• Title/Summary/Keyword: Post Chamber

Search Result 136, Processing Time 0.025 seconds

Fasting Heat Production of Growing Buffalo Calves

  • Tiwari, C.M.;Chandramoni, Chandramoni;Jadhao, S.B.;Khan, M.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.3
    • /
    • pp.307-312
    • /
    • 2000
  • Fasting heat production (FHP) of growing buffalo calves (Bubalus bubalis) in the body weight range of 76 to 236 kg was determined using open circuit respiration chamber. The details of the chambers, calibration of gas analysers and operation of the systems are described. Animals were fasted for 96 hrs during which only water was provided. FHP was determined during next 24 hrs. The mean oxygen consumed, carbon dioxide and methane produced and urinary N excretion per 24 h was $17.03{\ell}$, $11.70{\ell}$, and $0.12{\ell}$ and 0.35 g respectively. The mean respiratory quotient ranged from 0.68 to 0.71, which indicated that post absorptive stage is reached after 96 hrs in growing buffalo calves previously fed ammoniated straw-based ration. Mean FHP of calves was $331.4kJ/kg\;W^{0.75}$. FHP of calves with range of mean body weights of 167 to 235 kg, although nonsignificant but, was almost 12% higher than of calves having mean body weight of 101 kg. Suitable exponent to body weight to describe FHP of buffalo calves was 0.87.

HRTF Measurement and Its Application for 3-D Soung Localization

  • Kang, Kyeong Ok;Kang, Dong-Gyu;Hahn, Minsoo;Jho, Moon Jae;Jeong, Dae-Gwon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3E
    • /
    • pp.50-55
    • /
    • 1997
  • Based on the anthropometric data of Korea male adults, a head and torso simulator(HATS) is constructed to measure its head related transfer functions (HRTFs) which can be used for three dimensional (3-D) sound localization. The HRTFs binaural impulse responses, are measured in an anechoic chamber using a burst maximum length sequence (MLS) signal of 65,535 samples and 32,768 samples acquisition at the sampling rate of 75.47kHz. Also measured are the impulse responses of a driving loudspeaker and some headphones for sound reproduction to get the exact HRTF of the HATS-alone. Through a post-processing procedure, the impulse-version HRTFs at the sampling frequency of 44.1 kHz, which have filter lengths of 512 points, are finally obtained. As an application of the measured HRTFs, a 3-D sound processor for headphone reproduction has been developed. The signal intervals to be processed can be selected and each interval is manipulated to have its diretionality and distance information by using corresponding HRTF and energy control.

  • PDF

Construction of the Pressure Sensitive Paint System (PSP 압력측정 시스템의 구축)

  • Jeon, Young-Jin;Kim, Ki-Su;Seo, Hyung-Seok;Byun, Yung-Hwan;Lee, Jae-Woo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.7-15
    • /
    • 2008
  • Pressure Sensitive Paint(PSP) means a reacting paint in pressure. The calibration of PSP and the wind tunnel test of PSP painted model are required to measure pressure by using PSP. Therefore, the post processing from these results shows the information and image of the pressure distribution. PSP can show the information of total pressure from the wind tunnel test and the calibration. In this study, equipments of PSP are composed, and experiment is accomplished by using PSP. The surface pressure distribution around the wall of nozzle is measured by PSP. The measured pressure has similar results to those of the CFD and pressure tap measurement.

Fabrication and Properties of MFSFET′s Using $BaMgF_4$/Si Structures for Non-volatile Memory ($BaMgF_4$/Si 구조를 이용한 비휘발성 메모리용 MFSFET의 제작 및 특성)

  • 이상우;김광호
    • Electrical & Electronic Materials
    • /
    • v.10 no.10
    • /
    • pp.1029-1033
    • /
    • 1997
  • A prototype MFSFET using ferroelectric fluoride BaMgF$_4$as a gate insulator has been successfully fabricated with the help of 2 sheets of metal mask. The fluoride film was deposited in an ultrai-high vacuum system at a substrate temperature of below 30$0^{\circ}C$ and an in-situ post-deposition annealing was conducted for 20 seconds at $650^{\circ}C$ in the same chamber. The interface state density of the BaMgF$_4$/Si(100) interface calculated by a MFS capacitor fabricated on the same wafer was about 8$\times$10$^{10}$ /cm$^2$.eV. The I$_{D}$-V$_{G}$ characteristics of the MFSFET show a hysteresis loop due to the ferroelectric nature of the BaMgF$_4$film. It is also demonstrated that the I$_{D}$ can be controlled by the “write” plus which was applied before the measurements even at the same “read”gate voltage.ltage.

  • PDF

Low Temperature Deposition of ITO Thin Films for Flat Panel Displays by ICP Assisted DC Magnetron Sputtering (유도결합 플라즈마(ICP) Sputtering에 의한 평판 디스플레이(FPD)용 ITO 박막의 저온 증착)

  • 구범모;정승재;한영훈;이정중;주정훈
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.3
    • /
    • pp.146-151
    • /
    • 2004
  • Indium tin oxide (ITO) is widely used to make a transparent conducting film for various display devices and opto-electric devices. In this study, ITO films on glass substrate were fabricated by inductively coupled plasma (ICP) assisted dc magnetron sputtering. A two-turn rf coil was inserted in the process chamber between the substrate and magnetron for the generation of ICP. The substrates were not heated intentionally. Subsequent post-annealing treatment for as-deposited ITO films was not performed. Low-temperature deposition technique is required for ITO films to be used with heat sensitive plastic substrates, such as the polycarbonate and acrylic substrates used in LCD devices. The surface roughness of the ITO films is also an important feature in the application of OLEDs along with the use of a low temperature deposition technique. In order to obtain optimum ITO thin film properties at low temperature, the depositions were carried out at different condition in changing of Ar and $O_2$ gas mixtures, ICP power. The electrical, optical and structural properties of the deposited films were characterized by four-point probe, UV/VIS spectrophotometer, atomic force microscopy(AFM) and x-ray diffraction (XRD). The electrical resistivity of the films was -l0$^{-4}$ $\Omega$cm and the optical transmittance in the visible range was >85%. The surface roughness ( $R_{rms}$) was -20$\AA$.>.

Preparation and Characterization of Blue Thin Film Phosphors by Pulsed Laser Deposition (PLD(Pulsed Laser Deposition)를 이용한 청색 박막 형광체의 제조 및 특성분석)

  • Cho, Sang-Ho;Jung, Yu-Sun;Kwak, Jung-Ho;Sohn, Kee-Sun
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.12 s.295
    • /
    • pp.852-858
    • /
    • 2006
  • It is well known that $BaMgAl_{10}O_{17}:Eu^{2+}$ (BAM) and $CaMgSi_2O_6:Eu^{2+}$ (CMS) are a highly efficient blue phosphor. However, these phosphors in the form of thin films have not yet been realized clue to technical difficulties. We prepared thin film type BAM and CMS phosphors on quartz glass substrate using a pulsed laser deposition technique. The luminescent and structural properties of thin film phosphors were monitored as a function of key processing parameters such as oxygen partial pressure inside the deposition chamber, deposition time, laser energy density and the type of post-deposition treatments used. Even though we could not obtain single homogenous phases, thin films with large homogenous areas and a high photoluminescence could be produced by optimizing these processing parameters.

Hot-firing Test Results of Subscale Gas Generator for 75 ton-class Liquid Rocket Engine (75톤급 액체로켓엔진 축소형 가스발생기 연소시험 결과)

  • Kim, Mun-Ki;Ahn, Kyu-Bok;Lim, Byoung-Jik;Kim, Jong-Gyu;Seo, Seong-Hyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.726-728
    • /
    • 2010
  • A subscale gas generator was designed and manufactured to investigate the effect of design parameters on discharge coefficients of injectors for a 75 ton-class gas generator and hot-firing tests were successfully performed. The test results showed that discharge coefficients of fuel and liquid oxygen injectors remained nearly constant irrespective of variations of a mixture ratio and a chamber pressure. When the post diameter of the liquid oxygen injector was reduced, the discharge coefficient was increased as the pressure drop of the injector was decreased.

  • PDF

IoT Basic Study on Development of Duct Burner Integrated with SCR Catalyst (SCR 촉매 일체형 덕트 버너 개발에 대한 IoT 기초연구)

  • Jang, Sung-Cheol;Shim, Yo-Seop
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.75-80
    • /
    • 2021
  • Since the optimization of the diesel engine for the ship cannot satisfy the NOx emission limit by the method of reducing the NOx emission, it is necessary to reduce the NOx by post-processing the exhaust gas. In this study, we will review the feasibility of designing a binary nozzle and mixing chamber duct for effectively converting the number of elements into NH3 in the oil burner for the SCR catalyst unit integrated duct in the ship under development through the computational heat flow analysis for the velocity distribution and temperature distribution.

Distal Aortic Remodeling after Type A Dissection Repair: An Ongoing Mirage

  • Rathore, Kaushalendra Singh
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.439-448
    • /
    • 2021
  • Remodeling is a commonly encountered term in the field of cardiothoracic surgery that is often used to describe various pathophysiological changes in the dimension, structure, and function of various cardiac chambers, including the aorta. Stanford type A or DeBakey type 1 aortic dissection (TAAD) is a perplexing pathologic condition that can present surgical teams with the need to navigate a maze of complex decision-making. Ascending or hemi-arch replacement leaves behind a significant amount of distal diseased aortic tissue, which might have a persistent false lumen or primary or secondary intimal tears (or communications between lumina), which can lead to dilatation of the aortic arch. Unfavorable aortic remodeling is a major cause of distal aortic deterioration after the index surgery. Cardiac surgeons are aware of post-surgical cardiac chamber remodeling, but the concept of distal aortic remodeling is still idealized. The contemporary literature from established aortic centers supports aggressive management of the residual aortic pathology during the index surgery, and with continuing technical advancements, endovascular stenting options are readily available for patients with TAAD or for complicated type B aortic dissection cases. This review discusses the pathophysiology and treatment options for favorable distal aortic remodeling, as well as its impact on mid- to long-term outcomes following TAAD repair.

Optimization of Flow Uniformity in an Electrostatic Precipitator (ESP) Duct (전기집진기 (ESP) 덕트 내부 유동 균일화를 위한 연구)

  • Junhyung, Hong;Minseung, Hwang;Joungho, Han;Woongchul, Choi;Jeongmo, Seong;Wontae, Hwang
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.86-93
    • /
    • 2022
  • An electrostatic precipitator (ESP) is an industrial post processing facility for high efficiency dust mitigation. Uniformity of the flow passing through the inlet duct leading into the main chamber is important for efficient reduction of dust. To examine flow uniformity, this study conducted a numerical analysis of the flow within a scale-down ESP inlet duct. Magnetic resonance velocimetry (MRV) results from a prior study were utilized to validate the Reynolds-averaged Navier-Stokes (RANS) numerical simulations. Both the experimental and computational results displayed a similar recirculation zone shape and normalized velocity profile near the duct outlet for the baseline geometry. To optimize the uniformity of the flow, the number of guide vanes was modified, and the guide vanes were partially extended straight upward. Design evaluation is done based on the outlet velocity distribution and mass flowrate balance between the two outlets. Simulation results indicate that the vane extension is critical for flow optimization in curved ESP ducts.