• Title/Summary/Keyword: Polyethyleneimine(PEI)

Search Result 58, Processing Time 0.022 seconds

Immobilization of Glucose Oxidase using Branched Polyethyleneimines of Various Molecular Weights for Glucose Based Biofuel Cell (글루코스 기반 바이오연료전지를 위한 다양한 분자량의 폴리에틸렌이민을 이용한 글루코스 산화효소 고정화)

  • Ahn, Yeonjoo;Chung, Yongjin;Kwon, Yongchai
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.693-697
    • /
    • 2016
  • In this study, we fabricated the catalysts for enzymatic biofuel cell anode with carbon nanotube (CNT), glucose oxidase (GOx) and various molecular weights branched poly(ethyleneimine)(bPEI) and terephthalaldehyde (TPA) as cross-linker. In case of GOx/bPEI/CNT using only physical entrapments for immobilization, the molecular weights of bPEI didn't affect to electrochemical performances and long term stability. but that of the catalysts cross linked via TPA (TPA[GOx/bPEI/CNT]) improved and the mass transfer of glucose to FAD was interrupted as increasing of the bPEI's molecular weights. Furthermore, it was confirmed that the optimum molecular weight of PEI for TPA [GOx/bPEI/CNT]) structure is 750k that showed marvelous high performance (maximum power density of $0.995mW{\cdot}cm^{-2}$).

Preparation of Selectively Permeable Membrane Materials with Enhanced Protective Capability against Blister Agents (수포작용제 방호성능이 향상된 선택투과막 제조)

  • Kwon, Tae-Geun;Kim, Jin-Won;Kang, Jae-Sung;Park, Hyen-Bae;Lee, Hae-Wan;Seo, Hyeon-Kwan
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.167-175
    • /
    • 2014
  • For selectively permeable membrane based on cellulose acetate butyrate (CAB) and polyethyleneimine (PEI) with water vapor transportability and DMMP protective performance, we intended to improve protective performance of the membrane against CEES using several additives. Results showed that CAB/PEI membranes possessed performance with good water vapor permeation (${\geq}1,800g/m^2/day$) and enhanced protective capability against CEES contamination ($7.1{\sim}11.5{\mu}g/cm^2{\cdot}day$). Of these membranes, the membrane containing $Ag^+$ ion and ionic exchange resin showed the best protective performance. And, we identified that the CAB/PEI membranes show excellent protection against aerosols with various particle sizes ($0.005{\sim}3{\mu}m$) simulating biological agents.

Study of an electrochemical analysis method for Indole-3-Acetic Acid based on reduced graphene oxide composite catalyst coated screen-printed carbon electrode (환원 그래핀 옥사이드 복합 촉매가 코팅된 스크린 프린트 탄소전극 기반 Indole-3-Acetic Acid 전기화학분석법 연구)

  • Yoo-Jin Weon;Min-Yeong Kim;Young-Bae Park;Kyu Hwan Lee
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.4
    • /
    • pp.265-273
    • /
    • 2024
  • An amperometric sensor for measuring indole-3-acetic acid (IAA) was studied based on a screen-printed carbon electrode (SPCE) coated with a reduced graphene oxide composite electrocatalyst. The PEI-GO dispersion is uniformly formed through a nucleophilic substitution reaction between the active amine group of Polyethyleneimine (PEI) and the epoxide group exposed on the surface of graphene oxide. And The 3-dimensional PEI-rGO AG (Polyethyleneimine-reduced graphene oxide aerogel) complex was easily prepared through simple heat treatment of the combined PEI-GO dispersion. The proposed composite catalyst electrode, PEI-rGO AG/SPCE, showed a two linear relationship in the low and high concentrations in IAA detection, and the linear equation was Ipa = 0.2883C + 0.0883 (R2=0.9230) at low concentration and Ipa = 0.00464C + 0.6623 (R2=0.9894) at high concentration was proposed, and the detection limit was calculated to be 203.5nM±33.2nM. These results showed the applicability of the PEI-rGO AG composite catalyst as an electrode material for electrocatalysts for the detection of IAA.

Glucose Diffusion Limiting Membrane Based on Polyethyleneimine (PEI) Hydrogel for the Stabilization of Glucose Sensor

  • Kim, Suk-Joon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.225-229
    • /
    • 2021
  • Commercially available continuous glucose sensors require the operation stability for more than two weeks. Typically, the sensor comprises a sensing layer and an over-coating layer for the stable operation inside the body. In the sensing layer, enzymes and mediators are cross-linked together for the effective sensing of the glucose. The over-coating layer limits the flux of glucose and works as a biocompatible layer to the body fluids. Here, we report the simple preparation of the flux-limiting layer by the condensation of polyethyleneimine (PEI), tri-epoxide linker, and trimethylolpropane triglycidyl ether (PTGE). The sensor is constructed by a layer-by-layer drop-coating of the sensing layer containing glucose dehydrogenase and the PEI-derived blocking layer. It is stable for more than 14 days, which is enough for the sensor in the continuous monitor glucose monitoring (CGM) system.

Nonionic Amphiphilic Surfactant Conjuncted Polyethyleneimine as a New and Highly Efficient Non-viral Gene Carrier

  • Yin, Dongfeng;Chu, Cang;Ding, Xueying;Gao, Jing;Zou, Hao;Gao, Shen
    • Macromolecular Research
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • In order to enhance the gene delivery efficiency and decrease the cytotoxicity of polyplexes, we synthesized Solutol-g-PEI by conjugating polyethyleneimine (PEI) to Solutol (polyoxyethylene (10) stearate), and evaluated its efficiency as a possible nonviral gene carrier candidate. Structural analysis of synthesized polymer was performed by using $^1H$-NMR. Gel retardation assay, particle sizes and zeta potential measurement confirmed that the new gene carrier formed a compact complex with plasmid DNA. The complexes were smaller than 150 nm, which implicated its potential for intracellular delivery. It showed lower cytotoxicity in three different cell lines (Hela, MCF-7, and HepG2) than PEI 25 kDa. pGL3-lus was used as a reporter gene, and the transfection efficiency was in vitro measured in Hela cells. Solutol-g-PEI showed much higher transfection efficiency than unmodified PEI 25 kDa.

A Study on Performance Improvement of Glucose Sensor Adopting a Catalyst Using New Cross Liker (새로운 가교제를 적용한 촉매를 이용한 글루코스 센서의 성능향상 연구)

  • Chung, Yongjin;Kwon, Yongchai
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.802-807
    • /
    • 2015
  • In this study, we synthesized a new biocatalyst consisting of glucose oxidase (GOx), polyethyleneimine (PEI) and carbon nanotube (CNT) with addition of terephthalaldehyde (TPA) (TPA/GOx/PEI/CNT) for fabrication of glucose sensor that shows improved sensing ability and stability compared with that using other biocatalysts. Main bonding of the new TPA/GOx/PEI/CNT catalyst is formed by Aldol condensation reaction of functional end groups between GOx/PEI and TPA. Such formed bonding structure promotes oxidation reaction of glucose. Catalytic activity of TPA/GOx/PEI/CNT is evaluated quantitatively by electrochemical measurements. As a result of that, large sensitivity value of $41{\mu}Acm^{-2}mM^{-1}$ is gained. Regarding biosensor stability of TPA/GOx/PEI/CNT catalyst, covalent bonding formed between GOx/PEI and TPA prevents GOx molecules from becoming leaching-out and contributes improvement in biosensor stability. With estimation of the biosensor stability, it is found that the TPA/GOx/PEI/CNT catalyst keeps 94.6% of its initial activity even after three weeks.

The Efficacy of β-cyclodextrin/polyethyleneimine/silk Fibroin Hydrogel in Healing Burnt Wound (사이클로덱스트린/폴리에틸렌이민/실크 피브로인 수화겔의 화상치유효능)

  • Seo, Seung Ree;Lee, Mi Sun;Kim, Jin-Chul
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.599-604
    • /
    • 2011
  • In this study, we investigated the efficacy of ${\beta}$-cyclodextrin (${\beta}CD$) hydrorogel containing silk fibroin (SF) on healing burnt wound. Tosyl ${\beta}CD$ was conjugated to polyethyleneimine (PEI) using epichlorohydrin (EPI) as a cross-linker. The ${\beta}CD/PEI/SF$ hydrogel was applied on the back of mouse and then the efficacy of hydrogel was compared with both positive control group and negative control group. There was no wound healing efficacy showed neither in the drug loaded ${\beta}CD/PEI/SF$ hydrogel group nor in the drug unloaded ${\beta}CD/PEI/SF$ hydrogel group. On the other hand, in the positive control group, a significant reduction of the wound size after the usage of OTC hydrorogel was obtained. The burn-healing histological result showed a similar phenomenon. After hematoxylin-eosin staining the skin induced by burning, and the epithelial growth observed in the dermis, the efficacy of ${\beta}CD/PEI/SF$ hydrogel in healing burnt wound could not be clearly identified.

Synthesis and Characterization of Carbon Dioxide Sorbent by using Polyethyleneimine Impregnated Fumed Silica Particles (폴리에틸렌이민이 함침된 흄드 실리카 입자를 이용한 이산화탄소 흡착 소재의 제조 및 특성)

  • Hwang, Ha Soo;Park, In;Lee, Il Ki;Choi, Won Jun;Lee, Sang Il;Lee, Jun-Young
    • Applied Chemistry for Engineering
    • /
    • v.23 no.4
    • /
    • pp.383-387
    • /
    • 2012
  • This paper presents an easy way to prepare carbon dioxide sorbent by using commercially available fumed silica particles (AEROSIL). AEROSIL was impregnated with various concentration of polyethyleneimine (PEI) in methanol and $CO_2$ capture ability was analyzed by thermo gravity analysis (TGA). The $CO_2$ adsorption capacity of 50 wt% PEI-impregnated AEROSIL was 126.2 mg/g-sorbent at $75^{\circ}C$ and this capacity was substantially higher than that of the mesoporous silica such as HMS (101.0 mg/g-sorbent) and MSU-J (66.1 mg/g-sorbent).

Restoration of Membrane Performance for Damaged Reverse Osmosis Membranes through in-situ Healing (손상된 역삼투막의 in-situ 힐링을 통한 막 성능 복원)

  • Yun, Won Seob;Rhim, Ji Won;Cho, Young Ju
    • Membrane Journal
    • /
    • v.29 no.2
    • /
    • pp.96-104
    • /
    • 2019
  • The purpose of this paper is whether or not the in-situ restoration of the reverse osmosis (RO) membranes which its membrane function is lost is possible. The damaged RO membranes are double coated through the salting-out method by the poly(styrene sulfonic acid) sodium salt as the cationic exchange polymer and the polyethyleneimine as the anionic exchange polymer and also conducted the opposite order of the coating materials. And according to the concentration, time and ionic strength, the flux and rejection are measured for the coated membranes. Then the best coating condition is to apply for the RO membrane module of the household water purifier to know the possibility of the in-situ restoration for the commercial module. When the condition of the PEI 30,000 ppm (IS = 0.1)/PSSA 20,000 ppm (IS = 0.7) is applied, the rejection was enhance from 69% for the damaged module to 86% (90% for the pristine module).

Performance Evaluation of Biofuel cell using Benzoquinone Entrapped Polyethyleneimine-Carbon nanotube supporter Based Enzymatic Catalyst (벤조퀴논 포집 폴리에틸렌이민-탄소나노튜브 지지체 기반 효소촉매의 바이오연료전지로서의 성능평가)

  • Ahn, Yeonjoo;Chung, Yongjin;Kwon, Yongchai
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.258-263
    • /
    • 2017
  • In this study, we synthesized biocatalyst consisting of glucose oxidase (GOx), polyethyleneimine (PEI) and carbon nanotube (CNT) with addition of p-benzoquinone (BQ) that was considered anodic catalysts of enzymatic biofuel cell (EBC). For doing this, PEI/CNT supporter was bonded with BQ by physical entrapping method stemmed from electrostatic attractive force ([BQ/PEI]/CNT). In turn, GOx moiety was further immobilized on the [BQ/PEI]/CNT to form GOx/[BQ/PEI]/CNT catalyst. This catalyst has a special advantage in that the BQ that has been usually dissolved into electrolyte was immobilized on supporter. According to the electrochemical analysis, maximum current density of the GOx/[BQ/PEI]/CNT catalyst was 1.9 fold better than that of the catalyst that did not entrap BQ with the value of $34.16{\mu}A/cm^2$, verifying that catalytic activity of the catalyst was enhanced by adoption of BQ. Also, when it was used as anodic catalyst of the EBC, its maximum power density was 1.2 fold better than that of EBC using the catalyst that did not entrap BQ with the value of $0.91mW/cm^2$. Based on such results, it turned out that the GOx/[BQ/PEI]/CNT catalyst was promising and viable as anodic catalyst of EBC.