• Title/Summary/Keyword: Porcelain materials

Search Result 304, Processing Time 0.025 seconds

An Experimental Study on the Abrasion Tests as a Result of using Materials of Full Denture Occlusal Surface (총의치교합면의 사용재료에 따른 마모도 측정에 관한 실험적 연구)

  • Cha, Sung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.19-26
    • /
    • 1983
  • I got a conclusion as a result of that in case of constructing a full denture using acrylic resin teeth, porcelain teeth, and forming posterior occlusal surface of the artificial teeth by Type III Gold and Nickel crome alloy thus construdting a full denture and therefore comparing the above case with abrasion of Natural teeth. The result were as follows : 1. The abrasion of Natural teeth and the abrasion of full denture constructed by Type III gold has a close resemblance. 2. The one that has the hightest degree of abrasion is full denture that's using, with acrylic resin teeth, maxillary and mandibular And the lowest abrasion is natural teeth-natural teeth. 3. In case of single denture, that's opposing to natural teeth, the one that has the hightest degree of abrasion is a full denture that's using Acrylic resin teeth and the lowest abrasion is a full denture that's forming occlusal surface by Type III gold. 4. The single denture, which is opposing to type III gold teeth, was abraded above everything by full denture which is constructed by porcelain teeth. 5. In the same teeth, the abrasion of mandibular teeth was greater than that of mandibular teeth was greater than that of maxillary teeth. 6. The abrasion degree of Acrylic resin teeth has no direct mutual connection with material hardness which is opposing to.

  • PDF

Shade Matching Identification of in Vivo Natural Teeth and Porcelain-Fused-to-Metal Crowns (자연치와 도재관에 대한 색조선택의 동일성)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.35-48
    • /
    • 2007
  • The purpose of this study was to evaluate shade selection using conventional visual assessment in vivo natural teeth and porcelain-fused-to-metal (PFM) crown. Maxillary central incisors, lateral incisors and canines of one hundred twenty four college women were used as vivo natural teeth. Fifty one PFM crown for maxillary central incisor fabricated by dental laboratory were used as experimental materials. Using Vitapan Classical Shade Guides, shade selection of natural teeth was measured by each college woman and shade selection of PFM crown was measured by three ceramists with more than ten years career. Both natural teeth and PFM crown shade selection were measured through Shade Eye-Ex. From the shade selection comparing, following results were obtained. The results were as follows: 1. The shade matching identification of natural teeth between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 27.4% in maxillary central incisor, 13.7% in lateral incisor and 18.5% in canine. 2. Among the shade selection of PFM crown by three ceramists, the shade evaluation of three ceramists were same only in ten cases. In twenty case, those of two ceramists were same. 3. The shade matching identification of PFM crown between the shade selection using Vitapan Classical Shade Guides and the shade selection using Shade Eye-Ex was 38.6% in average. These results suggest that the shade selection using conventional visual assessment should be dealt with care in clinic and need a credible method for shade matching color.

  • PDF

The effect of various polishing systems on surface roughness and phase transformation of monolithic zirconia

  • Caglar, Ipek;Ates, Sabit Melih;Duymus, Zeynep Yesil
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.132-137
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate and compare three polishing systems on the surface roughness and phase transformation of monolithic zirconia. MATERIALS AND METHODS. 100 disk shaped specimens (10 mm diameter, 3 mm thickness) were fabricated from monolithic zirconia blocks. 20 specimens were left as a control group and remaining specimens were grinded by diamond bur to simulate the occlusal adjustments. Grinded specimens were randomly divided into 4 groups: group G (no polishing), group M (Meisinger, zirconia polishing kit), group E (EVE Diacera, zirconia polishing kit), and group P (EVE Diapol, porcelain polishing kit). Surface roughness was measured with profilometer and surface topography was observed with SEM. XRD analysis was performed to investigate the phase transformation. Statistical analysis was performed with one-way ANOVA and Tukey's post hoc tests at a significance level of P=.05. RESULTS. All polishing groups showed a smoother surface than group G. Among 3 polishing systems, group M and group E exhibited a smoother surface than the group P. However, no significant differences were observed between group M and group E (P>.05). Grinding and polishing did not cause phase transformations in zirconia specimens. CONCLUSION. Zirconia polishing systems created a smoother surface on zirconia than the porcelain polishing system. Phase transformation did not occur during the polishing procedure.

The study on the color change according to zirconia core thickness, and build-up technique using spectrophotometer (Spectrophotometer를 이용한 지르코니아 코어의 두께 및 도재축성법에 따른 색조의 변화에 대한 연구)

  • Huh, Sung-Yoon;Kim, Jae-Hong;Son, Ho-Jung
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.313-321
    • /
    • 2011
  • Purpose: The purpose of this study was to compare color parameters of different fabrication method of Lava ceram powder, Lava DVS blocks, IPS e.max ceram and IPS e.max zirpress. Methods: The three available shades(A1, A2, A3.5) of Lava & Kavo zirconia blocks were examined. For each of three colors, three different thickness were tested, 5 times of measurement frequency. The measurements were made using a spectrophotometer equipped with an integrating sphere using the CIE $L^*$, $a^*$, $b^*$ colorimetric system. Results: Lava build-up group and Lava DVS group showed clinically perceived color difference, on the other hand IPS e.max build-up group and IPS e.max zirpress group did not show clinically perceived color difference to shade allowed on core. When the thickness of porcelain veneer increased from Lava and IPS e.max groups, color differences(${\Delta}E$) were decreased. Conclusion: All-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness

  • Tekin, Yadel Hazir;Hayran, Yeliz
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.283-290
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55℃/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey's HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 ㎛ even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.

A Study on SEM Observations of Low Temperature Degradation in Zirconia Dental Ceramics (저온열화에 따른 치과용 지르코니아의 전자현미경 관찰 연구)

  • Lee, Jung-Hwan;Joo, Kyu-Ji;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.15-23
    • /
    • 2011
  • Purpose: Thy yttria tetragonal zirconia polycrystalline(Y-TZP) is a good structural ceramic for dental restoration. But it have a problem that delamination of veneering ceramic from the Y-TZP core materials. The problem generally occur at the interface, thus this study was conducted to evaluate the interface of Y-TZP using scanning electron microscopy(SEM). Methods: To investigate this aspect, high-resolution SEM observations were made of polished and etched (HF content gel) cross-sections of the interface area. Dry and moist veneering porcelain powders were built up on the zirconia base. Results: The extent of this surface faceting is dependent upon the moisture content of the porcelain powder and the firing temperature. More moisture and higher final heating temperature accelerates the observed faceting of the Y-TZP grains at the interface to the veneering ceramic. Conclusion: These changes of the Y-TZP grains indicate that destabilization of the tetragonal phase of zirconia occurs at the interface during veneering with ceramic. It may result in a reduction of the stability of the zirconia and interface.

Tribological Behavior of Whiteware with Different Transparent Glazes

  • Heo, Sujeong;Kim, Soomin;Kim, Ungsoo;Pee, Jaehwan;Han, Yoonsoo;Kim, Seongwon;Lee, Sungmin;Kim, Hyungtae;Oh, Yoonsuk
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.3
    • /
    • pp.186-191
    • /
    • 2015
  • Tribological properties of whiteware with various transparent glazes, which have different composition and microstructure, were investigated. The wear resistance and friction behavior of the glazed whiteware are a very important aspect if the whiteware is used as tableware and for sanitation purposes. Generally, the wear property is influenced by the microstructure and surface morphology of the material. The whiteware specimens with two kinds of transparent glazes were fabricated by using the commercially available porcelain body. Furthermore, the commercial tableware, such as bone china, and traditional tableware were also examined as reference materials. All of the specimens showed that different pore structures might affect the mechanical and tribological properties. It seems that the wear resistance of whiteware is substantially related to the pore size and distribution of glaze rather than the hardness value of the specimen.

A Study on Properties of Porcelain Suspension Insulator for Transmission Line by a Change of Raw Materials (송전용 자기재 현수애자의 원료변화에 따른 특성 연구)

  • 최인혁;최장현;이동일;최연규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.390-395
    • /
    • 2004
  • In order to analyze the physical and chemical characteristics of home production porcelain insulators by change of the alumina addition amount, 360001bs ball socket type suspension insulators which were manufactured in 1989, 1995 and 2001 removed in transmission line and an experiment was performed. By the result, 8 wt.% alumina that influences the mechanical properties and arc resistance properties in case of insulators that were manufactured in 1989 was contained, and the relative density and the fracture toughness of insulators appeared by 94.2% and 1.4 ㎫$.$ $M^{\frac{1}{2}}$, respectively. However, 12 wt.% alumina was contained in case of insulators that were manufactured in 1995, and the relative density and the fracture toughness of insulators appeared preferably lower by 92% and 1.3㎫$.$ $M^{\frac{1}{2}}$, respectively. Amount of alumina was contained most by 17 wt.% in case of insulators that were manufactured in 2001. It was confirmed that the electrical and mechanical characteristics such as the relative density and the fracture toughness appeared excellently by 96% and 1.7㎫$.$ $m^{\frac{1}{2}}$, respectively.

Various Factors Influencing the Lifetime of Suspension-Type Porcelain Insulators for 154 kV Power Transmission Lines

  • Choi, In Hyuk;Park, Joon Young;Kim, Tae Gyun;Yoon, Yong Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.151-154
    • /
    • 2017
  • In this article, we investigated the various influencing factors that degraded the lifetime of suspension insulators in 154 kV transmission lines, and showed the possible solutions to avoid such breakdowns. With respect to achieve safety, reliability and aesthetical considerations, the characteristics of transmission and distribution network power cables should be improved. Suspension insulators are particularly important to study, as they have developed to be the main component of transmission lines due to their ability to withstand the electrical conductivity of high-voltage power transmission. Suspension insulators are mostly made from glass, rubber and ceramic material due to their high resistivity. In Korea, porcelain suspension insulators are typically used in the transmission line system, as they are cheaper and more flexible compared to other types of insulators. This is effective from preventing very high and steep lightening impulse voltages from causing the breakdown of suspension insulators used in power lines. Other influential factors affect the lifetime of suspension insulators that we studied include temperature, water moisture, contamination, mechanical vibration and electrical stress.

Repair bond strength of composite resin to zirconia restorations after different thermal cycles

  • Cinar, Serkan;Kirmali, Omer
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.297-304
    • /
    • 2019
  • PURPOSE. This in vitro study investigated the repair bond strength of the zirconia ceramic after different aging conditions. MATERIALS AND METHODS. In order to imitate the failure modes of veneered zirconia restorations, veneer ceramic, zirconia, and veneer ceramic-zirconia specimens were prepared and were divided into 4 subgroups as: control ($37^{\circ}C$ distilled water for 24 hours ) and 3000, 6000, 12000 thermal cycling groups (n=15). Then, specimens were bonded to composite resin using a porcelain repair kit according to the manufacturer recommendation. The repair bond strength (RBS) test was performed using a universal testing machine (0.5 mm/min). Failure types were analyzed under a stereomicroscope. Two-way ANOVA and Bonferroni test were used for statistical analysis. RESULTS. The RBS values of zirconia specimens were statistically significant and higher than veneer ceramic and veneer ceramic-zirconia specimens in control, 3000 and 6000 thermal cycling groups (P<.05). When 12000 thermal cycles were applied, the highest value was found in zirconia specimens but there was no statistically significant difference between veneer ceramic and veneer ceramic-zirconia specimens (P>.05). Veneer ceramic specimens exhibited cohesive failure types, zirconia specimens exhibited adhesive failure types, and veneer ceramic-zirconia specimens exhibited predominately mixed failure types. CONCLUSION. Thermal cycling can adversely affect RBS of composite resin binded to level of fractured zirconia ceramics.