• Title/Summary/Keyword: Power Distribution Impedance

Search Result 190, Processing Time 0.026 seconds

Bus-voltage Sag Suppressing and Fault Current Limiting Characteristics of the SFCL Due to its Application Location in a Power Distribution System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1305-1309
    • /
    • 2013
  • The application of the superconducting fault current limiter (SFCL) in a power distribution system is expected to contribute the voltage-sag suppression of the bus line as well as the fault-current reduction of the fault line. However, the application effects of the SFCL on the voltage sag of the bus line including the fault current are dependent on its application location in a power distribution system. In this paper, we investigated the fault current limiting and the voltage sag suppressing characteristics of the SFCL due to its application location such as the outgoing point of the feeder, the bus line, the neutral line and the 2nd side of the main transformer in a power distribution system, and analyzed the trace variations of the bus-voltage and fault-feeder current. The simulated power distribution system, which was composed of the universal power source, two transformers with the parallel connection and the impedance load banks connected with the 2nd side of the transformer through the power transmission lines, was constructed and the short-circuit tests for the constructed system were carried out. Through the analysis on the short-circuit tests for the simulated power distribution system with the SFCLs applied into its representative locations, the effects from the SFCL's application on the power distribution system were discussed from the viewpoints of both the suppression of the bus-voltage sag and the reduction of the fault current.

PTW Application Method for Analysis the Industrial Distribution System (PTW를 이용한 산업용 수변전계통의 운영방안)

  • 설용태;이의용;이배희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.22-28
    • /
    • 2000
  • In this paper PTW(Power Tools for Windows) application method for analysis the industrial distribution system is proposed. T&D(Transmission and Distribution) and BICC methods is applied for the cable impedance and the X/R of transformer data is estimated by IEEE standard. The effectiveness of this method was improved by the electrical characteristics analysis of the real industrial distribution system.

  • PDF

Case Studies for Potential Distribution due to Power Source by Environmental Condition (전원설비에 의한 공간조건별 전위분포 사례 연구)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.50-58
    • /
    • 2011
  • In this paper, potential distribution analysis through the six kinds of case studies examined in the environmental conditions change within a limited space, by the power supply system installed. To interpret the potential distribution using electromagnetic field analysis program and the parameters were state of the ground, the outer wall of the configuration state and the presence of human potential distribution was simulated. Potential distribution analysis, the size of nominal voltage, depending on the impedance of human body to be determined on the impact of surprise decision, but if equipped with appropriate protective equipment can be protected from lightning have been confirmed.

Analysis of distribution grid for power Tine communication network (전력선 통신을 위한 배전 선로 해석)

  • Kim, Young-Sung;Kim, Jae-Chul;Kwon, Young-Mok;Lee, Yang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.102-104
    • /
    • 2005
  • This paper describes the model of the distribution grid for the broadband power line communication based on lumped-element circuits. In addition, this paper discusses various configurations of the MV distribution network in PLC. The distribution grid is not designed for communication so that it involves unfriendly conditions for PLC. The characterization of the MV distribution grid for PLC should be determined such as noise, attenuation, and mismatched impedance. For theses reasons, the PLC networks is described in using the scattering parameters. Finally, the n-port network is explained.

  • PDF

Analysis of electric characteristics for extension power supply between different grounding railway distribution system (접지방식이 상이한 철도배전계통의 연장급전을 위한 전기적 특성분석)

  • Jung, Ho-Sung;Han, Moon-Seob;Lee, Chang-Mu;Kwon, Sam-Young;Park, Hyeun-Jun
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.736-741
    • /
    • 2005
  • This paper presents electric characteristics analysis and safe configuration for extension power supply between existent 6.6kV ungrounded distribution system and establishment and improvement 22.9kV direct grounding distribution system. For this, we model 6.6kV ungrounded and 22.9kV direct grounding distribution system of urban underground, ground region. and rural electrical, unelectrical region using PSCAD/EMTDC and analyze voltage drop, charging current, ground and short fault through simulation. To analyze electric characteristics of extension power supply, we simulate extension power supply of overhead line of 6.6kV ungrounded system and underground line of 22.9kV direct grounding system of rural electrical region and propose operation condition for safe extension power supply through result of analysis. Characteristics of voltage drop, charging current, ground and short fault appear almost similarly with electrical characteristic of direct power supply. However, because unbalance of phases may cause relay's malfunction of ungrounded system and ground fault current of direct grounding system may demage facilities of ungrounded system, we propose safe system configuration such as impedance grounding system of neutral point.

  • PDF

Modeling of Arbitrary Shaped Power Distribution Network for High Speed Digital Systems

  • Park, Seong-Geun;Kim, Jiseong;Yook, Jong-Gwan;Park, Han-Kyu
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.324-327
    • /
    • 2002
  • For the characterization of arbitrary shaped printed circuit board, lossy transmission line grid model based on SPICE netlist and analytical plane model based on the segmentation method are proposed in this paper. Two methods are compared with an arbitrary shaped power/ground plane. Furthermore, design considerations for the complete power distribution network structure are discussed to ensure the maximum value of the PDN impedance is low enough across the desired frequency range and to guide decoupling capacitor selection.

  • PDF

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.

Matching Element Sensitivity Analysis for the Operation of a Dual-band Power Amplifier with CRLH Transmission Lines

  • Lee, Byeonguk;Kim, Changwook;Park, Youngcheol
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1050-1055
    • /
    • 2018
  • In this paper, we analyzed the sensitivity of matching elements for the dual-band operation of a power amplifier with composite right/left-handed (CRLH) transmission lines. Metamaterial theory enables CRLH transmission to support arbitrary impedance matching at dual frequencies. In general, at sub-GHz range, the CRLH matching networks are commonly implemented with lumped elements, which are prone to manufacturing distribution. In order to reduce the effect from the distribution of element values in design, we suggest a method to analyze the sensitivity of matching elements from the performance aspect of power amplifiers. Based on the analysis, a 40dBm dual-band power amplifier operating at 0.7GHz and 1.5GHz is designed.

Gysel 3:1 variable power divider using the dual characteristic impedance transmission line (이중 특성 임피던스 선로를 이용한 Gysel 3:1 가변 전력분배기)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1409-1415
    • /
    • 2021
  • The Gysel divider has the advantage of easily setting the resistor in the circuit. If the line impedance in the Gysel divider is set differently, the input signal can be distributed to the two output ports at various distribution ratios. This paper proposes the Gysel divider that can change the power distribution to 1:3 or 3:1 by changing the line impedance. The impedance change of the line can be implemented by placing a floating copper plate on the bottom of the microstrip-line. When the floating copper plate and the ground plane are connected, the line operates as the microstrip-line, and when the floating copper plate and the ground plane are disconnected, the line operates as the coplanar-line. The proposed Gysel divider was fabricated at the center frequency of 1.5GHz. The fabricated 3:1 Gysel divider has a stable value S11 of below -17dB, S21/S31 of 4.8±0.2dB, S21(to high output port) of -1.39±0.12dB and S31(to low output port) of -6.15±0.08dB over 1.3~1.7GHz.

A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence (PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구)

  • Oh Hui-Myoung;Choi Sung-Soo;Lee Jae-Jo;Kim Kwan-Ho;Whang Keum-Chan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.1
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.