• Title/Summary/Keyword: Portable equipment

Search Result 235, Processing Time 0.024 seconds

The Design and Analysis of Scatternet Composition by The Number of Mobile Node in Radio Network Environment (무선 네트웍 환경에서 모발 노드수에 따른 스캐터넷 구성의 설계 및 분석)

  • Kim, Chang-Young;Jang, Jong-Wook
    • The Journal of Korean Association of Computer Education
    • /
    • v.5 no.3
    • /
    • pp.19-25
    • /
    • 2002
  • Bluetooth, in radio network environment, is a small local radio communication that is available with low expense and little power use. It is specified for the wireless connect in a small area between Network Excess Point, portable devices such as mobile phones. PDAs and portable PCs, and other per peripheral equipment. Bluetooth is consisted of a master and a piconet having seven slaves in a maximum and finally has a scatternet gathering lot of piconet. The thesis tries to design the most effective structure of a scatternet by the number of nodes and the type of scatternet such as linear and ring for its mechanism. then the performance evaluation is realized through the Bluehoc simulator based on the NS. Finally the most appropriate radio network environment is made by the comparison and analysis of the characteristics of liner and ring scatternets.

  • PDF

Implementation of a 32-Bit RISC Core for Portable Terminals (휴대 단말기용 32 비트 RISC 코어 구현)

  • Jung, Gab-Cheon;Park, Seong-Mo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.6
    • /
    • pp.82-92
    • /
    • 2001
  • This paper describes implementation of an embedded 32-Bit RISC core for portable communication/information equipment, such as cellular phones, PDA(Personal Digital Assistants), notebook, etc. The RISC core implements the ARM$\circled$V 4 instruction set, operates with typical 5-stage pipeline. It supports Thumb code to improve the code density, and uses the dynamic power management method of pipeline registers. It was modeled and simulated in RTL level using VHDL, and verified with ARMulator of ADS (Arm Developer Suite) and had average CPI of 1.44. The core is synthesized automatically using the cell library based on $0.6{\mu}m$ CMOS 1-poly 3-metal CMOS technology. It consists of about 41,000 gates and the clock frequency is expected to be above 45 MHz.

  • PDF

A Novel Authentication Protocol for Secure WiBro Services (안전한 WiBro 서비스를 위한 새로운 인증 프로토콜)

  • Koo, Jung-Sook;Kim, Jin-Geun;Bak, Jong-Hyeok;Koo, Jung-Doo;Lee, Gi-Sung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.05a
    • /
    • pp.224-227
    • /
    • 2008
  • 사용자가 안전한 WiBro 서비스를 받기 위해서 사용자 단말과 ACR(Access Control Router) 간에 인증이 선행되어야 한다. 그렇지 않을 경우, 많은 공격 위험으로부터 노출될 수 있다. 따라서 한국정보통신기술협회(TTA)에서는 휴대인터넷(와이브로$^{TM}$) 서비스를 위한 상호 인증 절차 표준을 제정하였다. 이 표준 프로토콜은 PISIM(Portable Internet Subscriber Identity Module)을 이용하여 PE(Portable Equipment)와 ACR 간에 상호 인증을 수행한다. 그러나 표준은 인증에 필요한 메시지의 수가 대체적으로 많은 편이며 PISIM의 분실과 에러가 발생했을 경우에는 사용자는 무선인터넷 서비스를 사용할 수 없게 된다. 따라서 본 논문에서는 ACR과 PSS 간에 키 동의 프로토콜을 수행하여 PSS를 인증한다. 이때 PSS의 계산량을 지원하기 위한 PSD(Power Support Device)가 키 동의 프로토콜에 참여하게 된다. 이렇게 생성된 키는 ACR과 안전한 통신 세션을 맺고 있는 KAS(Key Authentication Server)에 PSS의 식별자와 키 정보를 암호화에서 저장한다. 끝으로 제안된 프로토콜의 안전성과 효율성을 분석한다.

  • PDF

A Portable IoT-cloud ECG Monitoring System for Healthcare

  • Qtaish, Amjad;Al-Shrouf, Anwar
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.1
    • /
    • pp.269-275
    • /
    • 2022
  • Public healthcare has recently become an issue of great importance due to the exponential growth in the human population, the increase in medical expenses, and the COVID-19 pandemic. Speed is one of the crucial factors in saving life, particularly in case of heart attack. Therefore, a healthcare device is needed to continuously monitor and follow up heart health conditions remotely without the need for the patient to attend a medical center. Therefore, this paper proposes a portable electrocardiogram (ECG) monitoring system to improve healthcare for heart attack patients in both home and ambulance settings. The proposed system receives the ECG signals of the patient and sends the ECG values to a MySQL database on the IoT-cloud via Wi-Fi. The signals are displayed as an ECG data chart on a webpage that can be accessed by the patient's doctor based on the HTTP protocol that is employed in the IoT-cloud. The proposed system detects the ECG data of the patient to calculate the total number of heartbeats, number of normal heartbeats, and the number of abnormal heartbeats, which can help the doctor to evaluate the health status of the patient and decide on a suitable medical intervention. This system therefore has the potential to save time and life, but also cost. This paper highlights the five main advantages of the proposed ECG monitoring system and makes some recommendations to develop the system further.

Design and Implementation of 150W Portable Fuel Cell Power Pack (150W급 휴대용 연료전지 Power Pack 설계 및 제작)

  • Woo, Dong-Gyun;Joo, Dong-Myoung;Kim, Yun-Sung;Oh, Jae-Gi;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.553-561
    • /
    • 2012
  • Existing energy sources convert chemical energy into mechanical energy, while fuel cell directly generates electricity through an electrochemical reaction between hydrogen and oxygen. Therefore, it has a lot of strong points such as high efficiency, zero emission, and etc. In addition, with the development of hydrogen preservation technique, some companies have been researching and releasing portable fuel cell power packs for specific applications like military equipment, automobile, and so on. However, there are some drawbacks to the fuel cell, high cost and slow dynamic response. In order to compensate these weak points, auxiliary energy storages could be applied to the fuel cell system. In this paper, the optimum structure for a 150W portable fuel cell power pack with a battery pack is selected considering the specification of the system, and the design process of main parts is described in detail. Here, main objectives are compact size, simple control, high efficiency, and low cost. Then, an automatic mode change algorithm, which converts the operating mode depending on the states of fuel cell stack, battery pack, and load, is introduced. Finally, performance of the designed prototype using the automatic mode change control is verified through experiments.

An implementation of portable gamma ray detection platform using Cortex-A8 (Cortex-A8을 이용한 휴대용 감마선 검출 플랫폼 구현)

  • Seo, Jae-Gil;Lee, Yoon-Ho;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.1028-1033
    • /
    • 2013
  • As safety and security systems of shipping logistics are reinforced all over the world, ubiquitous technology-based core technology for safety and security is developing to build the system of logistics security. It is feared that the logistics security system of Korea has a possibility to technically depend on developed countries in the futures. Because the essential skills and equipment to retain security of logistics are not developed. It is urgent to introduce a logistics security system that fully integrates the entire logistics segment in the future. Thus, the necessity of developing the portable radiation detector which can detect gamma-ray nuclide is increasing for reinforcing safety and security systems. In this paper, a research suggests the implementation of portable radiation detector platform using Cortex-A8.

Development of a Portable Digital Electrocardiograph(ECG) measurable with Gel-less Metal Electrodes (젤리스 금속 전극으로 측정가능한 휴대용 디지털 심전도계의 개발)

  • Nam, Young-Jin;Park, Kwang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1903-1907
    • /
    • 2013
  • Heart condition should be observed for long periods of time because it does not appear abnormal all the time. However, there are many difficulties checking our health for a long time due to its size, operation of equipment, and cost. To solve these problems, an electrocardiograms(ECG), specially interfacing three gel-less metal electrodes for low cost portable applications, is designed and implemented. Gel-less metal electrodes are used for ECG monitoring system instead of gel-type electrodes that can cause skin rashes and itching problem. The whole ECG system consists of two parts-analog and digital circuits. The analog measurement circuit that has a 18*25mm size is made up of op-amps maintaining a sufficiently high common-mode noise rejection and passive elements of SMD type. Analog heart signal is converted to digital stream suitable for display on a TFT-LCD by an 8-bit microcontroller. The size of the completed ECG system is 25*80*50mm and its weighing is about 150g, which is small enough to be easily used. Therefore, the implemented ECG system can be used as a portable one.

A Study on portable voice recording prevention device (휴대용 음성 녹음 방지 장치 연구)

  • Kim, Hee-Chul
    • Journal of Digital Convergence
    • /
    • v.19 no.7
    • /
    • pp.209-215
    • /
    • 2021
  • This study is a system development for voice information protection equipment in major meetings and places requiring security. Security performance and stability were secured with information leakage prevention technology through generation of false noise and ultrasonic waves. The cutoff frequency band for blocking the leakage of voice information, which has strong straightness due to the nature of the radio wave to the recording prevention module, blocks the wideband frequency of 20~20,000Hz, and the deception jamming technology is applied to block the leakage of voice information, greatly improving the security. To solve this problem, we developed a system that blocks the recording of a portable smartphone using a battery, and made the installation of a separate device smaller and lighter so that customers do not recognize it. In addition, it is necessary to continuously study measures and countermeasures for efficiently using the output of the anti-recording speaker for long-distance recording prevention.

Ergonomic Evaluation of Young Agricultural Operators Using Handle Equipment Through Electromyography and Vibrations Analysis Between the Fingers

  • Federico Roggio;Ermanno Vitale;Veronica Filetti;Venerando Rapisarda;Giuseppe Musumeci;Elio Romano
    • Safety and Health at Work
    • /
    • v.13 no.4
    • /
    • pp.440-447
    • /
    • 2022
  • Background: Agricultural handle equipment is present on all production areas' farms. They are handy and portable; however, excessive use can lead to acute traumas or accidental injuries. Repetitive movements, awkward postures, and hand-arm vibrations predispose them to pain and work-related musculoskeletal disorders. The purpose of this study was to observe the interaction of handle equipment in terms of electromyographic activity and analyze the postural work-related alterations. Materials and methods: Twenty male agricultural operators, mean age 24±1.54 years, underwent the electromyographic analysis testing their muscular activities with a brushcutter, electric saw, and hedge trimmer in four different test conditions. Results: The brushcutter proved to be the agricultural handle equipment with the higher mean frequency (3.37±0.38 Hz) and root mean square (5.25±1.24 ms-2). Furthermore, the digital postural analysis showed a general asymmetry of the main arm and the respective side of the trunk. The head resulted right inclined in the anterior frontal plane by 5.7°±1.2°; the right scapula lower than the left in the posterior frontal plane (8.5°±1.8°), and a working trunk inclination of 34.15°±5.7°. Conclusions: Vibrations of handle equipment and awkward working postures represent a risk for agricultural operators. Preventive measures are required to avoid young operators from experiencing musculoskeletal disorders all lifelong.

Implementation of a portable pulse oximeter for SpO2 using Compact Flash Interface (컴팩트 플래쉬 방식의 휴대용 산소포화도 측정 시스템 구현)

  • Lee, Han;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.678-681
    • /
    • 2003
  • In this paper, we aims to develop a microcontroll er-based portable pulse oximeter using Compact Flash Interface. First, portable pulse oxineter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of SpO$_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patients condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO$_2$ modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact flash interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF