• 제목/요약/키워드: Power Distribution Systems

검색결과 1,303건 처리시간 0.025초

전원선의 전력분석을 이용한 주요정보 유출 가능성에 관한 연구 (A Study on Leakage of Critical Information via the Power Analysis of Power Lines)

  • 한경호;이성호
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1571-1574
    • /
    • 2014
  • In this paper, we propose a unidirectional transmission of critical information obtained by keyboard hacking or kernel and keyboard driver hacking even though the computer is not connected to the external network. We show the hacking can be attempted in the proposed method to show the way preventing such attempts in advance. Firewalls and other various methods are used to prevent the hacking from the external network but the hacking is also attempted in various ways to detour the firewall. One of the most effective way preventing from the hacking attack is physically disconnect the internal intranet systems from the external internet and most of the government systems, military systems and big corporate systems are using this way as on one of the protection method. In this paper, we show the feasibility of transmission of security codes, etc via the short message to the external network on the assumption that a hacking program such as Trojan Horse is installed on the computer systems separated from the external network. Previous studies showed that the letters on the monitor can be hijacked by electromagnetic analysis on the computer to obtain the information even though the system is not connected ti the network. Other studies showed that the security code hint can obtained by analyzing the power consumption distribution of CPU. In this paper, the power consumption distribution of externally accessible power line is analyzed to obtain the information and the information can be transmitted to the external network. Software controlling the CPU and GPU usage is designed to control the power supply of computer. The sensors such as the Rogowski coils can be used on the external power line to collect the data of power consumption change rates. To transmit the user password by short message, due to the capacitive components and the obstacle from other power supply, A very slow protocol are used.

신재생에너지 시스템이 연계된 22.9[kV] 배전계통의 개선된 보호협조 방안 연구 (A Study on the Advanced Protective Coordination Schemes of 22.9[kV] Distribution System Interconnected New Renewable Energy System)

  • 최동만;최준호;노경수;문승일;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.426-428
    • /
    • 2005
  • Recently, There has been growing interest in new renewable energy systems with high-energy efficiency due to the increasing energy consumption and environmental pollution problems, but an insertion of new renewable energy systems to existing power distribution systems can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power. This paper was applied to Sukumar M, Brahma, A. Girgis[1] proposal schemes and identilys the faulted section performing short-circuit analysis by MATLAB programs to 22.9[kV] distribution system interconnected a large number of new renewable energy system and was analyzed on protective coordination between reclose and Sectionalizer.

  • PDF

Control Algorithms of Large Synchronous Machines for Starting Gas Turbosets

  • Hwang, Seon-Hwan;Kim, Jang-Mok;Ryu, Ho-Seon;Yoon, Gi-Gab
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.146-155
    • /
    • 2009
  • The static frequency converter (SFC) systems are used as a method of driving large synchronous machines in many power and industrial plants. In this paper, new control algorithms of SFC systems for starting gas turbo sets are proposed for a four quadrant operation: start-up at standstill; an acceleration up to the speed of the rated voltage; field weakening to reach the rated speed; synchronization to the main alternating current (AC) source; and dynamic braking to stop safely within the rating of the synchronous machine. Experimental results show that the proposed algorithms are proper and effective.

전력자동화서비스를 위한 광네트워크 설계 및 모뎀개발 (The Development of the Optical Network for the Automation Systems in Electric Power Companies)

  • 김명수;현덕화;조선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2543-2545
    • /
    • 2002
  • There are many applicable services such as remote metering, load control, distribution line automation, Pole transformer Monitoring having their own networks in the electric power company. The application of the optical network technology as the back-born network to the Automation Systems in KEPCO is potentially beneficial in reliability, speed, and expandability. The 1-core and 2-core optical modems were developed and used by the Distribution Automation System. But, They had some disadvantages and advantages. So, We designed the new optical modems applied each advantages. This paper presents some of design efforts and test results for the multi-channel optical modem at KRPRI.

  • PDF

지능형 전기품질 평가모델 개발 (Development of Intelligence Electric Power Quality Assessment Model)

  • 이범;최남섭;김경민
    • 제어로봇시스템학회논문지
    • /
    • 제13권6호
    • /
    • pp.531-536
    • /
    • 2007
  • This paper presents a power quality assessment model based on the Analytic hierarchy process. This model can assess unified power quality index which provide an overall performance of the distribution system. To obtain the unified power quality index, we propose the use of the AHP model which has three states: [Ideal]-[Actual]-[Worst]. The proposed method is especially useful and effective for planning. We have applied the proposed method to an actual relatively large system, and verified the usefulness.

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.

CIM 기반의 Distribution Automation System에 관한 연구 (A Study About Distribution Automation System Based on CIM)

  • 이희주;서정일;한주현
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.913-920
    • /
    • 2011
  • Distribution systems for operating the various systems should be operated organically. Distribution systems for organic operations extend the functionality of the system and system integration for the extension is doing. However, in systems integration for each unique non-standard definition of linkage and exchange systems are used. Non-standard definition of a unique linkage and exchange systems in the maintenance and expansion will result in many negative results. To solve these problems, the system and the exchange of information about the links between systems should define standards. IEC (International Electrotechnical Commission) power to solve these problems in the field of the Common Information Model (Common Information Model, CIM) standard (IEC61970, IEC61968) is defined as the transmission and distribution system integration and standardization for the exchange of information. In this paper, standardized system for building CIM-based distribution automation system should describe the process of building. In addition, the process of establishing a common information model needed (CIM) defined and associated services for a defined set of models is proposed in the standardization process.

직렬주입변압기가 없는 새로운 UPQC(Unified Power Quality Conditioner)의 성능분석 (Operation Analysis of Novel UPQC(Unified Power Quality Conditioner) without Series Injection Transformers)

  • 김희중;배병열;전영수;한병문;김현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.251-255
    • /
    • 2003
  • This paper proposes a novel UPQC(unified power quality conditioner) based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC/PSCAD, assuming that the UPQC is connected with the 22.9kV distribution line. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules and can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance. The control strategy for the proposing UPQC was derived using the instantaneous power method. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems and can be utilized for the future distribution system.

  • PDF

A Study on the Effect of Distributed Generation of the Reconfiguration of Distribution Networks

  • Nguyen, Tung Linh;Trinh, Trong Chuong;Truong, Viet Anh
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1435-1441
    • /
    • 2017
  • Distributed generation (DG) in the future will play an important role in the electricity supply systems, in wich can provide DG capacity from a few hundred kW to tens of MW. However, it is connected to the local power grid, DG will have certain influence on the power quality of the power grid. One of the most significant effects is that they will change the configuration of the local power grid as well as affecting the operation mode of the grid. This paper presents a method of finding the optimal open loop, analyzing and selecting the appropriate mode of operation to reduce power losses of power distribution networks that includes DG.

전력용 변압기의 절연유가 전계에 미치는 수치해석적 모델 (A Numerical Model of the Electric Field Distribution in Power Transformers)

  • 신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.3-6
    • /
    • 1990
  • The impact of the convected charges, which is caused by the electrification phenomina, in the oil-paper insulation systems of power transformers has been numerically investigated using FEM. The potential distribution of the oil-paper insulation system is assumed to be governed by three equations instead of the classical Laplace equation. When the charge density of oil and the conduction current are kept high, the field distortion or the interrace in a power transformer is considerably distorted due to the convected charges.

  • PDF