• Title/Summary/Keyword: Positron

Search Result 644, Processing Time 0.023 seconds

18F-2-Deoxy-2-Fluoro-D-Glucose Positron Emission Tomography: Computed Tomography for Preoperative Staging in Gastric Cancer Patients

  • Youn, Seok Hwa;Seo, Kyung Won;Lee, Sang Ho;Shin, Yeon Myung;Yoon, Ki Young
    • Journal of Gastric Cancer
    • /
    • v.12 no.3
    • /
    • pp.179-186
    • /
    • 2012
  • Purpose: The use of 18F-2-deoxy-2-fluoro-D-glucose positron emission tomography-computed tomography as a routine preoperative modality is increasing for gastric cancer despite controversy with its usefulness in preoperative staging. In this study we aimed to determine the usefulness of preoperative positron emission tomography-computed tomography scans for staging of gastric cancer. Materials and Methods: We retrospectively analyzed 396 patients' positron emission tomography-computed tomography scans acquired for preoperative staging from January to December 2009. Results: The sensitivity of positron emission tomography-computed tomography for detecting early gastric cancer was 20.7% and it was 74.2% for advanced gastric cancer. The size of the primary tumor was correlated with sensitivity, and there was a positive correlation between T stage and sensitivity. For regional lymph node metastasis, the sensitivity and specificity of the positron emission tomography-computed tomography were 30.7% and 94.7%, respectively. There was no correlation between T stage and maximum standardized uptake value or between tumor markers and maximum standardized uptake value. Fluorodeoxyglucose uptake was detected by positron emission tomography-computed tomography in 24 lesions other than the primary tumors. Among them, nine cases were found to be malignant, including double primary cancers and metastatic cancers. Only two cases were detected purely by positron emission tomography-computed tomography. Conclusions: Positron emission tomography-computed tomography could be useful in detecting metastasis or another primary cancer for preoperative staging in gastric cancer patients, but not for T or N staging. More prospective studies are needed to determine whether positron emission tomography-computed tomography scans should be considered a routine preoperative imaging modality.

Positron Annihilation Study of Vacancy Type Defects in Ti, Si, and BaSrFBr:Eu

  • Lee, Chong Yong
    • Applied Science and Convergence Technology
    • /
    • v.25 no.5
    • /
    • pp.85-87
    • /
    • 2016
  • Coincidence Doppler broadening and positron lifetime methods in positron annihilation spectroscopy has been used to analyze defect structures in metal, semiconductor and polycrystal, respectively. The S parameter and the lifetime (${\tau}$) value show that the defects were strongly related with vacancies. A positive relationship existed between the scanning electron microscope (SEM) images and the positron annihilation spectroscopy (PAS). According to the SEM images and PAS results, measurements of the defects with PAS indicate that it was more affected by the defect than the purity.

Positron Annihilation Lifetime Study on the Proton-Irradiation BaSrFBr : Eu Film (양전자 소멸 수명 측정에 의한 양성자 조사된 BaSrFBr : Eu 박막 특성)

  • Im, Yu-Suk;Lee, Chong-Yong
    • Korean Journal of Materials Research
    • /
    • v.20 no.6
    • /
    • pp.307-311
    • /
    • 2010
  • Positron annihilation lifetime spectroscopy is applied to BaSrFBr : Eu film which is used for the phosphore layer, and afterwards the reliability and self-consistency of source corrections in the positron lifetime spectroscopy is investigated using a $^{22}Na$ positron emitter covered by thin foils. The positron lifetime showed no significant change through the various proton irradiation energies. It is unusual that the measurements of the defects indicate that most of the defects were likely to have been generated by X-ray radiation. This may have resulted from the Bragg peaks of the proton characteristics. The Bragg peak does not affect the defect signals enough to distinguish the lifetimes and intensities in a material that is includes multi-grains. The lifetime ($\tau_1$) associated with positron annihilations in the Ba, Br, and Eu of the sample was about 250 ps, and due to the annihilations at F-centers or defects from the irradiated protons in sample, the lifetime ($\tau_2$) was about 500 ps.

Line Image Correction of the Positron Camera in the Secondary Beam Course of HIMAC

  • Iseki, Yasushi;Mizuno, Hideyuki;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Tomitani, Takehiro;Urakabe, Eriko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.195-198
    • /
    • 2002
  • A positron camera, consisting of a pair of Anger-type scintillation detectors, has been developed for verifying the ranges of irradiation beams in heavy-ion radiotherapy. Images obtained by a centroid calculation of photomultiplier outputs exhibit a distortion near the edge of the crystal plane in an Anger-type scintillation detector. The images of a $\^$68/Ge line source were detected and look-up tables were prepared for the position correction parameters. Asymmetry of the position distribution detected by the positron camera was prevented with this correction. As a result, a linear position response and a position resolution of 8.6 mm were obtained over a wide measurement field.

  • PDF

Resolution Improvement of the Positron Computerized Tomographic System with Hardware Approach and Superresolution Technique

  • Hong, Ki-Sang;Ra, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1979.08a
    • /
    • pp.162-163
    • /
    • 1979
  • A new detector array scheme for the positron camera for tile improved image resolution and a method for the resolution improvement of the undersampled projection data from ring positron camera are proposed. Computer simulation results are presented and problems ana limitations are discussed.

  • PDF

Theoretical Study of Positronium Atoms Using Frozen Gaussian-type Geminals

  • Takatsuka, Akio;Ten no, Seiichiro
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.6
    • /
    • pp.859-863
    • /
    • 2003
  • We report on the theoretical positron affinities of closed-shell atomic anions. The second-order many-body perturbation theory is applied taking the positron-electron interaction as a perturbation. The corrections for the complete basis set effects to the second order affinity are calculated based on the variational and nonvariational energy functionals of explicitly correlated geminals. It is shown that the explicitly correlated methods accelerate the convergence of the expansion significantly giving the account of the cusp behavior outside the orbital space.

The Role of PET in Lung Cancer (폐암에서 PET의 역할)

  • Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.28-33
    • /
    • 2002
  • Lung cancer has become a loading cause of cancer death in Korea. Positron emission tomography was introduced in clinical nuclear medicine in the early 1990s and many studios using this functional imaging technology were performed for evaluation of its clinical utility. I review the current role of positron emission tomography in the diagnosis, staging, and therapy monitoring of lung cancer.

Iterative Attenuation Correction and Image Reconstruction Using Time-Of-Flight Positron Emission Tomography (양전자방출단층촬영기의 비행시간정보를 이용한 반복적 감쇠보정 및 영상재구성)

  • Lee, Nam-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.8
    • /
    • pp.1371-1376
    • /
    • 2016
  • In this paper, an iterative method is proposed to perform attenuation correction and image reconstruction simultaneously for positron emission tomography, by using the time-of-flight information. Numerical simulation results are presented to demonstrate an improved performance of the proposed method in attenuation correction and image reconstruction.

Investigation of Proton Irradiated Effect on n, p type Silicon by Positron Annihilation Method (양전자 소멸 측정에 의한 n, p형 실리콘 구조 특성)

  • Lee, C.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.225-232
    • /
    • 2012
  • It is described that the proton beam induceds micro-size defects and electronic deep levels in n or p type single crystal silicon. Positron lifetime and Coincidence Doppler Broadening Positron Annihilation Spectroscopy were applied to study of characteristics of p type and n type silicon samples. In this investigation the numerical analysis of the Doppler spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the spectrum and the total counts of whole spectrum. The samples were exposed by 3.98 MeV proton beams ranging between 0 to ${\sim}10^{14}$ particles. The S-parameter values strongly depend on the irradiated proton beam, that indicated the defects generate more. Positron lifetime shows that positrons trapped in vacancies and lifetime ${\tau}_2$ increased according to proton irradiation.