• Title/Summary/Keyword: Positive-sequence

Search Result 868, Processing Time 0.033 seconds

Identification of Positive and Negative Regulatory Elements of the Human Cytochrome P4501A2 (CYP1A2) Gene

  • Chung, Injae;Jeong, Choonsik;Jung, Kihwa;Bresnick, Edward
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1997.04a
    • /
    • pp.81-81
    • /
    • 1997
  • We previously demonstrated an enhancer-like positive regulatory element within a 259-bp sequence (-2352 to-2094 bp) of the human CYP1A2 gene in HepG2 cells. Three protein binding sites were identified by DNase I footprint analyses within the 259-bp sequence: protected region A PRA ( -2283 to-2243 bp), PRB (-2218 to-2187 bp), and PRC (-2124 to-2098 bp) (I. Chung and E. Bresnick, Mol. Pharmacol. 47, 677-685, 1995). In the present study, the functional significance of those protected regions was examined. Transfection experiments with deletion and substitution mutants defined the PRB and PRC as containing positive and negative regulatory elements, respectively. Human breast carcinoma MCF-7 cells were cotransfected with a hepatocyte nuclear factor-1 (HNF-1) expression vector and CYP1A2 promoter-or thymidine kinase promoter-luciferase remoter gene constructs. HNF-1, which contributes to the liver specificity of genes, enhanced reporter gene activity in a PRC sequence-dependent manner. These results suggested that PRC could exist bound to a repressor which was displaceable by other transcription factors such as HNF-1. Results obtained by transfection of HepG2 hepatoma cells with various PRB substitution mutant-luciferase gene fusion constructs indicated that the entire sequence of PRB was necessary for promoter activity. Consequently, the regulation of CYP1A3 expression is very complex, requiring a number of both positive and negative regulatory factors.

  • PDF

An Integrated Compensation Algorithm for PCC Voltage Fluctuation and Unbalance with Variable Limit of Positive and Negative Sequence Currents

  • Im, Ji-Hoon;Song, Seung-Ho;Cho, Sung-Min
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.751-760
    • /
    • 2017
  • This paper proposes a point of common coupling (PCC) voltage compensation algorithm using a current limitation strategy for use in distributed generation (DG). The proposed strategy maintains the PCC voltage by prioritizing currents when an output current reference is larger than the current capacity of the power condition system (PCS) of the DG. With this strategy, the DG outputs the active current, reactive current, and the negative sequence current. The DG uses the reactive current for maintaining the PCC voltage within a normal range; the negative sequence current is used for reducing the PCC voltage unbalance. The proposed method was verified using PSIM simulation and experimental results.

VPI-based Control Strategy for a Transformerless MMC-HVDC System Under Unbalanced Grid Conditions

  • Kim, Si-Hwan;Kim, June-Sung;Kim, Rae-Young;Cho, Jin-Tae;Kim, Seok-Woong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2319-2328
    • /
    • 2018
  • This paper introduces a control method for a transformerless MMC-HVDC system. The proposed method can effectively control the grid currents of the MMC-HVDC system under unbalanced grid conditions such as a single line-to-ground fault. The proposed method controls the currents of the positive sequence component and the negative sequence component without separating algorithms. Therefore, complicated calculations for extracting the positive sequence and the negative sequence component are not required. In addition, a control method to regulate a zero sequence component current under unbalanced grid conditions in the transformerless MMC-HVDC system is also proposed. The validity of the proposed method is verified through PSCAD/EMTDC simulation.

Phase Selection Algorithm using Sequence Voltages for Transmission Line Protection (대칭분 전압을 이용한 송전선로 보호용 고장상 선택 알고리즘)

  • Lee, Myoung-Soo;Kim, Soo-Nam;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.124-126
    • /
    • 2001
  • A reliable fault type identification (phase selection) plays a very important role in transmission line protection, particularly in Extra High Voltage(EHV) networks. The conventional fault type identification algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and identify the fault type in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can identify the accurately fault type using the sum of unit vectors which are calculated by positive-sequence votage and negative-sequence voltage.

  • PDF

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

Study on PWM Converter Control under Unbalanced Network Condition

  • Sastrowijoyo, Fajar;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.524-526
    • /
    • 2011
  • This paper focuses on study on PWM converter control under unbalanced network condition. Voltage unbalance in a three-phase system causes the performance deterioration by producing 120 Hz voltage ripples in the DC link and 120 Hz ripple in reactive power. To eliminate the ripples, both positive and negative sequence currents should be controlled simultaneously. In this paper four PI controllers on synchronous reference frame is implemented to control D and Q currents in both positive and negative sequence. Positive and negative sequence signal extraction is done using delay signal cancellation method. Simulation results show satisfactory performance in suppressing 120 Hz ripples.

  • PDF

A Central Limit Theorem for a Stationary Linear Process Generated by Linearly Positive Quadrant Dependent Process

  • Kim, Tae-Sung;Ko, Mi-Hwa
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.1
    • /
    • pp.153-158
    • /
    • 2001
  • A central limit theorem is obtained for stationary linear process of the form -Equations. See Full-text-, where {$\varepsilon$$_{t}$} is a strictly stationary sequence of linearly positive quadrant dependent random variables with E$\varepsilon$$_{t}$=0, E$\varepsilon$$^2$$_{t}$<$\infty$ and { $a_{j}$} is a sequence of real numbers with -Equations. See Full-text- we also derive a functional central limit theorem for this linear process.ocess.s.

  • PDF

A Weak Convergence for a Linear Process with Positive Dependent Sequences

  • Kim, Tae-Sung;Ryu, Dae-Hee;Lee, Il-Hyun
    • Journal of the Korean Statistical Society
    • /
    • v.31 no.4
    • /
    • pp.483-490
    • /
    • 2002
  • A weak convergence is obtained for a linear process of the form (equation omitted) where {$\varepsilon$$_{t}$ } is a strictly stationary sequence of associated random variables with E$\varepsilon$$_{t}$ = 0 and E$\varepsilon$$^{^2}$$_{t}$ < $\infty$ and {a $_{j}$ } is a sequence of real numbers with (equation omitted). We also apply this idea to the case of linearly positive quadrant dependent sequence.

Development of Inter Turn Short Fault Model of IPM Motor (IPM모터의 턴쇼트 고장모델에 관한 연구)

  • Gu, Bon-Gwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.305-312
    • /
    • 2015
  • In this study, inter-turn short fault models of interior permanent magnet synchronous motors (IPMSM) are developed by adding saliency modeling to surface-mounted permanent magnet motor models. The saliency model is obtained using the deformed flux models based on both fault-winding flux information and inductance variations caused by cross-flux linkages that depend on the distribution of the same phase windings. By assuming the balanced three-phase current injection, we obtain the positive and negative sequence voltages and the fault current in the positive and the negative synchronous reference frames. The output torque model is developed by adding the magnet and the reluctance torque, which are derived from the developed models. To verify the proposed IPMSM model with an inter-turn short fault, finite element method-based simulation and experimental measurement results are presented.

PERIODICITY AND ATTRACTIVITY FOR A RATIONAL RECURSIVE SEQUENCE

  • ZHANG LIJIE;ZHANG GUANG;LIU HUI
    • Journal of applied mathematics & informatics
    • /
    • v.19 no.1_2
    • /
    • pp.191-201
    • /
    • 2005
  • In this paper, the existence of periodic positive solution and the attractivity are investigated for the rational recursive sequence $x_{n+1} = (A + ax_{n_k})/(b + x{n-l})$, where A, a and b are real numbers, k and l are nonnegative integer numbers.