• Title/Summary/Keyword: Posterior fixation

Search Result 259, Processing Time 0.025 seconds

Clinical and MR Predictors of Retro-Odontoid Pseudotumor Regression Following Posterior Fixation in Patients with Atlantoaxial Instability (환축 불안정 환자에서 후방 고정술 후 치상돌기 후방 가성종양 퇴행의 임상 및 자기공명영상 예측 인자)

  • Jisu Kim;Youngjune Kim;Eugene Lee;Joon Woo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.4
    • /
    • pp.754-768
    • /
    • 2024
  • Purpose To identify clinical and MR predictors of retro-odontoid pseudotumor (ROP) regression after posterior fixation in patients with atlantoaxial instability. Materials and Methods We included patients who had undergone posterior fixation for atlantoaxial instability and preoperative and postoperative MR imaging. Patients were classified into two groups according to the degree of ROP regression after posterior fixation: regression (≥ 10% reduction) and no regression (< 10% reduction). Mann-Whitney and Fisher's exact tests were performed to identify the clinical (age and sex) and MR predictors (preoperative ROP thickness, ROP type, MR signal homogeneity of the ROP, spinal cord signal change, spinal cord atrophy, ossified posterior longitudinal ligament, os odontoideum, and atlantodental interval) associated with ROP regression. Results We retrospectively assessed 11 consecutive patients (7 female; median age, 66 years [range, 31-84 years]). Posterior fixation induced ROP regression in eight (72.7%) patients. Older age and greater preoperative ROP thickness significantly correlated with ROP regression (p = 0.024 and 0.012, respectively). All patients with preoperative ROP thickness > 5 mm exhibited ROP regression. The other variables were not significantly associated with ROP regression. Conclusion Older age and thicker preoperative ROP are associated with ROP regression after posterior fixation in patients with atlantoaxial instability.

Posterior Cervical Fixation with Nitinol Shape Memory Loop in the Anterior-Posterior Combined Approach for the Patients with Three Column Injury of the Cervical Spine: Preliminary Report

  • Yu, Dong-Kun;Heo, Dong-Hwa;Cho, Sung-Min;Choi, Jong-Hun;Sheen, Seung-Hun;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.5
    • /
    • pp.303-307
    • /
    • 2008
  • Objective: The authors reviewed clinical and radiological outcomes in patients with three column injury of the cervical spine who had undergone posterior cervical fixation using Nitinol shape memory alloy loop in the anterior-posterior combined approach. Materials: Nine patients were surgically treated with anterior cervical fusion using an iliac bone graft and dynamic plate-screw system, and the posterior cervical fixation using Nitinol shape memory loop ($Davydov^{TM}$) at the same time. A retrospective review was performed. Clinical outcomes were assessed using the Frankel grading method. We reviewed the radiological parameters such as bony fusion rate, height of iliac bone graft strut, graft subsidence, cervical lordotic angle, and instrument related complication. Results: Single-level fusion was performed in five patients, and two-level fusion in four. Solid bone fusion was presented in all cases after surgery. The mean height of graft strut was significantly decreased from $20.46{\pm}9.97mm$ at immediate postoperative state to $18.87{\pm}8.60mm$ at the final follow-up period (p<0.05). The mean cervical lordotic angle decreased from $13.83{\pm}11.84^{\circ}$ to $11.37{\pm}6.03^{\circ}$ at the immediate postoperative state but then, increased to $24.39{\pm}9.83^{\circ}$ at the final follow-up period (p<0.05). There were no instrument related complications. Conclusion: We suggest that the posterior cervical fixation using Nitinol shape memory alloy loop may be a simple and useful method, and be one of treatment options in anterior-posterior combined approach for the patients with the three column injury of the cervical spine.

POSTOPERATIVE STABILITY OF FIXATION WITH ABSORBABLES IN SIMULTANEOUS MAXILLOMANDIBULAR ORTHOGNATHIC SURGERY (상하악 동시 악교정수술에서 흡수성 고정판을 이용한 골편고정시 술후 안정성에 대한 연구)

  • Park, Jung-Min;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.126-131
    • /
    • 2010
  • Objectives: This study is aimed to determine any differences in the postoperative stability between absorbable and titanium plate systems for fixation in orthognathic surgery with simultaneous maxillomandibular procedures especially including maxillary posterior impaction and advancement. Study Design: Forty patients with dentofacial deformities were randomly assigned into titanium (4 males and 6 females) and absorbable (17 males and 13 females) fixation group. All patients had undergone surgical alterations of maxilla with posterior impaction and advancement. A comparison study of the change in the maxillary position after the simultaneous surgery was performed with 1-day, 6-months postoperative lateral cephalograms compared to preoperative lateral cephalogram by tracing. Wilcoxon rank sum test was used for statistical analysis. Result: The position of the maxilla was stable after surgery and was not changed significantly from 1 day to 6 month after the simultaneous maxillomandibular surgery both in the experimental (absorbable plates) and control (titanium plates). Conclusion: This study suggests that application of absorable plating system in the fixation of maxillary segment in the simultaneous maxillomandibular procedures, leads to a predictable short-term postoperative skeletal stability comparable to the titanium plating system. Long term follow-up and further studies will be needed.

Vertical Reduction Using Atlantoaxial Facet Spacer in Basilar Invagination with Atlantoaxial Instability

  • Kim, Il-Sup;Hong, Jae-Taek;Sung, Jae-Hoon;Byun, Jae-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.6
    • /
    • pp.528-531
    • /
    • 2011
  • Although posterior segmental fixation technique is becoming increasingly popular, surgical treatment of craniovertebral junctional disorders is still challenging because of its complex anatomy and surrounding critical neurovascular structures. Basilar invagination is major pathology of craniovertebral junction that has been a subject of clinical interest because of its various clinical presentations and difficulty of treatment. Most authors recommend a posterior occipitocervical fixation following transoral decompression or posterior decompression and occipitocervical fixation. However, both surgical modalities inadvertently sacrifice C0-1 and C1-2 joint motion. We report two cases of basilar invagination reduced by the vertical distraction between C1-2 facet joint. We reduced the C1-2 joint in an anatomical position and fused the joint with iliac bone graft and C1-2 segmental fixation using the polyaxial screws and rods C-1 lateral mass and the C-2 pedicle.

Two-Year Follow-up Results of Anteroposterior Cannulated Screw Fixation of Posterior Malleolar Fragment in the Trimalleolar Fracture (족관절 삼과 골절에서 전후방 유관나사 후과 고정술의 2년 추시 결과)

  • Jung, Sung Yoon;Lee, Myoung Jin;Jung, Young Hun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.2
    • /
    • pp.67-72
    • /
    • 2016
  • Purpose: The purpose of this study was to assess the 2-year follow-up results of patients with a trimalleolar fracture, who had undergone an anterior incision cannulated screw fixation of the posterior malleolar fragment, which had more than 25% of articular involvement or had no cortical continuity with the distal tibia. Materials and Methods: Among 28 patients with a trimalleolar fracture who had undergone fixation of the posterior malleolar fragment between February 2005 and February 2010, 14 patients, who underwent an anterior incision cannulated screw fixation of posterior malleolar fragment and were followed-up for more than 2 years, were selected. The postoperative clinical and radiological findings immediately and at the 1- and 2-year follow-up were compared. The clinical findings were evaluated as American Orthopaedic Foot and Ankle Society (AOFAS) score. The radiological assessment was evaluated as the maintenance of reduction, period to bone union, and the presence of nonunion, malunion, and complications. Results: The clinical outcome by mean AOFAS score revealed 83.0 points in the group with preoperative displacement below 2 mm and 80.7 points in the group with preoperative displacement above 2 mm postoperatively. The mean AOFAS score was 91.7 and 93.1 points in the group with preoperative displacement below 2 mm on 1- and 2-year follow-up, respectively, and 89.8 and 91.7 points in group with the preoperative displacement above 2 mm on 1- and 2-year follow-up, respectively. After a 2-year follow-up among 14 cases selected for this study, 13 cases showed an excellent reduction state and only 1 case (7.1%) showed a displacement of more than 2 mm. No complication were encountered in the group with preoperative displacement below 2 mm. On the other hand, among 8 patients in the group with preoperative displacement above 2 mm, there were 3 with limitations of the range of motion of the ankle joint (37.5%) and 1 post-traumatic arthritis (12.5%) at the 2-year follow-up. Conclusion: Anterior incision cannulated screw fixation of the posterior malleolar fragment could be a valuable method for the treatment of trimalleolar fractures that provides satisfactory results.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

The Use of Pedicle Screw-Rod System for the Posterior Fixation in Cervico-Thoracic Junction

  • Cho, Won-ik;Eid, Ahmed Shawky;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • Objective : In cervico-thoracic junction (CTJ), the use of strong fixation device such as pedicle screw-rod system is often required. Purpose of this study is to analyze the anatomical features of C7 and T1 pedicles related to screw insertion and to evaluate the safety of pedicle screw insertion at these levels. Methods : Nineteen patients underwent posterior CTJ fixation with C7 and/or T1 included in fixation levels. Seventeen patients had tumorous conditions and two with post-laminectomy kyphosis. The anatomical features were analyzed for C7 and T1 pedicles in 19 patients using computerized tomography (CT). Pedicle screw and rod fixation system was used in 16 patients. Pedicle violation by screws was evaluated with postoperative CT scan. Results : The mean values of the width, height, stable depth, safety angle, transverse angle, and sagittal angle of C7 pedicles were $6.9{\pm}1.34\;mm$, $8.23{\pm}1.18\;mm$, $30.93{\pm}4.65\;mm$, $26.42{\pm}7.91$ degrees, $25.9{\pm}4.83$ degrees, and $10.6{\pm}3.39$ degrees. At T1 pedicles, anatomic parameters were similar to those of C7. The pedicle violation revealed that 64.1% showed grade I violation and 35.9% showed grade II violation, overall. As for C7 pedicle screw insertion, grade I was 61.5% and grade II 38.5%. At T1 level, grade I was 65.0% and grade II 35.0%. There was no significant difference in violation rate between the whole group, C7, and T1 group. Conclusion : C7 pedicles can withstand pedicle screw insertion. C7 pedicle and T1 pedicle are anatomically very similar. With the use of adequate fluoroscopic oblique view, pedicle screw can be safely inserted at C7 and T1 levels.

Concomitant Fracture of Lateral Process and Posteromedial Tubercle of Talus (A Case Report) (거골의 외측 돌기와 후방 돌기 내측 결절의 동반 골절(1예 보고))

  • An, Ki-Young;Lee, Jun-Young;Yu, Jae-Cheul
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.233-235
    • /
    • 2009
  • Concomitant fracture of medial tubercle of posterior process and lateral process of the talus has not been reported in Korean literature. Association between fracture of lateral and posterior process of talus is not clear. We treated with open reduction and screw fixation in fracture of lateral process and with excision of fragment of posteromedial tubercle of posterior process with satisfying result.

  • PDF

Clinical Significance of Lateral Ankle Radiograph after the Reduction of a Syndesmosis Injury (원위경비인대결합 손상 정복 후 관찰된 측면 방사선 영상의 임상적 중요성)

  • Suh, Jae Wan;Park, Hyun-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.128-134
    • /
    • 2017
  • Purpose: To introduce reliable and newly developed radiographic measures based on a lateral ankle radiograph to assess a syndesmotic reduction after screw fixation and to compare with the radiographic measures based on the anteroposterior (AP) and mortise radiographs. Materials and Methods: The postoperative ankle radiographs of 34 ankle fracture cases after screw fixation for concurrent syndesmosis injury were reviewed. Two radiographic parameters were measured on each AP and mortise radiograph; tibiofibular clear space (TFCS) and tibiofibular overlap (TFO). Five radiographic parameters were measured on the true lateral radiographs; the anteroposterior tibiofibular (APTF) ratio, anterior tibiofibular ratio (ATFR), posterior tibiofibular ratio (PTFR), distances of intersection of the anterior fibular border and the tibial plafond to anterior cortex of the tibia (AA'), and the intersection of posterior fibular border and tibial plafond to the tip of the posterior malleolus (BB'). In addition, the distance (XP) between the fibular posterior margin (X) crossing tibial plafond or the posterior malleolus and posterior articular margin (P) of the tibial plafond was measured on the lateral view. Results: Using TFCS and TFO in the AP and mortise radiographs, malreductions of syndesmosis were estimated in 17 of 34 cases (50.0%). Using the introduced and developed radiographic measures in the lateral radiographs, syndesmotic malreductions were estimated in 16 out of 34 cases (47.1%). Seventeen cases (50.0%) showed no evidence of postoperative diastasis using the radiographic criteria on the AP and mortise view, 10 cases (58.8%) of whom showed evidence of a malreduction on the lateral radiograph. The newly developed measurements, XP, were measured 0 in 11 out of 34 cases (32.4%). Conclusion: The reduction of syndemosis after screw fixation can be accurately assessed intraoperatively with a combination of several reliable radiographic measurements of the lateral radiograph and traditional radiographic measurements of the AP and mortise radiograph.

A Biomechanical Comparison among Three Surgical Methods in Bilateral Subaxial Cervical Facet Dislocation

  • Byun, Jae-Sung;Kim, Sung-Min;Choi, Sun-Kil;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.2
    • /
    • pp.89-95
    • /
    • 2005
  • Objective: The biomechanical stabilities between the anterior plate fixation after anterior discectomy and fusion (ACDFP) and the posterior transpedicular fixation after ACDF(ACDFTP) have not been compared using human cadaver in bilateral cervical facet dislocation. The purpose of this study is to compare the stability of ACDFP, a posterior wiring procedure after ACDFP(ACDFPW), and ACDFTP for treatment of bilateral cervical facet dislocation. Methods: Ten human spines (C3-T1) were tested in the following sequence: the intact state, after ACDFP(Group 1), ACDFPW(Group 2), and ACDFTP(Group 3). Intervertebral motions were measured by a video-based motion capture system. The range of motion(ROM) and neutral zone(NZ) were compared for each loading mode to a maximum of 2.0Nm. Results: ROMs for Group 1 were below that of the intact spine in all loading modes, with statistical significance in flexion and extension, but NZs were decreased in flexion and extension and slightly increased in bending and axial rotation without significances. Group 2 produced additional stability in axial rotation of ROM and in flexion of NZ than Group 1 with significance. Group 3 provided better stability than Group 1 in bending and axial rotation, and better stability than Group 2 in bending of both ROM and NZ. There was no significant difference in extension modes for the three Groups. Conclusion: ACDFTP(Group 3) demonstrates the most effective stabilization followed by ACDFPW(Group 2), and ACDFP(Group 1). ACDFP provides sufficient strength in most loading modes, ACDFP can provide an effective stabilization for bilateral cervical facet dislocation with a brace.