• Title/Summary/Keyword: Potential of electrode

Search Result 1,283, Processing Time 0.023 seconds

Studies on the Electrochemical Properties of Oxygen Adducts Tetradentate Schiff Base Cobalt (Ⅱ) Complexes in Aprotic Solvents (Ⅱ) (비수용매에서 네자리 Schiff Base Cobalt (II) 착물들의 산소첨가 생성물에 대한 전기화학적 성질에 관한 연구 (제 2 보))

  • Ki-Hyung Chjo;Jin-Soon Chung;Heui-Suk Ham;Seoing-Seob Seo
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.192-202
    • /
    • 1989
  • Tetradentate schiff bases cabalt (II) complexes; Co(SED) and Co(ο-BSDT) were synthesized and these complexes allowed to reaction with dry oxygen to form oxygen adduct cobalt(III) complexes such as $[Co(o-BSDT)(DMSO)]_2O_2,\;[Co(SED)(Py)]_2O_2\;and\;[Co(o-BSDT)(Py)]_2O_2$ in DMSO and pyridine solutions. It has been found that the oxygen adduct cobalt(III) complexes have hexacoordinated octahedral configuration with tetradentate schiff base cobalt(II), DMSO or pyridine and oxygen, and the mole ratio of oxygen to cobalt(II) complexes are 1:2. The redox processes, were investigated for Co(SEDT) and Co(ο-BSD) complexes in 0.1M TEAP-DMSO and 0.1M TEAP-pyridine by cyclic voltammetry with glassy carbon electrode. As a result the redox processes of Co(II)/Co(III) and Co(II)/Co(I) found to be reversible or quasi-reversible for non uptake oxygen complexes but oxygen adduct complexes found to be irreversible processes and reaction processes of oxygen for oxygen adduct complexes are quasi-reversible process, the potential range was $E_{pc}=-0.85{\sim}-1.19V\;and\;E_{pa}=-0.74{\sim}-0.89V$.

  • PDF

An Analysis on the Over-Potentially Deposited Hydrogen at the Polycrystalline $Ir/H_2SO_4$ Aqueous Electrolyte Interface Using the Phase-Shift Method (위상이동 방법에 의한 다결정 $Ir/H_2SO_4$ 수성 전해질 계면에서 과전위 수소흡착에 관한 해석)

  • Chun Jagn Ho;Mun Kyeong Hyeon
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.2
    • /
    • pp.109-114
    • /
    • 2000
  • The relation between the phase-shift profile fur the intermediate frequencies and the Langmuir adsorption isotherm at the poly-Ir/0.1 M $H_2SO_4$ aqueous electrolyte interface has been studied using ac impedance measurements, i.e., the phase-shift methods. The simplified interfacial equivalent circuit consists of the serial connection of the electrolyte resistance $(R_s)$, the faradaic resistance $(R_F)$, and the equivalent circuit element $(C_P)$ of the adsorption pseudoca-pacitance $(C_\phi)$. The comparison of the change rates of the $\Delta(-\phi)/{\Delta}E\;and\;\Delta{\theta}/{\Delta}E$ are represented. The delayed phase shift $(\phi)$ depends on both the cathode potential (E) and frequency (f), and is given by $\phi=tan^{-1}[1/2{\pi}f(R_s+R_F)C_P]$. The phase-shift profile $(-\phi\;vs.\;E)$ for the intermediate frequency (ca. 1 Hz) can be used as an experimental method to determine the Langmuir adsorption isotherm $(\theta\;vs.\;E)$. The equilibrium constant (K) for H adsorption and the standard free energy $({\Delta}G_{ads})$ of H adsorption at the poly-Ir/0.1 M $H_2SO_4$ electrolyte interface are $2.0\times10^{-4}$ and 21.1kJ/mol, respectively. The H adsorption is attributed to the over-potentially deposited hydrogen (OPD H).

Response Properties of Meridians for focused variable electromagnetic stimulus (접속형 가변 전자계 자극에 대한 경락반응특성)

  • Lee, Gyoun-Jung;Cho, Dong-Guk;Kim, Soo-Byung;Kwon, Sun-Min;Shin, Tae-Min;Lee, Kyoung-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1399-1410
    • /
    • 2009
  • It is a method to treat pain using medication, neurotomy, and surgery. And acupuncture, ultrasound, electric treatment, and magnetic treatment are applied as a alternative physiotherapy. Electronic therapy is useful but it can be affected by impedance of skin or subcutaneous tissue. So, percutaneous stimulation is leading therapy, that is very randomly. We developed the system which can stimulate parts of acupuncture point noninvasively using the focused magnetic field. And we designed the magnetic stimulation electrode which is considered efficiency of the magnetic stimulation. It can make similar stimulation with manual acupuncture. To confirm the availability and reliability we compared Meridian Electronic Potential(MEP) change between manual acupuncture and magnetic stimulation. From this result, we found out the MEP changes of manual acupuncture and magnetic stimulation were similar. And there were various response properties as changes of stimulation method, intensity, and frequency. Also, the MEP change can be induced by electromagnetic stimulation. We confirmed that it is possible to use electromagnetic stimulation as a acupoint stimulation or pain treatment instrument.

The Relation between the Phase-Shift Profile for the Intermediate Frequencies and the Langmuir Adsorption Isotherm (중간주파수에서 위상이동 변화와 Langmuir흡착등온식 사이의 관계)

  • Chun Jang Ho;Mun Kyeong Hyeon;Cho Chong Dug
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.1
    • /
    • pp.25-30
    • /
    • 2000
  • The relation between the phase-shift profile for the intermediate frequencies and the Langmuir adsorption isotherm at the poly-$Pt/0.1\;M\;H_2SO_4$ aqueous electrolyte interface has been studied using ac impedance measurements, i.e., the phase-shift methods. The suggested interfacial equivalent circuit consists of the serial connection of the electrolyte resistance ($R_S$), the faradaic resistance $(R_F)$ and the equivalent circuit element $(C_P)$ of the adsorption pseudocapacitance $(C_\varphi)$. The delayed phase shift $(\varphi)$ depends on both the cathode potential (E) and frequency (f), and is given by $\varphi=-tan^{-1}[1/2{\pi}f(R_s+R_F)C_p]$. The phase-shift profile $(\varphi\;vs.\;E)$ for the intermediate frequency (ca. 6Hz) can be used as an experimental method to determine the Langmuir adsorption isotherm (9 vs. E). The equilibrium constant (K) for H adsorption and the standard free energy $({\Delta}G_{ads})$ of H adsorption at the poly-$Pt/0.1\;M\;H_2SO_4$ electrolyte interface are $1.8\times10^{-4}\;and\;21.4kJ/mol$, respectively. The H adsorption is attributed to the over-potentially deposited hydrogen (OPD H).

The Langmuir Adsorption Isotherms of the Electroadsorbed Hydrogens at the Single Crystal Pt(100)/Aqueous Electrolyte Interfaces (단결정 Pt(100)/수용액 계면에서 전가흡착된 수소의 Langmuir흡착등온식)

  • Chun Jang Ho;Jeon Sang Kyoo
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.1
    • /
    • pp.14-20
    • /
    • 2001
  • The Langmuir adsorption isotherms of the under-potentially deposited hydrogen (UPD H) and the over-potentially deposited hydrogen (OPD H) at the single crystal Pt(100)/0.5 M $H_2SO_4$ and 0.5 M LiOH aqueous electrolyte interfaces have been studied using the phase-shift method. The phase-shift profile $({-\varphi}\;vs.\;E)$ for the optimum intermediate frequency can be used as a useful method to estimate the Langmuir adsorption isotherm $(\theta\;vs.\;E)$ at the interfaces. The equilibrium constant (K) for the OPD H and the standard free energy $({\Delta}G_{ads})$ of the OPD H at the Pt(100)/0.5M $H_2SO_4$ aqueous electrolyte interface are $1.5\times10^{-4}$ and 21.8 kJ/mol, respectively. At the Pt(100)/0.5 LiOH aqueous electrolyte interface, K transits from 1.9(UPD H) to $6.8\times10^{-6}$(OPD H) depending on the cathode potential (E) and vice versa. Similarly, ${\Delta}G_{ads}$ transits -1.6 kJ/mol (UPD H) to 29.5 kJ/mol (OPD H) depending on E and vice versa. The transition of K and ${\Delta}G_{ads}$ is attributed to the two distinct adsorption sites of the UPD H and OPD H on the Pt(100) surface. The UPD H and the OPD H at the Pt(100) interfaces are the independent processes depending on the H adsorption sites rather than the sequential processes for the cathodic $H_2$ evolution reactions.

Emotion-on-a-chip(EOC) : Evolution of biochip technology to measure human emotion (감성 진단칩(Emotion-on-a-chip, EOC) : 인간 감성측정을 위한 바이오칩기술의 진화)

  • Jung, Hyo-Il;Kihl, Tae-Suk;Hwang, Yoo-Sun
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.157-164
    • /
    • 2011
  • Emotion science is one of the rapidly expanding engineering/scientific disciplines which has a major impact on human society. Such growing interests in emotion science and engineering owe the recent trend that various academic fields are being merged. In this paper we propose the potential importance of the biochip technology in which the human emotion can be precisely measured in real time using body fluids such as blood, saliva and sweat. We firstly and newly name such a biochip an Emotion-On-a-Chip (EOC). EOC consists of biological markers to measure the emotion, electrode to acquire the signal, transducer to transfer the signal and display to show the result. In particular, microfabrication techniques made it possible to construct nano/micron scale sensing parts/chips to accommodate the biological molecules to capture the emotional bio-markers and gave us a new opportunities to investigate the emotion precisely. Future developments in the EOC techniques will be able to help combine the social sciences and natural sciences, and consequently expand the scope of studies.

  • PDF

Photoeletrochemical Properties of α-Fe2O3 Film Deposited on ITO Prepared by Cathodic Electrodeposition (음극전착법을 이용한 α-Fe2O3 막의 광전기화학적특성)

  • 이은호;주오심;정광덕;최승철
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.9
    • /
    • pp.842-848
    • /
    • 2003
  • Semiconducting $\alpha$-Fe$_2$O$_3$ film was prepared by the cathodic electrodeposition method on Indium Tin Oxide (ITO) substrate for photoelectrochemical cell application. After heat treatment at 50$0^{\circ}C$, the phase was changed from Fe to $\alpha$-Fe$_2$O$_3$. The phase, morphology, absorbance, and photocurrent density (A/$\textrm{cm}^2$) of the film depended on the preparation conditions: deposition time, applied voltage, and the duration of heat treatment. The $\alpha$-Fe$_2$O$_3$ film was characterized by X-Ray Diffractometer (XRD), Scanning Electron Microscope (SEM), and UV -Visible Spectrophotometer. The stability of the $\alpha$-Fe$_2$O$_3$ film in aqueous solution was tested at zero bias potential under the white-light source of 100 mW/$\textrm{cm}^2$. The apparent grain size of the films formed at -2.0 V was larger than that grown at -2.5 V. The $\alpha$-Fe$_2$O$_3$ film deposited at -2.0 V for 180 s and heat-treated at 50$0^{\circ}C$ for 1 h showed the predominant photocurrent of 834$\mu$A/$\textrm{cm}^2$.

Effects of Ouabain and Vanadate on the Spontaneous Contractions and Electrical Activity in Guinea-pig Taenia Coli (결장뉴 전기활동도에 대한 Ouabain과 Vanadate의 작용)

  • Park, Jong-Kyou;Kim, Ki-Whan;So, In-Suk
    • The Korean Journal of Physiology
    • /
    • v.22 no.2
    • /
    • pp.189-206
    • /
    • 1988
  • The effects of ouabain on the contractile and electrical activities were investigated in the isolated preparations of guinea-pig taenia coli, and compared with those of vanadate. Spontaneous contractions were recorded with force transducer, and electrical activites were measured by use of suction electrode, or single sucrose-gap technique. The contractions were induced by the electrical stimulation for 5 seconds every 1 minute with alternating current (60 Hz, 3.0 V/cm) through the platinum electrodes located in parallel with the long axis of the preparation. All experiments were performed in tris-buffered Tyrode solution which was aerated with $100%{\;}O_2$ and kept at $35^{\circ}C$. The results obtained were as follows: 1) Responses of spontaneous contractions to ouabain were concentration-dependent; $10^{-7}M$ ouabain caused a rise of basal tone. Above the concentration of $10^{-6}M$ ouabain, an initial increase followed by a decrease in tension was observed. 2) A continuous spike discharge was induced by the administration of $10^{-7}M$ ouabain. Above $10^{-6}M$ ouabain, a transient initial increase followed by a decrease in spike frequency and amplitude was produced, and finally membrane potential was sustained at a certain level without a spike discharge. 3) The characteristic response to $10^{-7}M$ ouabain was not blocked by the pretreatment with $10^{-7}M$ atropine. 4) The electrically induced contractions were completely suppressed at the concentration of $2{\times}10^{-7}M$ ouabain. These contractions were blocked more rapidly in paralled with the increase in ouabain concentration. 5) Effects of vanadate on the spontaneous activities were quite different from those of ouabain; $10^{-6}M$ vanadate increased the amplitude of contractions and $10^{-5}M$ vanadate increased slightly both amplitude and frequency of spontaneous contractions. $10^{-4}M$ vanadate showed irregular phasic contractions superimposed on the increased basal tone. 6) $10^{-5}M$ vanadate depolarized the membrane potential and shortened the interval between the bursts of spike discharge, whereas $10^{-4}M$ vanadate induced continuous spike discharge with membrane depolarization. 7) Vanadate caused a characteristic inhibitory response to the contractions induced by electrical stimulation; An initial rapid inhibition of tension development and then gradual recovery to a certain level. From the above results, the following conclusions could be made: 1) The rise of basal tone at $10^{-7}M$ ouabain is due to continuous spike discharge without a silent period. The continuous spike discharge is likely to be associated with a slight membrane depolarization caused by the blockage of Na pump. 2) The biphasic response induced by above $10^{-6}M$ ouabain seems to occur by the different mechanisms. The initial increase in tension is associated with depolarization along with an increase in spike frquency, whereas the subsequent relaxation occurs through a non-electrical mechanism. 3) The characteristic response to $10^{-7}M$ ouabain is resulted not from the action on intrinsic nerve terminal, but from its direct action on the membrane of smooth muscle cells. 4) The phasic contractions superimposed on the increased basal tone at the concentration of $10^{-4}M$ vanadate is resulted from the continuous spike discharge with membrane depolarization, of which mechanism remains unknown. 5) The inhibitory action of ouabain on the electrically induced contractions suggests that the increasein intracellular Na in some way inhibits the electrically induced $Ca^{2+}$ influx. The mechanism of vanadate action on the induced contractions remains unknown.

  • PDF

Response of Electrocardiogram of Nile tilapia, Oreochromis niloticus to Light Stimuli (광자극에 대한 역돔의 심전도)

  • Kim, Young-Ki;Yang, Yong-Rhim
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The authors examined the response of electrocardiogram(ECG) of Nile tilapia, Oreochromis niloticus [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli(10, 100 and 400 lu$\chi$) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes in 16~18$^{\circ}C$. The results which are divided into by day and by night and then analyzed by fishes' conditions are as follows; 1. Nile tilapias reached a stable condition 3 minutes after anesthesia. In stable condition, the heart rate average was 47.6beat/min by day and 45.1beat/min by night. And the action potential average was 1.0.4$mutextrm{V}$ by day and 1.24$mutextrm{V}$ by night. 2. The heart rate average by three levels of light stimuli was, \circled1 In stimulus condition, in case of 10 lu$\chi$ 39.7beat/min by day and 38.2beat/min by night, in case of 100 lu $\chi$8.7beat/min by day and 36.9beat/min by night, and in case of 40.0. lux 36.8 beat/min by day and 35.8beat/min by night. \circled2 In recovery condition, in case of 10 lu$\chi$ 47.1beat/min by day and 46.0beat/min by night, in case of 100 lu$\chi$ 47.2beat/min by day and 45.6 beat/min by night, and in case of 400 lu$\chi$ 48.1beat/min by day and 46.6beat/min by night. 3. The action potential average by three levels of light stimuli was, \circled1 In stimulus condition, in case of 10 lu$\chi$ 1.22$mutextrm{V}$ by day and 0.71$mutextrm{V}$ by night, in case of 100 lu$\chi$ 0..63$mutextrm{V}$ by day and 0.90$mutextrm{V}$ by night, and in case of 400 lu$\chi$ 1.39$mutextrm{V}$ by day and 1.63$mutextrm{V}$ by night \circled2 In recovery condition, in case of 10 lu$\chi$ 1.26$mutextrm{V}$ by day and 1.59$mutextrm{V}$ by night, in case of 100 lu$\chi$ 2.63$mutextrm{V}$ by day and 3.65$mutextrm{V}$ by night, and in case of 400. lu$\chi$ 2.52$mutextrm{V}$ by day and 3.67$mutextrm{V}$ by night.

Response of Electrocardiogram of Mirror Carp, Cyprinus carpio to Light Stimuli (광 자극에 대한 향어의 심전도)

  • 양용림;김영기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.124-132
    • /
    • 2001
  • The authors examined the response of electrocardiogram (ECG) of Mirror carp, Cyprinus carpio [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli (10, 100, and 400 lux) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes. The results which are divided into by day and by night and then analyzed by fishes conditions are as follows : 1. Mirror carps reached a stable condition 5 minutes after anesthesia. In this condition, the average heart rate was 64.9 beat/min by day and 65.3 beat/min by night. And the average action potential was 36.9 nV by day and 32.9 nV by night. 2. The average heart rate by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 68.7 beat/min by day and 46.0 beat/min by night, in case of 100 lux 53.4 beat/min by day and 44.1 beat/min by night, and in case of 400 lux 53.2 beat/min by day and 40.1 beat/min by night. 2) In a recovery condition, in case of 10 lux 67.9 beat/min by day and 57.2 beat/min by night, in case of 100 lux 68.8 beat/min by day and 61.0 beat/min by night, and in case of 400 lux 69.6 beat/min by day and 63.6 beat/min by night. 3. The average action potential by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 59.1 nV by day and 24.0 nV by night, in case of 100 lux 26.8 nV by day and 45.6 nV by night, and in case of 400 lux 71.7 nV by day and 14.4 nV by night. 2) In a recovery condition, in case of 10 lux 38.8 nV by day and 27.3 nV by night, in case of 100 lux 29.0 nV by day and 39.3 nV by night, and in case of 400 lux 66.4 nV by day and 21.4 nV by night.

  • PDF