• Title/Summary/Keyword: Post-failure behavior

Search Result 142, Processing Time 0.025 seconds

Some Characteristics of Anisotropic Conductive and Non-conductive Adhesive Flip Chip on Flex Interconnections

  • Caers, J.F.J.M.;De Vries, J.W.C.;Zhao, X.J.;Wong, E.H.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.3
    • /
    • pp.122-131
    • /
    • 2003
  • In this study, some characteristics of conductive and non-conductive adhesive inter-connections are derived, based on data from literature and own projects. Assembly of flip chip on flex is taken as a carrier. Potential failure mechanisms of adhesive interconnections reported in literature are reviewed. Some methods that can be used to evaluate the quality of adhesive interconnections and to evaluate their aging behavior are given. Possible finite element simulation approaches are introduced and the required critical materials properties are summarized. Response to temperature and moisture, resistance to reflow soldering and resistance to rapid change in temperature and humidity are elaborated. The effect of post cure during accelerated testing is discussed. This study shows that only a combined approach using finite element simulations, and use of appropriate experimental evaluation methods can result in revealing, understanding and quantifying the complex degradation mechanisms of adhesive interconnections during aging.

Post-liquefaction Behavior under Monotonic Loading of a Silty Sand (실트질 모래의 액상화 후의 정적거동)

  • 강병희;박근보;강대성
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.27-36
    • /
    • 2000
  • 보통으로 다져진(Dr=50%)실트질 모래의 액상화 후의 비배수정적거동과 이에 대한 압밀응력비의 영향에 관해서 연구하기 위하여 4가지 압밀응력비(σhc'/σVC'=1.0,0.7,0.55,K0)로서 압밀시킨 공시체를 액상화 전후상태에서 비배수 삼축시험을 수행하였다. 연구결과 액상화를 경험하지 않은 실트질 모래의 p'-q좌표상의 상전이선과 파괴선은 모두 구속압밀응력과 압밀응력비의 크기에 관계없이 각각 원점을 지나는 하나의 직선으로 나타난다. 또한 상정이전단저항은 구속응력이 클수록 증가하난 동일한 구속응력하에서는 압밀응력비와는 관계없이 거의 동일한 값을 갖는 경향을 나타낸다.

  • PDF

An Experimental Study on Structural Behavior of Concrete Box Girder Member with Transverse Prestressing (PSC 박스거더 교량부재의 횡방향 프리스트레싱에 따른 구조거동 실험연구)

  • Oh Byung Hwan;Choi Young Cheol;Choi Jung Sun;Lee Seong Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.77-80
    • /
    • 2004
  • In bridge deck systems, deflections and cracking can be controlled by longitudinal and transverse prestressing, There are some benefits, longitudinal cracking control, the thickness reduction of deck slab, the widening of deck width and the reduction of the cross section area, in transversely post-tensioned concrete box girder bridges. However, it has been not sufficient to study the structural behaviors of transversely post-tensioned concrete box girder. Therefore, It is needed to predict the structural behaviors by prestressing and static loading. In this study, the analytical and experimental load tests are carried out to study the effect of transverse prestressing on concrete box girder. For these objectives, four test specimens are fabricated with various tendon spacing and steel ratio of top slab. The analytical and experimental studies are performed to estimate effects of the prestressing and failure tests.

  • PDF

Cyclic Behavior of Timber Column Concealed Base Joint

  • Humbert, Jerome;Lee, Sang-Joon;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.123-133
    • /
    • 2013
  • This paper presents experimental and numerical tests on a recently developed timber column concealed base joint. This joint was designed to replace the wood-wood connection found in the post-and-beam structure of Hanok, the traditional Korean timber house. The use of metallic connectors provides an increased ductility and energy dissipation for a better performance under reversed loading, especially seismic. In this study, we investigate the performance of the joint under pseudo-static reversed cyclic moment loading through the study of its ductility and energy dissipation. We first perform experimental tests. Results show that the failure occurs in the metallic connector itself because of stress concentrations, while no brittle fracture of wood occur. Subsequent numerical simulations using a refined finite element model confirm these conclusions. Then, using a practical modification of the joint configuration with limited visual impact, we improve the ductility and energy dissipation of the joint while retaining a same level of rotational strength as the originally designed configuration. We conclude that the joint has a satisfying behavior under reversed moment loading for use in earthquake resistant timber structure in low to moderate seismicity areas like Korea.

Experiments on reinforced concrete beam-column joints under cyclic loads and evaluating their response by nonlinear static pushover analysis

  • Sharma, Akanshu;Reddy, G.R.;Eligehausen, Rolf;Vaze, K.K.;Ghosh, A.K.;Kushwaha, H.S.
    • Structural Engineering and Mechanics
    • /
    • v.35 no.1
    • /
    • pp.99-117
    • /
    • 2010
  • Beam-column joints are the key structural elements, which dictate the behavior of structures subjected to earthquake loading. Though large experimental work has been conducted in the past, still various issues regarding the post-yield behavior, ductility and failure modes of the joints make it a highly important research topic. This paper presents experimental results obtained for eight beam-column joints of different sizes and configuration under cyclic loads along with the analytical evaluation of their response using a simple and effective analytical procedure based on nonlinear static pushover analysis. It is shown that even the simplified analysis can predict, to a good extent, the behavior of the joints by giving the important information on both strength and ductility of the joints and can even be used for prediction of failure modes. The results for four interior and four exterior joints are presented. One confined and one unconfined joint for each configuration were tested and analyzed. The experimental and analytical results are presented in the form of load-deflection. Analytical plots are compared with envelope of experimentally obtained hysteretic loops for the joints. The behavior of various joints under cyclic loads is carefully examined and presented. It is also shown that the procedure described can be effectively utilized to analytically gather the information on behavior of joints.

Structural behavior of partially encased composite columns under axial loads

  • Pereira, Margot F.;De Nardin, Silvana;El Debs, Ana L.H.C.
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1305-1322
    • /
    • 2016
  • This paper presents the results of experimental and numerical model analyses on partially encased composite columns under concentric loads. The main objective of this study is to evaluate the influence of replacing the conventional longitudinal and transverse steel bars by welded wire mesh on the structural behavior of these members under concentric loads. To achieve these goals experimental tests on four specimens of partially encased composite columns submitted to axial loading were performed and the results were promising in terms of replacing the traditional reinforcement by steel meshes. In addition, a numerical FE model was developed using the software DIANA$^{(R)}$ with FX+. The experimental results were used to validate the numerical model. Satisfactory agreement between experimental and numerical results was observed in both capacity and deformability of the composite columns. Despite of the simplifying assumptions of perfect bond between steel and concrete, the numerical model adequately represented the columns behavior. A finite element parametric study was performed and parameters including thickness of the steel profile and the concrete and steel strengths were evaluated. The parametrical study results found no significant changes in the partially encased columns behavior due to variations of the steel profile thickness or yield strength. However, significant changes in the post peak behavior were observed when using high strength concrete and these results suggest a change in the failure mode.

Internal Service Recovery's Influence on Frontline Service Employees' Satisfaction and Loyalty

  • Gong, Taeshik
    • Asia Marketing Journal
    • /
    • v.17 no.2
    • /
    • pp.39-62
    • /
    • 2015
  • Relatively little studies have investigated employee recovery from internal service failure, especially from the employees' perspective. When handling customer complaints, employees must not only deal with legitimate customer demands after a service failure, such as providing an apology, rectifying the problem, and offering compensation, but they must also manage illegitimate dysfunctional customers, who may yell, threaten, and even physically harm the employee. These negative experiences can have strong effects, and employees can exhibit higher levels of stress such as burnout and emotional labor, which have been linked to dissatisfaction, tension and anxiety, reduced performance and effectiveness, and a greater propensity to leave the firm, ultimately leading to negative financial consequences for the firm. These conditions result in internal service failure and create the need to recover employees-in other words, internal service recovery. However, little research has examined this issue so far. The purpose of the current study, therefore, is to investigate the relationship between internal service recovery and employee outcomes. A pre-test, post-test between-subjects experimental design was developed. Participants were 166 part-time students who were working full-time. The average age of the participants was 36.74 years, and 57.50% of them were female. The average length of employment was 13 years. Participants were randomly assigned to one of four groups of approximately equal size. Three of the groups were subjected to an experimental situation involving an internal service failure, while one group was not exposed to failure, thereby acting as a control group. This study contributes to the service marketing literature in several ways. First, the study extends service failure and/or recovery research by examining recovery in an employee context. Second, this study attempts to measure internal service recovery and to empirically demonstrate its relationship to employee outcomes. Third, this investigation emphasizes the managerial importance of internal service recovery. For example, understanding the nature of the relationships between internal service recovery and its consequences can improve the effectiveness and efficiency of managers' resource allocation decisions.

Analytical Model for Post Tension Flat Plate Frames (포스트 텐션 플랫 플레이트 골조의 해석모델)

  • Han, Sang-Whan;Ryu, Jong-Hyuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.6
    • /
    • pp.23-32
    • /
    • 2007
  • This study developed an analytical model for predicting nonlinear behavior of PT flat plate frames having slab-column connections with and without slab bottom reinforcement passing through the column. The developed model can predict the failure sequence until punching failure occurs. For verifying the analytical model, the test results of PT flat plate slab-column connections were compared with the results of the analysis. Moreover, the results of static pushover test and shaking table test of 2 story PT flat plate frame were compared with analysis results. For evaluating seismic performance of PT flat plate frame, this study conducted nonlinear response history analysis of the 2 story PT flat plate frame with and without slab bottom reinforcement passing through the column under 1940 El Centro ground motion scaled to have pseudo spectral acceleration of 0.3, 0.5, and 0.7g at the fundamental period of the frame. This study observed that as ground motion is more intense, seismic demands for the frame having the connections without slab bottom reinforcement passing through the column are larger than those without slab bottom reinforcement.

RESULTS OF THERMAL CREEP TEST ON HIGHLY IRRADIATED ZIRLO

  • Quecedo, M.;Lloret, M.;Conde, J.M.;Alejano, C.;Gago, J.A.;Fernandez, F.J.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.179-186
    • /
    • 2009
  • This paper presents a thermal creep test under internal pressure and post-test characterization performed on high burnup (68 MWd/kgU) ZIRLO. This research has been done by the CSN, ENRESA, and ENUSA in order to investigate the behavior of advanced cladding materials in contemporary PWRs at higher burnup under dry cask storage conditions. Also, to investigate the hydride reorientation, the cool-down of the samples after the test has been done in a coordinated manner with the internal pressure. The creep results obtained are consistent with the expected behavior from reference CWSR material, Zr-4. During the test, the material retained significant ductility: one specimen leaked during the test at an engineering strain of the tube section of 17%; remarkably, the crack closed due to de-pressurization. Although significant hydride reorientation occurred during the cool-down under pressure, no specimen failed during the cool-down.

Simulation study on CFRP strengthened reinforced concrete beam under four-point bending

  • Zhang, Dongliang;Wang, Qingyuan;Dong, Jiangfeng
    • Computers and Concrete
    • /
    • v.17 no.3
    • /
    • pp.407-421
    • /
    • 2016
  • This paper presents numerical modeling of the structural behavior of CFRP (carbon fiber reinforced polymer) strengthened RC (reinforced concrete) beams under four-point bending. Simulation of debonding at the CFRP-concrete interface was focused, as it is the main failure mode of CFRP strengthened RC beams. Here, cohesive layer was employed to model the onset of debonding, which further helps to describe the post debonding behavior of the CFRP strengthened RC beam. In addition, the XFEM approach was applied to investigate the effects of crack localization on strain field on CFRP sheet and rebar. The strains obtained from the XFEM correlate better to the test results than that from CDP (concrete damaged plasticity) model. However, there is a large discrepancy between the experimental and simulated loaddisplacement relationships, which is due to the simplification of concrete constitutive law.