• Title/Summary/Keyword: Power Converter Unit

Search Result 239, Processing Time 0.027 seconds

Development of Alkali Metal Thermal-to-Electric Converter Unit Cells Using Mo/TiN Electrode

  • Seog, Seung-won;Choi, Hyun-Jong;Kim, Sun-Dong;Lee, Wook-Hyun;Woo, Sang-Kuk;Han, Moon-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.3
    • /
    • pp.200-204
    • /
    • 2017
  • Molybdenum (Mo), an electrode material of alkali metal thermal-to-electric converters (AMTEC), facilitates grain growth behavior and forms Mo-Na-O compounds at high operating temperatures, resulting in reduced performance and shortened lifetime of the cell. Mo/TiN composite materials have been developed to provide a solution for such issues. Mo is a metal that possesses excellent electrical properties, and TiN is a ceramic compound with high-temperature durability and catalytic activity. In this study, a dip-coating process with an organic solvent-based slurry was used as an optimal coating method to achieve homogeneity and stability of the electrodes. Cell performance was evaluated under various conditions such as the number of coatings, ranging from 1 to 3 times, and heat treatment temperatures of $800-1100^{\circ}C$. The results confirmed that the cell yielded a maximum power of 9.99 W for the sample coated 3 times and heat-treated at $900^{\circ}C$.

Realization of Readout Circuit Through Integrator to Average MCT Photodetector Signals of Noncontact Chemical Agent Detector (비접촉 화학작용제 검출기의 MCT 광검출기를 위한 적분기 기반의 리드아웃 회로 구현)

  • Park, Jae-Hyoun
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.115-119
    • /
    • 2022
  • A readout circuit for a mercury-cadmium-telluride (MCT)-amplified mid-wave infrared (IR) photodetector was realized and applied to noncontact chemical agent detectors based on a quantum cascade laser (QCL). The QCL emitted 250 times for each wavelength in 0.2-㎛ steps from 8 to 12 ㎛ with a frequency of 100 kHz and duty ratio of 10%. Because of the nonconstant QCL emission power during on-duty, averaging the photodetector signals is essential. Averaging can be performed in digital back-end processing through a high-speed analog-to-digital converter (ADC) or in analog front-end processing through an integrator circuit. In addition, it should be considered that the 250 IR data points should be completely transferred to a PC during each wavelength tuning period of the QCL. To average and minimize the IR data, we designed a readout circuit using the analog front-end processing method. The proposed readout circuit consisted of a switched-capacitor integrator, voltage level shifter, relatively low-speed analog-to-digital converter, and micro-control unit. We confirmed that the MCT photodetector signal according to the QCL source can be accurately read and transferred to the PC without omissions.

A 3 V 12b 100 MS/s CMOS DAC for High-Speed Communication System Applications (고속통신 시스템 응용을 위한 3 V 12b 100 MS/s CMOS D/A 변환기)

  • 배현희;이명진;신은석;이승훈;김영록
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.9
    • /
    • pp.685-691
    • /
    • 2003
  • This work describes a 3 V 12b 100 MS/s CMOS digital-to-analog converter (DAC) for high-speed communication system applications. The proposed DAC is composed of a unit current-cell matrix for 8 MSBs and a binary-weighted array for 4 LSBs, considering linearity, power consumption, chip area, and glitch energy. The low-glitch switch driving circuit is employed to improve the linearity and the dynamic performance. Current sources of the DAC are laid out separately from the current-cell switch matrix core. The prototype DAC is implemented in a 0.35 urn n-well single-poly quad-metal CMOS technology. The measured DNL and INL of the prototype DAC are within $\pm$0.75 LSB and $\pm$1.73 LSB, respectively, and the spurious-free dynamic range (SFDR) is 64 dB at 100 MS/s with a 10 MHz input sinewave. The DAC dissipates 91 mW at 3 V and occupies the active die area of 2.2 mm ${\times}$ 2.0 mm.

Delta Sigma Modulation of Controller Input Signal for the LED Light Driver (시그마 델타 변조에 의한 LED 드라이버의 입력 콘트롤러 설계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.151-155
    • /
    • 2016
  • In this paper, we present the LED dimming control system by using ADPCM (Adaptive Differential Pulse Code Modulation). This ADPCM apparatus accurately controls the LED current with high resolution reducing the RFI (radio frequency interference) due to the spreading out of the harmonics of current of pulses. Additionally, this makes it easier to increase the accuracy of control operation. This study introduces to make a digitally controlled circuit for controlling LED with high-energy efficient by adopting pulse current to LED. The LED current drive system we designed are two systems, the digitally-controlled unit and analog switching mode power supply unit, can be developed separately. The simulation shows the sigma delta modulation of digital to analog converter's output when the input level is 0.7. From this simulation, the output is approached to accurately 0.15% to target value with 510 pulses.

A Novel Quadrant Search Based Mitigation Technique for DC Voltage Fluctuations in Multilevel Inverters

  • Roseline, Johnson Anitha;Vijayenthiran, Subramanian;V., Rajini;Mahadevan, Senthil Kumaran
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.670-684
    • /
    • 2015
  • The hybrid cascaded multilevel inverter (HCMLI) is a popular converter topology that is being increasingly used in high power medium voltage drives. The intricacy of the control technique for a HCMLI increases with the number of levels and due to fluctuating dc voltages. This paper presents a novel offline quadrant search based space vector modulation technique to synthesize a sinusoidal output from a dispersed pattern of voltage vectors due to different voltages in the auxiliary unit. Such an investigation has never been reported in the literature and it is being attempted for the first time. The method suggested distributes the voltage vectors for a reduced total harmonic distortion at minimal computation. In addition, the proposed algorithm determines the maximum modulation index in the linear modulation range in order to synthesize a sinusoidal output for both normal and abnormal vector patterns. It is better suited for a wide range of practical applications. It is particularly well suited for renewable source fed inverters which utilize large capacitor banks to maintain the dc link, which are prone to such slow fluctuations. The proposed quadrant search space vector modulation technique is simulated using MATLAB/SIMULINK and implemented using a Nexys-2 Spartan-3E FPGA for a developed prototype.

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

A Study on the Improvement of ripple factor tube voltage waveforms in inverter type X-ray generator (인버터식 X선장치의 관전압 맥동율 개선에 관한 연구)

  • 이성길;임홍우;조금배;정수복;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.234-238
    • /
    • 1999
  • In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.

  • PDF

Preliminary Design of AC/DC Converter Control System for ITER Superconducting Magnet (ITER 초전도자석 전원공급장치 제어시스템의 예비설계)

  • Suh, J.H.;Oh, J.S.;Choi, J.;Hwang, K.C.;Kang, J.B.;Lee, W.S.;Seo, E.;Kim, H.G.;kim, M.K.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.251-252
    • /
    • 2012
  • ITER(국제핵융합실험로) 제어시스템은 중앙제어와 Plant System으로 구성되며 CODAC, Central Interlock, Central Safety System으로 구분된다. 초전도자석에 전류를 공급하는 AC/DC 컨버터 시스템은 2상한, 4상한 구조의 전원 장치, 초기 플라즈마 발생에 필요한 Switching Network Unit, 코일에 저장된 에너지의 급속 방전을 위한 Fast Discharge Unit 및 무효 전력 보상장치로 구성된다. 4상한 전원장치는 1, 2, 4, 6대의 전원 장치가 직렬 접속되어 무효전력 발생이 최소로 하도록 제어된다. 대용량의 무효전력이 급격히 변화는 환경에서 계통 전압을 유지하기위해 무효전력보상장치는 각 전원 장치가 예측한 무효전력 값을 이용하여 제어한다. 본 논문은 ITER 전원 장치를 운전하기 위한 제어시스템의 개요와 예비설계 결과이다.

  • PDF

Improvement of VSWR Measurement for Various Modulated Signals at 1.8 GHz Band (다양한 변조 신호의 1.8 GHz 대역 VSWR 측정 개선에 관한 연구)

  • Park, Sang-Jin;Kang, Sung-Min;Koo, Kyung-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.833-839
    • /
    • 2011
  • This paper has suggested a technique for measuring VSWR at 1.8 GHz band for various modulated signals. By using directional coupler the power of incident and reflected wave is measured, and in order to minimize the size and cost of the measuring circuit, a SPDT(Single Pole Double Throw) switch is adopted to realize the circuit with just one detector and one A/D(Analog to Digital) converter. MCU(Micro Control Unit) is used to calculate the voltage reflection coefficient and VSWR, and the measured VSWR error has improved by approximately 0.2 with applying a simple bubble sorting algorithm to reduce the measurement error, the MCU process time and load.

EMC Tests for CTU EQM of GEO Communication Satellite (정지궤도 통신위성의 원격측정명령처리기 성능검증모델 전자파환경시험)

  • Koo, Ja-Chun;Choi, Jae-Dong;Kim, Joong-Pyo;Koo, Cheol-Hea;Choi, Seong-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.100-109
    • /
    • 2005
  • This paper introduce electromagnetic environmental requirements, test procedures and test results for the Command Telemetry Unit(CTU), which is engineering qualification model for communication satellite in geostationary earth orbit. Also, through debugging of the CTU during the Electro Magnetic Compatibility(EMC) tests, this paper evaluates characteristics of noise generated by the CTU. It is also obtained that better EMC performance can be acquired by improving electrical power converter module of the CTU.