• Title/Summary/Keyword: Power Balance Method

Search Result 354, Processing Time 0.034 seconds

Study on the Multi-Zone Furnace Analysis Method for Power Plant Boiler (발전용 보일러에 대한 다중영역분할 화로해석 기법의 활용성 연구)

  • Baek, SeHyun;kim, Donggyu;Lee, Jang Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.427-432
    • /
    • 2020
  • In this study, a multi-zone furnace analysis method that couples a 1D energy and mass balance calculation with a 3D radiative heat transfer calculation is tested in order to verify its reliability. The calculated results for a domestic 500 MW capacity coal-fired boiler furnace were compared with the design data of the boiler manufacturer and CFD analysis, and a good agreement was achieved. Although this calculation method is less sophisticated than the CFD furnace analysis, it has an advantage in terms of calculation time while being able to provide the furnace behavior according to the fuel characteristics and operational variable changes. Therefore, it is expected to be useful for boiler operation diagnosis and daily fuel/operation planning.

Novel Method for Circulating Current Suppression in MMCs Based on Multiple Quasi-PR Controller

  • Qiu, Jian;Hang, Lijun;Liu, Dongliang;Geng, Shengbao;Ma, Xiaonan;Li, Zhen
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1659-1669
    • /
    • 2018
  • An improved circulating current suppression control method is proposed in this paper. In the proposed controller, an outer loop of the average capacitor voltage control model is used to balance the sub-module capacitor voltage. Meanwhile, an individual voltage balance controller and an arm voltage balance controller are also used. The DC and harmonic components of the circulating current are separated using a low pass filter. Therefore, a multiple quasi-proportional-resonant (multi-quasi-PR) controller is introduced in the inner loop to eliminate the circulating harmonic current, which mainly contains second-order harmonic but also contains other high-order harmonics. In addition, the parameters of the multi-quasi-PR controller are designed in the discrete domain and an analysis of the stability characteristic is given in this paper. In addition, a simulation model of a three-phase MMC system is built in order to confirm the correctness and superiority of the proposed controller. Finally, experiment results are presented and compared. These results illustrate that the improved control method has good performance in suppressing circulating harmonic current and in balancing the capacitor voltage.

Voltage Balance Control of Cascaded H-Bridge Rectifier-Based Solid-State Transformer with Vector Refactoring Technology in αβ Frame

  • Wong, Hui;Huang, Wendong;Yin, Li
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.487-496
    • /
    • 2019
  • For a solid-state transformer (SST), some factors, such as signal delay, switching loss and differences in the system parameters, lead to unbalanced DC-link voltages among the cascaded H-bridges (CHB). With a control method implemented in the ${\alpha}{\beta}$ frame, the DC-link voltages are balanced, and the reactive power is equally distributed among all of the H-bridges. Based on the ${\alpha}{\beta}$ frame control, the system can achieve independent active current and reactive current control. In addition, the control method of the high-voltage stage is easy to implement without decoupling or a phase-locked loop. Furthermore, the method can eliminate additional current delays during transients and get the dynamic response rapidly without an imaginary current component. In order to carry out the controller design, the vector refactoring relations that are used to balance DC-link voltages are derived. Different strategies are discussed and simulated under the unbalanced load condition. Finally, a three-cell CHB rectifier is constructed to conduct further research, and the steady and transient experimental results verify the effectiveness and correctness of the proposed method.

Optimal Design of the Hoist Hydraulic System Including the Counter Balance Valve and Differential Cylinder Circuit (카운터밸런스밸브와 차동실린더회로를 포함한 호이스트 유압장치의 최적설계)

  • Lee, S.R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 2008
  • The typical hydraulic system of hoist is composed of a hydraulic supply unit, a directional control valve, counter balance valve, and flow control valves. The flow capacity coefficients of flow control valves should be adjusted so that the hoist is operated at moderate speed and the hydraulic energy loss is minimized. However, it is difficult to adjust the flow coefficients of flow control valves by trial and error for optimal operation. Here, the steady state model of the hoist hydraulic system including the differential cylinder circuit is derived and the optimal flow capacity coefficients of flow control valves are obtained using the complex method that is one kind of constrained direct search method.

  • PDF

Program Development for Solving the Energy Balance Problem of Liquid Rocket Engine (액체로켓 엔진 Energy Balance 문제 해결을 위한 프로그램 개발)

  • Park, Soon-Young;Nam, Chang-Ho;Cho, Won-Kook
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.135-138
    • /
    • 2006
  • We developed an engine system design program by balancing the pressure-mass-power relation which can be acquired from each component's specification. In gas generator type open-cycle rocket engine system it is possible to distinguish the variables into two categories, which are input variables and requirement variables. We define 11 design variables corresponding to the 11 balance equations as functions of pressure, mass and power of target engine system. We solved these equations by Newton method. As an example we designed gas generator cycle engine system and finally we could conclude that this developed program is well suited to the engine system design.

  • PDF

Efficiency analysis of the boost converter using power balance condition (Power Balance 조건을 이용한 부스트 컨버터의 효율 분석)

  • Lee, Kook-Sun;Choy, Ick;Choi, Ju-Yeop;Song, Seung-Ho;An, Jin-Ung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Solar array has the following nonlinear characteristic, such as whose output current increases, output voltage is reduced. For this reason, boost converter with solar array system is always controlled to remain on the maximum power point of the solar array. In this case, we are not focused on the output of the solar array and not consider efficiency of the boost converter, which is assumed reliable. But efficiency of the converter also should be considered, which affects the total efficiency of the overall solar energy system. In this paper, efficiency calculation of the boost converter using power balance method is proposed, which will be used for a powerful reference before hardware realization.

A Development of 3 Phase Current Balance Control Algorithm (3상 전류평형 제어기술 알고리즘 개발)

  • Cheon, Y.S.;Seong, H.S.;Won, H.J.;Han, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1091-1093
    • /
    • 2001
  • The power semiconductor is widely used in the power plant or industrial field because of genealization and enlargement. It has been controlled and operated according to its own control method. Especially in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control algorithm is described. it gets over the past analog control system limit, controls SCR gate firing angle for 3 phase current balance.

  • PDF

Design and Implementation of High Pouter Amplifier for IMT-2000 Repeater (IMT-2000 중계기용 전력증폭기의 설계 및 제작)

  • 황상훈;방성일
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.185-188
    • /
    • 2001
  • In this paper, we design and implement high-power amplifier with 18 watt for W-CDMA repeater. We simulate microwave circuits using RF simulator, ADS1.3 and optimize the circuit to obtain the linear and high power using Harmonic balance method. Harmonic balance is an excellent method in the analysis of nonlinear system. The HPA is fabricated on tefron substrate($\varepsilon_{{\gamma}}$=3.48, h=0.5mm, T=0.035mm). From the measured result, the HPA has gain of 52dB, 1 dB compression power of 52.8dBm and good ACPR (Adjacent Channel Power Radio) performance.l Power Radio) performance.

  • PDF

Hybrid Double Direction Blocking Sub-Module for MMC-HVDC Design and Control

  • Zhang, Jianpo;Cui, Diqiong;Tian, Xincheng;Zhao, Chengyong
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1486-1495
    • /
    • 2019
  • Dealing with the DC link fault poses a technical problem for an HVDC based on a modular multilevel converter. The fault suppressing mechanisms of several sub-module topologies with DC fault current blocking capacity are examined in this paper. An improved half-bridge sub-module topology with double direction control switch is also designed to address the additional power consumption problem, and a sub-module topology called hybrid double direction blocking sub module (HDDBSM) is proposed. The DC fault suppression characteristics and sub-module capacitor voltage balance problem is also analyzed, and a self-startup method is designed according to the number of capacitors. The simulation model in PSCAD/EMTDC is built to verify the self-startup process and the DC link fault suppression features.

Implementation of a Power Simulator for Energy Balance Analysis of a LEO Satellite (저궤도 위성의 에너지 균형 분석을 위한 전력 시뮬레이터의 구현)

  • Jeon, Moon-Jin;Lee, Na-Young;Kim, Day-Young;Kim, Gyu-Sun
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.176-184
    • /
    • 2010
  • The power simulator for a LEO satellite is a useful tool to analyze mission validity and energy balance for various mission scenarios by estimating power generation, power consumption, depth of discharge, bus voltage, charging/discharging current, etc. In this paper, it is described the calculation algorithm of the solar array (SA) power, the satellite load power and the battery modeling method to develop a satellite power simulation. To simulate the SA power generation, three different operation modes (DET, MPPT, CV) of SAR (Solar Array Regulator) are considered with a SA model. The satellite load power is estimated using the satellite unit power database, the unit on/off configuration at some satellite operation modes. The bus voltage and battery charging/discharging current at the specific DoD (Depth of Discharge) are calculated based on the battery characteristics. By this satellite power simulator, it can be conveniently analyzed the energy balance and the validity of a planned mission of a LEO satellite.