• Title/Summary/Keyword: Pollution variable

Search Result 145, Processing Time 0.027 seconds

Modeling of a Compressed Air Energy Electrification by Using Induction Generator Based on Field Oriented Control Principle

  • Vongmanee, Varin;Monyakul, Veerapol
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1511-1519
    • /
    • 2014
  • The objective of this paper is to propose a modelling of a small compressed air energy storage system, which drives an induction generator based on a field-oriented control (FOC) principle for a renewable power generation. The proposed system is a hybrid technology of energy storage and electrification, which is developed to use as a small scale of renewable energy power plant. The energy will be transferred from the renewable energy resource to the compressed air energy by reciprocating air compressor to be stored in a pressurized vessel. The energy storage system uses a small compressed air energy storage system, developed as a small unit and installed above ground to avoid site limitation as same as the conventional CAES does. Therefore, it is suitable to be placed at any location. The system is operated in low pressure not more than 15 bar, so, it easy to available component in country and inexpensive. The power generation uses a variable speed induction generator (IG). The relationship of pressure and air flow of the compressed air, which varies continuously during the discharge of compressed air to drive the generator, is considered as a control command. As a result, the generator generates power in wide speed range. Unlike the conventional CAES that used gas turbine, this system does not have any combustion units. Thus, the system does not burn fuel and exhaust pollution. This paper expresses the modelling, thermodynamic analysis simulation and experiment to obtain the characteristic and performance of a new concept of a small compressed air energy storage power plant, which can be helpful in system designing of renewable energy electrification. The system was tested under a range of expansion pressure ratios in order to determine its characteristics and performance. The efficiency of expansion air of 49.34% is calculated, while the efficiency of generator of 60.85% is examined. The overall efficiency of system of approximately 30% is also investigated.

Characteristics Analysis of CVT with Built-in Crank for Bicycle (자전거용 크랭크 일체형 자동변속기에 대한 특성 해석)

  • Baek, Seung-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.963-969
    • /
    • 2015
  • Bicycle is one of the most popular mode of transport due to the increase of interest in the well-being and environment pollution. Before fabricating a continuously variable transmission that is applied to the actual bicycle, for reducing the problems in the early stage, the reliable simulation program has been applied and the financial problem can be solved. In this paper, in order to confirm the design factor, the stress analysis has been applied. In all models, each link and the joint portion are assumed to be a major design factors, and impact of each link and joints received stress during the operation and it is confirmed by using the CAE. Also, for the analysis region, the special code has been developed to calculate pulsation phenomenon through appropriate mathematical modeling.

Analysis of pollutant build-up model applied to various urban landuse

  • Choi, Jiyeon;Na, Eunhye;Ryu, Jichul;Kim, Jinsun;Kim, Hongtae;Shin, Dongsuk
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.13-17
    • /
    • 2019
  • This study was conducted to analyse the application of pollutant build-up model on various urban landuses and to characterize pollutant build-up on urban areas as a source of stormwater runoff pollution. The monitored data from impervious surfaces in urban areas such as commercial (8 sites), industrial (10 sites), road (8 sites), residential (10 sites), recreational (5 sites) from 2008 to 2016 were used for the analysis of pollutant build-up model. Based on the results, the average runoff coefficients vary from 0.35 to 0.61. In all landuses except recreational landuse, the runoff coefficient is 0.5 or more, which is the highest in the commercial area. Commercial landuse where pollutants occur at the highest EMC in all landuse, and it is considered that NPS management is necessary compared with other landuses. The maximum build-up load for organic matter (BOD) was highest in the commercial area ($4.59g/m^2$), and for particular matter (TSS) in the road area ($5.90g/m^2$) while for nutrient (TN and TP) in the residential area ($0.40g/m^2$, $0.14g/m^2$). The rate constants ranged from 0.1 to 1.3 1/day depending on landuse and pollutant parameters, which means that pollutant accumulation occurs between 1 and 10 days during dry day. It is clear that these build-up curves can generally be classified based on landuse. Antecedent dry day (ADD) is a suitable and reasonable variable for developing pollutant build-up functions. The pollutant build-up curves for different landuse shows that these build-up curves can be generally categorized based on landuse.

Tomographic Imaging for Structural Health Monitoring Inspection of Containment Liner Plates using Guided Ultrasonic (유도초음파를 활용한 격납건물 라이너 플레이트 상시감시 모니터링 검사를 위한 토모그래피 영상화)

  • Park, Junpil;Cho, Younho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 2020
  • Large-scale industrial facility structures continue to deteriorate due to the effects of operating and environmental conditions. The problems of these industrial facilities are potentially causing economic losses, environmental pollution, casualties, and national losses. Accordingly, in order to prevent disaster accidents of large structures in advance, the necessity of diagnosing structures using non-destructive inspection techniques is being highlighted. The defect occurrence, location and defect type of the structure are important parameters for predicting the remaining life of the structure, so continuous defect observation is very important. Recently, many researchers have been actively researching real-time monitoring technology to solve these problems. Structure Health Monitoring Inspection is a technology that can identify and respond to the occurrence of defects in real time, but there is a limit to check the degree of defects and the direction of growth of defects. In order to compensate for the shortcomings of these technologies, the importance of defect imaging techniques is emerging, and in order to find defects in large structures, a method of inspecting a wide range using guided ultrasonic is effective. The work presented here introduces a calculation for the shape factor for evaluation of the damaged area, as well as a variable β parameter technique to correct a damaged shape. Also, we perform research in modeling simulation and an experiment for comparison with a suggested inspection method and verify its validity. The curved structure image obtained by the advanced RAPID algorithm showed a good match between the defect area and the shape.

Evaluation of the Removal Performance of Nitrogen Oxides of Foam Composites Using Activated Carbon and Titanium Dioxide (활성탄소와 이산화 타이타늄을 활용한 폼 복합체의 질소산화물의 제거 성능 평가)

  • Choi, Hyun-Chul;Choi, Young-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.120-127
    • /
    • 2022
  • Nitrogen oxide(NOx) is a major cause of air pollution, exists in the form of nitrogen monoxide and nitrogen dioxide, and is harmful to the human body. Recently, a number of studies to reduce NOx in the atmosphere have been conducted, and these efforts have been the same in the field of construction materials. It is known that NOx can be efficiently removed by using a photocatalytic reaction. In this study, the NOx removal performance of the foam composite using activated carbon(AC) and titanium dioxide(TiO2) was investigated. AC was used to enhance the photocatalytic reaction of TiO2 by increasing the internal specific surface area of the foam composite. In this study, foam composites were prepared using the substitution rate of AC as the main variable. The NOx removal performance of specimen was evaluated according to the test method presented in ISO-22197-1. The specific surface area of the foam composite showed a tendency to increase according to the AC content, but decreased at 15% or more. Also, when the AC substitution rate was 15%, the NOx removal efficiency was the highest.

Associations Between Indoor Air Pollutants and Risk Factors for Acute Respiratory Infection Symptoms in Children Under 5: An Analysis of Data From the Indonesia Demographic Health Survey

  • Ichtiarini Nurullita Santri;Yuniar Wardani;Yohane Vincent Abero Phiri;Gunchmaa Nyam;Tyas Aisyah Putri;Khoiriyah Isni;Dyah Suryani;Grace Sambo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.56 no.3
    • /
    • pp.255-263
    • /
    • 2023
  • Objectives: The study investigated the association between indoor air pollution (IAP) and risk factors for acute respiratory infection (ARI) symptoms in children under 5 years of age. Methods: A cross-sectional study was conducted using data derived from Indonesia Demographic and Health Survey in 2017. Binary logistic regression modeling was employed to examine each predictor variable associated with ARI among children under 5 years of age in Indonesia. Results: The study included a total of 4936 households with children. Among children under 5 years old, 7.2% reported ARI symptoms. The presence of ARI symptoms was significantly associated with the type of residence, wealth index, and father's smoking frequency, which were considered the sample's socio-demographic characteristics. In the final model, living in rural areas, having a high wealth index, the father's smoking frequency, and a low education level were all linked to ARI symptoms. Conclusions: The results revealed that households in rural areas had a substantially higher level of reported ARI symptoms among children under 5 years old. Furthermore, the father's smoking frequency and low education level were associated with ARI symptoms.

Effects of Thermal Wastewater Effluent and Hydrogen Ion Potential (pH) on Water Quality and Periphyton Biomass in a Small Stream (Buso) of Pocheon Area, Korea (포천지역 계류 (부소천)의 수질과 부착조류 생물량에 온배수와 수소이온농도 (pH) 영향)

  • Jeon, Gyeonghye;Eum, Hyun Soo;Jung, Jinho;Hwang, Soon-Jin;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.1
    • /
    • pp.96-115
    • /
    • 2017
  • Understanding effects of thermal pollution and acidification has long been a concern of aquatic ecologists, but it remains largely unknown in Korea. This study was performed to elucidate the effects of thermal wastewater effluent (TWE) and acid rain on water quality and attached algae in a small mountain stream, the Buso Stream, a tributary located in the Hantan River basin. A total of five study sites were selected in the upstream area including the inflowing point of hot-spring wastewater (HSW), one upstream site (BSU), and three sites below thermal effluent merged into the stream (1 m, 10 m and 300 m for BSD1, BSD2, and BSD3, respectively). Field surveys and laboratory analyses were carried out every month from December 2015 to September 2016. Water temperature ranged $1.7{\sim}28.8^{\circ}C$ with a mean of $15.0^{\circ}C$ among all sites. Due to the effect of thermal effluent, water temperature at HSW site was sustained at high level during the study period from $17.5^{\circ}C$ (January) to $28.8^{\circ}C$ (September) with a mean of $24.2{\pm}3.7^{\circ}C$, which was significantly higher than other sites. Thermal wastewater effluent also brought in high concentration of nutrients(N, P). The effect of TWE was particularly apparent during dry season and low temperature period (December~March). Temperature effect of TWE did not last toward downstream, while nutrient effect seemed to maintain in longer distance. pH ranged 5.1~8.4 with a mean of 6.9 among all sites during the study period. The pH decrease was attributed to seasonal acid rain and snow fall, and their effects was identified by acidophilic diatoms dominated mainly by Eunotia pectinalis and Tabellaria flocculosa during March and August. These findings indicated that water quality and periphyton assemblages in the upstream region of Buso Stream were affected by thermal pollution, eutrophication, and acidification, and their confounding effects were seasonally variable.

Exposure Assessment and Asbestosis Pulmonum among Inhabitants near Abandoned Asbestos Mines Using Deposited Dust (폐석면광산 주변 지역의 주택 침적먼지의 석면 검출과 석면폐증의 관련성)

  • Ahn, Hoki;Yang, Wonho;Hwangbo, Young;Lee, Yong Jin
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.369-379
    • /
    • 2015
  • Objectives: The lack of reliable information on environmental pollution and health impacts related to asbestos contamination from abandoned mines has drawn attention to the need for a community health study. This study was performed to evaluate asbestos-related health symptoms among residents near abandoned asbestos mines located in the Chungcheong Provinces. In addition, exposure assessment for asbestos is needed although the exposure to asbestos was in the past. Methods: Past exposure to asbestos among inhabitants near abandoned asbestos mines was estimated by using surface sampling of deposited dust in indoor and outdoor residences. A total of 54 participants were divided into two groups with (34 cases) and without (20 controls) diseases related to asbestos. Surface sampling of deposited dust was carried out in indoor and outdoor residences by collecting 105 samples. Deposited dust for sampling was analyzed by polarization microscope (PLM) and scanning electron microscope?energy dispersive x-ray spectrometer (SEM-EDX) to detect asbestos. Subsequently, the elements of the deposited dust with asbestos were analyzed by SEM-EDX to assess the contribution of sources such as abandoned mines, slate and soil. Results: Among the 105 samples, asbestos was detected by PLM in 29 (27.6%) sampling points, and detected by SEM in 56 (48.6%) sampling points. Asbestos in indoor residences was detected by PLM in four sampling points, and by SEM in 12 sampling points. Asbestos detection in indoor residences may be due to ventilation between indoors and outdoors, and indicates long-term exposure. The asbestos detection rate for outdoor residences in the case group was higher than that in the control group. This can be explained as the case group having had higher exposure to asbestos, and there has been continuous exposure to asbestos in the control group as well as the case group. Conclusion: Past residential asbestos exposure may be associated with asbestosis among local residents near abandoned asbestos mines. Odds ratios were calculated for asbestos detection in outdoor residence by logistic regression analysis. Odds ratio between asbestos detection and asbestosis pulmonum was 3.36 (95% CI 0.90-12.53) (p=0.072), adjusting for age, sex, smoking status and work history with multi-variable logistic regression by PLM analysis method.

Effect of Application Methods for Liquid Pig Slurry on Growth and Yield of Rice(Oryza sativa L.) (가축 액상분뇨의 시용방법이 벼의 생육과 수량에 미치는 영향)

  • Ryoo J. W;Hong M. Z.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.75-80
    • /
    • 2004
  • Field experiments were conducted in 2002 on sandy loam soil under variable fertilizer management; swine slurry and chemical fertilizer. The effect of different fertilizer management and application method on the growth characteristics and yield of rice were determined. The rice was planted to examine the effect of swine slurry on the crop growth. As slurry manure was fertilized, yield of each group of rice was decreased from 3 to $5\%$. In conclusion, basal application of slurry was maintained productivity of rice, but to improve of productivity of rice, the rice should be fertilized with the basal application of animal slurry and supplementary application of chemical fertilizer. The results indicates that application of animal slurry improves quality of rice rather quantity, which means grain yield. Rice quality of the slurry+chemical and the slurry were significantly better than that of the chemical fertilizer. That indicates application of animal slurry could improve rice quality. Application of animal slurry seemingly has potentials for reducing pollution of animal slurry and improving environment of rural area as well as producing high-quality rice.

  • PDF

An Analysis of the Impacts of FDI Types on CO2 Emissions - Focus on Scale Effects and Technique Effects - (FDI 유형별 CO2 배출량에 미치는 영향 분석 - 규모효과와 기술효과를 중심으로 -)

  • Hwang, Yun-Seop;Park, Junghoon;Lee, Sang Whi
    • International Commerce and Information Review
    • /
    • v.17 no.3
    • /
    • pp.379-402
    • /
    • 2015
  • The purpose of this study is to determine whether there is a significant difference in impacts decomposed into scale effects and technique effects on $CO_2$ emissions between Greenfield FDI and M&A FDI flows into Korean manufacturing sectors, ultimately leading to clarify the relationship between FDI and environmental pollution. To this end, the research constructed a simultaneous model to analyze coincidental relationship of influence and interactions between each variable. Archival data, spanning the 15 years period from 1995 to 2009, is industry-level panel data on 13 Korean manufacturing sectors, and it is empirically analyzed with three-stage least squares (3SLS) method. Key findings can be summarized into two parts. First of all, Greenfield FDI has a greater impact on increasing industrial gross output, resulting in more $CO_2$ emissions than M&A FDI through scale effects. Secondly, technique effects of FDI have a bigger impact on $CO_2$ emissions than scale effects, implying that this inflow of FDI into Korea contributes positively to the reduction of $CO_2$ emissions. These findings are expected to play a meaningful role in establishing FDI policies with consideration of the environment by giving the implication that different incentives for each FDI type should be considered to maximize the effect of environmental protection.

  • PDF