• 제목/요약/키워드: Port fire

검색결과 85건 처리시간 0.025초

도로터널 화재안전기준 기반 항만 지역 도로터널 화재 안전성 분석 (Evaluation of Fire Safety for Road Tunnels in Port Area based on Fire Safety Guidelines)

  • 하예진;전준호
    • 융복합기술연구소 논문집
    • /
    • 제11권1호
    • /
    • pp.25-28
    • /
    • 2021
  • Recently, the fire safety of road tunnels has been important issues in South Korea. However, proper fire safety regulations has not made for road tunnels. Due to geographical challenges in South Korea, road tunnels should be constructed to secure stable traffic flows. In the Guidelines for Installing and Managing Disaster Prevention Facilities of Road Tunnels (NFSC 603), main target vehicles are passenger cars. This guidelines cannot support big fires from larger vehicles such as cargo, oil trucks. In this study, fire safety for a road tunnel in port area was analyzed with fire dynamics theory under cargo truck fire scenario. Sujunsan road tunnel in Busan city was chosen as a target tunnel, which links between Busan port and highways to increase cargo shipping. The results show the limitations of present guidelines (NFSC 603) for road tunnel from large fire situations.

Long Jet Monitor의 소화수 분사 거리에 대한 유동 해석적 연구 (A Study of Computational Fluid Dynamics Analysis for the Water Spray Distance of Long Jet Monitor)

  • 조재상
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.907-913
    • /
    • 2023
  • Currently, the sprinkler method is widely used as an initial suppression method in existing firefighting systems. However, this method can cause significant damage to both equipment and facilities in the hydration area. To minimize this damage, fire extinguishing monitors are being developed that can spray fire extinguishing water directly at the point of fire. These monitors are installed on the top floor of the ship, such as the Living Quarter and Ventilation System. While conventional fire extinguishing monitors focus on lightweight research with a short spray port and require a spray distance of about 40 to 45m, recent developments necessitate a longer spray port, similar to a water cannon, requiring a spray distance of about 70 to 75m. This study aims to predict the injection distance of both the existing ship-installed fire extinguisher and the long spray port fire extinguisher through hydrodynamic computer analysis, and to determine whether the injection distance has increased.

일반 소방호스와 꼬임방지 소방호스의 꼬임 횟수에 따른 방수시간 분석 (Analysis of Waterproof Time by Number of Twists between Ordinary Fire Hose and Anti-twist Fire Hose)

  • 홍석환;김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제23권4호
    • /
    • pp.55-60
    • /
    • 2021
  • This study is to check waterproof by number of twists of fire hose and measure the first waterproof time to analyze the relationship between twists of fire hose and first waterproof time and waterproof by position of twists so as to suggest the efficient plan to prevent twists of fire hose. Ordinary fire hose did not make waterproof in case that position of twists was near the nozzle with twists 5 times or more, while anti-twist fire hose had no problem for waterproof only with delayed time. Like ordinary fire hose, anti-twist fire hose also showed the tendency to increase the waterproof time in proportion to the number of twists. In case that the position of twists was near waterproof port even with 10 times of twists in anti-twist fire hose, the first waterproof time was increase by 0.63 seconds on average without any problem for waterproof, which was somewhat faster than that in ordinary fire hose. With respect to the position of twists, waterproof of anti-twist fire hose was affected more as the number of twists was increased more near the nozzle rather than near the waterproof port, like ordinary fire hose. In summary, anti-twist fire hose equipped with anti-twist tool at the middle connection port and the nozzle showed a good waterproof performance with delayed waterproof time regardless of number of twists, as a solution for the twist problem of ordinary fire hose.

매연포집필터 과열로 발생한 디젤승용차화재 원인의 분석 (Analysis of a Car Fire Case Caused by the Overheating of a Diesel Particulate Filter)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제31권1호
    • /
    • pp.89-97
    • /
    • 2017
  • 본 연구에서는 서비스센터에서 정비를 받고 출고한 날로부터 5일 후 터널 주행 중에 발생한 디젤승용차 화재 사례를 조사분석하였다. 조사분석한 결과, 배기구 내부에 흰색 이물질이 다량 부착되어 있었고, 배기관의 중간에 설치된 diesel particulate filter (DPF) 위쪽의 차열재가 용융 및 소실되어 있었고, DPF 위쪽의 차실 내부 금속재 바닥이 천공되어 금속재 바닥 위에 놓인 고무매트가 연소된 케이스이었다. 그리고 DPF 앞쪽의 배기관에는 과열흔적이 없고 DPF부터 배기구까지의 배기관에 과열흔적이 있는 특이점이 있었다. 이러한 특이점들은 DPF가 과열되고 DPF에서 발화된 경우에만 나타나므로 이 승용차화재는 DPF 내부 과열에 의해 발생한 것으로 분석할 수 있었다. 그리고 이 승용차화재조사를 통해 디젤승용차 화재원인조사 과정에서 배기구 내부에서 흰색 이물질이 확인되는 경우에는 DPF를 분리하여 DPF 내부의 손상을 조사하여 화재원인을 판정하여야 함을 알 수 있었다.

Concept Design of Fire Safety Module for SV20 Service in the Korean e-Navigation System

  • Kim, Byeol;Moon, Serng-Bae;Hwang, Kwang-Il
    • 한국항해항만학회지
    • /
    • 제42권5호
    • /
    • pp.323-330
    • /
    • 2018
  • The Korean e-Navigation system is a Korean approach to correspond with implementation of IMO e-Navigation. It provides five services, among them SV20 service, a ship remote monitoring system that collects and processes sensor information related to fire, navigation, and seakeeping performance safety. The system also detects abnormal conditions such as fires, capsizing, sinking, navigation equipment failure during navigation, and calculates the safety index and determines the emergency level. According to emergency level, it provides appropriate emergency response guidance for the onboard operator. The fire safety module is composed of three sub-modules; each module is the safety index sub-module, the emergency level determination sub-module and emergency response guidance sub-module. In this study, operational concept of the fire safety module in SV20 service is explained, and fire safety assessment factors are estimated, to calculate the fire safety index. Fire assessment factors included 'Fire detector position factor,' 'Smoke diffusion rate factor,' and 'Fire-fighting facilities factor.'

도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구 (Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel)

  • 유지오;김진수;이동호
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.68-74
    • /
    • 2016
  • 도로터널에 적용하는 반횡류환기방식은 터널의 전연장에 걸쳐서 단위길이당 풍량이 균일하게 될 수 있도록 포트의 개도 조정이 필수적이다. 그러나 현재 국내에서 운영중인 터널의 경우에는 설계시 이에 대한 고려가 적절히 이루어지지 못하고 있는 실정이다. 이에 본 연구에서는 개도계산을 위한 프로그램을 개발하고 반횡류환기방식의 터널에서 포트의 운영방안을 제시하였다. 연구결과, 포트의 개도는 급기방식의 덕트에서는 환기소측에서 덕트의 말단(bulk head)쪽으로 갈수록 증가하였다가 감소하는 경향을 가지며, 최소 개도는 56% 정도로 나타나고 있다. 또한 배기방식에서는 환기소측이 15% 정도로 가장 작고 bulk head 쪽으로 갈수록 증가하는 경향을 보이고 있다. 화재시 300 m 구간의 배연풍량을 검토한 결과, 포트사이즈를 조정하지 않는 경우와 급기방식으로 포트사이즈을 조정한 경우에는 터널중앙부의 배연량이 각각 8.1%와 12.5%로 터널중앙부의 배연풍량이 저조한 것으로 나타났다. 따라서 반횡류환기방식의 터널에서는 평상시 환기효율이 저하하더라도 배연시 균일한 풍량을 얻을 수 있도록 포트의 개도를 설정하여 운영하는 것이 반드시 필요한 것으로 판단된다.

항구도시 근대 도시공간 형성에 관한 연구 - 요코하마시 가로 및 운하의 변용을 중심으로 - (A Study on the Formation of Modern Urban Space in Harbor City - Focusing on Transformation of the Urban Street and Canal Space in Yokohama Japan -)

  • 홍지완;김준;유재우
    • 대한건축학회논문집:계획계
    • /
    • 제34권4호
    • /
    • pp.133-140
    • /
    • 2018
  • This study is change of the street space of the port city of Yokohama and the transformation process of the canal. modern port city Yokohama is a region that was responsible for the development of East-West maritime transport routes in Japan in the 17th century and the inland transportation through fishing villages and ports. it has also grown rapidly as a regional port and new port. In particular, through the revitalization of trade between foreign settlements and Japanese residents in the port area, the existing fishing area became a modern port city space. Yokohama went through the following process and grew into a modern port city. The construction of the port harbor and the maintenance of existing logistics functions, the formation of the central horizontal axis through maintenance of the fishing village, the construction of the logistics movement route to the inland area through the construction of the canal, the expansion of the horizon for fire prevention and fire restoration, The formation of a new settlement space according to the movement, the transformation of the existing religious axis by the combination of the elaboration and the introduction of modern transportation, and the spatial connection between the inland cities.

End-Fire 방사특성을 가지는 2.4GHz ISM 밴드용 Open End 슬롯 안테나의 설계

  • 조윤기;권기환;윤정호;임성균;이영순
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2010년도 춘계학술대회
    • /
    • pp.154-155
    • /
    • 2010
  • 본 논문에서는 end-fire 방사패턴 특성을 가지는 2.4GHz ISM 밴드용 소형 open-end slot 안테나를 설계하였다. 안테나 설계 공간은 $23mm{\times}15mm$의 좁은 영역으로 한정된 공간 내에 안테나를 설계하기 위하여 한번의 Bent된 slot을 도입하였고, End-Fire 방사특성을 내기위해 안테나 수평면상의 위쪽 방향으로 slot을 open시킨 구조이다. Bent된 slot을 이용해 전체 slot의 길이를 변화시키지 않고 주파수의 조절이 가능하고, Feeding Line의 길이와 폭을 조절하여 보다 광대역의 특성을 얻을 수 있었다. 제작된 안테나의 공진 주파수는 2.46GHz이고 대역폭은 2.4GHz~2.61GHz 까지 약 210MHz(VSWR<2) 이다. 방사패턴은 동작 주파수 내에서 slot이 open된 방향으로 end-fire특성을 가지고, 안테나의 이득과 효율은 각 각 1dBi, 70% 이상의 성능을 가진다. 설계 결과의 검증을 위해 모의실험 결과와 측정 결과를 비교하여 제시하였다.

  • PDF

울산항 위험물 환적부두 지정을 위한 폭발 위험성 평가에 관한 연구 (A Study of Explosion Risk Assessment for Designation of Dangerous Goods Transshipment Pier at Ulsan Port)

  • 강민균;이윤석;안영중
    • 한국항해항만학회지
    • /
    • 제45권3호
    • /
    • pp.109-116
    • /
    • 2021
  • 울산항 부두에 이중 접안하여 환적작업 중이던 케미컬 탱커선 폭발로 주변 선박화재 등 울산항 내에서 큰 피해가 발생하였다. 유사 사고의 재발을 방지하기 위한 후속 조치로 '항만 내 위험물 안전관리 종합대책'이 수립되었으며 사고 발생 시에 폭발 위험성과 항내 주요 시설에 대한 영향 등을 고려한 위험물 환적부두의 지정이 요구된다. 본 연구는 폭발 위험성 기반의 환적부두 제시를 위하여 울산항 주요 환적화물 대상의 Fire & Explosion Index 평가를 실시하였다. 스티렌모노머와 벤젠의 Fire & Explosion Index 평가결과 심각한 폭발 위험성을 확인하였고, 평가결과를 기준으로 노출반경을 산출 하였다. 노출반경 결과를 기반으로 주요 부두별 위험범위를 산정하였으며, 항만시설, 주변 위험시설 및 거주시설을 고려한 환적가능 부두 후보지로 12개 부두를 제시하였다. 본 연구는 위험반경만을 고려하였기 때문에 향후 실질적인 위험물 환적 부두의 지정 시에는 해상교통안전성, 부두 및 계류시설, 안전설비 및 비상대응을 위한 접근성 등을 종합적으로 고려하여 결정하여야 할 것이다.