• Title/Summary/Keyword: Power Amplitude

Search Result 1,051, Processing Time 0.032 seconds

A Study on Novel Hybrid Type Encoder Design for the Position Control with the High-resolution (고정도 위치제어용 Hybrid Type Encoder에 관한 연구)

  • Cho S. E.;Lee S. H.;Song S. G.;Park S. J.;Kwon S. J.;Kim C. U.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.87-94
    • /
    • 2005
  • This paper is about the compensation of phase angle error and amplitude difference in stationary 2 pole coordinates by the installation variation of sensor at low cost high resolution digital hybrid encoder. To solve the problem of amplitude difference at the existing hybrid encoder, we normalized the relative magnitude of the two analog signals. and also to solve the problem of installation variation when installed the sensor, we rotate the stationary 2 pole coordinates to compensate the location error of sensor. and we used and tested the QEP function and A/D port in DSP(TMS320F2812) to verify the mentioned proposed method.

Effects of Input Harmonics, DC Offset and Step Changes of the Fundamental Component on Single-Phase EPLL and Elimination

  • Luo, Linsong;Tian, Huixin;Wu, Fengjiang
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1085-1092
    • /
    • 2015
  • In this paper, the expressions of the estimated information of a single-phase enhanced phase-locked loop (EPLL), when input signal contains harmonics and a DC offset while the fundamental component takes step changes, are derived. The theoretical analysis results indicate that in the estimated information, the nth-order harmonics cause n+1th-order periodic ripples, and the DC offset causes a periodic ripple at the fundamental frequency. Step changes of the amplitude, phase angle and frequency of the fundamental component cause a transient periodic ripple at twice the frequency. These periodic ripples deteriorate the performance of the EPLL. A hybrid filter based EPLL (HF-EPLL) is proposed to eliminate these periodic ripples. A delay signal cancellation filter is set at the input of the EPLL to cancel the DC offset and even-order harmonics. A sliding Goertzel transform-based filter is introduced into the amplitude estimation loop and frequency estimation loop to eliminate the periodic ripples caused by the residual input odd-order harmonics and step change of the input fundamental component. The parameter design rules of the two filters are discussed in detail. Experimental waveforms of both the conventional EPLL and the proposed HF-EPLL are given and compared with each other to verify the theoretical analysis and advantages of the proposed HF-EPLL.

A Study on Developement of Optimization Model for Single Action Tidal Power Station (단류식 창조발전의 조력발전소 최적화 운영 Model 개발에 관한 연구)

  • Kim, Hyun-Han;Kim, Man-Kie;Kim, June-Kyou;Ok, Yeon-Ho;Kim, Kwang-Ho;Jeong, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1144_1145
    • /
    • 2009
  • Tidal power station is using the difference of the ebb and flow and the single action tidal power is dependent on tide amplitude and basin volume. Therefore the inflow of basin in rainy season has also effect on the daily power. Also if operating units are changed then starting head too changed. Therefore the number of units are very important for the optimization model. According to our study the primary point when we make a determination of optimization is starting head and governorl control mode. On this study optimization model for tidal power station is considered all of this conditions.

  • PDF

A Study on the Aging Characteristics of Power Capacitors using Electrical Methods (전기적 방법을 이용한 전력용 콘덴서 열화특성 연구)

  • 김은식;김영욱;김종서;윤철섭;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.199-202
    • /
    • 1998
  • Power capacitors are highly reliable equipment due to their completely enclosed configuration. Aging diagnosis system using partial discharge(PD) and acoustic emission(AE) is being highlighted as a research area for degradation of power capacitors. Their dielectric strength can be however reduced due to some stresses such as over-voltage or thermal degradation of the insulation material during their long period of operation. In this paper, it has been developed to express the AE of the EVENT(average amplitude) and HIT(pulse count) according to the source location. And real time measurement of PD signals for aging diagnosis of power capacitors.

  • PDF

Reducing the Harmonics of Static Var Compensator Using Multi-Step Inverter (멀티-스텝 인버터를 이용한 무효전력 보상장치의 고조파 저감)

  • Park, Hyun-Chul;Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.19-22
    • /
    • 2001
  • For stabilization and improving power factor in the power lines, various Static Var Compensators(SVC) have been considered to be installed and partly applicated already. With all these merits of the SVC, it stil has demerits, principally evoking harmonic problems. So far, many harmonic reduction type inverters have been used in various parts. In this paper, the reactive power is controlled by amplitude of the output voltage. This paper propose that the multiple voltage source inverter have controllable power factor made by load vary at receive-stage as lagging and leakage control. The theoretical analysis on this system was confirmed through the computer simulation and the experiments.

  • PDF

Development of the line coupler for reliable power line communication system (신뢰적인 전력선 통신을 위한 라인 커플러의 개발)

  • Choi, Won-Ho;Im, Byoung-No;Park, Chong-Yeun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2009-2010
    • /
    • 2006
  • This paper presents an adaptive line coupler to match input impedance of the Power line Communication(PLC) modem between access impedance of the power line. This line coupler provides maximum signal power transmiting capability, high reliability. The structure of this coupler is simple and designed to make a easy and low cost. The proposed line coupler is suitable for Amplitude Shift Keying(ASK) or Phase Shift Keying(PSK) modem. To figure out our models, the analysis of the transmitting features of power line channel is performed in the time domain at the carrier frequency. As a result of this study, we present the values of capacitors in the capacitor bank and adaptive line coupler circuit.

  • PDF

An Inductively Coupled Power and Data Link with Self-referenced ASK Demodulator and Wide-range LDO for Bio-implantable Devices

  • Park, Byeonggyu;Yun, Tae-Gwon;Lee, Kyongsu;Kang, Jin-Ku
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.120-128
    • /
    • 2017
  • This paper describes a neural stimulation system that employs an inductive coupling link to transfer power and data wirelessly. For the reliable data and power delivery, a self-referenced amplitude-shift keying (ASK) demodulator and a wide-range voltage regulator are suggested and implemented in the proposed stimulator system. The prototype fabricated in 0.35 um BCD process successfully transferred 1.2 Kbps data bi-directionally while supplying 4.5 mW power to internal MCU and stimulation block.

Optimization of input carrier powers considering satellite link environment in the multi-level SCPC systems (Multi-level SCPC 시스템에서 링크환경을 고려한 중계기 입력반송파 전력의 최적화)

  • 김병균;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.5
    • /
    • pp.1240-1255
    • /
    • 1996
  • This paper suggests power optimization technique in multi-level SCPC system as a method for efficient utilization of limited satellite power. The power optimization is realized by optimal assignment of satellite input carrier powers considering interference and noise generated in up-link and down-link. The Fletcher-Powell algorithm searching minimum(or maximum) point using gradient information is used to detemine the optimal input carrier powers. To apply Flectcher-Powell algorithm mathematical descriptions and their partial derivatives to interference and nose are presented. Because a target, which should be optimized, is satellite input carrier power, amplitude of each carrier group will be assumed to be an independent variable. The performance criterion for optimal power assignmentis classified into 4 categories with respect to CNR of destination receiver earth station to meet the requirement for various satellite link environment. Simulation results for two-level, four-level and six-level SCPC system are presented.

  • PDF

Power Signal Flicker Detection Based on Filter Bank Technique (필터뱅크기법에 기반한 전력신호 플리커 검출)

  • Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.179-193
    • /
    • 2016
  • In power quality monitoring, voltage fluctuation is one of the power quality problems, which cause light flickers. To determine the flicker severity, the flicker meter concept was developed in an IEC 61000-4-15 standard. Generally, voltage fluctuations are described as an amplitude modulation(AM). The flicker meter of IEC 61000-4-15 as an international standard for flicker measurement recommends square demodulation method to detect flicker signals from voltage fluctuation signals. This paper suggests a new effective method using filter bank to detect and estimate flicker signals, which do not need square demodulation. For the accurate detection of flicker signals, the filter bank is designed with a full consideration of the spectrum characteristics of voltage fluctuation signals described as AM. The frequency and magnitude of the detected flicker signals are estimated using recursive method. Computer simulations were performed on synthesized signals to prove validity of the proposed method.

Regional anomalies of cosmic microwave background power spectrum

  • Ju, Young;Park, Chan-Gyung;Hwang, Jai-Chan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.38.4-39
    • /
    • 2018
  • We analyze the Planck 2015 cosmic microwave background temperature fluctuation data to find any anomaly in the angular power spectra measured for partial regions on the sky. For disks with radius of $20^{\circ}$, $45^{\circ}$ and $90^{\circ}$, which are densely overlapping on the sky, we estimate the power excess and its statistical significance relative to the LambdaCDM expectation for some chosen ranges of angular scales. We also investigate the dipolar asymmetry using the power excess maps obtained for some chosen angular scales, and confirm the previously announced consistent dipole directions. The average dipole amplitude and the inner products of dipoles have been measured from the power excess maps at different angular scales. We conclude that although dipole directions are consistent the measured amplitudes are not statistically significant compared to the LambdaCDM model prediction.

  • PDF