• Title/Summary/Keyword: Power Capacity

Search Result 4,198, Processing Time 0.027 seconds

Centrifugal Clutch Design for an Unmanned Helicopter - Theoretical Analysis of Power Transfer - (농용 무인헬리콥터의 원심클러치 설계 - 동력 전달의 이론분석 -)

  • Lee, J.H.;Koo, Y.M.;Shin, S.K.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • An agricultural unmanned helicopter was suggested for an alternative to current pesticide application methods to solve such problems as high cost, low efficiency, shirking task and unsafe work. To pursuit this trend, researches on the development of unmanned helicopters have been accelerated in Korea as well. In this research, a guide type centrifugal clutch that plays an important role in the unmanned helicopter was studied. Theoretical analyses and experimental tests were conducted for designing an optimal clutches. Main design factors of the guide type centrifugal clutch were found to be spring constant, free length of spring, mass of friction sector, contact area, allowable pressure, number of friction sector, friction coefficient, radius of drum, and clutch arrangement. And these design factors could be the functions of engaging engine speed and desired power transfer capacity. The result of the single clutch test showed the power transfer capacity of 14.1 PS at 5,800 rpm and the result of the dual clutch test showed that the capacity of 17.7 PS at 5,600 rpm. These experimental results agreed well the theoretical simulations.

Debt Issuance and Capacity of Korean Retail Firms (유통 상장기업들의 부채변화에 관한 연구)

  • Lee, Jeong-Hwan;Son, Sam-Ho
    • Journal of Distribution Science
    • /
    • v.13 no.9
    • /
    • pp.47-57
    • /
    • 2015
  • Purpose - The aim of this paper is to investigate the explanatory power of the Pecking-order theory (the cost of financing increases with asymmetric information) among Korean retail firms from the perspective of debt capacity. According to the Pecking-order theory, a firm's first preference is to use internal funds for its capital needs, its next preference is the issuance of debt, and its last preference is the issuance of equity; this is due to the information asymmetry problem between existing shareholders and investors. However, prior empirical studies, such as Lemmon and Zender (2010), argue that the entire sample test for the Pecking-order theory could be misleading due to the different levels of debt issuance capability of each of the individual firms; in fact, they confirm that the explanatory power of the Pecking-order theory improves after taking into account the differences in debt capacity of the U.S. firms they examined. This paper implements a case study approach among Korean retail firms to examine the relationship between debt capacity and the explanatory power of the Pecking-order theory in Korea. Research design, data, and methodology - This study uses the sample of public retail firms on the Korea Composite Stock Price Index (KOSPI) from the time period of 1990 to 2013. We gather related financial and accounting statements from the financial information firm WISEfn. Credit rating information is provided by the Korea Investor Service. We employ the models of Lemmon and Zender (2010) and Son and Kim (2013) to measure a firm's debt capacity. Their logit models use the rating dummy variable as a dependent variable and incorporate other firm characteristics as independent variables to estimate debt capacity. To test the Pecking-order theory, we adopt variants of the financing deficit model of Shyam-Sunder and Myers (1999). In the test of the Pecking-order theory, we consider all of the changes in total debt obligations, current debt obligations, and long-term debt obligations. Results - Our main contribution to the literature is our confirmation of the predicted relationship between debt capacity and the explanatory power of the Pecking-order theory among Korean retail firms. The coefficients on financing deficits become greater as a firm's debt capacity improves. This is consistent with the results of Lemmon and Zender (2010). The coefficients on the square of the financing deficits are also negative for the firms in the largest debt capacity group, which is also consistent with the predictions in prior literature. Conclusions - This study takes a case study approach by examining Korean retail firms. We confirm that the Pecking-order theory explains the capital structure of retail firms more appropriately, after taking into account the debt capacity of each firm. This result suggests the importance of debt capacity consideration in the testing of the Pecking-order theory. Our result also implies that there has been a potential underestimation of the explanatory power of the Pecking-order theory in existing studies.

Study on Emergency Generator Capacity Selection(PG3) in the Chemical Plant (화학 플랜트에서의 비상발전기 용량선정 방안(PG3)에 관한 연구)

  • Lee, Seung-Jae;Jo, Man-Young;Kim, Se-Yong;Kim, Eun-Tae;Kang, Byoung-Wook;Park, Han-Min;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.55-60
    • /
    • 2015
  • PG and RG methods are widely known method for calculating the capacity of the emergency generator in construction electrical installation. PG and RG methods are mainly used as a saving a life, fire protection, fire fighting in construction. Because no long distance between the emergency generator and electric motor feeder, the relatively small motor power in construction electrical installation, the capacity of generator in PG and RG methods are little problem of voltage and reactive power of generator. However in many cases the application of the PG and RG method is difficult in the Chemical Plant because it is long distance between the generator and the motor Feeder and motor capacity is very large. Motor starting power factor is about 0.2 lagging power factor and motor starting current is about 6times during motor staring. Also Most of the staring current component is a reactive power component. therefore, it is many cases that lack of reactive power and excess of allowable voltage drop limit and After selection of emergency diesel generator, problems happen during motor starting. Therefore, to be selection of effective emergency generator, active generator power, reactive power and the required reactive power during large motor starting should be considered in chemical plant. It is also required of the verification process through simulation because hand calculation is very difficult considering study cases.

Case Studies on the Electric Power Loss Reducing Methodology for Transformer Installation in Sewage Treatment Plant (하수처리장 변압기 설치사례 연구를 통한 전력손실 저감방안)

  • Kim, Chu-Young;Choi, Chang-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.70-77
    • /
    • 2011
  • Sewage treatment plants, consuming 1,756[GWh] which is 0.53[%] of national wide electricity consumption, is one of the electricity consuming facilites. At the research of electricity consumption and power quality analysis on sewage treatment plants, average utilization of transformer was less than 40[%] because peak load was very lower than its capacity due to excess capacity. So reduction of power loss can be achieved by transformer design optimization. The achievement in this research, is to meet reduction of power loss through optimizing the capacity and to improve as high efficiency-low loss transformer while the transformer is operating.

Regression Analysis of Vibration Phenomenon on the Load Capacity and Elapsed Year of a Power Transformer

  • Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.3
    • /
    • pp.30-37
    • /
    • 2009
  • The majority of the causes for the failures of power transformers in operation are mechanical defects due to vibration. The vibration phenomenon was measured from the power transformers in operation in the substations. The vibration measurement was performed in a $6{\times}4$ structure on one side of each transformer. The vibrations of the measured points were presented in two and three dimensions and analyzed. The results, according to the elapsed year of the transformer and the load capacity to the transformer, were analyzed. These results could be used as basic data with which to establish vibration standards for power transformers. In addition, the load capacity-vibration phenomenon correlation was examined and regression analysis was performed to derive the estimation function. The vibration phenomenon according to the elapsed yeah was also estimated to derive the function. Then the analysis of the power transformers was used to set vibration standards for them based on the vibration data.

A Study on System Modeling, Capacity and Voltage rating to supply HTS Power Transmission Cable to Metropolitan Area (고온초전도 케이블의 대도시 계통적용을 위한 모델링 및 송전용량과 전압계급의 검토)

  • 최상봉;정성환;김대경;김학만;문영환;성기철
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.61-65
    • /
    • 2002
  • It becomes difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. This paper presents possible applications of an HTS superconducting power cables for transmitting electric power in metropolitan areas. Reflected were its important distinction such as compactness for installation in underground ducts and considerably high efficiency compared with present underground cables. In this paper, system modeling, transmission capacity and voltage class of compact HTS cables which should be applied to existing ducts were reviewed. Based on this, the following items on urban transmission system are examined. (1) A method of constructing a model system to introduce high temperature superconducting cables to metropolitan areas is presented. (2)The maximum outer diameter of HTS cables to be accommodated in exiting ducts is calculated based on the design standards for current cable ducts. (3)The voltage level that can be accommodated by existing ducts is examined.

A Study on the Optimal Power Flow with Suppressing the Short Circuit Capacity in Power Systems (전력계통의 고장용량 억제를 위한 최적조류계산 연구)

  • Lee, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.12
    • /
    • pp.575-580
    • /
    • 2000
  • Switching of the transmission lines(T/L) is one of the ways for suppressing the short circuit capacity. This paper presents the extended optimal power flow(OPF) to the problem of selecting the T/Ls to be open. The constraints of the short circuit currents within limits are added to the inequalities of OPF. Also, the overload on the other lines due to switching of T/Ls is avoided by the linearized inequalities. The number of the open lines can be minimized by incorporating into the objective function of OPF in order to maintain reliability. The method of an effective calculation of the extended OPF is also proposed in this paper, which makes the two parts decoupled. The one concerning the generation dispatch is solved in the first place by the conventional method. Secondly, the other concerning the line-switching is optimized by the proposed formulation.

  • PDF

Capacity of DS/CDMA system with imperfect power-control (불완전한 전력 제어 셀룰라 DS/CDMA 시스템의 용량 분석)

  • 김준철;박진수;곽경섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.8
    • /
    • pp.1632-1642
    • /
    • 1997
  • In this paper, we studied the effects of the power control imperfection on the system performances of a microcellular DS/CDMA system. The maximum user capacity, defined as the maximum number of users can be serviced simultaneouly, meeting a given voice quality, is first considered. Then the performence degradation due to the control error is analyzed. The frequency selective Raician channel model is used to characterize a microcellular mobile communication environment. The DS/CDMA system under consideration uses BPSK modulation and convolutional coding/Viterbe decoding with soft decision for forward error correction. It is shown that the user capacity falls linearly down with the increase of the power control error(in terms of the standard deviation in dB) and the interference from users outside the third tier cells have a minor effect on the performance. And the performance of DS/CDMA with the imperfect power control model is made to be less than 50% of that with perfect power control moded.

  • PDF

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

Optimal Power Control Strategy for Wind Farm with Energy Storage System

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.726-737
    • /
    • 2017
  • The use of energy storage systems (ESSs) has become a feasible solution to solve the wind power intermittency issue. However, the use of ESSs increases the system cost significantly. In this paper, an optimal power flow control scheme to minimize the ESS capacity is proposed by using the zero-phase delay low-pass filter which can eliminate the phase delay between the dispatch power and the wind power. In addition, the filter time constant is optimized at the beginning of each dispatching interval to ensure the fluctuation mitigation requirement imposed by the grid code with a minimal ESS capacity. And also, a short-term power dispatch control algorithm is developed suitable for the proposed power dispatch based on the zero-phase delay low-pass filter with the predetermined ESS capacity. In order to verify the effectiveness of the proposed power management approach, case studies are carried out by using a 3-MW wind turbine with real wind speed data measured on Jeju Island.