• Title/Summary/Keyword: Porous media model

Search Result 211, Processing Time 0.024 seconds

Prediction of the effective thermal conductivity of microsphere insulation

  • Jin, Lingxue;Park, Jiho;Lee, Cheonkyu;Seo, Mansu;Jeong, Sangkwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.36-41
    • /
    • 2014
  • Since glass microsphere has high crush strength, low density and small particle size, it becomes alternative thermal insulation material for cryogenic systems, such as storage and transportation tank for cryogenic fluids. Although many experiments have been performed to verify the effective thermal conductivity of microsphere, prediction by calculation is still inaccurate due to the complicated geometries, including wide range of powder diameter distribution and different pore sizes. The accurate effective thermal conductivity model for microsphere is discussed in this paper. There are four mechanisms which contribute to the heat transfer of the evacuated powder: gaseous conduction ($k_g$), solid conduction ($k_s$), radiation ($k_r$) and thermal contact ($k_c$). Among these components, $k_g$ and $k_s$ were calculated by Zehner and Schlunder model (1970). Other component values for $k_c$ and $k_r$, which were obtained from experimental data under high vacuum conditions were added. In this research paper, the geometry of microsphere was simplified as a homogeneous solid sphere. The calculation results were compared with previous experimental data by R. Wawryk (1988), H. S. Kim (2010) and the experiment of this paper to show good agreement within error of 46%, 4.6% and 17 % for each result.

A study on modeling of boiling heat transfer in core debris bed of SFR

  • Venkateswarlu S.;Hemanth Rao E.;Prasad Reddy G.V.;Sanjay Kumar Das;Ponraju D.;Venkatraman B.
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3864-3871
    • /
    • 2024
  • In case of a hypothetical severe accident in a Sodium-cooled Fast Reactor (SFR), coolability of the debris bed in the post-accident phase plays a vital role in mitigating the accident and ensuring the structural integrity of the reactor vessel. Few numerical studies are reported in literature, in which the boiling heat transfer in debris bed is expressed as equivalent heat conduction using similarity law between heat conduction and two-phase heat transfer. However, these studies assumed steady state mass conservation for the boiling zone and neglected the gravity force. Hence, a detailed study has been carried out for various particle sizes and porosities of SFR debris to investigate the influence of above considerations. The effect of gravity on debris bed coolability is studied using steady state model of Lipinski, which showed that gravity has a non-negligible effect, for particle size of 0.3 mm and porosity of 0.5. However, the gravitation force was found to have a negligible effect in dryout heat flux estimation for the bottom cooled configuration. A transient numerical model is developed for simulating the boiling phenomena in debris beds and validated with the published experimental results. The assumption of steady state mass conservation is verified by carrying out transient analysis, which indicated early prediction of the dryout inception. For time dependent heat generation case, the unsteady mass conservation predicted higher DHF compared to constant heat generation.

Numerical Simulation of Immiscible Water-Gas Simultaneous Flow in the absence of Capillary Force in a Single Fracture (단일절리에서 모세관압을 고려하지 않은 불혼합성 물과 가스의 동시거동 해석)

  • 한일영;서일원
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.69-81
    • /
    • 2001
  • The constitutive relation among capillary pressure, saturation and relative permeability should be predetermined in order to simulate immiscible water-gas flow in porous media. The relation between saturation and relative permeability becomes more important when the capillary force can be disregarded and viscous friction force governs the flow. In this study, a 2-dimensional finite difference numerical model was developed, in which the variation of viscosity with pressure and that of relative permeability with water saturation can be treated. Seven cases of parallel plate tests were performed in order to obtain the characteristic equation of relative permeability which would be used in. the developed numerical model. It was not possible, however, to match the curves of relative permeability from the plate tests with the existing emperical models. Consequently a logistic equation was proposed as a new emperical model. As this model was composed of the parameter involving aperture size, any aperture size of fracture can be applied to the model. For the purpose of verification, the characteristic equation of relative permeability was applied to the developed numerical model and the computed results were compared with those of plate test. As a result of application of numerical model, in order to check the field applicability, to single fracture surrounding an underground storage cavern, the simultaneous flow of water and propane gas was able to be simulated properly by the model.

  • PDF

Three-Phase Eulerian Computational Fluid Dynamics (CFD) of Air-Water-Oil Separator with Coalescer (유적 합체기가 포함된 공기-물-기름 분리 공정에 대한 3상 Eulerian 전산유체역학)

  • Lim, Young-Il;Le, Thuy T.;Park, Chi-Kyun;Lee, Byung-Don;Kim, Byung-Gook;Lim, Dong-Ha
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.201-213
    • /
    • 2017
  • Water is removed from crude oil containing water by using oil separator. This study aims to develop a three-dimensional (3D) Eulerian computational fluid dynamics (CFD) model to predict the separation efficiency of air-water-oil separator. In the incompressible, isothermal and unsteady-state CFD model, air is defined as continuous phase, and water and oil are given as dispersed phase. The momentum equation includes the drag force, lift force and resistance force of porous media. The standard k-${\varepsilon}$ model is used for turbulence flow. The exit pressures of water and oil play an important role in determining the liquid level of the oil separator. The exit pressures were identified to be 6.3 kPa and 5.1 kPa for water and oil, respectively, to keep a liquid level of 25 cm at a normal operating condition. The time evolution of volume fractions of air, water and oil was investigated. The settling velocities of water and oil along the longitudinal separator distance were analyzed, when the oil separator reached a steady-state. The oil separation efficiency obtained from the CFD model was 99.85%, which agreed well with experimental data. The relatively simple CFD model can be used for the modification of oil separator structure and finding optimal operating conditions.

Numerical Study on the Phenomenon of Spontaneous Ignition of Coal Stockpile (저탄장 자연발화 현상의 수치해석적 연구)

  • Kim, Chul-Jin;Park, I-Sun;Sohn, Chae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.721-727
    • /
    • 2010
  • The spontaneous ignition of coal stockpile causes serious safety and economic problems. Such spontaneous ignition occurs in coal stockpile when the rate of heat released by the oxidation of coal is greater than the rate of heat lost to the surroundings. In this study, a two-dimensional unsteady model is adopted for studying spontaneous ignition and the numerical results are compared with experimental results. The numerical results are in a good agreement with the experimental ones. Depending on the porosity, the internal maximum temperature, pressure, and oxygen mass fraction during spontaneous ignition are investigated. On the basis of the numerical results, the transient temperature variations for several shapes of coal stockpiles are analyzed. Further, the physical mechanisms of hot-spot formation and spontaneous ignition are analyzed.

Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct (안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석)

  • Yoo, Geun-Jong;Choi, Hoon-Ki;Choi, Kee-Lim
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.923-932
    • /
    • 2011
  • Because of the instability of a flow pattern in the inlet transition square duct (hereinafter referred to as "transition duct") of a heat recovery steam generator (hereinafter referred to as "HRSG") in a combined cycle power plant, the Reynolds number in the first row of a tube bank is differs sharply from that in the sectional area of the transition duct. This causes differences in the heat flux in each tube in the tube bank. The computational fluid dynamics (CFD) predictions provide three-dimensional results for velocity, temperature, and other flow parameters over the entire domain of the duct and HRSG. A renormalization group theory (RNG) based k-${\epsilon}$�� turbulent model is used for obtaining the results cited in this study. A porous media option is used for modeling the tube banks and the number of transfer units method is used for determining the heat transfer characteristics. This study describes a comparison between the numerical simulation results and actual design output.

A Study on the Flow Characteristics according to the Change of Structure in Filtration Using the Numerical Model (수치모형을 이용한 여과기 내 구조 변경에 따른 유동특성 연구)

  • Kim, Taewon;Song, Sooho;Choi, Changhyung;Park, Youngjin;Kim, Jiho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.285-285
    • /
    • 2017
  • 최근 전 세계적으로 심각해지는 물 부족 현상과 수질오염으로 대량의 원수를 빠른 시간 내에 여과하기 위한 여과장치의 개발 및 효율성 향상을 위한 연구의 필요성이 증가되고 있다. 특히 여과필터의 내부구조에 의해 유동이 편중되는 현상이 발생하면 여과효율 및 여과필터 유지관리에 문제가 발생되기 때문에 최적의 여과필터를 설계하는 것이 중요하다. 이에 본 연구에서는 수리모형실험으로 검토하기에 어려움이 있는 여과기 내부구조에 대한 유동특성을 수치해석을 이용하여 검토하였다. 수치해석은 유한요소법 기반의 수치모형으로 여과기 내부를 상세하게 모의할 수 없기 때문에 유한체적법 기반인 ANSYS CFX 모형을 이용하였다. 여과기 내 여과필터는 두께 2.0 mm, 공극율 25%로 가정하고 다공성 기법(porous media)을 적용하였다. 검토를 위한 경계조건은 유입부에 목표 취수량, 유출부에 대기압 조건을 적용하였으며, 여과기에 비해 매우 작게 구성된 여과필터 내부의 유동특성을 검토하기 위해 여과기는 최소 3.0 mm, 여과필터는 1.0 mm의 격자를 적용하였다. 현재 실제 여과시설에 적용되고 있는 여과기 제품 형상을 기준으로 여과기 내부 흐름공간의 크기 및 각도 조정에 따른 유동특성을 검토하여 여과효율을 비교하였으며 통과유량, 유속, 유속벡터 등을 검토하여 균등한 유량과 유속이 발생되는 최적의 여과장치 구조를 도출하였다. 본 연구에서 여과기 내부 구조 변경에 따른 유동특성 검토를 통해 도출된 최적의 여과기 내부크기 및 각도에 대한 설계인자는 여과기 내 여과필터의 효율을 증가시킬 뿐만 아니라 내구성 증진에 도움이 될 것으로 예상된다.

  • PDF

Analysis of the Deformed Unit Cell by Clamping Force Through the FEM and CFD Interaction (FEM과 CFD 연동을 통한 스택 체결 시 압력에 의해 변형된 단위 전지 해석)

  • YOO, BIN;LIM, KISUNG;JU, HYUNCHUL
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.4
    • /
    • pp.228-235
    • /
    • 2021
  • Polymer electrolyte membrane fuel cells (PEMFC) are currently being used in various transport applications such as drones, unmanned aerial vehicles, and automobiles. The power required is different according to the type of use, purpose, and the conditions adjusted using a cell stack. The fuel cell stack is compressed to reduce the size and prevent fuel leakage. The unit cells that make up the cell stack are subjected to compression by clamping force, which makes geometrical changes in the porous media and it impacts on cell performance. In this study, finite elements method (FEM) and computational fluid dynamics (CFD) analysis for the deformed unit cell considering the effects of clamping force is performed. First, structural analysis using the FEM technique over the deformed gas diffusion layer (GDL) considering compression is carried out, and the resulting porosity changed in the GDL is calculated. The PEMFC model is then verified by a three-dimensional, two-phase fuel cell simulation applying the physical properties and geometry obtained before and after compression. The detailed simulation results showed different concentration distributions of fuel between the original and deformed geometry, resulting in the difference in the distribution of current density is represented at compressed GDL region with low oxygen concentration.

A Review on Measurement Techniques and Constitutive Models of Suction in Unsaturated Bentonite Buffer (불포화 벤토나이트 완충재의 수분흡입력 측정기술 및 구성모델 고찰)

  • Lee, Jae Owan;Yoon, Seok;Kim, Geon Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.329-338
    • /
    • 2019
  • Suction of unsaturated bentonite buffers is a very important input parameter for hydro-mechanical performance assessment and design of an engineered barrier system. This study analyzed suction measurement techniques and constitutive models of unsaturated porous media reported in the literature, and suggested suction measurement techniques and constitutive models suitable for bentonite buffer in an HLW repository. The literature review showed the suction of bentonite buffer to be much higher than that of soil, as measured by total suction including matric suction and osmotic suction. The measurement methods (RH-Cell, RH-Cell/Sensor) using a relative humidity sensor were suitable for suction measurement of the bentonite buffer; the RH-Cell /Sensor method was more preferred in consideration of the temperature change due to radioactive decay heat and measurement time. Various water retention models of bentonite buffers have been proposed through experiments, but the van Genuchten model is mainly used as a constitutive model of hydro-mechanical performance assessment of unsaturated buffers. The water characteristic curve of bentonite buffers showed different tendencies according to bentonite type, dry density, temperature, salinity, sample state and hysteresis. Selection of water retention models and determination of model input parameters should consider the effects of these controlling factors so as to improve overall reliability.

Numerical Modeling of Flow Characteristics within the Hyporheic Zones in a Pool-riffle Sequences (여울-소 구조에서 지표수-지하수 혼합대의 흐름 특성 분석에 관한 수치모의 연구)

  • Lee, Du-Han;Kim, Young-Joo;Lee, Sam-Hee
    • Journal of Wetlands Research
    • /
    • v.14 no.1
    • /
    • pp.75-87
    • /
    • 2012
  • Hyporheic zone is a region beneath and alongside a stream, river, or lake bed, where there is mixing of shallow groundwater and surfacewater. Hyporheic exchange controls a variety of physical, biogeochemical and thermal processes, and provides unique ecotones in a aquatic ecosystem. Field and experimental observations, and modeling studies indicate that hyporheic exchange is mainly in response to pressure gradients driven by the geomorphological features of stream beds. In the reach scale of a stream, pool-riffle structures dominate the exchange patterns. Flow over a pool-riffle sequence develops recirculation zones and stagnation points, and this flow structures make irregular pressure gradient which is driving force of the hyporheic exchange. In this study, 3 D hydro-dynamic model solves the Reynolds-averaged Navier-Stokes equations for the surface water and Darcy's Law and the continuity equation for ground water. The two sets of equations are coupled via the pressure distribution along the interface. Simulation results show that recirculation zones and stagnation points in the pool-riffle structures dominantly control the upwelling and downwelling patterns. With decrease of recirculation zones, length of donwelling zone formed in front of riffles is reduced and position of maximum downwelling point moves downward. The numerical simulation could successfully predict the behavior of hyporheic exchange and contribute the field study, river management and restoration.