• Title/Summary/Keyword: Polymethylmethacrylate

Search Result 174, Processing Time 0.036 seconds

Physical and Optical Properties of PMMA/PVDF Blends (PMMA/PVDF 화합물의 물성 및 광학적 성질)

  • 김병철;최춘기;한상필;윤근병;정명영
    • Polymer(Korea)
    • /
    • v.26 no.4
    • /
    • pp.462-467
    • /
    • 2002
  • Blends of polymethylmethacrylate (PMMA) with polyvinylidenefluoride (PVDF) were prepared by melt mixing and investigated for optical waveguide devices by using hot embossing process. The glass transition temperatures ($T_g$) of the blends were decreased with increasing PVDF contents. However, the crystalline of PMMA/PVDF blends was not appeared by DSC and XRD due to miscibility between PMMA and PVDF. Shear viscosities and refractive indices of the blends were decreased with increasing PVDF contents. Optical transmittances and absorption losses of the blends were improved with increasing PVDF contents. This is due to a decreasing of polarizability of molecules by fluorine molecule in the PVDF.

Barrier Techniques for Spinal Cord Protection from Thermal Injury in Polymethylmethacrylate Reconstruction of Vertebral Body : Experimental and Theoretical Analyses (Polymethylmethacrylate를 이용한 척추체 재건술에서 척수의 열 손상을 방지하기 위한 방어벽 기법 : 실험적 및 이론적 분석)

  • Park, Choon Keun;Ji, Chul;Hwang, Jang Hoe;Kwun, Sung Oh;Sung, Jae Hoon;Choi, Seung Jin;Lee, Sang Won;Park, Sung Chan;Cho, Kyeung Suok;Park, Chun Kun;Yuan, Hansen;Kang, Joon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.3
    • /
    • pp.272-277
    • /
    • 2001
  • Objective : Polymethylmethacrylate(PMMA) is often used to reconstruct the spine after total corpectomy, but the exothermic curing of liquid PMMA poses a risk of thermal injury to the spinal cord. The purposes of this study are to analyze the heat blocking effect of pre-polymerized PMMA sheet in the corpectomy model and to establish the minimal thickness of PMMA sheet to protect the spinal cord from the thermal injury during PMMA cementation of vertebral body. Materials & Methods : An experimental fixture was fabricated with dimensions similar to those of a T12 corpectomy defect. Sixty milliliters of liquid PMMA were poured into the fixture, and temperature recordings were obtained at the center of the curing PMMA mass and on the undersurface(representing the spinal cord surface) of a prepolymerized PMMA sheet of variable thickness(group 1 : 0mm, group 2 : 5mm, or group 3 : 8mm). Six replicates were tested for each barrier thickness group. Results : Consistent temperatures($106.8{\pm}3.9^{\circ}C$) at center of the curing PMMA mass in eighteen experiments confirmed the reproducibility of the experimental fixture. Peak temperatures on the spinal cord surface were $47.3^{\circ}C$ in group 2, and $43.3^{\circ}C$ in group 3, compared with $60.0^{\circ}C$ in group 1(p<0.00005). So pre-polymerized PMMA provided statistically significant protection from heat transfer. The difference of peak temperature between theoretical and experimental value was less than 1%, while the predicted time was within 35% of experimental values. The data from the theoretical model indicate that a 10mm barrier of PMMA should protect the spinal cord from temperatures greater than $39^{\circ}C$(the threshold for thermal injury in the spinal cord). Conclusion : These results suggest that pre-polymerized PMMA sheet of 10mm thickness may protect the spinal cord from the thermal injury during PMMA reconstruction of vertebral body.

  • PDF

Comparative study of surface modification on bond strength of polyetherketoneketone adhesively bonded to resins for temporary restoration (Polyetherketoneketone의 표면처리 방법에 따른 임시 보철물 제작용 레진과의 결합 강도 비교 연구)

  • Hong, Mun Gi;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • Purpose: The purpose was to compare shear bond strength (SBS) of three types of resin for temporary restoration to polyetherketoneketone (PEKK) depending on surface modification. Materials and Methods: Sixty disks made from PEKK were air-abraded with 110 ㎛ alumina particles (Cobra, Renfert GmbH, Hilzinge, Germany) and thirty specimens were divided into two groups each: PEKK without Visio.link (Bredent, Senden, Germany)(U) and with Visio.link (P). Resins for temporary restoration (polymethylmethacrylate; PMMA, polyethylmethacrylate; PEMA, bis-acryl composite resin) in the shape of a square with one side 3.2 mm were bonded to PEKK twenty respectively and classified into six groups (UM, UE, UC, PM, PE and PC). All specimens were stored in distilled water at 37℃ for 24 hours. SBS of each group was measured at a crosshead speed of 2 mm/min in universal testing machine. SBS was compared using one-way ANOVA and a Tukey HSD test (P = 0.05). Results: Group UM and group UE showed a significant difference in SBS with group UC (P < 0.05). Group PC showed a significant increase in SBS than group UC (P < 0.05). Conclusion: It is recommended to apply Visio.link to PEKK for adhering bis-acrylic composite resin, but not for PMMA and PEMA in clinical practice.

Surface Modification of Polymethylmethacrylate(PMMA) by Ion-assisted reaction (이온 보조 반응법(Ion-assisted-reaction)을 이용한 Polymethylmethacrylate (PMMA)의 표면개질)

  • Jung, Sun;Cho, Jun-Sik;Choi, Sung-Chang;Koh, Seok-Keun
    • Korean Journal of Materials Research
    • /
    • v.9 no.5
    • /
    • pp.446-451
    • /
    • 1999
  • Surface of Polymethylmethacrylate (PMMA) was modified by ion assisted reaction in which ion beam of Ar or$ O_2$is irradiated on polymer in reaction gas environment. Ion beam energy was changed from 600 to 1000eV, and ion doses were varied from $5\times10^{14} ions/cm^2 to 1\times10^{17} ions/cm^2$. Contact angle and surface energy of modified PMMA were measured by contact angle micrometer using distilled water and formamide. In the case of $Ar^+$ ion irradiation only, the contact angle reduced from $68^{\circ} to $35^{\circ}$ and the surface energy was changed from 46 dyne/cm to 60 dyne/cm. The contact angle significantly decreased to $14^{\circ}$and the surface energy increased to 72 dyne/cm when the surface of PMMA was modified by oxygen ion irradiation in oxygen gas environment. Improvement of wettability results from the formation of new hydrophilic group which is identified as C-O chain by XPS analysis. Recovery of wettability in dry air and maintenance of it in water condition were explained in view of the formation of hydrophilic group.

  • PDF

Fluorination of Polymethylmethacrylate (PMMA) Film and Its Surface Characterization (폴리메틸메타아크릴레이트(PMMA) 필름의 불소화 및 그 표면특성)

  • Jung, Min-Jung;Lim, Jae-Won;Park, In-Jun;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.317-322
    • /
    • 2010
  • In this study, poly(methyl methacrylate) (PMMA) was treated with changing mixing ratios of $F_2$ and $O_2$ using oxyfluorination method for hydrophilic modification of PMMA film. For the characterizations of oxyfluorinated PMMA surface, contact angle, surface free energy, X-ray photoelectron spectroscopy (XPS) and optical transmittance (UV-vis) were carried out. After the oxyfluorination, PMMA surface became more hydrophilic showing the decrease of water contact angle from $69^{\circ}$ to $44^{\circ}$. So, surface free energy of oxyfluorinated PMMA film was increased from 46 to $58\;mN\;m^{-1}$. These results are attributed to hydrophilic functional groups such as hydroxyl group formed oxyfluorination method on the PMMA surface. From XPS results, it was confirmed that O/C concentration ratio on the surface of PMMA was increased, the amount of C-OH bonding which shows hydrophilicity was also largely increased from 6.7 to 24.8% with increasing fluorine partial-pressure via the oxyfluorination, The oxyfluorination conditions, room temperature, 1 bar with one mixture ratio of $F_2$ to $O_2$ had little influence on optical transmittance properties of PMMA film but enhanced its surface hydrophilicity. This result suggests that oxyfluorination method could be useful to change hydrophobic PMMA surface to hydrophilic.

Percutaneous Polymethylmethacrylate Vertebroplasty in the Treatment of Osteoporotic Thoracic and Lumbar Vertebral Body Compression Fractures : Outcome of 159 Patients (159명의 골다공증성 흉추 및 요추부 골다공증성 추체 압박골절 환자에 대한 경피적 척추성형술 후 치료결과)

  • Lee, Jae-Un;Ryu, Kyeong-Sik;Park, Chun-Kun;Choi, Yeong-Kun;Park, Chun-Kun;Ji, Chul;Cho, Kyung-Suk;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.173-179
    • /
    • 2001
  • Purpose : To assess therapeutic effects of percutaneous polymethylmethacrylate(PMMA) vertebroplasty on the pain caused by osteoporotic thoracic and lumbar vertebral body compression fractures in a large scale of a prospective clinical design, and to determine clinical factors influencing its therapeutic effects. Methods : A prospective clinical study was carried out in 349 vertebral levels of 159 patients between April 1998 and July 1999. The compression fractures were confirmed with bone scan and spine CT, and bone marrow density was measured. Visual analogue scale(VAS) score was used for pre- and post-operative assessments of the pain. All 159 patients were assessed immediately after surgery, and 140 patients of them were followed-up for about 6 months in average. Results : Partial and complete pain relief was sustained immediately after operation in 73%, through follow-up period in 88% of the patients. Pain relief was not proportional to the amount of PMMA or the rate of increase in the height of the compressed vertebral body. It appears that 3 to 6cc of PMMA was proper enough to sustain pain relief. Better clinical improvement was achieved in the patients treated within 6 months after occurrence of vertebral body fracture. The most frequent surgical complication was epidural leakage of PMMA, and the most serious complication was extravertebral leakage into the paravertebral muscles, which appeared to exert the worst influence on the outcome. However, surgery was not required in these patients. Conclusion : Therapeutic effects of PMMA percutaneous vertebroplasty on osteoporotic vertebral body compression fractures were confirmed in a relatively large scale of prospective clinical study. It appears that good outcome can be achieved in patients treated within 6 months after fracture, treated each level with 3 to 6cc of PMMA in amount. without serious complications.

  • PDF

A Method for Noninvasive Diagnosis of Bone using Ultrasonic Doppler Method (초음파 Doppler법에 의한 생체 경조직의 비침투적인 진단을 위한 기초실험)

  • 박무훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.7
    • /
    • pp.3-11
    • /
    • 1998
  • 본 논문에서는 분포정수선로의 간단한 모델을 이용해서, 외부에서 진동을 가했을 때 에 뼈 표면에서 발생하는 굴곡파의 전파속도와 종파의 전파속도를 구할 수 있는 새로운 측 정원리를 제안했다. 이 측정원리를 이용해서, 봉(brass, polymethylmethacrylate)표면에 발생 하는 정재파에 대한 속도의 공간분포를 laser Doppler법으로 측정해서, 각각의 주파수에 대 한 전파속도를 구했다. 이 새로운 측정방법은 in vivo에서 초음파 Doppler법을 이용해서 뼈 의 이상(골다공증, osteoporosis)진단의 가능성을 제시했다.

  • PDF

Simulation of the PMMA development course in LIGA process (LIGA 공정 중 PMMA 현상 과정의 모사)

  • 임종석;이선아;구양모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.733-736
    • /
    • 2000
  • In the first step of the LIGA process a resist layer, typically PMMA(polymethylmethacrylate), is pattered by deep X-ray lithography. Then the exposed parts are dissolved by an organic developer. To describe the developer. To describe the development course the parameters influencing the development process was investigated. The developed depth is proportional to the square root of the development time which suggests that the development rate increases with increasing dose value and temperature. So the development course can be described by a phenomenological equation.

  • PDF

Berkovich 팁을 이용한 PMMA의 초미세 가공에서 가공속도가 변형거동에 미치는 영향

  • 윤성원;김현일;강충길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.147-147
    • /
    • 2004
  • 폴리메틸메타크릴레이트(polymethylmethacrylate, PMMA)는 아크릴레이트계 고분자이자 열가소성 플라스틱으로써 LCD용 도광판, 콘택트렌즈, 치과용 레진, DVD 디스크용 소재, 나노임프린트용 피가공재, 나노리소그래피 공정용 레지스트 등 많은 분야에서 활발히 사용되고 있다. PMMA 와 같은 점소성 점탄성 소재의 기계적 성질 측정 및 가공을 위해서는, 응력완화 (stress relaxation), 크립 (creep)등과 같은 시간의존적 변형거동에 대한 연구가 선행되어야 한다.(중략)

  • PDF

Fabrication of Resistive Switching Memory based on Solution Processed AlOx - PMMA Blended Thin Film

  • Sin, Jung-Won;Baek, Il-Jin;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.181.1-181.1
    • /
    • 2015
  • 용액 공정을 이용한 Resistive random access memory (ReRAM)은 간단한 공정 과정, 대면적화, 저렴한 가격 등의 장점으로 인해 큰 관심을 받고 있으며, HfOx, TiOx, AlOx 등의 산화물이 ReRAM 절연 막으로 주로 연구되고 있다. 더 나아가 최근에는 organic 물질을 메모리 소자로 사용한 연구가 보고되고 있다. 이는 경제적이며, wearable 또는 flexible system에 적용이 용이하다. 그럼에도 불구하고, organic 물질을 갖는 메모리 소자는 기존의 산화물 소자에 비해 열에 취약하며 전기적인 특성과 신뢰성이 우수하지 못하다는 단점을 가지고 있다. 이를 위한 방안으로 본 연구에서는 AlOx - polymethylmethacrylate (PMMA) blended thin film ReRAM을 제안하였다. 이는 organic물질의 전기적 특성을 개선시킬 뿐 아니라, inorganic 물질을 wearable 소자에 적용했을 때 발생하는 crack과 같은 기계적 물리적 결함을 해결할 수 있는 새로운 방법이다. 먼저, P-type Si 위에 습식산화를 통하여 SiO2 300 nm 성장시킨 기판을 사용하여 electron beam evaporation으로 10 nm의 Ti, 100 nm의 Pt 층을 차례로 증착하였다. 그리고 PMMA 용액과 AlOx 용액을 초음파를 이용하여 혼합한 뒤, 이 용액을 Pt 하부 전극 상에서 spin coating방법으로 1000 rpm 10초, 5000 rpm 30초의 조건으로 증착하였다. Solvent 및 불순물 제거를 위하여 150, 180, $210^{\circ}C$의 온도로 30 분 동안 열처리를 진행하였고, shadow mask를 이용하여 상부 전극인 Ti를 sputtering 방식으로 100 nm 증착하였다. 150, 180, $210^{\circ}C$로 각각 열처리한 AlOx - PMMA blended ReRAM의 전기적 특성은 HP 4156B semiconductor parameter analyzer를 이용하여 측정하였다. 측정 결과 제작된 소자 전부에서 2 V이하의 낮은 동작전압, 안정된 DC endurance (>150cycles), 102 이상의 높은 on/off ratio를 확인하였고, 그 중 $180^{\circ}C$에서 열처리한 ReRAM은 더 높은 on/off ratio를 갖는 것을 확인하였다. 결론적으로 baking 온도를 최적화하였으며 AlOx - PMMA blended film ReRAM의 우수한 메모리 특성을 확인하였다. AlOx-PMMA blended film ReRAM은 organic과 inorganic의 장점을 갖는 wearable 및 system용 비휘발성 메모리소자에 적용이 가능한 경제적인 기술로 판단된다.

  • PDF