• 제목/요약/키워드: Potentiometric detection

검색결과 61건 처리시간 0.029초

Nano Structured Potentiometric Sensors Based on Polyaniline Conducting Polymer for Determination of Cr (VI)

  • Ali, Mohammad-Khah;Ansari, Reza;Delavar, Ali Fallah;Mosayebzadeh, Zahra
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권4호
    • /
    • pp.1247-1252
    • /
    • 2012
  • In this paper, a potentiometric sensor based on polyaniline conducting polymer for potentiometric determination of Cr (VI) ions is reported. Polyaniline was synthesized electrochemically (cyclic voltammetry method) onto a micro pencil graphite electrode (0.7 mm diameter) in the presence of HCl and diphenylcarbazide (termed as (PGE/PAni/DPC). Some initial experiments were performed in order to find out the optimized conditions for preparation of the introduced Cr (VI) sensor electrode. The plot of E vs. log [Cr (VI)], showed a linear response in the range from $1.0{\times}10^{-6}$ to $1.0{\times}10^{-1}$ M. High repeatability with the detection limit of $8.0{\times}10^{-7}$ M was obtained.

Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin

  • Choi, Ki-Bong;Seo, Won-Jun;Cha, Seung-Hee;Choi, Jung-Do
    • BMB Reports
    • /
    • 제31권1호
    • /
    • pp.101-105
    • /
    • 1998
  • Immunoassay of botulinum toxin (BTX) B type was investigated using two typed of biosensors: light addressable potentiometric sensor (LAPS) and surface plasmon resonance (SPR) sensor. Urease-tagged and immuno-filtration capture method have been used for LAPS. Tag-free and direct binding real-time detection method have been used for SPR sensor. The detection limit of sandwich assay format with LAPS was 10 ng/ml, which was the lowest among methods tested. SPR has the advantage of being more convenient because tag-free direct binding assay can be used and reaction time was reduced, regardless of low sensitivity. This result shows that sandwich assay format with LAPS can be used as an alternative method of BTX mouse bioassay which is known as the most sensitive method for the detection of BTX.

  • PDF

Characterization and Food Application of a Potentiometric Biosensor Measuring $\beta$-Lactam Antibiotics

  • Park, In-Seon;Kim, Dong-Kyung;Kim, Nam-Soo
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권4호
    • /
    • pp.698-706
    • /
    • 2004
  • $\beta$-Lactam antibiotics such as penicillin G, amoxicillin, and ampicillin were determined by a potentiometric biosensor system which exploited penicillinase immobilized on Immobilon cellulose nitrate membrane and a flat-bottomed pH electrode-as the biological component and transducer. The optimum reaction buffer for maximum sensitivity was found as 2 mM of sodium phosphate buffer (pH 7.2). The detection limit of the biosensor could be extended to 1 $\mu{M}$ of the analytes by increasing the enzyme loading for immobilization to 100 units/$m\ell$. The model samples spiked with each of the standard penicillins were measured for their biosensor responses and HPLC peak area, resulting in the relative responses of 82.1-103.5% and 79.5-106.1% for the biosensor method along with HPLC analysis, respectively. This result showed a good precision of the current biosensor method for screening the penicillin compounds.

Potentiometric Homogeneous Enzyme-Linked Binding Assays for Riboflavin and Riboflavin Binding Protein

  • 김진목;김혜진;김미정;이동주;한상현;차근식
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권11호
    • /
    • pp.1018-1022
    • /
    • 1996
  • Adenosine deaminase (ADA) has been utilized as the label in devising a potentiometric homogeneous assay for riboflavin and riboflavin binding protein (RBP). The proposed homogeneous assay method employs an ADA-biotin conjugate as the signal generator and an avidin-riboflavin conjugate as the signal modulator in the solution phase. The catalytic activity of the ADA-biotin conjugate is inhibited in the presence of an excess amount of the avidin-riboflavin conjugate, and the observed inhibition is reversed in an amount proportional to the concentration of RBP added. When the analyte riboflavin is added to this mixture of ADA-biotin, avidin-riboflavin and RBP, the activity of the enzyme conjugate is re-inhibited in an amount proportional to the concentration of riboflavin. Since the enzyme label used in this system is ADA, an ammonia-producing enzyme, a potentiometric rather than photometric detection scheme is used to monitor the enzymatic activity in the assay.

The Potentiometric Studies on the Effects of Various Functional Groups in Disiloxane as an Anion-Selective Ionophore

  • Jung, Hyo-Jin;Lee, Myong-Euy;Lim, Chae-Yun;Paeng, Ki-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권1호
    • /
    • pp.57-62
    • /
    • 2005
  • The potentiometric responses for various anions are investigated with membrane electrode (membrane 1) based on 1,3-diethyl-1,3-dihydroxy-1,3-bis(2-dimethylaminomethyl ferrocenyl) disiloxane. The nitrate ion-selective electrode based on compound 1 gave a good Nernstian response of 58.18 mV per decade for nitrate with the detection limit of −e5.66 of log [NO3−e]. Compound 1 has all those functional groups and the other two compounds have less functional group of ferrocenyl or ferrocenyl and hydroxide, respectively. Even though, potentiometric response to anions was excellent at pH 5, the selectivity pattern for all three membrane electrode based on series of disiloxane is almost like Hofmeister sequence at pH 5. However, the membrane electrode 1-3 exhibited very different response to anions at pH 7. In this pH, NH2 is not protonated and ionophore may act as neutral carrier. Hydrogen bond may enhance the responsibility to hydrogen acceptors and intramolecular electro-active site may increase the permeability of analyte to ionophore in membrane.

Polymeric Membrane and Solid Contact Electrodes Based on Schiff Base Complexes of Co(III) for Potentiometric Determination of Perchlorate Ions

  • Soleymanpour, Ahmad;Hanifi, Abdolghafoor;Kyanfar, Ali Hossein
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권9호
    • /
    • pp.1774-1780
    • /
    • 2008
  • New PVC based polymeric membrane electrodes (PME) and coated glassy carbon electrodes (CGCE) based on synthesized Schiff base complexes of Co(III); [Co(Salen)$(PBu_3)_2$]$ClO_4$, [Co($Me_2$Salen)$(PBu_3)_2$]$ClO_4$, [Co(Salen)$(PBu_3)H_2O$]$ClO_4$; as anion carriers for potentiometric determination of $ClO_4\;^-$were studied. The PME and also CGCE electrodes prepared with [Co(Me2Salen)$(PBu_3)_2$]$ClO_4$ showed excellent response characteristics to perchlorate ions. The electrodes exhibited Nernstian responses to $ClO_4\;^-$ ions over a wide concentration range with low detection limits ($1.0 {\times} 10^{-6}\;mol\;L^{-1}$ for PME and $9.0 {\times} 10^{-7}\;mol\;L^{-1}$ for CGCE). The electrodes possess fast response time, satisfactory reproducibility, appropriate lifetime and, most importantly, good selectivity toward $ClO_4\;^-$ relative to a variety of other common inorganic anions. The potentiometric response of the electrodes is independent of the pH in the pH range 2.5-8.5. The proposed sensors were used in potentiometric determination of perchlorate ions in mineral water and urine samples. The interaction of the ionophore with perchlorate ions was shown by UV/Vis spectroscopy.

Investigation of Simple Electrochemical Conditions for Generation of Ozonized Water

  • Tanaka, Mutsumi;Kim, Han-Joo;Kim, Tae-Il;Park, Soo-Gil
    • 전기화학회지
    • /
    • 제11권3호
    • /
    • pp.135-140
    • /
    • 2008
  • An electrochemical generation of ozonized water was investigated by using ${\beta}-PbO_2$ as an anode and tap water as an anolyte. According to the potentiometric ozone detection which utilizes potential differences arisen from a chemical reaction of ozone and iodide, increasing tendency of ozone concentration on electrolysis time could be observed to show the maximum value of 8 ppm at an electrolysis time of 10 min. Ozone could be generated promptly even at an electrolysis time of 10 sec., suggesting great advantages of this electrochemical process in terms of simplicity and readiness that might be applied directly to practical uses including medical and/ or food industries. Influences of electrolysis on the properties and surface conditions of a $PbO_2$ electrode were also discussed from the results of cyclic voltammetry, scanning electron microscope, and X-ray diffractometer.

Potentiometric Characteristics of Ion-Selective Electrodes Based on Upper-Rim Calix[4]crown Neutral Carrier

  • 강유라;오현준;이경문;차근식;남학현;백경수;임혜재
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권2호
    • /
    • pp.207-211
    • /
    • 1998
  • Potentiometric characteristics of DOS plasticized PVC-based membranes containing upper-rim calix[4]crown neutral carrier to various metal cations and protonated alkylamines have been examined. Although the calix[4]crown-based membrane electrodes exhibited substantial emf responses to alkali and alkaline earth metal cations, their high detection limits (- log[Cs+]=4.5) and sub-Nernstian response slopes (48 mV/pCs+) to the most selective cation, cesium, indicate that the metal cation complexing ability of calix[4]crown is much weaker than that of macrocyclic crown ethers. However, the calix[4]crown-based membrane electrodes exhibited near-Nernstian response slopes (56 mV/decade for hexylNH3+) with low detection limits (log[hexylNH3+]= - 6.7) to most alkylammonium ions compared to those of blank (DOS plasticized PVC membrane with no ionophore) or crown ether-based membranes. While the selectivity patterns of blank and crown ether-based membranes are determined primarily by the lipophilicity of alkylammonium ions, the membranes doped with calix[4]crown ionophore could effectively discriminate the steric shapes of nonpolar alkyl groups of alkylammonium ions.

Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects

  • Seo, Hyung-Ran;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권10호
    • /
    • pp.1484-1488
    • /
    • 2004
  • The thiocyanate-selective PVC membrane electrodes based on 5,10,15,20-tetrakis(2,4,6-trimethylphenyl)-porphyrinatomanganese(III) chloride [Mn(TMP)Cl] and 5,10,15,20-tetrakis(2,6-dichlorophenyl)porphyrinatomanganese(III) chloride $[Mn(Cl_8TPP)Cl]$ as ion carriers were investigated. The effect of ionophores, membrane compositions, plasticizers, and solution pHs on the response characteristics were studied. The Mn(TMP)Cl as an ionophore shows the best potentiometric sensitivity with a slope of -58.7 mV/decade and a detection limit of $log[SCN^-]$ = -6.90, and selectivity for thiocyanate over strong hydrophobic interfering anions such as ${ClO_4}^-$ and salicylate. The potentiometric response is affected by the electronic effect of the substituents and solution pHs. The presence of substituents with electron donating and more liphophilic characters around the ligated metal center produces an improved response toward $SCN^-$.

Ammonium Ion Binding Property of Naphtho-Crown Ethers Containing Thiazole as Sub-Cyclic Unit

  • Kim, Hong-Seok;Do, Kyung-Soon;Kim, Ki-Soo;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권10호
    • /
    • pp.1465-1470
    • /
    • 2004
  • A short and efficient synthesis, solvent extraction and potentiometric measurements of new thiazole-containing naphtho-crown ethers are reported. The naphthalene moiety enhances the ammonium ion selectivity over potassium ion. The selectivity of ${NH_4}^+/K^+$ follows the trend $3\;{\approx}\;2\;>\;1$, indicating that the differences in conformational changes of 2 and 3 in forming ammonium complexes affect little on the resulting ammonium/potassium extraction selectivity ratio. The ammonium ion-selective electrodes were prepared with noctylphenyl ether plasticized poly(vinyl chloride) membranes containing 1-4 the effect of one naphthalene unit introduced on either right (2) or left (3) side of thiazolo-crown ether on their potentiometric properties (e.g., ammonium ion selectivity over other cations, response slopes, and detection limits) were not apparent. However, the ammonium ion selectivity of 1, 2 and 3 over other alkali metal and alkaline earth metal cations is 10-100 times higher than that of nonactin.