• 제목/요약/키워드: Porcelain fracture

검색결과 109건 처리시간 0.028초

지르코니아와 포세린의 전단결합강도 (Shear Bond Strength Between Zirconia and Porcelain)

  • 김사학
    • 대한치과기공학회지
    • /
    • 제33권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: To examine the shear bond strengths of zirconia and veneering ceramic according to their surface processing. Methods: The test samples were divided into three groups: one without zirconia surface processing, one sandblasted, and one sandblasted then 3% etched. Then veneering ceramic was fired on all test samples, and their shear bond strengths were measured. Results: The test samples of the control group (Z1) showed the lowest shear bond strengths of $21.82{\pm}1.02$ MPa. The shear bond strengths of Z2 and Z3 ($28.25{\pm}0.72$ and $26.23{\pm}0.82$ MPa, respectively) were relatively higher than those of the control group. The fracture surface of the control group showed adhesive fractures while the test groups had relatively large numbers of cohesive fractures. Conclusion: The shear bond strength was high in the test groups with surface processing while the fracture surfaces showed compound fractures of adhesive and cohesive fractures.

The effect of zirconia framework design on the failure of all-ceramic crown under static loading

  • Urapepon, Somchai;Taenguthai, Pakamard
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.146-150
    • /
    • 2015
  • PURPOSE. This in vitro study aimed to compare the failure load and failure characteristics of two different zirconia framework designs of premolar crowns when subjected to static loading. MATERIALS AND METHODS. Two types of zirconia frameworks, conventional 0.5 mm even thickness framework design (EV) and 0.8 mm cutback of full contour crown anatomy design (CB), were made for 10 samples each. The veneer porcelain was added on under polycarbonate shell crown made by vacuum of full contour crown to obtain the same total thickness of the experiment crowns. The crowns were cemented onto the Cobalt-Chromium die. The dies were tilted 45 degrees from the vertical plane to obtain the shear force to the cusp when loading. All crowns were loaded at the lingual incline of the buccal cusp until fracture using a universal testing machine with cross-head speed 0.5 mm/min. The load to fracture values (N) was recorded and statistically analyzed by independent sample t-test. RESULTS. The mean and standard deviations of the failure load were $1,170.1{\pm}90.9$ N for EV design and $1,450.4{\pm}175.7$ N for CB design. A significant difference in the compressive failure load was found (P<.05). For the failure characteristic, the EV design was found only cohesive failures within veneering porcelain, while the CB design found more failures through the zirconia framework (8 from 10 samples). CONCLUSION. There was a significant difference in the failure load between two designs, and the design of the framework influences failure characteristic of zirconia crown.

$ZrO_2$첨가에 따른 자기 애자의 기계적 강도 개선 (Improvement of Mechanical Strength of Porcelain Insulator with $ZrO_2$Addition)

  • 최연규;송병기;안권옥;안용호;김상범;이동일
    • 한국세라믹학회지
    • /
    • 제38권5호
    • /
    • pp.454-460
    • /
    • 2001
  • 장석, 석영, 점토와 17 wt% $Al_2$O$_3$를 함유한 알루미나질 자기 애자를 제조하였다. 분말을 ball milling으로 6시간 분쇄하였으며 성형체를 압출법으로 제조한 후 터널가마에서 130$0^{\circ}C$, 50분 동안 소결하였다. 터널가마에서 소결한 시편의 소결밀도는 이론밀도의 97%에 도달하였고, 3점 꺾임강도는 1658kgf/$ extrm{cm}^2$ 이었으며 ICL(indentation crack length) 방법으로 측정한 파괴인성은 2.3 MPa.m$^{1}$2/이었다. 기계적 성질을 향상시키기 위하여 ZrO$_2$를 첨가하여 15 wt% $Al_2$O$_3$-2 wt% ZrO$_2$와 12 wt% $Al_2$O$_3$-5 wt% ZrO$_2$를 복합체를 제조하였다. ZrO$_2$를 첨가한 시편의 꺾임강도는 1740kgf/$\textrm{cm}^2$이고 파괴인성은 2.4 MPa.m$^{1}$2/로 약 10% 기계적 성질이 향상되었다.

  • PDF

FRACTURE STRENGTH AND MARGINAL FIT OF IN-CERAM, COPY-MILLED IN-CERAM, AND IPS EMPRESS 2 ALL-CERAMIC BRIDGES

  • Hwang Jung-Won;Yang Jae-Ho;Lee Sun-Hyung
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.641-658
    • /
    • 2001
  • All-ceramic restorations have become an attractive alternative to porcelain-fused-to-metal crowns. In-Ceram, and more recently IPS Empress 2 were introduced as a new all-ceramic system for single crowns and 3-unit fixed partial dentures. But their strength and marginal fit are still an important issue. This study evaluated the fracture resistance and marginal fit of three systems of 3 unit all-ceramic bridge fabricated on prepared maxillary anterior resin teeth in vitro. The 3 all-ceramic bridge systems were: (1) a glass-infiltrated, sintered alumina system (In-Ceram) fabricated conventionally, (2) the same system with copy-milled alumina cores (copy-milled In-Ceram), (3) a heat pressed, lithium disilicate reinforced glass-ceramic system (IPS Empress 2). Ten bridges of each system with standardized design of framework were fabricated. All specimens of each system were compressed at $55^{\circ}$ at the palatal surface of pontic until catastrophic fracture occurred. Another seven bridges of each system were fabricated with standard method. All of the bridge-die complexes were embedded in epoxy resin and sectioned buccolingually and mesiodistally. The absolute marginal discrepancy was measured with stereomicroscope at ${\times}50$ power. The following results were obtained: 1. There was no significant difference in the fracture strength among the 3 systems studied. 2. The Weibull modulus of copy-milled In-Ceram was higher than that of In-Ceram and IPS Empress 2 bridges. 3. Copy-milled In-Ceram($112{\mu}m$) exhibited significantly greater marginal discrepancy than In Ceram ($97{\mu}m$), and IPS Empress 2 ($94{\mu}m$) at P=0.05. 4. The lingual surfaces of the ceramic crowns showed smaller marginal discrepancies than mesial and distal points. There was no significant difference between teeth (incisor, canine) at P=0.05. 5. All-ceramic bridges of three systems appeared to exhibit sufficient initial strength and accept able marginal fit values to allow clinical application.

  • PDF

합착용 복합레진시멘트로 합착한 Machinable Ceramic과 상아질 사이의 인장강도에 대한 실험적 연구 (TENSILE STREGNTH BETWEEN MACHINABLE CERAMIC AND DENTIN CEMENTED WITH LUTING COMPOSITE RESIN CEMENTS)

  • 조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.487-501
    • /
    • 1998
  • In the case of CAD/CAM ceramic inlay restorations, if isthmus width is widened too much, it may cause fracture of remaining tooth structure or loss of bonding at the luting interface because of excessive displacement of buccal or lingual cusps under occlusal loads. So to clarify the criterior of widening isthmus width, this study was designed to test the tensile bond strength and bond failure mode between dentin and ceramic cemented with luting composite resin cements. Cylindrical ceramic blocks(Vita Cerec Mark II, d=4mm) were bonded to buccal dentin of 40 freshly extracted third molars with 4 luting composite resin cements(group1 : Scotchbond Resin Cement/Scotchbond Multi-Purpose, group2 : Duolink Resin Cement/ All-Bond 2, group3: Bistite Resin Cement/Ceramics Primer, and group4:Superbond C&B). Tensile bond test was done under universal testing machine using bonding and measuring alignment blocks(${\phi}ilo$ & Urn, 1992). After immersion of fractured samples into 1 % methylene blue for 24 hours, failure mode was analysed under stereomicroscope and SEM. Results: The tensile bond strength of goup 1, 2 & 4 was $13.97{\pm}2.90$ MPa, $16.49{\pm}3.90$ MPa and $16.l7{\pm}4.32$ MPa, respectively. There was no statistical differences(p>0.05). But, group 3 showed significantly lower bond stregnth($5.98{\pm}1.l7$ MPa, p<0.05). In almost all samples, adhesive fractures between dentin and resin cements were observed. But, in group 1, 2 & 4, as bond strength increased, cohesive fracture within resin cement was observed simultaneously. And, in group 3, as bond strength decreased, cohesive fracture between hybrid layer and composite resin cement was also observed. Cohesive fracture within dentin and porcelain adhesive fracture were not observed. In conclusion, although adhesive cements were used in CAD/CAM -fabricated ceramic inlay restorations, the conservative priciples of cavity preparation must be obligated.

  • PDF

A CONTROLLED CYCLIC LOADING ON THE SURFACE TREATED AND BONDED CERAMIC: STAIRCASE METHOD

  • Yi, Yang-Jin
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.298-306
    • /
    • 2008
  • STATEMENT OF PROBLEM: Effect of surface treatment of ceramic under loading does not appear to have been investigated. PURPOSE: The aim of this study was to investigate the effect of surface treatment of esthetic ceramic, which is performed to increase the bonding strength, on the fracture stress under controlled cyclic loading condition. MATERIAL AND METHODS: Sixty 1.0 mm-thick specimens were made from Mark II Vitablocs (Vita Zahnfabrik, Germany) and divided into 3 groups: polished (control), sandblasted, and etched. Specimens of each group were bonded to a dentin analog material base including micro-channels to facilitate the flow of water to the bonding interface. Bonded ceramics were cyclically loaded with a flat-end piston in the water (500,000 cycles, 15Hz). Following completion of cyclic loading, specimens were examined for subsurface crack formation and subsequent stress was determined and loaded to next specimen by the staircase method according to the crack existence. RESULTS: There were significant differences of mean fatigue limit in the sandblasted (222.86 ${\pm}$ 23.42 N) and etched group (222.86 ${\pm}$ 14.16 N) when compared to polished group (251.43 ${\pm}$ 10.6 N) (P<.05; Wald-type pair-wise comparison and post hoc Bonferroni test). Of cracked specimens, surface treated group showed longer crack propagation after 24 hours. All failures originated from the radial cracking without cone crack. Fracture resistance of this study was very low and comparable to failure load in the oral cavity. CONCLUSION: Well controlled cyclic loading could induce clinically relevant cracks and fracture resistance of Mark II ceramic was relatively low applicable only to anterior restorations. Surface treatment of inner surface of feldspathic porcelain in the matsicatory area could influence lifetime of restorations.

지르코니아-전장도재 계면의 전단결합강도에 대한 ZirLiner® 적용과 분사처리의 영향에 관한 연구 (Effect of Application of ZirLiner® and Blasting Treatments on Shear Bond Strength of Zirconia-Veneered Porcelain Interface)

  • 신영호;이유나;이해형;동진근;오상천
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.113-127
    • /
    • 2008
  • 이 연구의 목적은 지르코니아 도재 표면의 전단 결합 강도에서 $ZirLiner^{(R)}$와 블라스팅 처리의 적용 효과를 평가하기 위한 것이다. 60개의 무색의 지르코니아 판과 30개의 색이 있는 지르코니아 판이 규격화되고 연마, 글래스블라스팅, 알루미나블라스팅, 그리고 zirliner 같은 블라스팅 처리를 적용시키는 것에 따라 10개씩 9개의 그룹으로 나누어졌다. 시편을 고정대에 위치하고 만능시험기로 전단력을 측정하였다. 파절된 견본의 파절 표면은 SEM으로 검사되었다. 각 군별 시편을 통계처리하여 그 결과를 비교하였다.

3D printing으로 제작된 금속 코어와 치과용 도재 간의 전단결합강도 평가 (Evaluation of shear bond strength between metal core fabricated by 3D printing and dental porcelain)

  • 정재관;이수옥;김기백
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2585-2592
    • /
    • 2015
  • 3D 프린팅 기술은 최근 치과용 보철물 제작 기술로 도입이 되었다. 본 연구의 목적은 3D 프린팅 기술에 의해 제작된 금속 코어와 상부 도재와의 전단결합강도를 평가하는 것이다. 본 연구를 위해 30개의 금속 코어를 제작하였다(cast 15개, 3D printing 15개). 금속 코어에 치과용 도재를 축성하여 시편 제작을 완료하였다. 완성된 시편의 전단결합강도는 crosshead speed 1mm/min으로 하중을 가하여 측정하였으며, 두 그룹의 전단결합강도 값 사이에는 통계적으로 유의한지 알아보기 위하여 Mann-Whitney test를 이용하였다(유의수준 0.05). 측정이 끝난 후 시편을 대상으로 파절양상을 분석하였다. 본 연구를 위한 실험 설계, 금속 코어 제작, 도재 축성 등의 시편 제작부터 실험 수행과 수행 후 실험 데이터 분석과 통계 분석 그리고 파절된 시편을 대상으로 한 파절 양상 분석까지 총 6개월이 소요되었다. 실험 결과 cast 50.14, 3D printing 54.36 MPa를 갖는 것으로 조사되었고, 통계적으로도 유의하였다. 파절양상은 두 집단 모두 시편의 대부분이 혼합형 파절양상을 보였다. 이와 같은 결과들로 미루어볼 때 3D 프린팅에 의해 제작된 금속도재관 제작을 위한 금속 코어는 임상적으로 허용이 가능할 것으로 사료된다.

Alumina와 zirconia가 치과용 코아 도재의 물리적 성질에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECT OF ALUMINA AND ZIRCONIA ON MECHANICAL PROPERTIES OF DENTAL CORE PORCELAIN)

  • 신현수;이상진;이근우
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.317-349
    • /
    • 1993
  • This study investigated the effect of filler particle size and weight% on mechanical properties of dental core porcelain. In alumina, variation in particle size and weight% and in zirconia, variation in weight%, all specimens were tested three-point bending strength, transmittance, thermal expansion coefficient, porosity and shrinkage and observed with SEM and analysed with X-ray diffractometer. In order to develop shrink-free porcelain, after firing alumina only, glass wasinfiltrated. And aluminum was added to alumina with the expanding character of aluminum oxidize into alumina, and was followed by second firing of glass infiltration procedure. Then mechanical properties were observed. The results of this study were obtained as follows. 1. The bending strength of zirconia was higher than that of alumina, and $5{\mu}m$ alumina had highest strength in variation of particle size of alumina. Except for $5{\mu}m$ alumina, increased with weight%, bending strength increased up to 80% and decreased at 90%. In case of glass infiltration, bending strength was slight higher than 80% and 90% of $5{\mu}m$ alumina. 2. Transmittance increased with increase of shrinkage, decrease of porosity, and with increase of filler size and had no direct correlation with weight%. 3. Thermal expansion coefficient of alumina group was $7.42\sim8.64\times10^{-6}/^{\circ}C$ and that of zirconia group was $9.83\sim12.11\times10^{-6}/^{\circ}C$ and the latter was higher than the former. 4. In x-ray diffraction analysis, alumina group and zirconia group increased $Al_2O_3$ peak and $t-ZrO_2$ peak with increase of weight%. The second phase(cristobalite peak) was observed in zirconia 40% group. 5. Porosity of zirconia was lower than that of alumina and $5{\mu}m$ alumina group had many pores with SEM. In case of low filler content, fracture occurred in glass and high filler content, in glass and filler. In case of aluminum addition to alumina, small oxidised aluminum was observed. 6. Zirconia group had high shrinkage than alumina group, and mixed group of alumina group had high shrinkage. In case of glass infiltration, shrinkage decreased and aluminum addition to alumina group was almost shrink-free.

  • PDF

지르코니아, 유리침투알루미나 및 PFM 전부관 시스템의 파절 경향에 관한 비교연구 (A comparative study on the fracture behavior of zironia, glass infiltrated alumina and PFM full crown system)

  • 이상혁;안진수;김명호;임범순
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.235-242
    • /
    • 2012
  • 연구 목적: 본 연구는 지르코니아, 유리침투알루미나 및 금속도재소부용치관의 파절강도를 비교하고자 하였다. 연구 재료 및 방법: 지르코니아, 유리침투알루미나 및 금속도재소부용합금으로 각각 15개의 치관을 제작한 후, 제작된 치관을 장축에 $30^{\circ}$ 경사지게 제작된 지그에 장착하여 만능시험기로 파절강도를 측정하였으며, 전단결합강도 시험을 위하여 지르코니아, 유리침투알루미나 및 금속도재소부용합금을 $5.5({\phi}){\times}2.5mm$ 크기로 제작하고 포세린 분말을 $3.5({\phi}){\times}2.5mm$ 크기로 축성한 후 제조사의 설명서에 따라 전기로(Ceramco 7, Dentsply, USA)에서 소결하여 총10개의 시편을 제작하였다. 결과: 전부관 형태로 제작한 시편의 파절강도는 금속-도재 시스템이 $569.1{\pm}61.8N$, 알루미나-도재 시스템이 $551.0{\pm}76.5N$ 및 지르코니아-도재 시스템이 $588.3{\pm}49.6N$으로 측정되었으며, 각 실험군간 유의한 차이는 없었다(P>.05). 전단결합강도는 금속-도재 시스템이 $38.9{\pm}5.0MPa$, 알루미나-도재 시스템이 $39.4{\pm}5.1MPa$, 지르코니아-도재 시스템이 $25.5{\pm}5.6MPa$로 지르코니아-도재 시스템이 다른 두 시스템 보다 유의하게 낮은 값을 보였다(P<.05). 금속-도재 시스템, 알루미나-도재 시스템 및 지르코니아-도재 시스템의 각 결합계면을 SEM/EDS로 분석한 결과 각 시스템에서 상이한 결합 양상이 관찰되었다. 결론: 본 연구 결과 지르코니아-도재 시스템의 파절강도가 제일 높았으며, 금속-도재 시스템, 알루미나-도재 시스템 순서로 나타났으며, 전단결합강도는 알루미나-도재 시스템이 제일 높았고 금속-도재 시스템, 지르코니아-도재 시스템 순서으로 나타났다.