• Title/Summary/Keyword: Poly (methyl methacrylate)

Search Result 338, Processing Time 0.027 seconds

In-situ Observations of Gas Phase Dynamics During Graphene Growth Using Solid-State Carbon Sources

  • Kwon, Tae-Yang;Kwak, Jinsung;Chu, Jae Hwan;Choi, Jae-Kyung;Lee, Mi-Sun;Kim, Sung Youb;Shin, Hyung-Joon;Park, Kibog;Park, Jang-Ung;Kwon, Soon-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.131-131
    • /
    • 2013
  • A single-layer graphene has been uniformly grown on a Cu surface at elevated temperatures by thermally processing a poly(methyl methacrylate) (PMMA) film in a rapid thermal annealing (RTA) system under vacuum. The detailed chemistry of the transition from solid-state carbon to graphene on the catalytic Cu surface was investigated by performing in-situ residual gas analysis while PMMA/Cu-foil samples being heated, in conjunction with interrupted growth studies to reconstruct ex-situ the heating process. The data clearly show that the formation of graphene occurs with hydrocarbon molecules vaporized from PMMA, such as methane and/or methyl radicals, as precursors rather than by the direct graphitization of solid-state carbon. We also found that the temperature for vaporizing hydrocarbon molecules from PMMA and the length of time the gaseous hydrocarbon atmosphere is maintained, which are dependent on both the heating temperature profile and the amount of a solid carbon feedstock are the dominant factors to determine the crystalline quality of the resulting graphene film. Under optimal growth conditions, the PMMA-derived graphene was found to have a carrier (hole) mobility as high as ~2,700 cm2V-1s-1 at room temperature, superior to common graphene converted from solid carbon.

  • PDF

Fabrication of functional nanoparticles by layer-by-layer self-assembly method (LBL 법을 이용한 기능성 나노 입자 제조)

  • Kim, Jin-Ho;Hwang, Jong-Hee;Lim, Tae-Young;Kim, Sae-Hoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.6
    • /
    • pp.305-310
    • /
    • 2009
  • $TiO_2$ thin films consisting of positively charged poly (diallyldimethylammonium chloride) (PDDA) and negatively charged titanium (IV) bis (ammonium lactato) dihydroxide (TALH) were successfully fabricated on a poly (methyl methacrylate) (PMMA) by layer-by-layer (LBL) self-assembly method. By the measurement of quartz crystal microbalance (QCM), it was found that as the solution pH of TALH decreased, the deposition volume of TALH increased and the thickness of (PDDA/TALH) thin film coated on the surface of PMMA particles increased. The PMMA particles coated with the coating sequence of (PDDA/TALH)n showed the variation of color changes as a function of the number of bilayer. The number of bilayer (n) of (PDDA/TALH) thin films was 10 and 20, the values of $a^*$ and $b^*$ decreased from those of PMMA particles without coating films and the color changes was shifted to green and blue direction in the $a^*$, $b^*$ chromaticity diagram. And then, the number of n increased to 30 and 40, the values of $a^*$ and $b^*$ increased and the color changes was shifted to red and yellow direction, respectively. Finally the PMMA particles coated with $(PDDA/TALH)_{50}$ thin film showed a little same value of $a^*$ and $b^*$ with the PMMA particles without (PDDA/TALH) thin film.

A Study on Heat Dissipation Characteristics of PMMA Composite Films with Phase Change Material (상변화물질을 이용한 PMMA 복합필름의 방열 성능 향상에 관한 연구)

  • Kwon, Junhyuk;Yoon, Bumyong;Cho, Seung-hyun;Lee, Stephanie K.;Kim, Hyung-ick;Kim, Donghyun;Park, Kyungui;Suhr, Jonghwan
    • Composites Research
    • /
    • v.30 no.5
    • /
    • pp.288-296
    • /
    • 2017
  • The focus of this study is to experimentally investigate the heat dissipation characteristics of poly (methyl methacrylate) (PMMA) composite films with phase change materials (PCM) to resolve heat build-up problems encountered in various electronic devices. In this study, two different types of phase change materials were used to fabricate the composite films by compression molding method and PCM paste sealing method then compared. It was observed in this study that the heat dissipation capability of PCM/PMMA composite films was remarkably enhanced by applying graphite sheet or graphene film into the composite due to their high thermal conductivity. These PCM/ PMMA composite films were attached on the hot spot inside smart phone and tested its surface temperature change according to time. The heat dissipation capability of PCM/PMMA composite film incorporated smart phone was increased 154% and hybrid PCM/PMMA composite film incorporated smart phone was increased 286% over the reference, respectively.

Effects of Oxyfluorinated Graphene Oxide Flake on Mechanical Properties of PMMA Artificial Marbles (함산소불소화 처리된 그래핀 산화물 플레이크가 PMMA 인조대리석의 기계적 물성에 미치는 영향)

  • Kim, Hyo-Chul;Jeon, Son-Yeo;Kim, Hyung-Il;Lee, Young-Seak;Hong, Min-Hyuk;Choi, Ki-Seop
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.251-261
    • /
    • 2012
  • The nanocomposites containing graphene oxide flakes were prepared in order to improve the mechanical properties of artificial marbles based on poly(methyl methacrylate)(PMMA) matrix. Graphene oxide flakes were prepared from graphite by oxidation with Hummers method followed by exfoliation with thermal treatment. Surface of graphene oxide flakes were modified with oxyfluorination in various oxygene:fluorine compositions to improve the interfacial compatibility. The nanocomposites containing graphenes modified with oxyfluorination in the oxygen content of 50% and higher showed the significant increase in flexural strength, flexural modulus, Rockwell hardness, Barcol hardness, and Izod impact strength. The morphology of fractured surface showed the improved interfacial adhesion between PMMA matrix and the graphenes which were properly treated with oxyfluorination. The mechanical properties of nanocomposite were deteriorated by increasing the content of graphene above 0.07 phr due to the nonuniform dispersion of graphenes.

Fluorination of Polymethylmethacrylate (PMMA) Film and Its Surface Characterization (폴리메틸메타아크릴레이트(PMMA) 필름의 불소화 및 그 표면특성)

  • Jung, Min-Jung;Lim, Jae-Won;Park, In-Jun;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.317-322
    • /
    • 2010
  • In this study, poly(methyl methacrylate) (PMMA) was treated with changing mixing ratios of $F_2$ and $O_2$ using oxyfluorination method for hydrophilic modification of PMMA film. For the characterizations of oxyfluorinated PMMA surface, contact angle, surface free energy, X-ray photoelectron spectroscopy (XPS) and optical transmittance (UV-vis) were carried out. After the oxyfluorination, PMMA surface became more hydrophilic showing the decrease of water contact angle from $69^{\circ}$ to $44^{\circ}$. So, surface free energy of oxyfluorinated PMMA film was increased from 46 to $58\;mN\;m^{-1}$. These results are attributed to hydrophilic functional groups such as hydroxyl group formed oxyfluorination method on the PMMA surface. From XPS results, it was confirmed that O/C concentration ratio on the surface of PMMA was increased, the amount of C-OH bonding which shows hydrophilicity was also largely increased from 6.7 to 24.8% with increasing fluorine partial-pressure via the oxyfluorination, The oxyfluorination conditions, room temperature, 1 bar with one mixture ratio of $F_2$ to $O_2$ had little influence on optical transmittance properties of PMMA film but enhanced its surface hydrophilicity. This result suggests that oxyfluorination method could be useful to change hydrophobic PMMA surface to hydrophilic.

Fabrication and Characterization of UV-curable Conductive Transparent Film with Polyaniline Nanofibers (폴리아닐린 나노섬유를 이용한 광경화형 전도성 투명필름의 제조 및 특성)

  • Kim, Sung-Hyun;Song, Ki-Gook
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.531-535
    • /
    • 2012
  • Conductive polyaniline (PANI) nanofibers in UV-curable resin were used for a transparent conductive film. The emeraldine-salt PANI (ES-PANI) nanofibers were prepared by chemical oxidation polymerization of aniline, which could be changed into emeraldine-base PANI by dedoping. EB-PANI nanofibers as a precursor for conductive fillers were thereby transformed into re-dpoed PANI (rES-PANI) by dodecylbenzenesulfonic acid in the UV-curable resin solution. rES-PANI nanofibers have high conductivity and long-term stability in the solution without a defect of nanostructure. The resulting conductive resin solution was proved to be highly stable where no precipitation of rES-PANI fillers was observed over a period of 3 months. The transparent film was spin-casted on a poly(methyl methacrylate) sheet of thickness ca. $5{\mu}m$. A surface resistance of $6.5{\times}10^8{\Omega}/sq$ and transmittance at 550 nm of 91.1% were obtained for the film prepared with a concentration of 1.4 wt% rES-PANI nanofibers in the solution. This transformation process of rES-PANI from ES-PANI by dedoping-redoping can be an alternative method for the preparation of an antistatic protection film with controllable surface resistance and optical transparencies with the PANI concentration in UV-curable solution.

Pelvic Symphyseal Distraction Osteotomy for Constipation Management Secondary to Pelvic Stenosis (골반강 협착증으로 인해 발생한 변비를 가진 고양이에서의 골반강 확장술을 이용한 치료 증례)

  • Oh, Kwang-Seon;Choi, Sung-Jin;Kim, Nam-Soo;Kim, Min-Su;Lee, Ki-Chang;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.527-530
    • /
    • 2014
  • A 7-year-old neutered male Korean domestic short-haired cat was referred to our clinic to treat constipation which had persisted for 6 months. The rectal examination revealed narrowing of the right lateral portion of the pelvic canal. A reduced pelvic canal diameter by pelvic fracture malunion was revealed on radiography. The pelvic canal diameter ratio measured from preoperative was 0.68. Based on rectal and radiographic examinations, constipation caused by pelvic canal narrowing was confirmed. Pelvic symphyseal distraction-osteotomy and iliac wedge osteotomy were performed. An iliac osteotomy of the ilium was performed to ease the pelvic symphyseal distraction. After the symphysis was split longitudinally, pelvic symphyseal distraction was maintained by using a spacer made of poly-methyl-methacrylate. The osteotomy of the ilium was fixed using a bone plate and screws. Increased pelvic canal diameter was confirmed on post-operative radiography and the postoperative pelvic canal diameter ratio was 0.91. The patient received antibiotics, NSAIDs, crystalloids and Lactulose for post-operative care. The cat recovered normal defecation abilities and did not have constipation at one week postoperatively. No episodes of constipation persisting longer than 6 months have been reported by owners in previous studies. Pelvic symphyseal distraction osteotomy and iliac wedge osteotomy may prove to be a useful surgical procedure to treat pelvic canal stenosis that is caused by pelvic fracture malunion.

The Effect of Water Immersion on the Surface Strength and the Flexural Strength of the Acrylic Resin for Occlusal Appliances (교합장치용 아크릴레진의 표면경도와 굴곡강도에 대한 침수의 영향)

  • Lee, Hoy-Youn;Im, Yeong-Gwan;Kim, Byung-Gook;Lim, Hoi-Soon;Kim, Jae-Hyung
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.1
    • /
    • pp.75-81
    • /
    • 2010
  • By repeating nocturnal bruxism occlusal appliance's wearing condition that is used to cure temporomandibular disorders into the vitro experiment, research aims to find out how moisture infiltrated and drying cycle process affects on the surface microhardness of the resin for occlusal appliance and flexural strength. By utilizing resin for occlusal appliance which is the main component of poly methyl methacrylate, bar shaped sample was produced. For the resin sample utilized as the controlled group 1, the sample was infiltrated in the moisture for 7 days in the temperature of 37C. Then, the resin sample of the controlled group 2 was maintained in a dry condition for 7 days in the normal temperature. After that, each sample's surface microhardness and flexural strength were measured. For the resin sample that is utilized as the experimental sample, the sample was infiltrated in the moisture for 7 days in the temperature of 37C. Then, it was inundated for 8 hours a day and dried in the normal temperature for 16 hours with the continuous process of moisture infiltration and dry cycle process for 30 days. During this cycle process, sample's surface and flexural strength were measured in the 1st day, 7th day, and 30th day. Then, it was statistically analyzed to find out the difference of controlled and experiment group's surface microhardness and flexural strength. Results are 1. For the experimental and controlled group's surface microhardness of the resin for the occlusal appliance, it did not show any significant differences after moisture infiltration and dry cycle process repetition. 2. In case of the flexural strength for resin for the occlusal appliance, experimental group with moisture infiltration and dry cycle for 30 day process had greater effect than the experimental group at the 1st day and controlled group These results can be considered to be utilized from the patients of the temporomandibular disorders towards occlusal appliance used and maintained method.