• 제목/요약/키워드: Post curing

검색결과 140건 처리시간 0.024초

후경화기와 경화시간에 따른 3D 프린팅 레진의 굴곡강도 평가 (Evaluation of Flexural Strength of 3D Printing Resin According to Post-Curing Equipment and Time)

  • 김해봄;최재원
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.629-637
    • /
    • 2023
  • This study aimed to evaluate the effect of post-curing equipment and time on the flexural strength of 3D printing resins produced by a liquid crystal display(LCD) printer. The three 3D printing resins(DENTCA Denture Teeth, DT; C&B 5.0 hybrid, CH; C&B Permanent A2, CP) were divided into four groups according to post-curing time(10 min and 30 min) and equipment with or without vacuum treatment. For the three-point flexural strength test and biaxial strength test were prepared by method according to ISO 10477, ISO 6872, respectively. Flexural strength was measured with universal testing machine. Comparison between post-curing time of each post-curing equipment was analyzed by independent sample t-test and Mann-Whitney U test(α=.05), and comparison between groups according to each 3D printing resin was performed by Kruskal-Wallis test and post-hoc by Bonferroni-Dunn test(α=.05). The flexural strength of the resin post-curing under vacuum was higher than that of the resin post-curing in air. In the comparison according to the post-curing time, in the case of the post-curing equipment without vacuum, the 30 minute curing time showed significantly higher flexural strength than the 10 minute curing time, except for the biaxial flexural strength of CH(P<.05). In the post-curing equipment with vacuum, the three-point flexural strength of all 3D printing resins(DT, CH, and CP) showed a higher value at 30 minute curing time than at 10 minute curing time.

Pre-and Post-Curing of Readout Layer of Super Resolution Disc

  • Kim, Sun-Hee;Kwak, Keum-Cheol;Lee, Chang-Ho;Song, Ki-Chang
    • 정보저장시스템학회논문집
    • /
    • 제3권3호
    • /
    • pp.113-117
    • /
    • 2007
  • 재생층이 상변화물질로 이루어진 초해상 광디스크에 있어서, 기록 전과 후에 thermal curing 을 실시하여 신호품질과 재생안정성이 크게 향상되었다. Pre-curing으로 수천 회 이하에서 나타나는 short-term stability가 향상되었고, post-curing 한 후 mid-term stability 가 향상되었다. 그리고, pre- and post-curing 후 noise level 은 전반적으로 $1{\sim}2dB$가 낮아졌고, CNR은 $2{\sim}3dB$, jitter 는 $2{\sim}3%$ 가 향상되었다.

  • PDF

Recovery of mortar-aggregate interface of fire-damaged concrete after post-fire curing

  • Li, Lang;Zhang, Hong;Dong, Jiangfeng;Zhang, Hongen;Jia, Pu;Wang, Qingyuan;Liu, Yongjie
    • Computers and Concrete
    • /
    • 제24권3호
    • /
    • pp.249-258
    • /
    • 2019
  • In order to investigate the strength recovery of fire-damaged concrete after post-fire curing, concrete specimens were heating at $2^{\circ}C/min$ or $5^{\circ}C/min$ to 400, 600 and $800^{\circ}C$, and these exposed specimens were soaked in the water for 24 hours and following by 29-day post-fire curing. The compressive strength and split tensile strength of the high-temperature-exposed specimens before and after post-fire curing were tested. The proportion of split aggregate in the split surfaces was analyzed to evaluate the mortar-aggregate interfacial strength. After the post-fire curing process, the split tensile strength of specimens exposed to all temperatures was recovered significantly, while the recovery of compressive strength was only obvious within the specimens exposed to $600^{\circ}C$. The tensile strength is more sensitive to the mortar-aggregate interfacial cracks, which caused that the split tensile strength decreased more after high-temperature exposure and recovery more after post-fire curing than the compressive strength. The mortar-aggregate interfacial strength also showed remarkable recovery after post-fire curing, and it contributed to the recovery of split tensile strength.

DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석 (Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제43권2호
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kim, Dong-Yeon;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.89-99
    • /
    • 2021
  • PURPOSE. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to post-curing time. MATERIALS AND METHODS. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute post-curing interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P<.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. CONCLUSION. Interim crowns with 10-minute post-curing showed high accuracy.

Comparing volumetric and biological aspects of 3D-printed interim restorations under various post-curing modes

  • Song, Gun;Son, Ji-Won;Jang, Ji-Hyun;Choi, Sung-Hyeon;Jang, Woo-Hyung;Lee, Bin-Na;Park, Chan
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey's post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion. The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, post-curing did not significantly influence the DOC and cytotoxicity of the restorations.

알루미늄 함량에 따른 추진제 노화 특성 (Propellant Aging Characteristics According to Aluminum Contents)

  • 정재윤;박정호
    • 한국추진공학회지
    • /
    • 제24권4호
    • /
    • pp.66-72
    • /
    • 2020
  • 본 논문은 알루미늄 함량 변화에 따른 추진제의 후경화에 대한 영향성, 화학적 노화도에 관하여 기술하였다. 동일 경화조건에서 알루미늄 함량이 18 wt%인 추진제가 2 wt%인 추진제 대비 후경화 기간이 길어지는 것으로 확인하였다. 반면 후경화가 포함된 화학적 노화도 분석에서는 알루미늄 함량이 18 wt%인 추진제가 2 wt%인 추진제 대비 화학적 노화가 천천히 진행되는 것을 확인하였다.

후경화에 따른 3차원 프린팅 의치의 체적변화 (Evaluation of the dimensional change of 3D-printed complete denture after post-curing)

  • 이수연;곽영훈;박은철;김희중
    • 구강회복응용과학지
    • /
    • 제38권4호
    • /
    • pp.233-241
    • /
    • 2022
  • 목적: 이 연구목적은 3차원 프린팅의치의 후경화후로 인한 의치의 체적변화를 평가하고자하였다. 연구 재료 및 방법: 상·하악 의치를 Exocad DentalCaD 프로그램을 이용하여 디자인하였으며, STL 파일로 추출하였다. DLP 방식의 치과용 3차원 플린터를 이용하여 상·하악 의치 STL파일을 상·하악 각기 10개씩 출력하였다. 출력된 상·하악 의치는 세척하였고, 후경화를 시행하기전과 후에 각 각 모형스캐너를 이용하여 스캔파일을 만들었다. 후경화 전후의 스캔된 의치파일을 중첩하여 변화를 평가하였으며, 의치상의 계측점사이의 거리를 측정하였다. 통계는 SPSS를 이용하였으며, 유의수준은 5%였다. 결과: 상악의치는 후경화 후에 전반적으로 수축하였으며, 후구개부위에서 가장 뚜렷한 변화를 보였다. 상악의치 전후방 (A-D, A-E, A-F)의 길이와 양측제1대구치사이(B-C)의 길이 감소가 통계학적으로 유의성을 보였다. 하악의치는 후경화 후에 전후방의 길이변화보다는 폭경의 변화가 비교적 뚜렷하였는데, 의치후방(A-M, A-D, A-E, A-L, A-H, A-I, H-I)과 설측(J-K, L-M)에서 통계학적으로 유의성있는 길이변화가 관찰되었다. 결론: 이 실험의 결과내에서, 3차원 프린터로 출력되는 상·하악 의치는 후경화 후에 길이와 폭이 모두 변화하였다. 결론적으로, 의치의 변형을 최소화할 수 있는 후경화 방법과 재료의 개발이 필요할 것으로 사료된다.

광중합형 프린터로 제작한 인공치아, 의치상, 모노블럭 총의치의 후경화에 따른 3차원 정확성 평가 (Three-dimensional accuracy evaluation of post-curing of artificial teeth, denture bases, and denture base monoblocks manufactured by digital light processing)

  • 김동연;양천승;이광영
    • 대한치과기공학회지
    • /
    • 제46권3호
    • /
    • pp.84-92
    • /
    • 2024
  • Purpose: To evaluate the effect of post-curing on the three-dimensional (3D) accuracy of artificial teeth, denture bases, and denture base monoblock manufactured using digital light processing (DLP) technology. Methods: Using an edentulous model, a 3D design was made for complete dentures. Three groups were printed by DLP: artificial teeth, denture bases, and denture base monoblock. The models were scanned, subjected to post-curing, and scanned again. Three-dimensional analysis was performed based on the post-treatment differences among the three groups. Statistical analysis was performed using SPSS Statistics ver. 22.0 (IBM), and the Mann-Whitney U-test and Kruskal-Wallis test were employed as nonparametric tests. Results: The complete denture monoblock (CM) and complete denture artificial teeth (CA) groups showed the lowest and highest errors at 15.13 and 23.37 ㎛, respectively. The groups did not show significant differences (p>0.05). In the significance test among the three groups, no significance was found in the CA group; however, significant differences were found between the complete denture base (CB) and CM groups. In addition, the three groups showed significant differences (p<0.05). Conclusion: Although deformation may occur during the post-curing process, it is within the clinically acceptable range. Future comparative studies using different 3D printers and searching for ways to minimize errors through optimization of the post-curing process are warranted.

화재 후 재양생 조건에 따른 콘크리트의 강도복원특성 (Strength recovery of fire-damaged concrete after post-fire-curing)

  • 이중원;최광호;홍갑표
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.170-173
    • /
    • 2006
  • The purpose of this study is to investigate the effect of post-fire-curing on the strength recovery of fire-damaged concrete The 170 specimens have been tested with variables of concrete strengths(20, 30, 40, 50, 60Mpa) exposed to elevated temperatures till $600^{\circ}C$ and $800^{\circ}C$. After natural cooling, the specimens were subjected to post-fire-curing in water and in a controlled chamber for a total duration of 56days. Unstressed compressive strength was conducted to examine the change in the concrete. The test results indicated that the post-fire-curing results in substantial strength recovery and its extent depend on the method and duration of recuring.

  • PDF