• 제목/요약/키워드: Power Capacity

검색결과 4,189건 처리시간 0.033초

Capacity Bounds in Random Wireless Networks

  • Babaei, Alireza;Agrawal, Prathima;Jabbari, Bijan
    • Journal of Communications and Networks
    • /
    • 제14권1호
    • /
    • pp.1-9
    • /
    • 2012
  • We consider a receiving node, located at the origin, and a Poisson point process (PPP) that models the locations of the desired transmitter as well as the interferers. Interference is known to be non-Gaussian in this scenario. The capacity bounds for additive non-Gaussian channels depend not only on the power of interference (i.e., up to second order statistics) but also on its entropy power which is influenced by higher order statistics as well. Therefore, a complete statistical characterization of interference is required to obtain the capacity bounds. While the statistics of sum of signal and interference is known in closed form, the statistics of interference highly depends on the location of the desired transmitter. In this paper, we show that there is a tradeoff between entropy power of interference on the one hand and signal and interference power on the other hand which have conflicting effects on the channel capacity. We obtain closed form results for the cumulants of the interference, when the desired transmitter node is an arbitrary neighbor of the receiver. We show that to find the cumulants, joint statistics of distances in the PPP will be required which we obtain in closed form. Using the cumulants, we approximate the interference entropy power and obtain bounds on the capacity of the channel between an arbitrary transmitter and the receiver. Our results provide insight and shed light on the capacity of links in a Poisson network. In particular, we show that, in a Poisson network, the closest hop is not necessarily the highest capacity link.

Incorporating Resource Dynamics to Determine Generation Adequacy Levels in Restructured Bulk Power Systems

  • Felder, Frank A.
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권2호
    • /
    • pp.100-105
    • /
    • 2004
  • Installed capacity markets in the northeast of the United States ensure that adequate generation exists to satisfy regional loss of load probability (LOLP) criterion. LOLP studies are conducted to determine the amount of capacity that is needed, but they do not consider several factors that substantially affect the calculated distribution of available capacity. These studies do not account for the fact that generation availability increases during periods of high demand and therefore prices, common-cause failures that result in multiple generation units being unavailable at the same time, and the negative correlation between load and available capacity due to temperature and humidity. A categorization of incidents in an existing bulk power reliability database is proposed to analyze the existence and frequency of independent failures and those associated with resource dynamics. Findings are augmented with other empirical findings. Monte Carlo methods are proposed to model these resource dynamics. Using the IEEE Reliability Test System as a single-bus case study, the LOLP results change substantially when these factors are considered. Better data collection is necessary to support the more comprehensive modeling of resource adequacy that is proposed. In addition, a parallel processing method is used to offset the increase in computational times required to model these dynamics.

전원설비 저감을 위한 고효율 전력변환기술 개발 (A Development of Efficient Power Conversion Technology for Reduction of Power Equipment)

  • 구명완;이우원;임계영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.142-144
    • /
    • 2008
  • The Former High Efficiency Inverter(the power restoration process) system process has advantage which is the energy reduction rather than the Former Inverter(the resistence damping process), However, under repair and remodeling, the power facilities capacity is not easy to increase that the former High Efficiency Inverter needs to increase the Power Facilities Capacity of 20~30% than the Inverter(the resistence damping process) so Therefore we are going to suggest the system which is not going to make an increase the power facilities capacity and is applicable the High Efficiency Inverter.

  • PDF

A Novel Multi-Function PV Micro-Inverter with an Optimized Harmonic Compensation Strategy

  • Zhu, Guofeng;Mu, Longhua;Yan, Junhua
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2284-2293
    • /
    • 2016
  • With the rapid development of clean energy, photovoltaic (PV) generation has been utilized in the harmonic compensation of power systems. This paper presents a novel multi-function PV micro-inverter with three stages (pseudo-two-stage). It can inject active power and compensate harmonic currents in the power grid at the same time. In order to keep the micro-inverter working under the maximum allowable output power, an optimized capacity limitation strategy is presented. Moreover, the harmonic compensation can be adjusted according to the customized requirements of power quality. Additionally, a phase shedding strategy in the DC/DC stage is introduced to improve the efficiency of parallel Boost converters in a wide range. Compared with existing capacity limitation methods, the proposed strategy shows better performance and energy efficiency. Simulations and experiments verify the feasibility of the micro-inverter and the effectiveness of the strategy.

FACTS적용계통에서의 송전용량 평가 알고리즘 (An Algorithm for Transfer Capability Evaluation in Power Systems with FACTS Device)

  • 윤용범;윤종수;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.880-883
    • /
    • 1998
  • In this paper, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS device is presented. The real power flow setting of the FACTS device is adjusted so that it transfer the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS device can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

내적가역 사이클의 최대출력 조건 (The Maximum Power Condition of the Endo-reversible Cycles)

  • 정평석;김수연;김중엽;류제욱
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.172-181
    • /
    • 1993
  • 본 연구에서는 이 사이클 주위에 열전달이 추가된 열기관에 대하여 최대출력 조건 등을 구하고, 내부의 사이클이 각각 타노 사이클 및 브레이튼 사이클인 경우의 결과와 비교하여, 내적가역 최대출력 사이클들의 특성을 밝히고자 한다.

발전용량 및 풍속에 따른 국내 풍력 발전단지의 효율성 분석 (The Effect of Power Generation Capacity and Wind Speed on the Efficiency of the Korean Wind Farms)

  • 이중우;고광근;이기광
    • 경영과학
    • /
    • 제30권2호
    • /
    • pp.97-106
    • /
    • 2013
  • Of the new and renewable energies currently being pursued domestically, wind energy, together with solar photovoltaic energy, is a new core growth driver industry of Korea. As of May 2012, 33 wind farms at a capacity of 347.8MW are in operation domestically. The purpose of this study was to compare and analyze how efficiently each operational wind farm is utilizing its power generation capacity and the weather resource of wind. For this purpose, the study proceeded in 3 phases. In phase 1, ANOVA analysis was performed for each wind farm, thereby categorizing farms according to capacity, region, generator manufacturer, and quantity of weather resources available and comparing and analyzing the differences among their operating efficiency. In phase 2, for comparative analysis of the operating efficiency of each farm, Data Envelopment Analysis (DEA) was used to calculate the efficiency index of individual farms. In the final phase, phase 3, regression analysis was used to analyze the effects of weather resources and the operating efficiency of the wind farm on the power generation per unit equipment. Results shows that for wind power generation, only a few farms had relatively high levels of operating efficiency, with most having low efficiency. Regression analysis showed that for wind farms, a 1 hour increase in wind speeds of at least 3m/s resulted in an average increase of 0.0000045MWh in power generation per 1MW generator equipment capacity, and a unit increase in the efficiency scale was found to result in approximately 0.20MWh power generation improvement per unit equipment.

전력 계통 신뢰도 개선을 위한 대표적인 한류기 유형 및 적용 효과 분석 (Review of Typical Fault Current Limiter Types and Application Effect to Improve Power System Reliability)

  • 고윤석;이우철
    • 한국전자통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1133-1142
    • /
    • 2023
  • 전력 계통에서 전력 용량의 급격한 증가는 고장 용량이 차단기의 차단 용량을 초과하게 함으로써 계통의 신뢰도를 심각하게 저하시킬 수 있다. 한류기는 고장 용량을 차단 용량 레벨로 제한함으로써 신뢰도를 개선할 수 있는 실질적이고 효과적인 방법이다. 본 연구에서는 한류기의 전력계통 적용 시 적용 방법론을 개발하는 데에 도움이 될 수 있도록 먼저, 한류기의 유형별 구조와 동작원리를 분석하였으며 주요 장단점들을 비교하였다. 다음, 한류기의 전력 계통에 대한 적용 효과를 검증하기 위해 한류기가 도입된 전력계통을 모델링하였다. 끝으로, EMTP-RV를 이용하여 3상 단락 고장을 모의한 후, 한류기의 적용 전과 후의 전류를 비교를 통해 한류기에 의해 고장 전류 감소하는 것을 확인함으로써 적용 효과를 검증할 수 있었다.

태양광발전시스템의 장기운전에 의한 성능특성 분석 (The Long-term Operating Evaluation of the Grid Connected Photovoltaic System)

  • 김의환;강승원;김재언
    • 신재생에너지
    • /
    • 제7권2호
    • /
    • pp.28-35
    • /
    • 2011
  • Recently, photovoltaic systems have been devolved into much larger systems up to MW-scale. Photovoltaic industry participants give their focus on power generation capability of photovoltaic modules because their benefits can be decided from the amount of generation. The information on long-term performance change of photovoltaic modules helps to estimate the amount of power generation and evaluate the economic cost-benefits. Long-term performance of a PV system has been analyzed with operation data for 12 years from 1999 to 2010. In the first year, the amount of yearly power generation was 57.7 MWh with 13.2% capacity factor. In 2007, the amount of yearly generation was 44.3 MWh with 10.14% capacity factor, and in 2010, the amount was decreased down to 38.1 MWh with 8.7% capacity factor. The result means that long-term capacity factor has been 4.5% decreased for 12 years and that the amount of generation has been decreased 34.0% for 12 years which is 2.8 % per year. The latter capacity factor has been decreased faster than 0.20%, the average rate for 10 years. The performance decrease of the PV system is meant to be accelerated. The decrease of performance and utilization is due to aged deterioration of photovoltaic modules and lowering conversion efficiency of PCS.

Study on Thermal Load Capacity of Transmission Line Based on IEEE Standard

  • Song, Fan;Wang, Yanling;Zhao, Lei;Qin, Kun;Liang, Likai;Yin, Zhijun;Tao, Weihua
    • Journal of Information Processing Systems
    • /
    • 제15권3호
    • /
    • pp.464-477
    • /
    • 2019
  • With the sustained and rapid development of new energy sources, the demand for electric energy is increasing day by day. However, China's energy distribution is not balanced, and the construction of transmission lines is in a serious lag behind the improvement of generating capacity. So there is an urgent need to increase the utilization of transmission capacity. The transmission capacity is mainly limited by the maximum allowable operating temperature of conductor. At present, the evaluation of transmission capacity mostly adopts the static thermal rating (STR) method under severe environment. Dynamic thermal rating (DTR) technique can improve the utilization of transmission capacity to a certain extent. In this paper, the meteorological parameters affecting the conductor temperature are analyzed with the IEEE standard thermal equivalent equation of overhead transmission lines, and the real load capacity of 220 kV transmission line is calculated with 7-year actual meteorological data in Weihai. Finally, the thermal load capacity of DTR relative to STR under given confidence is analyzed. By identifying the key parameters that affect the thermal rating and analyzing the relevant environmental parameters that affect the conductor temperature, this paper provides a theoretical basis for the wind power grid integration and grid intelligence. The results show that the thermal load potential of transmission lines can be effectively excavated by DTR, which provides a theoretical basis for improving the absorptive capacity of power grid.