• Title/Summary/Keyword: Potential rise

Search Result 656, Processing Time 0.025 seconds

The Potential Interference between Ground Rod and Counterpoise (봉상 접지전극-수평매설 접지전극 상호간의 전위간섭)

  • Lee, Bok-Hee;Lee, Su-Bong;Jeong, Dong-Cheol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.351-354
    • /
    • 2006
  • This paper deals with the potential interferences between ground rod and counterpoise. The ground potential rise and coefficient of potential interference were measured by using the hemispherical water tank grounding simulator and calculated from CDEGS program as functions of the configuration and size of grounding electrodes and the distance between grounding electrodes. The ground potential un and potential interference coefficient strongly depend on the distance between grounding electrodes, the arrangement and size of grounding electrodes.

  • PDF

Study of Touch and Step Voltages with Grounding Grid Using Electrolytic Tank and Analysis Program

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kill, Gyung-Suk
    • International Journal of Safety
    • /
    • v.9 no.2
    • /
    • pp.1-5
    • /
    • 2010
  • In order to analyze the potential rise of ground surface of grounding grid installed in buildings, the grounding simulator has been designed and fabricated as substantial and economical measures. This paper describes the study of touch and step voltages with grounding grid where earth leakage current is injected. To assess risk voltage of grounding grid, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of an electrolytic tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the touch voltage and step voltage above the grounding grid were very low, but were significantly increased near the edge of grounding grid.

A Study on Separation Distance Calculation Model for Limitation of Earth Potential Rise nearby Tower Footings (송전철탑 부근의 대지전위 억제를 위한 이적거리 산정모델 연구)

  • Choi, Jong-Kee;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.212-213
    • /
    • 2007
  • In case of a line-to-ground fault at transmission lines, a portion of fault current will flow into the earth through the footings of the faulted tower causing electrical potential rise nearby the faulted tower footings. In this situation, any buried pipelines or structures nearby the faulted tower can be exposed to the electrical stress by earth potential rise. Although many research works has been conducted on this phenomena, there has been no clear answer of the required separation distance between tower footings and neary buried pipeline because of its dependancy on the soil electrical charactersics of the concerned area and the faulted system. In this paper, an analytical formula to calculate the requried sepeartion distance from the faulted tower has been derived.

  • PDF

Analysis of Transient Potential Rises of Horizontal Ground Electrodes Considering the Frequency-Dependent of Soil (토양의 주파수의존성을 고려한 정보통신설비용 수평접지전극의 과도전위상승 분석)

  • Ahn, Chang Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.147-153
    • /
    • 2016
  • The lightning protection of information and communication facilities is very important factor to improve a reliability of the action of these equipment. Especially the transient potential rise of ground electrode being injected with the lightning current is to be a basic data of the dielectric strength for both power and communication facilities so that more accurate analysis should be required. The transient potential rise can be calculated from the ground impedance and the ground impedance is strongly dependent upon the shape of the ground electrode and the frequency-dependence of soil. The Debye's equation which is able to calculate the characteristics of dielectrics is used to analyze the frequency-dependent of soil. Also, the method to calculate the transient potential rise from the ground impedance is specified in this paper. In order to analyze the transient potential rise resulting from calculations with Debye's equation, TLM(transmission line method) and case of ${\rho}$(resistivity)-constant are simulated, respectively. The length of a horizontal ground electrode is 30 m and simulations were performed at 10, 100, $1000{\Omega}{\cdot}m$ with the standard lightning current waveform. In result, the transient potential rise of horizontal ground electrode calculating with Debye's equation is lower than it of other models.

Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems (측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정)

  • Lee, Bok-Hui;Eom, Ju-Hong;Kim, Seong-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

Evaluations on the Potential Interferences between Ground Rods (봉상 접지전극 상호간의 전위간섭에 대한 평가)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Kil, Hyung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.92-98
    • /
    • 2006
  • This paper deals with the potential interferences between ground rods. To propose a method for reducing the potential interference caused by grounding electrodes, the theoretical analysis and the reduced scale model tests, which we related to the measurement and computation of ground potential rise and potential interference caused by actual-sized grounding electrodes where current is injected, were carried out. The ground potential rise and potential interference coefficients were measured by using the hemispherical water tank grounding simulator and calculated by CDEGS software as a function of the distance between grounding electrodes. The ground potential rises and potential interference coefficients strongly depend on the distance between grounding electrodes, and the measured results were compared with the computer calculated data and were known in good agreement.

A Study on the Measurement of Grounding Resistance based on the Earth Surface Potential Analysis (지표면전위 해석에 의한 접지저항 측정기법에 관한 연구)

  • 윤장완;안용호;정길조;한병성
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.117-123
    • /
    • 2002
  • Measurement of ground resistance is the basic and important procedure to evaluate the proriety of grounding systems performance. In the field, however, it is not an easy task to measure ground resistance accurately, because locating a right position of zero potential for accurate GPR(Ground Potential Rise) measurement is very difficult, especially in case of a grounding electrode with large dimension. In this paper, the estimation method of ground resistance by analysing earth surface potential distribution around the grounding electrodes has been described.

A Research on the Solution of the Potential Interferences of Isolation Grounding Systems (독립접지방식의 전위간섭 문제 해결을 위한 연구)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Kil, Hyung-Jun;Han, Woon-Ki;Kim, Hyo-Jin;Lee, Hyung-Kyon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.49-51
    • /
    • 2005
  • This paper presents the potential interferences in various grounding electrode systems. The ground potential rise and potential interference coefficients were calculated as a function of the configuration and size of grounding electrodes and the distance between grounding electrodes. The potential rise and potential interference coefficient strongly depend on the distance between grounding electrodes, the shape and size of grounding electrodes.

  • PDF

An Analysis of Influence Between the Power Feeding Line Insulation and Negative Rail Potential for the DC Ground Fault Protection in the Rubber Wheel System (고무차륜시스템에서의 지락보호를 위한 급전선로 절연과 부극전위와의 영향 분석)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Young;Cho, Sanghoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.577-583
    • /
    • 2013
  • We have analyzed influence of potential rise in negative bus, which caused by decrease of power feeding line insulation, upon protecting method of DC ground protection device which detecting potential rise between negative bus and ground in order to detect ground fault in the rubber wheel system. For this purpose, we proposed negative potential equation between negative bus and ground and calculated negative potential according to system condition changes by estimating power feeding line insulation changes in steel wheel system and rubber wheel system, and equalizing DC power feeding system when ground fault occurred. Also, in order to estimate negative potential of real system, we modeled the rubber wheel system, and simulated normal status, grounding fault occurrence and power feeding line insulation changes. In normal status, negative potential did not rise significantly regardless of vehicle operation. When ground fault occurred, negative potential rose up over 300V regardless of fault resistance. However, we also observed that negative potential rose when power feeding line insulation dropped down under $1M{\Omega}$. In conclusion, our result shows that in case of rubber wheel system unlike steel wheel system, relay will be prevented maloperation and insulation status observation can be ensured when ground over voltage relay will be set 200V ~ 300V.

Environmental Impact Characteristics Analysis of High-rise Structural System Based on Life Cycle Assessment (전과정평가 기법에 기반한 고층구조시스템의 환경영향특성 분석)

  • Kim, Rak-Hyun;Kim, Young-Hwa;Roh, Seung-Jun;Park, Sang-Hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.4
    • /
    • pp.71-79
    • /
    • 2022
  • Recently, the construction of tall buildings utilized by high strength-concrete in the whole world is tending to be on the rise. The application of high-rise structural system in buildings results in the excellent cut-down effect in construction materials due to section reduction. Therefore, in order to investigate the CO2 and resource reduction effect for the high-rise structural system, comparisons of GWP and ADP in embodied energy of structural materlais between 4 type of high-rise structural system have been performed. As a result, GWP emission increased in the order of steel structure outrigger system, RC shear wall system, and RC outrigger system. On the other hand, ADP emissions increased in the order of RC shear wall system, RC outrigger system, and steel structure outrigger system.