considerable computational power. Traditional models for a machinery-monitoring system have highly relied on features selected by human experts. In addition, the representational power of such models fails as the data distribution becomes complicated. On the other hand, deep-learning models automatically select highly abstracted features during the optimization process, and their representational power is better than that of traditional neural network models. However, the applicability of deep-learning models to the field of prognostics and health management (PHM) has not been well investigated yet. This study integrates the "residual fitting" mechanism inherently embedded in the wavelet transform into the convolutional neural network deep-learning structure. As a result, the architecture combines a signal smoother and classification procedures into a single model. Validation results from rotor vibration data demonstrate that our model outperforms all other off-the-shelf feature-based models.

Modeling of Power Quality Stabilization using SMES and DVR (SMES 와 DVR을 이용한 전력계통품질 안정화 시스템 모델링)

  • Park, Sung-Yeol;Jung, Hee-Yeol;Kim, A-Rong;Kim, Jae-Ho;Park, Min-Won;Yu, In-Keun;Kim, Seok-Ho;Kim, Hae-Jong;Seong, Ki-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2251-2252
    • /
    • 2008
  • Recently, voltage sag from sudden increasing loads is also one of the major problems inside the utility network. In order to compensate the voltage sag problem, power compensation device systems could be a good solution method. In case of voltage sag, an energy source is needed to overcome the energy loss caused by the voltage sag. Superconducting Magnetic Energy Storage (SMES) is a very promising source of this energy due to its fast response of charging and discharging time. Before constructing the power electronic delivering system for the SMES, it is necessary to simulate the system to understand its behavior. Nowadays, a lot of devices have been developed to compensate voltage sag such as Dynamic Voltage Restorer (DVR), Distribution Static Compensator (D-STATCOM) and Uninterruptible Power Supply (UPS). In this paper, focus is given only on DVR system which will be simulated by using PSCAD/EMTDC software.

  • PDF

Analysis of Characteristics of Residential Distribution Line for Design of Power Line Communication Systems (전력선 통신 시스템 설계를 위한 주택배선의 선로특성 분석)

  • Hong, Ducpyo;Choi, Jaeho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.99-104
    • /
    • 2005
  • This paper describes the measurement and analysis of the basic line constants in PLC(Power Line Communication) in the residential building. An apartment is considered as one of the conventional residences to get the line constants in this paper, Agilent 4263B LCR Meter is used to measure the detailed values each area and the specific results and averaged analysis data are shown in the tables. The measured results are a little bit different from the calculated values using conventional formula due to the line arrangement, neglected factors, complex permittivity, and etc. This paper describes many kinds of lines and wiring figures of domestic construction. It can be utilized with the analyzed line characteristics in frequency domain as a planning reference of PLC.

Quench Characteristics of YBCO Film for Current Limiting Using Magnetic Field

  • 박권배;최효상;김혜림;현옥배;황시돌
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.252-256
    • /
    • 2002
  • We studied YBCO films for current limiting of the resistive type which utilizes a transition from superconducting to normal state caused by exceeding critical current. The films were deposited on sapphire substrates and covered by gold top layer. The current limiting element consists of 2 mm wide YBCO stripes connected in series. A serious problem in using YBCO films for current limiting is inhomogeneities caused by imperfect manufacturing. Therefore simultaneous quench is a difficult problem when elements for current limiting are connected in series. So some researchers have recently proposed using magnetic field and heating for simultaneous quench. We have measured extended exec trim field-current density(E-J) characteristics for current limiting elements of YBCO films in applied magnetic field of 0 - 130 mT. And we have investigated quench characteristics in current limiting elements and between elements of YBCO films in applied magnetic field. The result of the experiments show that the presence of applied magnetic fields induces uniform quench distribution fur the stripes in element at $50V_{rms}$, otherwise non-uniform quenches were observed. And simultaneous quenches between elements were investigated at $150V_{rms}$. We suggest that suppressing the critical current by increased fields due to fault current effectively forced the stripes of higher $J_{c}$(0) to quench, resulting in equalizing quench times.s.s.s.

  • PDF

Transformerless Three-Level DC-DC Buck Converter with a High Step-Down Conversion Ratio

  • Zhang, Yun;Sun, Xing-Tao;Wang, Yi-Feng;Shao, Hong-Jun
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.70-76
    • /
    • 2013
  • For high power high step-down dc-dc conversion applications, conventional three-level dc-dc converters are subject to extreme duty cycles or increased volume and cost due to the use of transformers. In this paper, a transformerless three-level dc-dc buck converter with a high step-down conversion ratio is proposed. The converter comprises two asymmetrical half bridges, which are of the neutral point clamped structures. Therefore, the output pulse voltage of the converter can be obtained in terms of the voltage difference between the two half bridges. In order to realize harmonious switching of the converter, a modulation strategy with capacitor voltages self balance is presented. According to the deduced output dc voltage function, transformerless operation without extreme duty cycles can be implemented. Experimental results from a 1kW prototype verify the validity of the proposed converter. It is suitable for ship electric power distribution systems.