• Title/Summary/Keyword: Power Distribution Systems

Search Result 1,310, Processing Time 0.03 seconds

An MCFQ I/O Scheduler Considering Virtual Machine Bandwidth Distribution

  • Park, Jung Kyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.10
    • /
    • pp.91-97
    • /
    • 2015
  • In this paper, we propose a MCFQ I/O scheduler that is implemented by modifying the existing Linux CFQ I/O scheduler. MCFQ observes whether the user requested I/O bandwidth weight is well distributed. Based on the I/O bandwidth observation, we improved I/O performance of the existing bandwidth distribution ability by dynamically controlling the I/O time-slice of the virtual machine. The use of SSDs as storage has been increasing dramatically in recent computer systems due to their fast performance and low power usage. As the usage of SSD increases and prices fall, virtualized system administrators can take advantage of SSDs. However, studies on guaranteeing SLA(Service Level Agreement) services when multiple virtual machines share the SSD is still incomplete. In this paper was conducted to improve performance of the bandwidth distribution when multiple virtual machine are sharing a single SSD storage in a virtualized environment. In particular, it was observed that the performance of the bandwidth distribution varied widely when garbage collection occurs in the SSD. In order to reduce performance variance, we add a MoTS(Manager of Time Slice) on existing CFQ I/O scheduler.

A Reliability Evaluation Model for the Power Devices Used in Power Converter Systems Considering the Effect of the Different Time Scales of the Wind Speed Profile

  • Ji, Haiting;Li, Hui;Li, Yang;Yang, Li;Lei, Guoping;Xiao, Hongwei;Zhao, Jie;Shi, Lefeng
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.685-694
    • /
    • 2016
  • This paper presents a reliability assessment model for the power semiconductors used in wind turbine power converters. In this study, the thermal loadings at different timescales of wind speed are considered. First, in order to address the influence of long-term thermal cycling caused by variations in wind speed, the power converter operation state is partitioned into different phases in terms of average wind speed and wind turbulence. Therefore, the contributions can be considered separately. Then, in regards to the reliability assessment caused by short-term thermal cycling, the wind profile is converted to a wind speed distribution, and the contribution of different wind speeds to the final failure rate is accumulated. Finally, the reliability of an actual power converter semiconductor for a 2.5 MW wind turbine is assessed, and the failure rates induced by different timescale thermal behavior patterns are compared. The effects of various parameters such as cut-in, rated, cut-out wind speed on the failure rate of power devices are also analyzed based on the proposed model.

A Study on Power Factor Control of Inverter-based DG System with Considering the Capacity of an Active Harmonic Filter and an Inverter (고조파 필터 및 인버터의 용량을 고려한 분산전원 시스템의 역률 제어에 관한 연구)

  • Kim, Young-Jin;Hwang, Pyeong-Ik;Moon, Seung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2149-2154
    • /
    • 2009
  • Electric power quality in power transmission/distribution systems has considerably been deteriorated with the increase in the capacity of distributed generators (DGs). It is because inverters, connecting DGs to conventional power grids, tend to generate harmonic current and voltage. For harmonic mitigation, a large amount of research has been done on passive and active filters, which have been operating successfully in many countries. This paper, therefore, presents how to adopt the filters to an inverter-based DG, with considering a system consisting of both inverter-based DG and harmonic filters. In particular, this paper describes the simulation results using the PSCAD/EMTDC: firstly, the relationship between total harmonic distortion(THD) of current and output power of DG: secondly, the harmonic mitigation ability of passive and active filters. The system, furthermore, is obliged to satisfy the regulations made by Korean Electric Power Corporation(KEPCO). In the regulations, power factor should be maintained between 0.9 and 1 in a grid-connected mode. Thus, this paper suggests two methods for the system to control its power factor. First, the inverter of DG should control power factor rather than an active filter because it brings dramatic decrease in the capacity of the active filter. Second, DG should absorb reactive power only in the range of low output power in order to prevent useless capacity increase of the inverter. This method is expected to result in the variable power factor of the system according to its output power.

Fuel cell based CHP technologies for residential sector (연료전지와 마이크로 열병합 발전기술)

  • Son, Young Mok
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.251-258
    • /
    • 2016
  • This article reports current status of micro fuel cell-combined heat and power (${\mu}FC$-CHP) systems which utilize both power and heat generated by fuel cells. There are several options for constructing CHP systems and among them, fuel cells are the most useful and their total energy efficiency combining heat and power can reach up to about 90%. Fuel cells are classified as five types based on the electrolyte, but the most suitable fuel cell types for the ${\mu}FC$-CHP system are proton exchange membrane fuel cells (PEMFCs) and solid oxide fuel cells (SOFCs). ${\mu}FC$-CHP systems have several advantages such as decrease of the transmission-distribution loss, reduced costs of electricity due to distributed power generation, and environmental-friendliness owing to zero emission. The main drawback of the ${\mu}FC$-CHP systems is the high initial investment, however, it keeps decreasing as the technology development reduces production costs. Currently, Japan is the most leading country of the ${\mu}FC$-CHP market, however, Korea tries to expand the market by planning the deployment of 1 million units of ${\mu}FC$-CHP systems and governmental subsidiary supporting of half of the install price. In this report, integration technologies for connecting FC and CHP, and technology trends of leading countries are presented as well.

Open and Short Circuit Switches Fault Detection of Voltage Source Inverter Using Spectrogram

  • Ahmad, N.S.;Abdullah, A.R.;Bahari, N.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.190-199
    • /
    • 2014
  • In the last years, fault problem in power electronics has been more and more investigated both from theoretical and practical point of view. The fault problem can cause equipment failure, data and economical losses. And the analyze system require to ensure fault problem and also rectify failures. The current errors on these faults are applied for identified type of faults. This paper presents technique to detection and identification faults in three-phase voltage source inverter (VSI) by using time-frequency distribution (TFD). TFD capable represent time frequency representation (TFR) in temporal and spectral information. Based on TFR, signal parameters are calculated such as instantaneous average current, instantaneous root mean square current, instantaneous fundamental root mean square current and, instantaneous total current waveform distortion. From on results, the detection of VSI faults could be determined based on characteristic of parameter estimation. And also concluded that the fault detection is capable of identifying the type of inverter fault and can reduce cost maintenance.

Safeguard system using distribution line and telecommunication network for controlling aimless behavior in senile elderly patients

  • Yamamoto, Hiromi;Wakamatsu, Hidetoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.885-890
    • /
    • 1988
  • This is a successive study of the development and application of an electronic safeguard system for elderly men (senile dementia patients) who wander without purpose because of declined mental capability, while retaining their physical ability. The new safeguard system is designed with some additional functions on the basis of the previously developed system. Firstly, alarms are designed not to disturb other patients at night, so that informations about doors from which the patients go out may be transmitted to helpers individually by radio paging system. Secondly, the system hardware can be set up anywhere without laying particular signal transmission cables, provided that there exist AC power distribution lines for the utilization as a transmission line of signals to alarm indicators. Thirdly, it is possible to have a grasp of the whole states of the safeguard systems at the center of operation by monitoring the operational state of each system with a necessary data acquisition according to its instruction through telecommunication network. Thus, each safeguard system can be economically supplied to the special nursing homes and the helpers are ensured more released from physical and psychological burdens so that they can devote themselves to the care of senile elderly men, thereby improving their patients' comfort and human dignity.

  • PDF

Development of Optical Fiber-based Daylighting System with Uniform Illumination

  • Ullah, Irfan;Shin, Seoyong
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.247-255
    • /
    • 2012
  • Daylighting has a very effective role in reducing power consumption and improving indoor environments in office buildings. Previously, it was not under consideration as a major source of renewable energy due to poor reliability in the design. Optical fiber as a transmission medium in the daylighting system demands uniform distribution of light to solve cost, heat, and efficiency issues. Therefore, this study focuses on the uniform distribution of sunlight through the fiber bundle and to the interior of the building. To this end, two efficient approaches for the fiber-based daylighting system are presented. The first approach consists of a parabolic mirror, and the second approach contains a Fresnel lens. Sunlight is captured, guided, and distributed through the concentrator, optical fibers, and lenses, respectively. At the capturing stage, uniform illumination solves the heat problem, which has critical importance in making the system cost-effective by introducing plastic optical fibers. The efficiency of the system is increased by collimated light, which helps to insert maximum light into the optical fibers. Furthermore, we find that the hybrid system of combining sunlight and light emitting diode light gives better illumination levels than that of traditional lighting systems. Simulation and experimental results have shown that the efficiency of the system is better than previous fiber-based daylighting systems.

Overload Analysis of Distribution Systems make use of PEVs Charging Modeling (전기 자동차의 충전 모델링을 이용한 배전계통 과부하 분석)

  • Choi, Sang-Bong;Lee, Jae-Jo;Sung, Back-Sub
    • Journal of Energy Engineering
    • /
    • v.29 no.3
    • /
    • pp.74-85
    • /
    • 2020
  • This paper presents an algorithm that evaluated the overload influence by bus upon the distribution system by calculating the daily load curve of PEVs charging by bus based on the daily charging patterns of PEVs according to PEVs penetration scenarios. The proposed algorithm calculates the number of PEVs to estimate the number of households by bus; the probability density function of the charging start time of PEVs, considering driving characteristics of PEVs and the daily load curve of PEVs charging by bus considering battery characteristics according to PEVs penetration scenarios. To verify the evaluation of the overload influence by bus on the distribution system in terms of the proposed algorithm, the cases were reviewed on the target bus(apartment and detached houses) among the feeders of the distribution systems at Dongtan new-town in Korea.

Ubiquitous Sensors for Supervision of Power Facilities in Overhead Power Distribution Lines (가공배전선로의 전력설비 감시를 위한 유비쿼터스 센서)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.59-65
    • /
    • 2007
  • Recently, ubiquitous sensor network(USN) techniques have been applied to electric power facility management. This paper dealt with the designed and fabricated ubiquitous sensors which monitor transformers and lightning arresters installed in overhead distribution systems. The sensors consist of a 8-[bit] microprocessor unit, a wireless communication nodule specified in IEEE 802.15.4, and associated electronics. A Rogowski coil was fabricated to measure load of transformer and surge current without saturation having good linearity up to 1000[A]. A zero-phase current transformer with a high relative permeability of $10^5$ at 180[Hz] was used to detect small leakage current of $50[{\mu}A]{\sim}1[mA]$ flowing lightning arrester, and the frequency bandwidth of the module is ranges from 12[Hz] to 1.24[kHz] at -3[dB].

High-power Yb Fiber Laser with 3.0-kW Output (3.0 kW 고출력 발진 단일 모드 Yb 광섬유 레이저)

  • Park, Jong Seon;Park, Eun Ji;Oh, Ye Jin;Jeong, Hoon;Kim, Ji Won;Jung, Yeji;Lee, Kangin;Lee, Yongsoo;Cho, Joonyong
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.147-152
    • /
    • 2021
  • We report high-power continuous-wave operation of a Yb-doped fiber laser at 1070 nm, pumped by high-power laser diodes at 976 nm. Based on theoretical calculation of the stimulated Raman scattering and temperature distribution in the fiber, we construct a bidirectionally pumped Yb-fiberlaser system incorporating a pair of fiber Bragg gratings and a cladding light stripper. The fiber laser yields 3.0 kW of continuous-wave output at 1070 nm in a diffraction-limited beam with M2 ≈ 1.26 for 4.1 kW of incident pump power, corresponding to a slope efficiency of 81.5%. The prospects for further power scaling are discussed.