• Title/Summary/Keyword: Portable radiation system

Search Result 51, Processing Time 0.028 seconds

Full-digital portable radiation detection system (디지털 휴대용 방사능 검출 시스템)

  • Lee, Seok Jae;Kim, Young Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.315-318
    • /
    • 2015
  • in recently the world trend of security system for shipping transport is much more important and stronger, so following the world trend, there is development to security system of shipping transport for national security logistics system construction. it is still ongoing. For the world trend of security system, there is attempt of portable radiation detection, which is possible to get detection of nuclide in south Korea. in this Paper, it will shows about Full-digital system to portable radiation detection platform.

  • PDF

Research of Detection performance enhancement from portable radiation detection platform based on Cortex-A9 (Cortex-A9 기반 휴대용 방사선 검출장치에서의 검출성능 향상을 위한 연구)

  • Kwon, Tae-Kyung;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.6
    • /
    • pp.1488-1493
    • /
    • 2014
  • Shipping and logistics safety, security system is strengthening worldwide, the development of shipping and logistics safety security core technology for national security logistics system construction has been carried out. Interest in portable radiation detection device capable detecting gamma rays nuclides is increasing. In this paper, I would like to propose the study of resolution enhancement for accurate analysis of nuclides in the platform of the radiation detector portable with Cortex-A9.

Implementation of Digital Portable Radiation Detector with the Algorithm of Temperature Compensation (온도 보정 Algorithm을 적용한 Digital 휴대용 방사선 검출기의 구현)

  • Park, Ge-O;Lee, Jung-Hyun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.202-205
    • /
    • 2016
  • Shipping and logistics safety, security system is strengthening worldwide, the development of shipping and logistics safety security core technology for national security logistics system construction has been carried out. Interest in portable radiation detection device capable detecting gamma rays nuclides is increasing. In this paper, I would like to propose the study of implementation of digital portable radiation detector with the algorithm of temperature compensation.

  • PDF

Research of Resolution enhancement from portable radiation detection platform based on Cortex-A9 (Cortex-A9 기반 휴대용 방사선 검출장치에서의 분해능 향상을 위한 연구)

  • Kwon, Tae-Kyung;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.373-376
    • /
    • 2014
  • Shipping and logistics safety, security system is strengthening worldwide, the development of shipping and logistics safety security core technology for national security logistics system construction has been carried out. Interest in portable radiation detection device capable detecting gamma rays nuclides is increasing. In this paper, I would like to propose the study of resolution enhancement for accurate analysis of nuclides in the platform of the radiation detector portable with Cortex-A9.

  • PDF

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

Development of a Portable Device Based Wireless Medical Radiation Monitoring System (휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발)

  • Park, Hye Min;Hong, Hyun Seong;Kim, Jeong Ho;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.150-158
    • /
    • 2014
  • Radiation-related practitioners and radiation-treated patients at medical institutions are inevitably exposed to radiation for diagnosis and treatment. Although standards for maximum doses are recommended by the International Commission on Radiological Protection (ICPR) and the International Atomic Energy Agency (IAEA), more direct and available measurement and analytical methods are necessary for optimal exposure management for potential exposure subjects such as practitioners and patients. Thus, in this study we developed a system for real-time radiation monitoring at a distance that works with existing portable device. The monitoring system comprises three parts for detection, imaging, and transmission. For miniaturization of the detection part, a scintillation detector was designed based on a silicon photomultiplier (SiPM). The imaging part uses a wireless charge-coupled device (CCD) camera module along with the detection part to transmit a radiation image and measured data through the transmission part using a Bluetooth-enabled portable device. To evaluate the performance of the developed system, diagnostic X-ray generators and sources of $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, and $^{90}Sr$ were used. We checked the results for reactivity to gamma, beta, and X-ray radiation and determined that the error range in the response linearity is less than 3% with regard to radiation strength and in the detection accuracy evaluation with regard to measured distance using MCNPX Code. We hope that the results of this study will contribute to cost savings for radiation detection system configuration and to individual exposure management.

Full-digital portable radiation detection system (디지털 휴대용 방사능 검출 시스템)

  • Oh, Jae-kyun;Lee, Seok-Jae;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1436-1442
    • /
    • 2015
  • In recently the world trend of security system for shipping transport is much more important and stronger, so following the world trend, there is development to security system of shipping transport for national security logistics system construction. it is still ongoing. For the world trend of security system, there is attempt of portable radiation detection, which is possible to get detection of nuclide in south Korea.

Realization of single supply to reduce power on portable radiation detection device (소모전력 감소를 위한 단일 전원 휴대용 방사선 검출장치 구현)

  • Oh, Jae-Kyun;Nam, Hye-Jin;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.1024-1030
    • /
    • 2015
  • Safety and security system have been internationally enhanced in a field of shipping logistics. Accordingly, techniques for safety and security have been studied steadily. The need of portable radiation detection device is increasing by the search of the container is enhanced. In this paper, we propose a study to improve the life of the system and the realization of portable radiation detection device based on Cortex-A9. Configuration of a portable radiation detection device is configured largely to an analog board and the digital platform and the sensor module. The power used in each stage of the analog board is varied. Uses a switching regulator to use various power supply thereby to generate an error result and cause the switching noise. It is proposed to reduce the power consumption reducing technique for the study.

Peak detection algorithm at time domain of full-digital portable radiation detection system (휴대용 방사능 검출기의 시간 영역에서의 최고값 검출 알고리즘)

  • Hwang, Dong Gyu;Kim, Young Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.323-325
    • /
    • 2015
  • The purpose of the thesis is to suggest the algorithm that can be covered only by software instead of the function of pulse shaper that was used in the time domain. In order to implementing portable radiation detector for digital.

  • PDF

Development of Radiation Detector with Intensifying Screen (증감지를 이용한 방사선검출기 개발)

  • Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.859-863
    • /
    • 2023
  • In this study, simple and portable radiation detection system using X-ray intensifying screen, optical sensor and micro-controller unit for education was proposed. The system was simply composed of detection unit consisting of an optical sensor and intensifying screen, micro-controller unit, and was designed to be suitable for portable. Radiation was measured using developed detection system and absorbed dose dosimeter with changing tube voltage from 50 to 100 kVp. The tube current and SDD were fixed on 100 mAs and 100 cm, and dose were measured repeated ten times at each tube voltage. The response and linearity of the detection system were confirmed using the measured values. It was confirmed that the comparison measurement results of the detection system and absorbed dose dosimeter showed a high correlation(r : 0.998, p<.001). In this results, the feasibility of the detection system with intensifying screen and micro-controller unit based was confirmed, and we considered that the developed detection system could be applied to portable, compact, low cost system for education.