• Title/Summary/Keyword: Power Cabinet

Search Result 80, Processing Time 0.022 seconds

Shaking Table Test to Verify the Seismic Performance of Nuclear Electric Components (원자력 전기기기 부품의 내진성능 확인을 위한 진동대 실험)

  • Chang, Sung Jin;Jeon, Bub Gyu;Park, Dong Uk;Kim, Sung Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.141-147
    • /
    • 2024
  • Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.

Composition Technology of Pulsed Power System with High Current (대전류 고속펄스파워시스템의 구성기술)

  • Lee, Hyeong-Ho;Seo, Kil-Soo;Kim, Young-Bae;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2179-2181
    • /
    • 1999
  • This paper describes the composition technology of pulsed power system with high current. The capacitor bank, control cabinet, dc charging unit, closing switch and cable system etc. employed with the system components are described. Especially the development of the inverse pinch switch enabled the generation of the very high current.

  • PDF

Seismic Fragility Evaluation of Cabinet Panel by Nonlinear Time History Analysis (비선형시간이력해석을 이용한 수배전반의 지진취약도 도출)

  • Moon, Jong-Yoon;Kwon, Min-ho;Kim, Jin-Sup;Lim, Jeong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.50-55
    • /
    • 2018
  • Earthquakes are almost impossible to predict and take place in a short time. In addition, there is little time to take aggressive action when an earthquake occurs. Therefore, there are more casualties and property damage than with other natural disasters. Recently, earthquakes have been occurring all over the world. As the number of earthquakes increase, studies on the safety of structures are being carried out. On the other hand, there are few studies on the electric facilities, which are relatively non - structural factors. Currently, electrical equipment in Korea is often not designed for earthquake safety and is quite vulnerable to damage when an earthquake occurs. Therefore, in this study, modeling was conducted through ABAQUS similar to an actual cabinet panel and 3D dynamic nonlinear analysis was performed using a natural seismic. According to seismic zone I and normal ground rock conditions of the power transmission and transmission facility seismic design practical guide, the maximum response acceleration of the performance level was 0.157g. In this study, however, it was not safe to reach the limit state of 30% of the analytical result at 0.1g for the general cabinet panel. From the results, the seismic fragility curve was derived and analyzed. The derived seismic fragility curve is presented as a quantitative basis for determining the limit state of the cabinet panel and can be utilized as basic data in related research.

Seismic Response Prediction of a Structure Using Experimental Modal Parameters from Impact Tests (충격시험에 의한 실험모드특성을 이용한 구조물의 지진응답 예측)

  • Cho, Sung-Gook;Joe, Yang-Hee;So, Gi-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.75-84
    • /
    • 2010
  • An in-cabinet response spectrum should be generated to perform the seismic qualification of devices and instruments mounted inside safety-related electrical equipment installed in nuclear power plants. The response spectrum is available by obtaining accurate seismic responses at the device mounting location of the cabinet. The dynamic behavior of most of electrical equipment may not be easily analyzed due to their complex mass and stiffness distributions. Considering these facts, this study proposes a procedure to estimate the seismic responses of a structure by a combination of a test and subsequent analysis. This technique firstly constructs the modal equations of the structure by using the experiment modal parameters obtained from the impact test. Then the seismic responses of the structure may be calculated by a mode superposition method. A simple steel frame structure was fabricated as a specimen for the validation of the proposed method. The seismic responses of the specimen were estimated by using the proposed technique and compared with the measurements obtained from the shaking table tests. The study results show that it is possible to accurately estimate the seismic response of the structure by using the experimental modal parameters obtained from the impact test.

Operation Test of Control Element Drive Mechanism Using a Power Controller (전력제어기를 이용한 제어봉 구동장치 동작시험)

  • Kim, Choon-Kyung;Lee, Jong-Moo;Jeong, Soon-Hyun;Cheon, Jong-Min;Kweon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.741-743
    • /
    • 2004
  • In this paper, we describe a Control Element Drive Mechanism(CEDM) operation test using a Power Controller. By testing, we can catch the mechanical and electrical characteristics of CEDM and obtain the information about the improvement of CEDM and the design of CEDM power cabinet. The power controller for CEDM introduced in this paper can input firing angles directly into gate drive circuits of thyristors so that this method can be used to derive the maximum and minimum values of firing angles within available limits for a 3-phase half-wave rectifier. Angle inputs help us understand each coil's response characteristics. Since this power controller generates a serial sequence for CEDM insertion and withdrawal operations, we may judge whether CEDM works correctly as expected or not in each phase of a step movement.

  • PDF

Investigating Constitutionalism by the Five Important Officials at the End of the Late-Qing Dynasty - Focusing on Duan Fang (청말신정(淸末新政) 시기 오대신출양(五大臣出洋)과 군주입헌론의 전개 - 단방(端方)을 중심으로)

  • Cho, Se-Hyun
    • Journal of North-East Asian Cultures
    • /
    • v.19
    • /
    • pp.23-48
    • /
    • 2009
  • Duan Fang's doctrine of constitutional monarchy went forward from monarchy to constitutional government based on that an establishment of constitution political structure is superior to a arbitrary rule political structure. And Duan Fang's doctrine featured limitation of monarch's authority protection of subjects' rights. He thought constitution government should be based on the establishment of constitution preparation. He believed that China need to take merit equally in the process of establishment of constitution preparation. In spite of this flexible recognition, there was not enough consideration about an ideological, social and economical basis that can make possible constitutional government operation. He had understood constitutional government system from angle of monarch's safety and the wealth and power of nation. The view was that a responsible Cabinet was for monarch's safety and the nation assembly judicature local autonomous is a system for safety of nation showed us. In his opinion, neither main task of congress is legislation, cabinet nor is the high ranking executive agency, however, he expected to constitutionalism system to become a buffing role instead of monarch. A little pure and simple thinking that open nation assembly and execute constitutional monarchy could make China powerful and wealthy might reflected urgent situation at that time.

Design of FPGA in Power Control Unit for Control Rod Control System (원자로 제어봉 구동장치 제어시스템용 전력제어기 FPGA 설계)

  • Lee, Jong-Moo;Shin, Jong-Ryeol;Kim, Choon-Kyung;Park, Min-Kook;Kwon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.563-566
    • /
    • 2003
  • We have designed the power control unit which belongs to the power cabinet and controls the power supplied to Control Rod Drive Mechanism(CRDM) as a digital system based on Digital Signal Processor(DSP). The power control unit dualized as the form of Master/Slave has had its increased reality. The Central Process Unit(CPU) board of a power control unit possesses two Digital Signal Processors(DSPs) of the control DSP for performing the tasks of power control and system monitoring and the communication of the Control DSP and the Communication DSP. To accomplish the functions requested in the power control unit effectively, we have installed Field Programmable Gate Arrays(FPGAS) on the CPU board and have FPGAs perform the memory mapping, the generation of each chip selection signal, the giving and receiving of the signals between the power controllers dualized, the fault detection and the generation of the firing signals.

  • PDF

Power Supply and Control System for Injector of Ion Accelerator (이온 가속기의 인젝터 전원 장치 및 제어 시스템)

  • Im, Geun-Hui;Nikiforov, S.A.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.544-549
    • /
    • 1997
  • Injector of high voltage or linear ion accelerator is intended to generate, extract and form beam of certain species with required parameters at the entrance of accelerating structure or, for low energy case, directly in the processing chamber (end station). Injector is the main part defining the ion accelerator performance and reliability. Its power supply and control system (PSCS) features are conditioned by placing the injector equipment at high voltage potential and by complexity of the plasma-beam load. The injector's PSCS should provide: - Transmission of electric power onto high voltage (h/v) terminal; - Obtaining of required output characteristics for injector equipment operation; - Transmission of the operational data and start/stop signals from h/v terminal to control cabinet; - Rremote control of injector; - Withstanding the high voltage breakdowns and X-ray radiation; - Compatibility with other equipment. The paper is concerned with analysis of injectors' PSCS structure and description of the system developed for 50 keV, 20 mA heavy ion injector.

  • PDF

Event Logging Method for Control Rod Control System (원자로 제어봉구동장치 제어시스템용 이벤트 기록 방법)

  • Cheon, Jong-Min;Kim, Choon-Kyung;Jo, Chang-Hui;Jeong, Soon-Hyun;Nam, Jeong-Han
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.552-554
    • /
    • 2003
  • This paper is about the method by which Power Control Unit(PCU) of Control Rod Control System(CRCS) logs events in the system and the real-time monitoring display. This method enables the functions like the event logging of Control Rod Drive Mechanism(CRDM)/power Cabinet, the off-line show of the event data logged and the on-line show by communication between the PCU and the monitoring display. Operators in a nuclear power plant must be able to grasp any possible abnormal states correctly. Because our newly designed system has a good ability to log and display the kinds, tine, and the prior and posterior states of urgent or non-urgent events, the operators can judge, maintain and repair the abnormal event more easily.

  • PDF

Effective Protection Methods of Household Electric Appliances. from Lightning Surges (가정용 전기기구의 효과적인 뇌서지 보호기법)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.3
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.