• Title/Summary/Keyword: Pond system

Search Result 219, Processing Time 0.028 seconds

Purification Technology in Closed Water like a Reservoir and Pond using Oxygen Solubilized Device and Standardized Microorganism Culture System (산소용해수와 미생물제재를 이용한 호소 및 폐쇄수역의 정화기술)

  • Seo, Seong-nyeo;Kim, Young-taek;Park, Chul-hwi
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.118-124
    • /
    • 2005
  • The oxygen solubilized device(O.S.D) and standardized microorganism culture system is more efficient than physical and chemical purification techniques in closed water. This study was to determine how the O.S.D and standardized culture system is efficient in purification capacity in closed water based on the lab scale and pilot plant. In the batch test, inducing the quantitative results from pilot plant operation condition, removal efficiency of COD and TN were about 48.3% and 35% respectively, while SS and chlorophyll-a were 94.9% and 68.7%. The pilot plant results showed that suspended solid(SS) and chlorophyll-a removal efficiency were 60% and 59% respectively, due to coagulation characteristics by standardized culture. Total nitrogen(TN) and total phosphorus(TP)showed good effect for the purification of target pond water quality from field data. Additionally, released velocity was determined in control condition of $5.31mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $2486.8mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. Otherwise, phosphate and COD reflux in the aeration and microorganism condition was showed $-9.95mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $-397.88mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. This technology is the most effective not only removal of SS and chlorophyll-a but also control of phosphate and COD release which is very important phenomena in evaluating water quality in closed water like a reservoir and pond.

Wastewater Treatment Eco-pond by Using Energy Circulation System (에너지 순환시스템을 이용한 생태연못의 수질개선)

  • Kim, Min-Young;No, Hwang-Won;Lee, Seung-Yoon;Jee, Hong-Kee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2127-2131
    • /
    • 2008
  • 본 연구는 자연생태하에서 지속가능한 태양에너지와 생태계작용에 의한 수질개선기법을 개발하기 위하여 생태연못을 설치하여 수질부하가 발생함에 따라 생태연못에 에너지를 순환시켜 생태적 수질정화 기능을 강화하는데 목적을 두었다. 본 연구에서 생태연못(Eco-Pond) 시스템의 수질개선 원리는 수중(유입수)의 침전, 유기산 생성, 메탄 발효, 호기성 산화, 광합성 산소배출 및 병원균 제거 등을 촉진시키기 위한 목적으로 축산농가 및 마을단위의 축산 및 생활하수 유입부에서 생태연못을 두어 수질을 개선하는 공법 즉, 산화조(Oxidation Pond)에 SolaBee 시스템을 결합한 모델을 제안하였다. 에너지 순환장치를 이용한 수질개선 방안으로는 태양열 연못 내에 물순환장치를 만들어 수체를 효율적으로 순환시키고 공기를 혼합시켜 부영양화가 진행되는 연못이 수질을 자연친화적으로 개선시키도록 하였다. 따라서 연구결과 태양에너지는 다른 자연에너지(풍력 등)에 비해서 에너지 밀도는 낮지만 지역의존성이 적고 그 양이 방대하여 21세기 중요한 에너지원으로 사용가능성을 확인할 수 있었다. 본 연구에서 제시된 에너지 순환구조를 가진 생태연못 시스템은 우리나라 중소규모의 농촌 및 축산농가에 보급 될 수 있는 수질개선 시스템이다.

  • PDF

Numerical Study of the Thermohaline Double-Diffusive System in a Solar Pond (태양연못 안의 열-염분 이중확산계에 대한 수치적연구)

  • Lim K.B;Park H.Y;Lee K.S
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.6
    • /
    • pp.606-612
    • /
    • 1987
  • In this study, numerical model was developed to predict behavior of several layers in a solar pond and was solved by finite difference method. The empirical correlation that described heat and salt fluxes across interfacial boundary layer between mixed layer and diffusive layer in a solar pond were obtained from experiments and utilized in developing numerical model. As the results of this study, heat and salt fluxes across the interfacial boundary layer was found to depend on density ratio ${\beta}{\Delta}M_s/{\alpha}{\Delta}T.$ It was also found that the predicted value obtained by using the modified Weinberger's stability criteria showed a good agreement with experiment data.

  • PDF

The Type Classification and Function Assessment at Small Palustrine Wetland in Rural Areas (농촌지역 소규모 소택형습지의 유형분류 및 기능평가 연구)

  • Son, Jin-Kwan;Kim, Nam-Choon;Kang, Bang-Hun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.6
    • /
    • pp.117-131
    • /
    • 2010
  • This study was conducted to utilize as basic information for the construction of conservation and estimation system for Palustrine wetland, which was badly managed and imprudently reclaimed, through the analysis of distribution characteristics and the estimation of conservation value for sample sites (eight wetlands) in rural area. As the result of wetland type classification, these wetlands was classified by 4 types (Permanent freshwater marshes/pools, ponds, Aquaculture ponds, and Seasonally flooded agricultural land) by Ramsar system, 3 types (Emergent Wetland, Aquatic Bed, and Scrub-Shrub Wetland) by NWI (Cowardin) System, 5 types (Farm Pond Depression, Under-flow wetland, Man-made Pond Depression, Abandoned Paddy Fields Wetland, and Reservoir Shore) by National Wetland's Categorical System, and 3 types (Aquatic Bed Wetland, Emergent Wetland, and Forested Wetland) by Lee (2000) System. These results suggest us developing the new type classification system for small Palustrine wetland in Korean rural areas. The score of function assessment (The Modified RAM) for small Palustrine wetlands was high at the wetlands nearby hills and rice paddy fields, and low at those nearby upper fields, which was mainly affected by land-use and vegetation. The functions as 'Flood/Storm Water Storage', 'Runoff Attenuation', 'Water Quality Protection' were resulted by the structural difference of inflow and outlet. Some functions as 'Wetland size', 'Wetland to immediate watershed ratio', 'Presence of boat traffic', 'Maximum water depth', 'Fetch of water's body' of RAM were not appropriate in evaluation of small wetlands in rural area. Which suggest us developing the new function assessment system for small Palustirne wetland in Korean rural areas.

Composting and trickling filter for treatment of olive mill waste

  • Li, Xinhua;Lin, Ching-Chieh;Sweeney, Daniel;Earl, Jessica;Hong, Andy
    • Advances in environmental research
    • /
    • v.2 no.2
    • /
    • pp.131-141
    • /
    • 2013
  • Agricultural practice and improper waste disposal in developing regions have resulted in environmental degradation in land and waters, for which low-cost, proven solutions are needed. We demonstrate in the laboratory the applications of composting and trickling filter techniques to treat olive mill wastes that can be implemented in the West Bank and other regions of the world. To a pomace waste sample from a California mill, we amended with saw dust (wood carbon source) and baking soda ($NaHCO_3$ alkalinity) at weight ratios of waste/wood/$NaHCO_3$ at 70:27:1 and composted it for periods of 11 and 48 days; the compost was used as an additive to potting soil for transplanting. The pomace sample was also blended into slurry and introduced to a water-circulating pond and trickling filter system (P/TF) to examine any inhibitive effect of the pomace on biological removal of the organic waste. The results showed the compost-amended potting soil supported plant growth without noticeable stress over 34 days and the P/TF system removed BOD and COD by >90% from the waste liquid within 2 days, with a first-order rate constant of 1.9 $d^{-1}$ in the pond. An onsite treatment design is proposed that promises implementation for agricultural waste disposal in developing regions.

Changes in BOD, COD, Chlorophyll-a and Solids in Aquaculture Effluent with Various Chemical Treatments

  • Park, Jeonghwan;Daniels, Harry V.
    • Journal of Marine Life Science
    • /
    • v.2 no.2
    • /
    • pp.49-55
    • /
    • 2017
  • Four chemical treatments with hydrogen peroxide (H2O2), copper sulfate (CuSO4), potassium permanganate (KMnO4) and chlorine (Cl2) were applied to the effluent pond water of a hybrid striped bass saltwater recirculating aquaculture system to compare their oxidation power. Four chemicals were applied at concentrations of 0 (control), 1, 5, 10 and 20 mg/l. An additional concentration of 40 mg/l was included in the chlorine treatment. Water samples from four hybrid striped bass ponds were tested with KMnO4 and Cl2. H2O2 did not reduce any of BOD, COD and chlorophyll-a, and copper sulfate was only effective on chlorophyll-a for the effluent pond. Removal efficiencies for chlorophyll-a by copper sulfate were 19.2%, 37.5%, 54.2% and 74.1% dose-dependently. Potassium permanganate effectively removed the BOD, COD and chlorophyll-a. The COD removal rates in four fish ponds varied from 15.9% to 31.6% at the concentration of 10 mg/l. Interestingly, Cl2 did not reduce the BOD and COD at all, but the BOD and COD instead increased drastically with increasing the Cl2 concentration. The pond water with the highest initial BOD and COD values among the fish ponds tested increased by 350% in the BOD and 150% in the COD at 20 mg/l. Furthermore, Cl2 did not significantly reduce any types of solid matter in this study, while KMnO4 seemed to reduce some extent volatile dissolved solid in the fish pond.

The Construction Work Method of Mixed Coal Ash in Ash Pond to Recycle as a Horizontal Drain Material (수평배수재로 재활용하는 회사장 혼합석탄재의 시공 방안)

  • Koh, Yongil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • The design for horizontal drain layer on soft ground starts from the decision that the material could be used or not, by verifying material condition in permeability of horizontal drain material according to the weight percent of the dry soil retained on #200 sieve. In the next step of the design, we estimate the thickness of horizontal drain layer to confirm trafficability of heavy machinery in construction work. Successively, the long-term functionality for good drainage of horizontal drain layer is checked and if needed, some means are considered. In this study, the system to recycle mixed coal ash in ash pond successfully as a horizontal drain material on soft ground is presented through the process and the result of its practical construction work. Namely, the pact is confirmed that mixed coal ash in ash pond should be sorted out by sieve screen to a certain extent and the remainders of this mixed coal ash on sieve openings be recycled, because the amount of finer particles than $75{\mu}m$ contained in mixed coal ash in ash pond is quite massive and irregular depending on the coal power plant or the location in same ash pond. In order to sort at large scale in situ, the dimension of a sieve squre hole and the sort-out method, etc. should be decided before the sort-out process. And, it is described that we need to manufacture classifier to sort out mixed coal ash in ash pond, too.

Real-Time Measurement of Fry in the Cultivation Field Using a Line-Image Sensora

  • Ishimatsu, T.;Kawasue, K.;Kumon, T.;Ochiai, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.822-825
    • /
    • 1988
  • In this paper, we present a system which enables a real-time measurement of the number and also the body length of the fry (baby fish) using a line image sensor. Here, we consider a situation that fry are transported from a pond to another, pond through a pipe. At one position of the pipe a transparent rectanglar channel is mounted. The images of the fry, which run through this rectanglar channel, are detected by a line image sensor. The image signals are digitized to binary ones and the contour of the fry are detected. After that, a real-time image analysis is executed with a digital signal processor. Labeling program analyses the connection of every pixel. The results are transfered to a personal computer and displayed on the online monitor graphically.

  • PDF

A Study on the Compositional Characteristics of Water Systems and Landscapes in Traditional Chinese Seowons (중국 전통서원의 수체계와 수경관의 구성적 특성)

  • MA, Shuxiao;RHO, Jaehyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.3
    • /
    • pp.74-100
    • /
    • 2022
  • The purpose of this study was to investigate the characteristics of Chinese seowons and to obtain data based on the characteristics of waterscapes unique to Korean seowons. The conclusion of this study from the results of investigation and analysis of the location, water system, and design characteristics of 10 representative traditional seowons in China including Yuelu Seowon(嶽麓書院) conducted based on literature research and field observation is as follows. The water system of Chinese seowons is dualized into an inner and an outer water system, and in general, two and a maximum of three water bodies are superimposed on the outside. The locations of seowons are classified into five types: Four double-sided round water type sites, three converted face water type sites, one three-sided round water type site, a four-sided round water type, and a waterproofing type(依山傍水型). Therefore, compared to the typical Korean seowon facing water in the front and a mountain in the back(背山面水型), the Chinese seowons showed a highly hydrophilic property. The water shapes of the external water system were meandering(46.0%), mooring(36.0%), and broad and irregular(9.0%). In addition, water conception(水態) were streams(31.8%), rivers(27.3%), springs(13.6%), falls(9.1%), lakes(4.5%) and ponds(4.5%), in that order. As for waterscapes of the water system inside the seowon, there were seven in Akrok Seowon and four in Mansong Seowon, indicating a comparatively higher number of waterscapes. Since the 27 detailed waterscapes in 10 seowons that were the subject of the study were classified into six types including ponds and half-moon ponds, they appeared to be more diverse than the Korean seowon. It is noteworthy that in the interior waterscape of the traditional Chinese seowon, the ritualistic order, where at least one half-moon pond or square pond(方池) was arranged, is well displayed. In particular, the half-moon pond(伴池), which is difficult to find in Korean seowon, was found to be a representative waterscape element, accounting for 42.8%. If the square pond of Nanxi Seowon based on Zhu Xi's poem 「Gwanseoyugam(觀書有感)」 is also treated as a square-shaped half-moon pond, the proportion of half-moon ponds in the waterscape will be as high as 50%. The pond shapes consisted of 28% square, 24% each for free curve and round shape, 20% for semi-moon shape, and 3.8% for mountain stream type. This seems to differ greatly from the square-shaped Korean seowon. On the other hand, there were a total of 10 types of structures related to the waterscape inside the Chinese seowon: 11(26.8%) pavilion and bridge sites, five gate room sites(牌坊: 16.5%), four gate and tower sites(樓, 1.4%), two Jae sites(齋, 6.2%), and one site each(3.1%) of Heon(軒), Sa(祠), Dae(臺), and Gak(閣). In particular, the pavilions inside seowon were classified into three types: landscape pavilion(景觀亭 27.2%), tombstone pavilion(碑亭, 18.2%), and banquet pavilion(宴集亭, 54.5%). In general, it was confirmed that the half-moon pond with a pedestal bridge, and the pavilion were the major components with a high degree of connection that dominate the waterscape inside the Chinese seowon.