The Influence of E-beam Irradiation on POLY(ETHER-BLOCK-AMIDE) (PEBA, Pebax) (전자 빔 조사후 PEBA (Poly Ether Block Amide)의 구조 및 기계적 특성 변화)

  • Shin, Sukyoung;Cho, SangGyu
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.205-209
    • /
    • 2014
  • Medical polymers require sterilization and must be able to maintain material properties for a specified shelf life. Sterilization can be achieved by using gamma or e-beam exposure. In this study, accelerated aging tests of poly(ether-block-amide) (PEBA) copolymer samples is presented. PEBA copolymer samples with different polyether content that result in Shore hardness of 35D to 72D, were sterilized using e-beam radiation followed by accelerated aging at $55^{\circ}C$. E-beam sterilization effect on molecular weight and mechanical property has performed and analyzed. The average molecular weight significantly reduced as a result of ageing. The enlarged proportion of low molecular weight chains in the aged samples is consistent with the generation of degradation products produced by oxidative chain scission. Also E-beam materials have shown decreased tensile strength and elongation. Overall, this study demonstrated that the medical grade PEBA was significantly affected by radiation exposure over aging time, particularly at high irradiation doses. For medical use in case of radiation sterilization required, it is recommended to avoid Pebax material. If Pebax material must be in use for medical device, recommend to use alternate sterilization method such as Ethylene Oxide sterilization.

A System for Concurrent TMS-fMRI and Evaluation of Imaging Effects (동시 뇌경두개자기자극-기능자기공명영상 시행을 위한 홀더 제작과 시뮬레이션 및 영상 데이터 평가)

  • Kim, Jae-Chang;Kyeong, Sunghyon;Lee, Jong Doo;Park, Hae-Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.169-180
    • /
    • 2013
  • Purpose : The purpose of this study was to setup a concuurent transcranial magnetic stimulation (TMS)-functional MRI (fMRI) system for understanding causality of the functional brain network. Materials and Methods: We manufactured a TMS coil holder using nonmagnetic polyether ether ketone (PEEK). We simulated magnetic field distributions in the MR scanner according to TMS coil positions and angles. To minimize image distortions caused by TMS application, we controlled fMRI acquisition and TMS sequences to trigger TMS during inter-volume intervals. Results: Simulation showed that the magnetic field below the center of the coil was dramatically decreased with distance. Through the MR phantom study, we confirmed that TMS application around inter-volume acquisition time = 100 miliseconds reduced imaging distortion. Finally, the applicability of the concurrent TMS-fMRI was tested in preliminary studies with a healthy subject conducting a motor task within TMS-fMRI and passive motor movement induced by TMS in fMRI. Conclusion: In this study, we confirmed that the developed system allows use of TMS inside an fMRI system, which would contribute to the research of brain activation changes and causality in brain connectivity.

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

A STUDY OF THE NORMAL & ABNORMAL OCCULSAL PATERNS IN ADULTS USING THE SUPERIMPOSED RUBBER PATTERN METHOD (Superimposed Rubber Pattern법에 의한 성인 정상 및 비정상 교합자의 교합 양상에 관한 연구)

  • Choi, Dae-Gyun;Lee, Sung-Bok;Kwon, Young-Hyuk;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.467-491
    • /
    • 1995
  • In order to analyze the occlusin of intercuspation with maximun bite force, fifteen healthy adult subjects with the ages 23 to 27 were studied(Group1 ; 5-normal occlusion with Angle's Class1, Group2 ; 5-Angle's Class2 malocclusion, Group3 ; 5-Angle’s Class3 malocclusion). Head Position was fixed with occlusal plane paralleling to horizontal line and occlusal registration r cord was made with polyether rubber impression material(Ramitec, ESPECo. West Germany). After all subject were trained for maximum intercuspation at least 5 times, occlusal registration procedure was repeated for this study. Lower posterior rubber occlusal registration records were sliced with 1mm thickness using precision metal sliding channel(Hitachi Ind. Co., Japan). Gross sectional drawings were traced from occluding view of upper and lower posterior teeth on the rubber slices using digitizer, and superimposed for the determination of each drawing distance(Superimposed Rubber Pattern Method). Based on superimposed rubber pattern drawings, total area of occlusal view, sum of each area of the 5 divided occlusal contact provinces and its ratio, total area and number of occlusal contact area were determined to elucidate occlusal stability in the normal and abnormal occlusion groups. The data were analysed by t-test(p=0.05) to determine statistical significance. The obtained results were as follows : 1. Group1 showed the largest standard area with occlusal view of the lower posterior teeth and Group3 showed the smallest area. There was a significant difference between Group2 and Group3(p=0.025), and Gropu1 was not statistically different for both Group2 and Group3. 2. Means and ratio of the under 2.0mm area(D) and ratio showed $197.49mm^2$, 59.76% in Group1, $188,69mm^2$, 56.10% in Group2, and $174.23mm^2$, 55.76% in Group3. The results that Group1 has the most area/ratio and Group3 has the least area/ratio can be considered Group1 is the most advantageous for masticatory effective area, and Group3 is the least adnantageous. 3. Means and ratio of the under 1.0mm area(C) were $198.96mm^2$, 42.65% in Group1, 123.06$mm^2$, 46.58% in Group2, and $92.24mm^2$, 29.52% in Group3. These data means that Group1 is the most advantageous in terms of masticatory effective area and Group3 is the least. 4. Means and ratio of the under 0.5mm area(B) were $86.68mm^2$, 26.68% in Group1, $62.98mm^2$, 18.71% in Group2, and $36.44mm^2$, 11.66% in Group3. These can also be considered Group1 is the most advantageous for masticatory effective area and occlusal stability. 5. Means and ratio of the under 0.05mm area(A) were $30.92mm^2$, 9.21% in Group1, $14.31mm^2$, 4.25% in Group2, and $7.59mm^2$, 2.43% in Group3. The area ratio of the each subject group was(4.1) : (1.9) : (1)and the data of the under 0.05mm area has the intimate relationship with inter-group and intra-group data/ratio. 6. First molar showed the most occlusal contact points in all subject group and Group1 showed somewhat uniformly distributed occlusal contact point except first premolar. In Group2, all contact point in posterior teeth showed significantly reduced distribution except first molar. Group3 showed evenly distributed contace points in first and second molars.

  • PDF

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

An experimental study of dynamic frictional resistance between orthodontic bracket and arch wire (교정용 브라켓과 강선 사이의 운동마찰저항력에 관한 실험적 연구)

  • Lee, Jae-Hwan;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.31 no.4 s.87
    • /
    • pp.467-477
    • /
    • 2001
  • This investigation was designed to determine the effects of wire size, bracket width and the number of bracket on bracket-wire dynamic frictional resistance during simulating arch wire-guided tooth movement in vitro. For simulation of an arch wire-guided tooth movement, we simulated tooth, periodontal ligament and cancellous bone. Maxillary premolar and 1st molar were simulated as real sized resin teeth, the simulated resin teeth which its root was coated by polyether impression material which its elastic modulus is similar to periodontal ligament were embedded in steel housing with inlay wax which its elastic modulus is similar to cancellous bone. Stainless steel wires in four wire size (0.016, 0.018, $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch) were examined with respect to three (stainless steel) bracket widths (2.4, 3.0, 4.3mm) and the number of medium bracket(one, two, three) included in the experimental assembly under dry condition. The wires were ligated into the brackets with elastomeric module. The results were as follows : 1. In all the brackets, frictional resistance increased with increase in wire size. But, statistically similar levels of frictional resistance were observed between 0.018 inch and $0.016\;{\times}\;0.022$ inch wires in narrow bracket and also between 0.016 inch and 0.018 inch wire in wide backet. 2. The frictional forces produced by 0.016 inch wire were statistically similar levels in all the brackets. In 0.018 inch round wire, wide bracket was associated with lower amounts of friction than both narrow and medium brackets. In $0.016\;{\times}\;0.022,\;0.019\;{\times}\;0.025$ inch rectangular wire, wide bracket produced target friction than both narrow and medium brackets. In all the wirer, narrow and medium bracket demonstrated no statistical difference in levels of frictional resistance. 3. Frictional resistance increased with increase In number of medium bracket. 0.016 inch round wire demonstrated the greatest increment in frictional resistance, followed by $0.019\;{\times}\;0.025,\;0.016\;{\times}\;0.022$ inch rectangular wire which were similar level in increment of frictional resistance, 0.018 inch wire demonstrated the least increment. The increments of frictional resistance were not constantly direct proportion to number of bracket.

  • PDF

TENSILE BOND STRENGTH BETWEEN ELASTOMERIC IMPRESSION MATERIALS AND TRAY RESINS DEPENDING ON THE THICKNESS OF THE TRAY ADHESIVE

  • Kim, Tae-Won;Moon, Hong-Seok;Lee, Keun-Woo;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.699-711
    • /
    • 2006
  • Statement of problem. Elastomeric impression materials have been widely used to obtain an accurate impression. However there have not been enough studies on the influence of the thickness of the tray adhesives on the bonding strength between the trays and the elastomeric impression materials. Purpose. In order to understand the relationship between the thickness of the tray adhesive and the tensile bond strength and to suggest the thickness at which the bonding strength is strongest, tensile bond strength related to the thickness of adhesives of 3 different elastomeric impression materials were tested. Materials and methods. 3 impression materials, $Permlastic^{(R)}$. Regular Set(Kerr Corp., Romulus, Michigan, U.S.A.), $Impregum^{TM}$ $Penta^{TM}$(3M ESPE, Seefeld, Germany), and Aquasil Ultra Monophase Regular Set Smart Wetting.(Dentsply Caulk, Milford, Delaware, U.S.A.), were used in this study, and tray adhesives from the same manufacturers of the impression materials were used, which were Rubber Base Adhesive, Polyether Adhesive, and Silfix, respectively. The tray specimens were prepared by autopolymerizing the tray material(Instant Tray Mix, Lang, Wheeling, Illinois, U.S.A.), and a PVC pipe was used to house the impression material. In group A, tray adhesives were applied in multiple thin layers of 1 to 5 and in group B, adhesives were applied only once, in the thickness equivalent to several applications. Lightness($L^*$) of the adhesion surface was measured with a spectrophotometer(CM-3500d, Konica Minolta, Sakai, Osaka, Japan). The tensile bond strength of the elastomeric impression material and the tray resin was measured with universal materials testing machines(Instron, Model 3366, Instron Corp, Nowood, Massachusetts, U.S.A.). A formula between the number of adhesive application layers and the lightness of the adhesion surface was deduced in group A, and the number of adhesive layers in group B was estimated by applying the lightness($L^*$) to the deduced formula. Results. 1. In group A, a statistically significant increase in tensile bond strength appeared when the number of application layers increased from 1 to 2 and from 4 to 5, and no significant difference was present between 2, 3, and 4 layers in Permlastic. In Impregum, the tensile bond strength was significantly increased when the number of adhesive layers increased from 1 to 3, but no significant difference after 3 layers. In Aquasil, the tensile bond strength significantly increased as the number of application layers increased up to 4 but showed no significant difference between 4 and 5. 2. In group B, the tensile bond strength was decreased when the thickness of the adhesive increased in Permlastic. Impregum showed an increased tensile bond strength when the thickness of the adhesive was increased. In Aquasil, the tensile bond strength increased as the number of adhesive application layers increased up to approximately 2.5 layers but it sharply decreased after approximately 4.5. Conclusion. From the study, the common idea that it is better to apply a thin and single coat of tray adhesive needs correction in more detailed ways, and instructions on some of the tray adhesives should be reconsidered since there were several cases in which the tensile bond strength increased according to the increase in the thickness of the adhesives.

Influence of Coating Agent and Particle Size on the Soft Magnetic Properties of Fe Based Nano Crystalline Alloy Powder Core (철기(Fe Based) 나노결정질 합금 분말코어의 코팅제 및 입도가 연자기적 특성에 미치는 영향)

  • Jang, S.J.;Choi, Y.J.;Kim, S.W.;Jeon, B.S.;Lee, T.H.;Song, C.B.;Namkung, J.
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.3
    • /
    • pp.67-73
    • /
    • 2015
  • This is a basic research for improving soft magnetic property of Fe based nano crystalline alloy powder core. The main study is done around characteristics of permeability, core loss, and DC bias depending on amount of insulation coating agent and particle size. First, $Fe_{73.5}Si_{13.5}B_9Nb_3Cu_1$ amorphous alloy ribbon was fabricated by using the planar flow casting (PFC) device. Then, heat treatment and ball milling were done to obtain alloy powder. The amount of polyether imide (PEI) added to it was varied by 0.5, 1.0, 2.0, 2.5 wt% to have compression molding into $16ton/cm^2$. After going through crystalline heat treatment, the made toroidal nano crystalline powder core ($OD12.7mm^*ID7.62mm^*H4.75mm$) had smaller permeability as amount of insulation coating agent decreases. However, it was found out that core loss and DC bias characteristics have been improved. The reason for this results were expected to be because green density of power core decreases as amorphous alloy powder particles become smaller as amount of alloy powder insulation coating agent increases, it was determined that 1 wt% of insulation coating agent is appropriate. Also, for powder core made based on alloy powder size with amount of insulation coating agent fixed at 1 wt%, effective permeability and core loss were outstanding as particle size became bigger. However, characteristics of DC bias became worse as applied DC field increases. This is expected to be due to insulation effect, residual pores, or molding density of powder core resulting from thickness of coating on surface of alloy powder.

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.