• Title/Summary/Keyword: Post-closure

Search Result 147, Processing Time 0.03 seconds

Aortopulmonary Window (대동맥폐동맥창)

  • Kim Dong-Jin;Min Sun-Kyung;Kim Woong-Han;Lee Jeong-Sang;Kim Yong-Jin;Lee Jeong-Ryul
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.275-280
    • /
    • 2006
  • Background: Aortopulmonary window (APW) is a very rare congenital heart anomaly, often associated with other cardiac anomalies. It causes a significant systemic to pulmonary artery shunt, which requires early surgical correction. Accurate diagnosis and surgical correction will bring good outcomes. The purpose of this study was to describe our 20-year experience of aortopulmonary window. Material and Method: Between March 1985 and January 2005, 16 patients with APW underwent surgical repair. Mean age at operation was $157.8{\pm}245.3$ ($15.0{\sim}994.0$) days and mean weight was $4.8{\pm}2.5$ ($1.7{\sim}10.7$) kg. Patent ductus arteriosus (8), atrial septal defect (7), interruptedaortic arch (5), ventricular septal defect (4), patent foramen ovate (3), tricuspid valve regurgitation (3), mitral valve regurgitation (2), aortic valve regurgitation (1), coarctation of aorta (1), left superior vena cavae (1), and dextrocardia (1) were associated. Repair methods included 1) division of the APW with primary closure or patch closure of aorta and pulmonary artery primary closure or patch closure (11) and 2) intra-arterial patch closure (3). 3) Division of the window and descending aorta to APW anastomosis (2) in the patients with interrupted aortic arch or coarctation. Result: There was one death. The patient had 2.5 cm long severe tracheal stenosis from carina with tracheal bronchus supplying right upper lobe. The patient died at 5th post operative day due to massive tracheal bleeding. Patients with complex aortopulmonary window had longer intensive care unit and hospital stay and showed more morbidities and higher reoperation rates. 5 patients had reoperations due to left pulmonary artery stenosis (4), right pulmonary artery stenosis (2), and main pulmonary artery stenosis (1). The mean follow-up period was $6.8{\pm}5.6$ (57.0 days$\sim$16.7 years)years and all patients belonged to NYHA class 1. Conclusion: With early and prompt correction of APW, excellent surgical outcome can be expected. However, optimal surgical method needs to be established to decrease the rate of stenosis of pulmonary arteries.

Development and Animal Tests of Artificial Heart Valves (인공심장판막의 개발 및 동물실)

  • 이재영
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.458-472
    • /
    • 1987
  • A heart supplies bloods of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to this act of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of bloods. In an attempt to eliminate the affliction of heart valves, the operation method to repair with artificial heart valves has been developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. The artificial heart valve using pyrolytic carbon has been developed at KAIST, which was proved to be stable in the mechanical performance and durability. Therefore, the in viva performance of this valve was examined through animal tests. The artificial heart valves used in this study are tilting disc type valves, in which the disc were made of graphite coated with pyrolytic carbon and the cages were made of titanium. In viva testings of these valves were performed in 12 dogs, in which right ventriculo-pulmonary arterial [Croup I] or inter-aortic [Croup IV] valved conduit was implanted using polytetrafluoroethylene conduits containing KAIST valve and aortic valve [Group II] or pulmonary valve [Croup III] was replaced by a KAIST valve with a 21mm or 19mm tissue annulus diameter. In group I and II, pre-and post-operative transvalvular pressure gradient was measured and compared with other prosthetic valves. During post operative period laboratory examination was performed including hemoglobin, hematocrit, red cell count, white cell, lactic acid dehydrogenase and platelet. The eight surviving dogs were sacrificed and autopsy was performed at 2, 6, and 8 weeks. KAIST valve has low transvalvular gradient and relatively high orifice area. Average ventriculo-aortic peak systolic transvalvular gradient was 14 mmHg in 21 mm valve and 19 mmHg in 19 mm valve. The valve has slight intravascular hemolysis effect. Thrombogenic effect of low polishing quality and eddy currents around small orifice is high. The valve has vulnerability of disc movement. These animal tests suggest that the improvement of the heart valve design, surface polishing state and prescription methods.

  • PDF

A Comparison of the Analgesic and Side Effects of Epidural Morphine and Nalbuphine-Morphine Mixture in Post-Cesarean Section Patients (제왕 절개술후 통증 치료를 위해 경막외강에 투여된 Morphine 및 Nalbuphine-Morphine 혼합액의 비교 연구)

  • Lee, Youn-Woo;Lee, Ja-Won;Yoon, Duck-Mi;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.5 no.2
    • /
    • pp.221-228
    • /
    • 1992
  • The effect of epidural nalbuphine on pruritus, nausea, vomiting, voiding difficulties and/or analgesia induced by epidural morphine was determined in sixty Cesarian delivery patients. They were physical status 1 or 2 by ASA classification and randomly divided into three groups. They were administered morphine 3 mg only(group A), nalbuphine 5 mg with morphine 3 mg(group B), or nalbuphine 10 mg with morphine 3 mg(group C) at the time of peritoneal closure. During postoperative 24 hours their analgesic effects were evaluated by visual analogue scale(0~10). Respiratory rates, Trieger dot test and severity of side effects(0~2) were also evaluated. The results were as follows; 1) Analgesic duration of the first epidural administration was significantly long in group A than other groups, but there was no difference between that of group B and group C. 2) Pruritus was more severe in group A than other groups but the severity was decreased by increasing nalbuphine dosage. 3) Nausea and or vomiting was mild in group C and the incidence of nausea and/or vomiting combined with pruritus was decreased by increasing nalbuphine dosage. 4) Voiding difficulties was more severe in group A than other groups but the severity was not decreased by increasing nalbuphine dosage. 5) None of the patients had objective sedation or low respiration rate(< 10 times/minute). We concluded that epidural administration of nalbuphine 10 mg with morphine 3mg for post-Cesarean section pain management is one of good methods to reduce side effects induced by epidural morphine.

  • PDF

Numerical modeling and prediction of adhesion failure of adhesively bonded composite T-Joint structure

  • Panda, Subhransu K;Mishra, Pradeep K;Panda, Subrata K
    • Structural Engineering and Mechanics
    • /
    • v.74 no.6
    • /
    • pp.723-735
    • /
    • 2020
  • This study is reported the adhesion failure in adhesive bonded composite and specifically for the T-joint structure. Three-dimensional finite element analysis has been performed using a commercial tool and the necessary outcomes are obtained via an eight noded solid element (Solid 185-element) from the library of ANSYS. The structural analysis input has been incurred through ANSYS parametric design language (APDL) code. The normal and shear stress distributions along different layers of the joint structure have been evaluated as the final outcomes. Based on the stress distributions, failure location in the composite joint structure has been identified by using the Tsai-Wu stress failure criterion. It has been found that the failure index is maximum at the interface between flange and web part of the joint (top layer) which indicates the probable location of failure initiation. This kind of failures are considered as adhesion failure and the failure propagation is governed by strain energy release rate (SERR) of fracture mechanics. The different adhesion failure lengths are also considered at the failure location to calculate the SERR values i.e. mode I fracture (opening), mode II fracture (sliding) and mode III fracture (tearing) along the failure front. Also, virtual crack closure technique (VCCT) principle of fracture mechanics steps is used to calculate the above said SERRs. It is found that the mode I SERR is more dominating compared to other two modes of failure for the joint considered. Finally, the influences of various parametric (geometrical and material) effect on SERR of the joint structure are evaluated and discussed in details.

The superior lateral genicular artery flap for reconstruction of knee and proximal leg defects

  • Low, O-Wern;Loh, Tian Fu;Lee, Hanjing;Yap, Yan Lin;Lim, Jane;Lim, Thiam Chye;Nallathamby, Vigneswaran
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.108-114
    • /
    • 2022
  • Reconstruction of defects around the knee region requires thin and pliable skin. The superior lateral genicular artery (SLGA) flap provides an excellent alternative to muscle-based flaps. The anatomy and the surgical techniques of the SLGA flap were reviewed and the results of cases using the SLGA flap for coverage of knee and proximal leg defects were analyzed. SLGA flaps were performed in two cases and followed up for at least 6 months. Twelve articles on the use of the SLGA flap were also identified. A review of 39 cases showed that the mean diameter of the perforator supplying the skin of the flap was 1.04 mm, while the mean diameter of the SLGA at its origin was 1.78 mm. The mean length of the pedicle measured from the origin of the popliteal artery was 7.44 cm. The average dimensions of the flap were 14.8×6.6 cm with primary closure of the donor site in 61.5% of cases. Of these cases, 38.5% were due to trauma, 23.1% were post-burn complications, 12.8% were defects after resection of tumors, and 10.3% were for ulcers post-bursectomy. The most common complication was flap tip necrosis. All studies reported favorable outcomes with complete wound healing.

A Study on Postmodernism Style of Fashion - Concentrating on the 1996-2000- (현대 복식에 나타난 포스트모더니즘 양식 연구 -90년대 후반 복식을 중심으로-)

  • Kim Hee-Kyun;Chung Hei-Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.3_4 s.141
    • /
    • pp.569-575
    • /
    • 2005
  • The objective of this study is to consider the concept of postmodernism and the characteristics concerning the stage of the development, and to investigate the effect of the postmodernism on the clothing. Postmodernism is the result of the late capitalism and its characteristics are the narrative, mixture and deconstruction. First, since it is impossible to express the social culture of various society through one theoretical disclosure, the novel value on the narrative is provided and its characteristics arise. Hence, the society becomes afford to accept the other and provides the novel value to the absolute sub-concept. Second, the recognization and emphasis of the narrative in the post modem society bring about the repulsion as to the strict classification between the high culture and low one established from modernism and the closure between each genre of the art, and this causes to raise the composed characteristics which borrow or mix the style and image of different age and culture. Third, the deconstructive feature arises which eliminates the boundary between the high and low class, the past and future and the destruction and construction. This means not only anther recomposition but also skeptical attitude about it.

Early Healing Responses of the Skin Wounds in the Korean Fire-Bellied Toad, Bombina orientalis (무당개구리 (Bombina orientalis) 피부의 초기 상처치유반응)

  • Jeong, Moon-Jin;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.329-343
    • /
    • 1998
  • Early wound healing responses in the skin of the Korean fire bellied toad, Bombina orientalis, were examined using histochemical , scanning and transmission electron microscopical techniques. Cutaneous wounds were induced by sharp razor blade , and maintained in special cages for up to 3 days. By this treatment whole parts of epithelium and dermis were profoundly affected. After injury, retraction of damaged surface of the skin was observed. At 3 hours after injury, poly-band was form by mucous substance. The wound skin consisted of mucous gland secreted mucous substance which flows into wound cavity and the wound area was sealed by mucous substance which form thick layer at 6 hours. It appeared that natural disposition showed acid and neutral mucous substance by reaction of PAS and Alcian blue (pH 2.5) staining. After formation of the poly-band, epithelial cells were formed by migration of regenerating epithelial cells. These cells moved over the wound surface by migration at 12 hours after wounding. Poly-band was much increased in thickness and migrating cells were completely formed wound closure at 24 hours post-wounding. After 72 hours regenerated epithelial layer consists of four or five cell layers which are similar to clear, granular, and spinous layer.

  • PDF

Unexpected Severe Cerebral Edema after Cranioplasty : Case Report and Literature Review

  • Lee, Gwang Soo;Park, Sukh Que;Kim, Rasun;Cho, Sung Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.76-78
    • /
    • 2015
  • This report details a case of unexpected, severe post-operative cerebral edema following cranioplasty. We discuss the possible pathological mechanisms of this complication. A 50-year-old female was admitted to our department with sudden onset of stuporous consciousness. A brain computed tomography (CT) revealed a subarachnoid hemorrhage with intracranial hemorrhage and subdural hematoma. Emergency decompressive craniectomy and aneurysmal neck clipping were performed. Following recovery, the decision was made to proceed with an autologous cranioplasty. The cranioplasty procedure was free of complications. An epidural drain was placed and connected to a suction system during skin closure to avoid epidural blood accumulation. However, following the procedure, the patient had a seizure in the recovery room. An emergency brain CT scan revealed widespread cerebral edema, and the catheter drain was clamped. The increased intracranial pressure and cerebral edema were controlled with osmotic diuretics, corticosteroids, and antiepileptic drugs. The edema slowly subsided, but new low-density areas were noted in the brain on follow-up CT 1 week later. We speculated that placing the epidural drain on active suction may have caused an acute decrease in intracranial pressure and subsequent rapid expansion of the brain, which impaired autoregulation and led to reperfusion injury.

Abducens Nerve Palsy after Lumbar Spinal Fusion Surgery with Inadvertent Dural Tearing

  • Cho, Dae-Chul;Jung, Eul-Soo;Chi, Yong-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.581-583
    • /
    • 2009
  • Abducens nerve palsy associated with spinal surgery is extremely rare. We report an extremely rare case of abducens nerve palsy after lumbar spinal fusion surgery with inadvertent dural tearing, which resolved spontaneously and completely. A 61-year-old previous healthy man presented with chronic lower back pain of 6 weeks duration and 2 weeks history of bilateral leg pain. He was diagnosed as having isthmic spondylolisthesis at L4-5 and L5-S1, and posterior lumbar interbody fusion was conducted on L4-5 and L5-S1. During the operation, inadvertent dural tearing occurred, which was repaired with a watertight dural closure. The patient recovered uneventfully from general anesthesia and his visual analogue pain scores decreased from 9 pre-op to 3 immediately after his operation. However, on day 2 he developed headache and nausea, which were severe when he was upright, but alleviated when supine. This led us to consider the possibility of cerebrospinal fluid leakage, and thus, he was restricted to bed. After an interval of bed rest, the severe headache disappeared, but four days after surgery he experienced diplopia during right gaze, which was caused by right-side palsy of the abducens nerve. Under conservative treatment, the diplopia gradually disappeared and was completely resolved at 5 weeks post-op.

A successful Mustard operation for complete transposition of the great arteries combined with VSD, ASD, dextrocardia and PS: a report of one case (심실중격결손, 심방중격결손, 폐동맥협착과 우심증을 동반한 완전대혈관전위증의 치험)

  • 조중구
    • Journal of Chest Surgery
    • /
    • v.15 no.3
    • /
    • pp.346-354
    • /
    • 1982
  • A Complete transposition of the great arteries combined with V.S.D, A.S.D, dextrocardia, and P.S is a rare congenital anomaly. The patient was a 10 year-old female whose complaints were frequent URI, exertional dyspnea, and cyanosis at rest since birth. Cheat X-ray films showed Dextrocardia ; situs inversus, moderate cardiomegaly, and Characteristic egg-shape heart shadow. E.K.G, Echocardiography, Cardiac Catheterization, and Angio-Cardiography were performed. Open heart Surgery was done under diagnosis of d-TGA, Dextrocardia, V.S.D, A.S.D, and P.S. At the time of Operation, Dextroeardia, T.G.A, Secndum type A.S.D, A.S.D, and P.S. At the time of Operation, Dextroeardia, T.G.A, Secndum type A.S.D. ($2.0{\times}2.0cm$. in diameter), V.S.D. type II ($1.5cm{\times}1.5cm$ in diameter), and pulmonary valvular stenosis were noted. Mustard operation using pericardial Baffle in the atrium for T.G.A. was perforsned. Teflon patch graft for closure of V.S.D. through tricuspid orifice and pulmonary Valvulotomy through pulmonary arteriotomy were performed. The post-op, low cardiac output Syndrome and dysrhythmicawere developed till Postoperative day #7, so that was controlled by inotropic and antiarrhythmic agents. After that, patient's conditions were Uneventful.

  • PDF