• Title/Summary/Keyword: Possibility Measure

검색결과 723건 처리시간 0.025초

제천지역 전압변동에 따른 전자계에 대한 퍼지척도 가능성 평가 (Assessment of Fuzzy Measure Possibility for the Electromagnetic Field according to Voltage fluctuation of the Jechon Area)

  • 김상철
    • 한국안전학회지
    • /
    • 제20권2호
    • /
    • pp.50-55
    • /
    • 2005
  • This Paper Presents assessment of fuzzy measure Possibility far the electromagnetic field according to voltage fluctuation of the Jechon Area. To cope with substantial electromagnetic analysis, the safety assessment were analyzed the double 154kV T/L, 345kV T/L, Jechon-Ichon Jechon-Youngju, respectively. As the results of case study, in case of 345kV T/L, the electric field value was 11.4927kV/m, magnetic field value was 0.4622G at the Point about 7m away from the line in severest case. Tn assessment of fuzzy measure Possibility for the electromagnetic field, this paper use probability of fuzzy and measure of fuzziness technique.

부하의 전압특성을 고려한 3상 2회선 불평형 송전선로에서의 전자계에 대한 퍼지척도 가능성평가 (Assessment of Fuzzy Measure Possibility for the Electromagnetic Field of unbalanced two coupled Three-phase Transmission line Considering toad-Voltage Characteristics)

  • 송현선;김상철
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.45-52
    • /
    • 2001
  • This paper presents a study on the assessment of fuzzy measure possibility for the electromagnetic field of unbalanced system. It takes into account m untransposed transmission line and unbalanced load. A three phase load flow program was developed which employs a Newton-Raphson method as a tool to analyze system unbalanced. This research presents a method of handling two coupled three phase transmission system unbalance analysis and unbalanced power demand as a function of voltages. In assessment of fuzzy measure possibility for the electromagnetic field, this paper use probability of fuzzy and measure of fuzziness technique.

  • PDF

퍼지이론을 이용한 3상 2회선 불평형 송전선로에서의 전자계에 대한 인체 위험 가능성평가 (Assessment of Possibility on the Human Risk for the Electromagnetic Field of Unbalanced Two Coupled Three-phase Transmission Line Using Fuzzy Theory)

  • 김상철;김두현
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.22-28
    • /
    • 2006
  • This paper presents assessment of possibility on the human risk for the electromagnetic field of unbalanced two coupled three-phase transmission line using fuzzy theory. Three phase load flow program was developed which employed a Newton-Raphson method as a tool to analyze system unbalanced. This research presents a method of handling two coupled three phase transmission system unbalance analysis and unbalanced power demand as a function of voltages. As the results of case study, in case of 345[kV] T/L, the electric field intensity was 10.9540[kV/m], magnetic field intensity was 0.2567[G] in severest case. The results showed that the membership of a proposition fuzzy '10.9540 [kV/m] is hazardous' is 0.6349. As the analytic results using the fuzzy qualifier term, the membership in case of very false is 0.1379 and fairly false is 0.6124, respectively. In assessment of fuzzy measure possibility for the electromagnetic field, this paper used probability of fuzzy arid measure of fuzziness technique.

가능성 이론을 이용한 전력계통 고장진단 (Power System Fault Diagnosis using Possibility Theory)

  • 이흥재;이철균;박등용;김성희;안복신
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.665-670
    • /
    • 1999
  • This paper introduces a fuzzy expert systems for fault diagnosis, where the causal relationships between faults and protective devices are defined as fuzzy relations. The uncertainties existing in the fault diagnosis are figured out using the possibility theory and the possibility measure is associated with the fuzzy relation to evaluate the possibilities of faults. Besides, the knowledge base in the expert system is described and explained. In this way, multiple-fault can be handled easily and simultaneously together with single faults.

  • PDF

Uncertainty in the dempster-shafer Theory - A Critical Re-examination

  • Klir, George J.;Ramer, Arthur
    • 한국지능시스템학회논문지
    • /
    • 제1권2호
    • /
    • pp.4-45
    • /
    • 1991
  • Measures of two types of uncertainty that coexist in the Dempster-Shafer theory are overivewed. A measure of one type of uncertainty, which expresses nonspecificity of evidential claims, is well justified on both intuitive and mathermatical grounds. Proposed measures of the other types of uncertainty, which attempt to capture conflicts among evidential claims, are shown to have some deficiencies. To alleviate these deficiencies, a new measure is proposed. This measure, which is called a measure of discord, is not only satisfactory on intuitive grounds, but has alos desirable mathematical properties. A measure of total uncertainty, which is defined as the sum of nonspecificity and discord, is also discussed. The paper focuses on conceptual issues. Mathematical properties of the measure of idscord are only stated ; their proofs are given in a companion paper.

  • PDF

On the Possibility of Multiple ICP and Helicon Plasma for Large-area Processes

  • Lee, J.W.;An, Sang-Hyuk;Chang, Hong-Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.234.1-234.1
    • /
    • 2014
  • Many studies have been investigated on high density plasma source (Electron Cyclotron Resonance[ECR], Inductively Coupled Plasma[ICP], Helicon plasma) for large area source after It is announced that productivity of plasma process depends on plasma density. Among them, Some researchers have been studied on multiple sources In this study, we attempted to determine the possibility of multiple inductively coupled plasma (ICP), and helicon plasma sources for large-area processes. Experiments were performed with the one and two coils to measure plasma and electrical parameters, and a circuit simulation was performed to measure the current at each coil in the 2-coil experiment. Based on the result, we could determine the possibility of multiple ICP sources due to a direct change of impedance due to current and saturation of impedance due to the skin-depth effect. However, a helicon plasma source is difficult to adapt to the multiple sources due to the consistent change of real impedance due to mode transition and the low uniformity of the B-field confinement. As a result, it is expected that ICP can be adapted to multiple source for large-area processes.

  • PDF

생성집합을 이용한 다 기간 성과평가를 위한 DEA 모델 개발 및 공학교육혁신사업 사례적용 (Multi-period DEA Models Using Spanning Set and A Case Example)

  • 김기성;이태한
    • 산업경영시스템학회지
    • /
    • 제45권3호
    • /
    • pp.57-65
    • /
    • 2022
  • DEA(data envelopment analysis) is a technique for evaluation of relative efficiency of decision making units (DMUs) that have multiple input and output. A DEA model measures the efficiency of a DMU by the relative position of the DMU's input and output in the production possibility set defined by the input and output of the DMUs being compared. In this paper, we proposed several DEA models measuring the multi-period efficiency of a DMU. First, we defined the input and output data that make a production possibility set as the spanning set. We proposed several spanning sets containing input and output of entire periods for measuring the multi-period efficiency of a DMU. We defined the production possibility sets with the proposed spanning sets and gave DEA models under the production possibility sets. Some models measure the efficiency score of each period of a DMU and others measure the integrated efficiency score of the DMU over the entire period. For the test, we applied the models to the sample data set from a long term university student training project. The results show that the suggested models may have the better discrimination power than CCR based results while the ranking of DMUs is not different.

퍼지가능성 척도를 이용한 전기화재 원인진단 시스템의 구축 (Construction of Diagnosis System for Electric-fire Causes using Fuzzy Possibility Measure)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제7권4호
    • /
    • pp.105-114
    • /
    • 1992
  • This paper presents an study on the knowledge based system for diagnosing the fire causes using the Fuzzy Possibility Measure( FPM ) about the electric-fire ignition. The Ignition values needed for causes diagnosis is computed as FPM for electric-fire ignition based on the internal scale technique that assigns numerically the characteristic difference of facts to the-tin-ear scale. For the convinience of inference, ignition sources are classified into seven types : short, ground fault, leakge of electricity, overcurrent, cord junction overheating, bad Insulation and spark. The system for causes diagnosis of electric-fire is composed of Knowledge Acquisition System, Inference Engine and Man-Machine Interface, The diagnosis system is wrritten in an artificial intelligence langusge “PROLOG” which uses depth-first search and backward chaining schemes in reasoning process.

  • PDF

FUZZY RISK MEASURES AND ITS APPLICATION TO PORTFOLIO OPTIMIZATION

  • Ma, Xiaoxian;Zhao, Qingzhen;Liu, Fangai
    • Journal of applied mathematics & informatics
    • /
    • 제27권3_4호
    • /
    • pp.843-856
    • /
    • 2009
  • In possibility framework, we propose two risk measures named Fuzzy Value-at-Risk and Fuzzy Conditional Value-at-Risk, based on Credibility measure. Two portfolio optimization models for fuzzy portfolio selection problems are formulated. Then a chaos genetic algorithm based on fuzzy simulation is designed, and finally computational results show that the two risk measures can play a role in possibility space similar to Value-at-Risk and Conditional Value-at-Risk in probability space.

  • PDF

부력 추를 이용한 지하수위 측정용 센서 개발 (Development of High Precision Underground Water Level Meter Using a Buoyant Rod Load Cell Technique)

  • 이부용;박병윤
    • 한국농림기상학회지
    • /
    • 제1권1호
    • /
    • pp.36-40
    • /
    • 1999
  • A new method was developed to measure underground water level with high reliability. The principle of new method was to detect a change of a buoyant force according to change in water level of underground water measured by the use of a straingage load cell. Field test of the instrument was carried out in Cheju Island. The results were as follows; 1) The present study provided a possibility to develop a new underground water level meter. 2) This new instrument accomplished high reliability at field test in Cheju Island. 3) There is possibility of development of water level meter which measure various range of water level to detect a weight change of a buoyant forcd.

  • PDF