• 제목/요약/키워드: Portable instruments

검색결과 57건 처리시간 0.028초

무선 MEMS 센서를 이용한 보도교 진동 계측 (Vibration Measurements of Footbridges Using Wireless MEMS Sensor)

  • 이종호;천동진;윤성원
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.101-108
    • /
    • 2019
  • Recently, measuring instruments for SHM of structures has been developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to the absence of triboelectric noise and elimination of the requirement of a cumbersome cable. However, the low-cost wireless MEMS sensor has high noise density and transmits the signal wirelessly, so data transmission delay occurs during measurement. Therefore, the footbridges that was previously measured by a mobile phone in 2014 was remeasured using G-Link-200, iPad and iPhone to compare their performance.

휴대용 광이온화 검출기의 정확도, 정밀도 및 기기간 차이에 대한 실험실 평가 (Laboratory Evaluation of the Accuracy, Precision, and Inter-instrumental Variance of a Portable Photoionization Detector)

  • 최동민;최영은;윤충식;이광원;이윤근;이익모;박정임
    • 한국산업보건학회지
    • /
    • 제22권3호
    • /
    • pp.200-208
    • /
    • 2012
  • Objectives: This study investigated the performance of three separate units of a portable photoionization detector (PID, ppb-RAE 3000) for measuring volatile organic compounds (VOCs) in a laboratory. Methods: A laboratory evaluation of the accuracy, precision, and inter-instrumental variance of three separate units of a portable PID (ppb-RAE 3000) was performed. The evaluation was based on the preparation of a test air sample of known toluene or ethylacetate concentration in a Tedlar$^{(R)}$ bag. The test air sample was monitored and data were logged consecutively by the three PIDs. A certified gas of 50 ppm toluene was also monitored during the test to ensure the reliability of the generated test air sample. Four different concentrations ranging from 0.1 to 2 TLV were used and a series of five measurements for each concentration level was performed. The accuracy was evaluated using National Institute for Occupational Safety and Health (NIOSH) criteria. Results: The results from the oldest ppb-RAE3000 unit among the three test units generally fell outside the NIOSH recommended accuracy criteria of ${\pm}25%$, whereas the other two units produced results which were acceptable at, or greater than, 25 ppm of toluene, or 0.5 TLV. These units also met the NIOSH criteria for some ethylacetate measurements but the results were not consistent. Conclusions: Considering the inconsistent performance of these ppb-RAE 3000 units, this device may not be appropriate for use as an alternative to the standard measurement methods. However, it can serve good survey instruments to identify exposure sources or concentration profiles. For all applications, the ppb-RAE 3000 should be used with frequent calibration checks, additional validation using a reference material, and careful maintenance.

대형 금형의 품질관리를 위한 이동식 측정기 개발 (Development of a Portable Measurement Instrument for Quality Control of Large-sized Die)

  • 박종남
    • 한국산학기술학회논문지
    • /
    • 제15권4호
    • /
    • pp.1844-1849
    • /
    • 2014
  • 지금까지 금형의 표면관리를 위해 단순 현미경이나 표면 거칠기 측정기를 이용한 측정방법들은 구조적인 문제로 산업현장에서 적용하는 데 효율성이 떨어진다. 이에 따라 장소에 구별 없이 다양한 크기의 금형 측정과 품질관리 효율성을 높일 수 있는 측정시스템 및 분석시스템은 매우 필요하다. 본 연구는 이와 같은 필요성을 만족시키기 위한 현장맞춤형 이동식 표면측정 시스템 개발을 목표로 수행하였다. 측정시스템은 지지대(Base), 몸체(Body), 광학계(Opticalsystem)등 3부분으로 분리할 수 있도록 기구적으로 설계 및 제작하였다. 측정시스템의 실험결과 표면거칠기는 94.9~99.9%의 정확성을 나타냈으며, 원의 측정 값에 대한 편차는 $2{\mu}m$ 이내로 신뢰성을 확보하였다.

휴대용 원자 방출 분광계를 위한 제어 및 분석용 소프트웨어 개발 (Development of Controlling and Analyzing Software for Portable Atomic Emission Spectrometry)

  • 이상천;이장수;정민수;류동항
    • 분석과학
    • /
    • 제11권1호
    • /
    • pp.1-7
    • /
    • 1998
  • 본 논문은 현장에서 미량 원소분석을 수행할 수 있는 휴대용 원자방출분광계인 HCGD-AES(Hollow Cathode Glow Discharge-Atomic Emission Spectrometer)1에 적용할 분석 및 제어용 프로그램의 제작에 관한 연구결과를 요약하였다. 단색화 장치의 부피를 최소화할 수 있도록 분석할 원소의 선 필터(line filter)를 사용하여 제작된 검출계에서 실시간 분석이 가능한 소프트웨어의 개발이 이루어 졌으며, 원소 분석 및 검량선 작성의 자동화를 바탕으로 쉽게 사용할 수 있는 노트북용 소프트웨어를 Windows 95 환경에서 구현하였다. 사용한 주 언어인 Delphi 2.0을 바탕으로 그밖의 프로그램 언어도 복합적으로 사용되었다. 특히 측정된 자료들은 데이터 베이스를 구축하여 최적 실험 환경 조건을 얻을 수 있도록 하였으며 보고서 작성 기능도 추가되었다. 본 프로그램은 분석 수행에 있어서 사용자 편의를 위해 디자인되었으므로 빠르게 배우고 분광분석의 다른 분야에도 적용할 수 있도록 개발되어 응용성과 활용성이 대폭 확대될 수 있다는 이점이 있다.

  • PDF

지반조사를 위한 전자탐사의 적용 (Application of electromagnetic survey to geotechnical problems)

  • 조인기;송윤호
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 1999년도 제2회 학술발표회
    • /
    • pp.37-47
    • /
    • 1999
  • 전자탐사는 매우 다양한 탐사 방법론 및 탐사장비가 개발되어 있으며 그 적용 분야 또한 매우 넓다. 전자탐사는 탐사기법 및 사용되는 기기 즉, 특정 송${\cdot}$수신 배열이나 사용 주파수 대역 등에 따라 탐사심도 및 분해능이 서로 다른 결과를 제공한다 그러나 이러한 전자탐사 방법의 다양성은 주어진 문제를 해결할 수 있는 여러가지 기술 중 가장 적절한 방법을 선택할 수 있는 기회를 부여하므로 전자탐사의 중요한 장점중의 하나이다. 또한 현대의 전자탐사 측정장비는 그 복잡성에 비추어 장비의 이동성이 뛰어나다. 전자탐사는 최근 급속한 컴퓨터 기술의 발달에 힘입어 정확한 모델링 및 정밀 해석기술이 계속 개발됨에 따라 그 적용이 확대되고 있으며, 특히 지반조사 및 환경분야에의 적용이 활발히 추진되고 있다. 여기서는 다양한 전자탐사 방법 중에서 환경분야 및 지반조사에 효과적이고 현재 국내에서 수행 가능한 방법 및 조속한 시일 내에 국내에 도입 가능한 기술에 대하여 현장자료를 위주로 소개한다.

  • PDF

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

RF Energy Harvesting and Charging Circuits for Low Power Mobile Devices

  • Ahn, Chang-Jun;Kamio, Takeshi;Fujisaka, Hisato;Haeiwa, Kazuhisa
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권4호
    • /
    • pp.221-225
    • /
    • 2014
  • Low power RF devices, such as RFID and Zigbee, are important for ubiquitous sensing. These devices, however, are powered by portable energy sources, such as batteries, which limits their use. To mitigate this problem, this study developed RF energy harvesting with W-CDMA for a low power RF device. Diodes are required with a low turn on voltage because the diode threshold is larger than the received peak voltage of the rectifying antenna (rectenna). Therefore, a Schottky diode HSMS-286 was used. A prototype of RF energy harvesting device showed the maximum gain of 5.8dBi for the W-CDMA signal. The 16 patch antennas were manufactured with a 10 dielectric constant PTFT board. In low power RF devices, the transmitter requires a step-up voltage of 2.5~5V with up to 35 mA. To meet this requirement, the Texas Instruments TPS61220 was used as a low input voltage step-up converter. From the evaluated result, the achievable incident power of the rectenna at 926mV to operate Zigbee can be obtained within a distance of 12m.

Mass Spectrometric Analysis of Eight Common Chemical Explosives Using Ion Trap Mass Spectrometer

  • Park, Sehwan;Lee, Jihyeon;Cho, Soo Gyeong;Goh, Eun Mee;Lee, Sungman;Koh, Sung-Suk;Kim, Jeongkwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3659-3664
    • /
    • 2013
  • Eight representative explosives (ammonium perchlorate (AP), ammonium nitrate (AN), trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), cyclonite (RDX), cyclotetramethylenetetranitramine (HMX), pentaerythritol tetranitrate (PETN), and hexanitrostilbene (HNS)) were comprehensively analyzed with an ion trap mass spectrometer in negative ion mode using direct infusion electrospray ionization. MS/MS experiments were performed to generate fragment ions from the major parent ion of each explosive. Explosives in salt forms such as AP or AN provided cluster parent ions with their own anions. Explosives with an aromatic ring were observed as either $[M-H]^-$ for TNT and DNT or $[M]^{{\cdot}-}$ for HNS, while explosives without an aromatic ring such as RDX, HMX, and PETN were detected as an adduct ion with a formate anion, i.e., $[M+HCOO]^-$. These findings provide a guideline for the rapid and accurate detection of explosives once portable MS instruments become more readily available.

전자탐사를 이용한 지하 이상대 영상화

  • 조인기;김학수
    • 지구물리
    • /
    • 제5권2호
    • /
    • pp.99-109
    • /
    • 2002
  • 전자탐사는 매우 다양한 탐사 방법론 및 탐사 장비가 개발되어 있으며 그 적용 분야 또한 매우 넓다. 전자탐사는 탐사기법 및 사용되는 기기 즉, 특정 송 · 수신 배열이나 사용 주파수 대역 등에 따라 탐사심도 및 분해능이 서로 다른 결과를 제공한다. 또한 현대의 전자탐사 측정장비는 그 복잡성에 비추어 장비의 이동성이 뛰어나므로 지반조사 및 환경 오염대의 조사와 같은 지반 · 환경 물리탐사에 적용이 용이하다. 비록 전자탐사는 이론이 복잡하지만, 최근 급속한 컴퓨터 기술의 발달에 힘입어 정확한 모델링 및 역산 기법이 지속적으로 개발되고 있다. 여기서는 다양한 전자탐사 방법 중에서 환경분야 및 지반조사에 효과적이고 현재 국내에서 수행 가능한 방법 및 조속한 시일 내에 국내에 도입 가능한 전자탐사법의 원리 및 방법을 간략하게 소개하고 각 방법에 대한 현장자료를 소개한다.

  • PDF

TDLAS 시스템을 이용한 유해 배기가스의 농도 계측 (The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System)

  • 차학주;김민수;신명철;김세원;전광민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF