Assessment of Fuzzy Measure Possibility for the Electromagnetic Field according to Voltage fluctuation of the Jechon Area  

Kim, Sang-Chul (Department of Safety Engineering, Semyung University)
Publication Information
Journal of the Korean Society of Safety / v.20, no.2, 2005 , pp. 50-55 More about this Journal
Abstract
This Paper Presents assessment of fuzzy measure Possibility far the electromagnetic field according to voltage fluctuation of the Jechon Area. To cope with substantial electromagnetic analysis, the safety assessment were analyzed the double 154kV T/L, 345kV T/L, Jechon-Ichon Jechon-Youngju, respectively. As the results of case study, in case of 345kV T/L, the electric field value was 11.4927kV/m, magnetic field value was 0.4622G at the Point about 7m away from the line in severest case. Tn assessment of fuzzy measure Possibility for the electromagnetic field, this paper use probability of fuzzy and measure of fuzziness technique.
Keywords
electromagnetic field; fuzzy measure possibility; probability; fuzziness;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김상철, '계통상태를 고려한 ELF 전자계해석 및 인체안전평가', 박사학위논문, 충북대학교, 1995
2 H.J. zimmermann, 1991, 'Fuzzy Set theory and Its Application', Kluwer Academic Publishers
3 T. M. McCauley et al., 'EHV and UHV electrostatic effect: Simplified design calculations and preventive measures,' IEEE Trans. Power App. Syst., Vol. PAS-94, No. 6, Nov./Dec. 1975
4 T. M. Mccauley, 'EHV and UHV Electrostatic Effect : Simplified Design Calculations and Preventive Measures', IEEE Trans. Power App. Syst., Vol. Pas-93, No. 5, Sept. 1974
5 Kun-Mu Chen et al., 'Quentification of interaction between ELF-LF electric fields and human bodies', IEEE Trans. Biomed. Eng., Vol. BME-33, No. 8, Aug. 1986
6 Klir, G. J., and Folger, T. A., 'Fuzzy Sets, Uncertainty, and Information', Prentice Hall: Nwe Jersey, 1988
7 G. D. Irisarri, A. M. Sasson, 'An automatic contingency selection method for on-line security analysis', IEEE Trans. Power App. Syst., Vol. PAS-100, April, 1981
8 R. G. Olsen et al., 'On the Exact, Carson and Image Theoried for Wires at or Above the Earth's Interface', IEEE Trans. Power App. Syst., Vol. Pas-102, No. 45, April. 1983
9 T. A. Mikolinnas, B. F. Wollenberg, 'An advanced contingency selection algorithm', IEEE Trans. Power App. Syst., Vol. PAS-100, No. 2, February, 1981
10 D.W. Zipse, 'Health Effects of Extremely Low - Frequency (50 and 60-Hz) Electric and Magnetic Fields,' IEEE Trans. Indus. App., Vol. 29, No. 2, MARCH/APRIL, 1993
11 K. T. Khu, M. G. Lauly, D. W. Bowen, 'A fast linearization method to evaluate the effect of circuit contingencies upon system load bus voltage', IEEE Trans. on Vol. PAS-101, No. 10, October, 1982
12 F. Albuyeh, A. Bose, B. Heath, 'Reactive power consideration in automatic contingency selection', IEEE Trans. on Vol. PAS-103, January, 1984
13 김상철 외 2, '계통상태를 고려한 ELF 전자계의 인체안전평가를 위한 퍼지언어변수 접근법', 한국산업안전학회지, Vol. 12, No. 2, pp. 70-79,1997