• Title/Summary/Keyword: Positive polarity

Search Result 193, Processing Time 0.025 seconds

An ab Initio Predictive Study on Solvent Polarity (용매 극성도의 이론적 예측 연구)

  • Park, Min-Kyu;Cho, Soo-Gyeong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.154-160
    • /
    • 2008
  • We investigated molecular polarity by using theoretical means and comparing empirical solvent polarity. Our approach employed electrostatic potentials at the molecular surface calculated by density functional methods. A number of molecular descriptors related to molecular polarities were computed from molecular surface electrostatic potentials. Among computed molecular descriptors, the most positive electrostatic potential provided the best correlation with the empirical solvent polarities. A regression equation was developed in order to predict molecular polarities of molecules whose experimental solvent polarities were unknown. The new regression equations were utilized in estimating solvent polarities of cubane derivatives which are considered important precusors of high-energy density meterials.

Influence of SF6/N2 Gas Mixture Ratios on the Lightning Streamer Propagation Characteristics of 22 kV MV Circuit Breaker

  • Gandhi, R.;Chandrasekar, S.;Nagarajan, C.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1663-1672
    • /
    • 2018
  • In recent times, gas insulated medium voltage (MV) circuit breakers (CB) form a vital component in power system network, considering its advantages such as reduced size and safety margins. Gas insulation characteristics of circuit breakers are generally measured by lightning impulse (LI) test according to IEC standard 60060-1 as a factory routine test. Considering the environmental issues of $SF_6$ gas, many research works are being carried out towards the mixture of $SF_6$ gases for high voltage insulation applications. However, few reports are only available regarding the LI withstand and streamer propagation characteristics (at both positive and negative polarity of waveform) of $SF_6/N_2$ gas mixture insulated medium voltage circuit breakers. In this paper, positive and negative polarity LI tests are carried out on 22 kV medium voltage circuit breaker filled with $SF_6/N_2$ gas mixture at different gas pressures (1-5 bar) and at different gas mixture ratios. Important LI parameters such as breakdown voltage, streamer velocity, time to breakdown and acceleration voltage are evaluated with IEC standard LI ($1.2/50{\mu}s$) waveform. Weibull distribution analysis of LI breakdown voltage data is carried out and 50% probability breakdown voltage, scale parameter and shape parameter are evaluated. Results illustrate that the $25%SF_6+75%N_2$ gas filled insulation considerably enhances the LI withstand and breakdown strength of MV circuit breakers. LI breakdown voltage of circuit breaker under negative polarity shows higher value when compared with positive polarity. Results show that maintaining the gas pressure at 0.3 MPa (3 bar) with 10% $SF_6$ gas mixed with 90% $N_2$ will give optimum lighting impulse withstand performance of 22 kV MV circuit breaker.

Characteristics of lightning impulse breakdowns in inhomogeneous $SF_6$ gas gap (불평등전장에서 $SF_6$ 기체의 뇌임펄스 절연파괴특성)

  • Lee, B.H.;Choi, H.S.;Oh, S.K.;Li, F.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1921-1923
    • /
    • 2004
  • V-p characteristics and the discharge luminous characteristics in inhomogeneous $SF_6$ gas gap under the positive and negative lightning impulse voltages are presented. The test gap was composed of the plane-to-plane with a needle-shaped protrusion. The applied voltage and the predischarge current were measured by the electric field sensor and the shunt of 50 ${\Omega}$, respectively. The light emission signals were observed by a photomultiplier tube, and a high-speed camera. In a consequence, the dielectric strengths of $SF_6$ gas gap under positive lightning impulse voltages were independent of the gas pressure. In the presence of the positive polarity, the branches of discharge channel were created and the directions of the discharge paths were random. On the other hands, the discharge paths of the negative polarity were more thicker and brighter.

  • PDF

EFFECT OF SOLVENT POLARITY ON THE FLUORESCENCE QUENCHING OF ORGANIC LIQUID SCINTILLATORS BY ANILINE

  • Shailaja, M.K.;Hanagodimath, S.M.;Kadadevarmath, J.S.;Chikkur, G.C.
    • Journal of Photoscience
    • /
    • v.6 no.4
    • /
    • pp.159-163
    • /
    • 1999
  • The fluorescence quenching of 2-phenyl-5-(4-biphenylyl)-1,3,4-oxadiazole (PBD) and 1,4-di-[2-(5-phenyloxazolyl)]-benzene (POPOP) by aniline has been carried out in different solvent mixtures of dioxane and acetonitrile at room temperature. The quenching is found to be appreciable and a positive deviation from linearity was observed in the Stern-Volmer plot in all the solvent mixtures. Various rate constants for the quenching processes have been determined using a modified Stern-Volmer equation. From the positive deviations of linear Stern-Volmer plots and the dependence of rate constants on the polarity of the solvents, it has been concluded that both static and dynamic quenching processes are responsible for the observed positive deviation in the Stern-Volmer plot.

  • PDF

Comparison of the Center for Children's Foodservice Management in 2012, 2014, and 2016 Using Big Data and Opinion Mining (2012년, 2014년과 2016년의 어린이급식관리지원센터에 대한 빅데이터와 오피니언 마이닝을 통한 비교)

  • Jung, Eun-Jin;Chang, Un-Jae
    • Journal of the Korean Dietetic Association
    • /
    • v.23 no.2
    • /
    • pp.192-201
    • /
    • 2017
  • This study compared the Center for Children's Foodservice Management in 2012, 2014, and 2016 using big data and opinion mining. The data on the Center for Children's Foodservice Management were collected from the portal site, Naver, from January 1 to December 31 in 2012, 2014, & 2016 and analyzed by keyword frequency analysis, influx route analysis of data, polarity analysis via opinion mining, and positive and negative keyword analysis by polarity analysis. The results showed that nursery had the highest rank every year and education supported by Center for Children's Foodservice Management has increased significantly. The influx of data has increased through the influx route analysis of data. Blog and $caf\acute{e}e$, which have a considerable amount of information by the mother should be helpful for use as public relations and participation recruitment paths. By polarity analysis using opinion mining, the positive image of the Center for Children's Foodservice Management was increased. Therefore, the Center for Children's Foodservice Management was well-suited to the purpose and the interests of the people has been increasing steadily. In the near future, the Center for Children's Foodservice Management is expected have good recognition if various programs to participate with family are developed and advertised.

Basic Rotation Characteristics and Energy Efficiencies of a Blade-Type Corona Motor (날개전극형 코로나 모터의 기초 회전특성 및 에너지 효율)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1862-1868
    • /
    • 2010
  • A corona motor, as one of a powerful cooling means of microelectronic devices, has been employed because of its very simple structure of no coils and no brushes. In this paper, the effect of polarity of applied voltage and the number of blade corona electrodes on the fundamental properties of rotation of the motor was investigated. The I-V and rotation characteristics of the blade corona electrode were significantly different from the different polarities of applied voltages and the blade corona electrode numbers, due to the different space charge effect resulted by the different migration mobility of the positive and negative ions generated near the blade corona electrode tip of the rotor of the motor. The rotation speed of the motor was influenced significantly by the polarity of corona discharge, the number of blades, and mass of rotor. At the same corona current, an effective rotation can be obtained with the positive corona caused by the lower ion mobility. On the other hand, the higher rotation speed can be obtained with the negative corona resulted from its higher corona current. The highest rotation speed and energy efficiency can be obtained with the rotor having 4 blades.

The Treeing Deterioration with Prestressed D.C Voltage in Low Density Polyethylen Mixed with Organic Compounds (유기물이 첨가된 저밀도 폴리에칠렌에서 예비과전에 따른 트리잉 열화)

  • 채홍인;양계준;임기조
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.2
    • /
    • pp.15-20
    • /
    • 1991
  • In this paper, we have investigated the effect of organic additives and prestressed D C. voltage on the impulse tree initiation in low density polyethylene. The five klnds of organic compounds was selected for the purpose of inhibiting tree initiation and 10 wt % of each additive was mixed in low density polyethylene. The positive or negative impulse voltage was applied after prestressed D.C. voltage was applied in order to investigate the effect of the space charge influenced on tree initiation. The lengths of tree initiation in case of belng same polarity between prestressed D.C. voltage and impulse voltage were longer than those in case of being different polarity between prestressed D.C. voltage and impulse voltage. When the polarity prestressed D.C. voltage was the different plarity of impulse voltage, the length of tree initiation increased with increasing the prestressed D.C. voltage and decreasing the rest time Among the organic additives used in this paper, the m-cresol can be shown to be the most effective inhibiter to tree initiation.

  • PDF

A Study on the Space Charge Measurement Technique and Carrier Polarity of Insulating Materials on Power Cable (전력케이블용 절연재료의 캐리어 극성 및 공간전하 측정기술에 관한 연구-PE-EVA에서의 하전입자의 거동)

  • 국상훈;박중순;강용철;권영수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.2
    • /
    • pp.185-191
    • /
    • 1992
  • In this paper, it is attempted to distinguish the charged particles and to judge the polarity by the use of Thermally Stimulated Current(TSC) and Temperature Gradient Thermally Stimulated Surface Potential Measurement(TG-TSSP)with experimental insulation material XLPE-EVA for power cables which is made by blending cross-linked polyethylene(XLPE) and ethylene-vinylacetate copolymer(EVA). In addition, it is performed to investigate the effect of EVA blending. From the experimental results, it is known that for the case of XLPE-EVA blended experimental material, the generation of space charged electric field is not obtained in the high temperature region due to the obatruction of the injection of trapping carrier by the electron and the positive hole.

  • PDF

Characteristics of lightning impulse pre-breakdown discharge in $SF_6\;and\;SF_6/CO_2$ mixtures ($SF_6$$SF_6/CO_2$ 혼합기체 중에서의 뇌임펄스 전구방전의 특성)

  • Lee, Bok-Hee;Oh, Sung-Kyun;Baek, Young-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.57-60
    • /
    • 2005
  • This paper describes the experimental results of the pre-breakdown phenomena in $SF_6/CO_2$ mixtures under non-uniform electric fields caused by positive and negative lightning negative voltages. $SF_6/CO_2$ mixtures have an advantage of an environmental aspect and cost reduction, and safety aspects. In order to analyze the pre-breakdown processes in $SF_6/CO_2$ mixtures stressed by impulse voltages, pre-breakdown current and luminous signals were measured by a shunt and a photo-multiplier tube, respectively. Dielectric strengthes of $SF_6/CO_2$ mixtures were investigated. Additionally, characteristics of discharge channels were observed by high speed cameras and the physical properties were discussed. The pre-breakdown propagates with a stepwise process. The in to breakdown from the corona onset point in positive polarity was shorter than that in negative polarity. The time intervals of positive leaders are shorter than those of negative leaders, and the path of positive leader channel is zigzag.

  • PDF

Impulse breakdown Characteristics in SF6/N2, Gas Mixtures with a Temperature Variation (온도변화에 따른 SF6/N2 혼합가스의 임펄스 절연파괴특성)

  • Li, Feng;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.79-86
    • /
    • 2008
  • This paper presents the experimental results of impulse breakdown characteristics in $SF_6/N_2$ gas mixtures under a highly non-uniform electric field with a change in temperature. The test temperature ranges from -25[$^{\circ}C$] to 25[$^{\circ}C$]. The processes of impulse preliminary breakdown developments were analyzed by the measurements of current pulse and luminous signals. As a result, the temperature dependance of breakdown voltage for the negative polarity was much stronger than that for the positive polarity. When increasing the temperature, The leader stepping time for the negative polarity was shown to be longer than that for the positive polarity. The results presented in this paper can be used as a useful information in designing the gas insulation lines with prominent ability for lightning surge.