• Title/Summary/Keyword: Power Adjustment

Search Result 373, Processing Time 0.03 seconds

Combustion Characteristics of Coal-Fired Boiler Depending on the Variations in Combustion Air Supply Method (미분탄 보일러의 연소용 공기공급 변화에 따른 노내 연소상태 해석)

  • Seo, San-Il;Park, Ho-Young;Kang, Dong-Soo;Jeong, Dong-Hae
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.156-162
    • /
    • 2010
  • 3-D CFD(Computational Fluid Dynamics) work were carried out to investigate the combustion characteristics in a boiler depending on the variations in air supply condition. For the gas temperature, $O_2$, NO, SOx at the outlet of economizer, the predicted values were been compared with the measured data. With the verified CFD model, the effects of air flow rates through SOFA(Separated Over Fire Air) and CCOFA(Closed Coupled Over Fire Air) on the combustion behavior in a boiler were simulated, and the distributions of NOx and gas temperature were mainly compared each other. The change in SOFA air flow rate gave the more sensitive effect on NOx than that in CCOFA. The distributions of gas temperature at convection path are differed with the changes in SOFA and CCOFA flow rate, so the combustion modification such as yaw anlge adjustment are required to get an enhanced gas temperature distribution.

Apolipoprotein E Phenotypes and the Relationship Among Lipid Levels, Nutrient Intakes, Lifestyles and Risk Factors Between Subjects with and without Hyperlipidemic Risk (Apolipoprotein E 다형성과 고지혈증 위험 유무에 따른 혈중 지질농도, 영양소 섭취, 생활습관 및 위험요인과의 관계)

  • Lee, Jae-Eun;Cho, Sang-Woon;Kang, Ji-Yeon;Paek, Yun-Mi;Choi, Chang-Sun;Park, Yoo-Kyoung;Choi, Tae-In
    • Journal of Nutrition and Health
    • /
    • v.41 no.5
    • /
    • pp.402-413
    • /
    • 2008
  • This study was performed to investigate Apolipoprotein E phenotypes and the relationship among lipid levels, nutrient intakes, lifestyles and risk factors between subjects with and without hyperlipidemic risk. The data were collected from 675 industrial male workers who had completed annual medical examination. Compared to the normal group, the hyperlipidemic risk group in Apo E3 and E4 had significantly higher BMI (p < 0.05) and showed significantly higher body fat (%), waist circumference and WHR in all types of Apo E (p < 0.05). In addition, the hyperlipidemic risk group had significantly higher total cholesterol, LDL-cholesterol, triglyceride and AI than the normal group in all types of Apo E (p < 0.05). Intakes of protein, calcium, phosphorus, iron, vitamin A, vitamin B1, vitamin B2, vitamin C and niacin in Apo E3 were significantly lower in the hyperlipidemic risk group than in the normal group (p < 0.05). In the logistic regression analysis, after adjustment for other factors, Apo E2 + E4, waist and WHR were the significant risk factors associated with hyperlipidemia, but protein intakes were associated with significantly lower risks of hyperlipidemia (p < 0.05). In conclusion, genetic factor (Apo E2 or Apo E4), anthropometric index and nutrient intake seem to influence hyperlidemic risk. Further studies and efforts will be needed to evaluate the independent relationships among hyperlipidemic risk factors.

A study on the Normal Steady State Operation Characteristics of PV System Based on the Test Device (태양광전원용 시험장치를 이용한 정상상태 운용특성에 관한 연구)

  • Hasan, Md.Mubdiul;Munkbaht, Munkbaht;Kim, Byung-Ki;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.512-516
    • /
    • 2012
  • Recently the Korean government's green energy growth policy has been taken at the national level due to the sufficient supply of renewable energy. Some specific technique should be taken in consideration for the operation of the grid voltage and power quality management. In this case, there may have some chance of operational problems. Typical problems arise when grid-connected solar power produced by Pacific sunshine. The power flow in the reverse direction can create overvoltage on the distribution line and gives value of malfunction on the system. Line voltage and overvoltage adjustment practice can stop these symptoms occurred. Under these circumstances, this paper presents an interconnection test devices for photovoltaic(PV) systems composed of distribution system simulator, PV system simulator and control and monitoring systems using the LabVIEW S/W, and simulates the customer voltage characteristics considering the 3 parameters on the introduction capacity for PV systems, system configuration and Power factor. This paper also proposes a new calculation algorithm for voltage profile to make comparison between calculation values and test device values. The results show that the simulation results for the normal operation characteristics of PV systems which are very practical and effective.

  • PDF

Assessment of Validity of Inpatient Classification System in Korean Medicine (KDRG-KM) (한의 입원환자분류체계의 적정성 평가)

  • Kim, Dongsu;Ryu, Jiseon;Lee, Byungwook;Lim, Byungmook
    • The Journal of Korean Medicine
    • /
    • v.37 no.3
    • /
    • pp.112-122
    • /
    • 2016
  • Objectives: This study aimed to assess the validity of 'Korean Diagnosis Related Groups-Korean Medicine (KDRG-KM)' which was developed by Health Insurance Review & Assessment Service (HIRA) in 2013 Methods: Among inpatient EDI claim data issued by hospitals and clinics in 2012, the data which included Korean medicine procedures were selected and analyzed. We selected control targets in the Korean medicine hospitals which had longer Episodes-Costliness index (ECI) and Lengthiness index (LI) than average of total Korean medicine hospitals, and compared the results of selection between the major diagnosis-based patient classification system and the KDRG-KM system. Finally, the explanation power (R2) and coefficient of variation (CV) of the KDRG-KM system using practice expenses were calculated. Results: The numbers of control target in Korean medicine hospitals changed from 36 to 32 when patient grouping adjustment method was changed from major diagnosis to KDRG-KM. For expenses of all outpatient claim data on Korean medicine, explanation power of KDRG-KM system was 66.48% after excluding outliers. CVs of expenses of patient groups in Korean medicine hospitals were gathered from under 70% to under 90%, and those in long-term care hospitals mostly belonged under 70%. Conclusions: The validity of KDRG-KM system was assured in terms of explanation power. By adapting KDRG-KM system, fairness of control targets selection for costliness management in Korean medicine hospitals can be enhanced.

Dimming Control of the LED Luminaire Emergency Exit Sign Operation using a Hybrid Super Capacitor of DC-DC Convertor (하이브리드 슈퍼커패시터 DC-DC 컨버터를 이용한 LED 비상 유도등 동작 디밍 제어)

  • Hwang, Lark-Hoon;Kim, Jin-Sun;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.220-229
    • /
    • 2017
  • In this paper, To take advantage a variety of DC power as the boost DC-DC converter design specifications through the inductor L and capacitor C through PSPICE to calculate the best estimate of the value. Boost DC-DC converter with a switch device using IRF840 and reverse recovery time Schottky diodes with excellent with constant current controller using D10SC6M and resistance can be configured to considering the Power LED Module was driven by the production. Converter's switching frequency is 50 kHz, the first Duty Rate was made to increase gradually depending on the value of the detection were, 10 % in the output voltage. As a result, the simulated Boost Power LED driver characteristics is in comparison with the design specifications, 5% or less as the error was approximated. Finally, when input 15 V were offered, a stable output 24 V were obtained. and Dimming Control through the adjustment of brightness and current consumption were possible.

A SURVEY ON THE UTILIZATION OF AGRICULTURAL MACHINERY

  • Lee, Y.B.;Shin, S.Y.;Oh, I.S.;Kim, H.J.;Kim, B.G.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.446-459
    • /
    • 2000
  • This study was carried out in order to find out an effective machinery utilization strategy by conducting a survey on utilization and maintenance of agricultural machinery. The survey showed that the no. of utilization hours for power tiller in a year was 190.2hrs, 208.6hrs for tractor, 59.1hrs for rice transplanter, 74.0 hrs for combine, 44.6 cultivator and 254.4hrs for 4.4hrs for grain dryer. The period covered the time the machine was until it became unserviceable. The results are as follows: 10.0yrs for power tiller, 7.5yrs for tractor, 7.4yrs for rice transplanter and 5.4yrs for combine. This indicate that the actual period of use for power tiller and rice transplanter was longer than the expected period of duration years so there is a need for adjustment. The factors considered by the farmers for purchasing agricultural machine were: farm size(32%), machine operation (26.0%), performance(l4.0%) and post or after sales service(12.6%), according to the survey. It showed that repair cost rate in a year was classified into major agricultural machine; 4.8% for combine; 3.9% for tractor; 3.5% for rice transplanter; 2.0% for power tiller; 1.6% for grain dryer; and 1.2% for cultivator. The reasons for poor maintenance were insufficient after sales service(25%) and difficulty in buying parts(75%) because of the unavailability of parts in local shops(55%), imported models(30%) and outmoded model(15%).

  • PDF

DESIGN OF A LOAD FOLLOWING CONTROLLER FOR APR+ NUCLEAR PLANTS

  • Lee, Sim-Won;Kim, Jae-Hwan;Na, Man-Gyun;Kim, Dong-Su;Yu, Keuk-Jong;Kim, Han-Gon
    • Nuclear Engineering and Technology
    • /
    • v.44 no.4
    • /
    • pp.369-378
    • /
    • 2012
  • A load-following operation in APR+ nuclear plants is necessary to reduce the need to adjust the boric acid concentration and to efficiently control the control rods for flexible operation. In particular, a disproportion in the axial flux distribution, which is normally caused by a load-following operation in a reactor core, causes xenon oscillation because the absorption cross-section of xenon is extremely large and its effects in a reactor are delayed by the iodine precursor. A model predictive control (MPC) method was used to design an automatic load-following controller for the integrated thermal power level and axial shape index (ASI) control for APR+ nuclear plants. Some tracking controllers employ the current tracking command only. On the other hand, the MPC can achieve better tracking performance because it considers future commands in addition to the current tracking command. The basic concept of the MPC is to solve an optimization problem for generating finite future control inputs at the current time and to implement as the current control input only the first control input among the solutions of the finite time steps. At the next time step, the procedure to solve the optimization problem is then repeated. The support vector regression (SVR) model that is used widely for function approximation problems is used to predict the future outputs based on previous inputs and outputs. In addition, a genetic algorithm is employed to minimize the objective function of a MPC control algorithm with multiple constraints. The power level and ASI are controlled by regulating the control banks and part-strength control banks together with an automatic adjustment of the boric acid concentration. The 3-dimensional MASTER code, which models APR+ nuclear plants, is interfaced to the proposed controller to confirm the performance of the controlling reactor power level and ASI. Numerical simulations showed that the proposed controller exhibits very fast tracking responses.

Anuran Metamorphosis: a Model for Gravitational Study on Motor Development

  • Jae Seung;Jin Cheul;In-Ho;Park, In-Ho
    • Animal cells and systems
    • /
    • v.4 no.3
    • /
    • pp.223-229
    • /
    • 2000
  • Limbs and supporting structures of an organism experience a full weight of its own when it lands from water, because neutral buoyancy in the aquatic habitat will be no longer available in the terrestrial world. Metamorphosis of anuran amphibians presents 8 good research model to examine how this transition from non-loading to weight-loading affects development of motor capacity at the time of their first emergence on land. Our video analysis of the transitional anurans, Rana catesbeiana, at Gosner stage 46 (the stage of complete transformation) demonstrated that the take-off speed increased 1.23-fold after the first six hours of weight-loading on the wet ground. It did not increase further during the following three days of loading, and was close to the level of mature frogs with different body mass. During development of larvae in deep water with no chance of landing through metamorphosis, both tension and power of a hindlimb anti-gravity muscle increased 5-fold between stages 37 and n. However, the muscle contractility increased more rapidly when the larvas could access the wet ground by their natural landing behavior after stages 41-42. Muscle power, one of major factors affecting locomotory speed, was 1.29-fold greater in the loaded than in the non-loaded larvae at the transitional stage. Thus, weight-loading had a potentially significant effect on the elevation of motor capacity, with a similar extent of increment in locomotory speed and muscle power during the last stages of metamorphosis. Such a motor adjustment of the froglets in a relatively short transitional period would be important for effective ecological interactions and survival in their inexperienced terrestrial life.

  • PDF

Adaptive Filtering for Aggregation in Sensor Networks (센서 네트워크에서 집계연산을 위한 적응적 필터링)

  • Park, No-Joon;Hyun, Dong-Joon;Kim, Myoung-Ho
    • Journal of KIISE:Databases
    • /
    • v.32 no.4
    • /
    • pp.372-382
    • /
    • 2005
  • Aggregation such as computing an average value of data measured in each sensor commonly occurs in many applications of sensor networks. Since sensor networks consist of low-cost nodes with limited battery power, reducing energy consumption must be considered in order to achieve a long network lifetime. Reducing the amount of messages exchanged is the most important for saving energy. Earlier work has demonstrated the effectiveness of in-network data aggregation and data filtering for minimizing the amount of messages in sensor networks. In this paper, we propose an adaptive error adjustment scheme that is simpler, more effective and efficient than previous work. The proposed scheme is based on self-adjustment in each sensor node. We show through various experiments that our scheme reduces the network traffic significantly, and performs better than existing methods.

Characteristics of Sparkover Discharge in Flowing Air with the variation of Reynolds Number (Reynolds Number를 변수로한 유동공기의 방전특성)

  • 김영헌;이광식;이동인
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.2
    • /
    • pp.37-48
    • /
    • 1991
  • This paper shows the characteristics of sparkover discharge in flowing air ranging from O(Reynolds number, Re) to $10.52{\times}10^4$(Re). Also, we investigated changes of discharge pattern for constant input power by adjustment of the Reynolds number. Flowing air duct of this investigation is a circular tube. The flow at the experimented positions' section is described as fully development laminar flow. The important results obtained from this study are as follows. The sparkover discharge path of flowing air can be analyzed by the theories of flow field for air. The sparkover voltage shows nearly the maximum value when the Reynolds number of flowing air ranges $3{\times}10^4$ to $4{\times}10^4$The maximum sparkover voltages of flowing air are about 6.3[kV] higher than those of static air. The discharge pattern can be controlled by adjustment of the Reynolds number.

  • PDF