• 제목/요약/키워드: Pollution variable

검색결과 145건 처리시간 0.023초

Modeling of a Compressed Air Energy Electrification by Using Induction Generator Based on Field Oriented Control Principle

  • Vongmanee, Varin;Monyakul, Veerapol
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1511-1519
    • /
    • 2014
  • The objective of this paper is to propose a modelling of a small compressed air energy storage system, which drives an induction generator based on a field-oriented control (FOC) principle for a renewable power generation. The proposed system is a hybrid technology of energy storage and electrification, which is developed to use as a small scale of renewable energy power plant. The energy will be transferred from the renewable energy resource to the compressed air energy by reciprocating air compressor to be stored in a pressurized vessel. The energy storage system uses a small compressed air energy storage system, developed as a small unit and installed above ground to avoid site limitation as same as the conventional CAES does. Therefore, it is suitable to be placed at any location. The system is operated in low pressure not more than 15 bar, so, it easy to available component in country and inexpensive. The power generation uses a variable speed induction generator (IG). The relationship of pressure and air flow of the compressed air, which varies continuously during the discharge of compressed air to drive the generator, is considered as a control command. As a result, the generator generates power in wide speed range. Unlike the conventional CAES that used gas turbine, this system does not have any combustion units. Thus, the system does not burn fuel and exhaust pollution. This paper expresses the modelling, thermodynamic analysis simulation and experiment to obtain the characteristic and performance of a new concept of a small compressed air energy storage power plant, which can be helpful in system designing of renewable energy electrification. The system was tested under a range of expansion pressure ratios in order to determine its characteristics and performance. The efficiency of expansion air of 49.34% is calculated, while the efficiency of generator of 60.85% is examined. The overall efficiency of system of approximately 30% is also investigated.

자전거용 크랭크 일체형 자동변속기에 대한 특성 해석 (Characteristics Analysis of CVT with Built-in Crank for Bicycle)

  • 백승엽
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.963-969
    • /
    • 2015
  • 자전거는 환경공해 능력과 웰빙에 대한 관심증가 때문에 가장 유망한 미래 교통수단 중의 하나이다. 실제 자전거에 적용될 무단변속기를 제작하기 전에 신뢰성이 확보된 시뮬레이션 프로그램을 통하여 문제점을 초기에 확인하고, 각 링크의 소재 및 두께 등의 설계인자 최적화와 능력을 평가할 필요가 있다. 이 같은 과정을 통하여 무단 변속기 시스템 설계 과정에서의 소요비용을 줄일 수 있다. 본 논문에서는 설계인자를 확정하기 위해 응력해석을 수행되었으며. 전체 모델링 중에서 각 링크와 조인트 부분을 주요 설계인자로 가정하고 각각의 링크 및 조인트의 영향도 및 작동 시 받은 응력들을 CAE를 통해 확인하였다. 또한, 해석 영역에 대하여 적절한 수학적 모델링을 통해 맥동 현상을 계산할 수 있는 전용 code를 개발하였으며, 이를 Matlab에 적용하여 해석 결과를 graphic화하여 분석하였다.

Analysis of pollutant build-up model applied to various urban landuse

  • Choi, Jiyeon;Na, Eunhye;Ryu, Jichul;Kim, Jinsun;Kim, Hongtae;Shin, Dongsuk
    • Membrane and Water Treatment
    • /
    • 제10권1호
    • /
    • pp.13-17
    • /
    • 2019
  • This study was conducted to analyse the application of pollutant build-up model on various urban landuses and to characterize pollutant build-up on urban areas as a source of stormwater runoff pollution. The monitored data from impervious surfaces in urban areas such as commercial (8 sites), industrial (10 sites), road (8 sites), residential (10 sites), recreational (5 sites) from 2008 to 2016 were used for the analysis of pollutant build-up model. Based on the results, the average runoff coefficients vary from 0.35 to 0.61. In all landuses except recreational landuse, the runoff coefficient is 0.5 or more, which is the highest in the commercial area. Commercial landuse where pollutants occur at the highest EMC in all landuse, and it is considered that NPS management is necessary compared with other landuses. The maximum build-up load for organic matter (BOD) was highest in the commercial area ($4.59g/m^2$), and for particular matter (TSS) in the road area ($5.90g/m^2$) while for nutrient (TN and TP) in the residential area ($0.40g/m^2$, $0.14g/m^2$). The rate constants ranged from 0.1 to 1.3 1/day depending on landuse and pollutant parameters, which means that pollutant accumulation occurs between 1 and 10 days during dry day. It is clear that these build-up curves can generally be classified based on landuse. Antecedent dry day (ADD) is a suitable and reasonable variable for developing pollutant build-up functions. The pollutant build-up curves for different landuse shows that these build-up curves can be generally categorized based on landuse.

유도초음파를 활용한 격납건물 라이너 플레이트 상시감시 모니터링 검사를 위한 토모그래피 영상화 (Tomographic Imaging for Structural Health Monitoring Inspection of Containment Liner Plates using Guided Ultrasonic)

  • 박준필;조윤호
    • 한국압력기기공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.1-9
    • /
    • 2020
  • Large-scale industrial facility structures continue to deteriorate due to the effects of operating and environmental conditions. The problems of these industrial facilities are potentially causing economic losses, environmental pollution, casualties, and national losses. Accordingly, in order to prevent disaster accidents of large structures in advance, the necessity of diagnosing structures using non-destructive inspection techniques is being highlighted. The defect occurrence, location and defect type of the structure are important parameters for predicting the remaining life of the structure, so continuous defect observation is very important. Recently, many researchers have been actively researching real-time monitoring technology to solve these problems. Structure Health Monitoring Inspection is a technology that can identify and respond to the occurrence of defects in real time, but there is a limit to check the degree of defects and the direction of growth of defects. In order to compensate for the shortcomings of these technologies, the importance of defect imaging techniques is emerging, and in order to find defects in large structures, a method of inspecting a wide range using guided ultrasonic is effective. The work presented here introduces a calculation for the shape factor for evaluation of the damaged area, as well as a variable β parameter technique to correct a damaged shape. Also, we perform research in modeling simulation and an experiment for comparison with a suggested inspection method and verify its validity. The curved structure image obtained by the advanced RAPID algorithm showed a good match between the defect area and the shape.

활성탄소와 이산화 타이타늄을 활용한 폼 복합체의 질소산화물의 제거 성능 평가 (Evaluation of the Removal Performance of Nitrogen Oxides of Foam Composites Using Activated Carbon and Titanium Dioxide)

  • 최현철;최영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.120-127
    • /
    • 2022
  • 질소산화물(NOx)은 대기오염의 주요 인자로 일산화질소와 이산화질소의 형태로 존재하며 인체에 유해하다. 최근 대기 중 NOx를 제거하기 위한 많은 연구가 진행되고 있으며, 이러한 노력은 건설재료 분야에서도 동일하다. NOx는 광촉매 반응을 이용하여 효율적으로 제거할 수 있는 것으로 알려져 있다. 본 연구에서는 활성탄(AC)과 이산화타이타늄(TiO2)을 이용한 폼 복합재의 NOx 제거성능을 조사하였다. AC는 폼 복합체의 비표면적을 증가시켜 TiO2의 광촉매 반응 효율을 향상시켰다. 본 연구에서는 AC의 혼합율을 주요 변수로 하여 폼 복합체를 제조하였다. 제조된 시험체를 이용하여 ISO-22197-1에 제시된 시험방법에 따라 NOx 제거성능을 평가하였다. 폼 복합체의 비표면적은 AC 함량에 따라 증가하는 경향을 나타내었으나 15% 이상에서는 감소하였다. 또한 AC 혼입률이 15%일 때 NOx 제거 효율이 가장 높았다.

Associations Between Indoor Air Pollutants and Risk Factors for Acute Respiratory Infection Symptoms in Children Under 5: An Analysis of Data From the Indonesia Demographic Health Survey

  • Ichtiarini Nurullita Santri;Yuniar Wardani;Yohane Vincent Abero Phiri;Gunchmaa Nyam;Tyas Aisyah Putri;Khoiriyah Isni;Dyah Suryani;Grace Sambo
    • Journal of Preventive Medicine and Public Health
    • /
    • 제56권3호
    • /
    • pp.255-263
    • /
    • 2023
  • Objectives: The study investigated the association between indoor air pollution (IAP) and risk factors for acute respiratory infection (ARI) symptoms in children under 5 years of age. Methods: A cross-sectional study was conducted using data derived from Indonesia Demographic and Health Survey in 2017. Binary logistic regression modeling was employed to examine each predictor variable associated with ARI among children under 5 years of age in Indonesia. Results: The study included a total of 4936 households with children. Among children under 5 years old, 7.2% reported ARI symptoms. The presence of ARI symptoms was significantly associated with the type of residence, wealth index, and father's smoking frequency, which were considered the sample's socio-demographic characteristics. In the final model, living in rural areas, having a high wealth index, the father's smoking frequency, and a low education level were all linked to ARI symptoms. Conclusions: The results revealed that households in rural areas had a substantially higher level of reported ARI symptoms among children under 5 years old. Furthermore, the father's smoking frequency and low education level were associated with ARI symptoms.

포천지역 계류 (부소천)의 수질과 부착조류 생물량에 온배수와 수소이온농도 (pH) 영향 (Effects of Thermal Wastewater Effluent and Hydrogen Ion Potential (pH) on Water Quality and Periphyton Biomass in a Small Stream (Buso) of Pocheon Area, Korea)

  • 전경혜;엄현수;정진호;황순진;신재기
    • 생태와환경
    • /
    • 제50권1호
    • /
    • pp.96-115
    • /
    • 2017
  • 온배수와 산성화는 오래 전부터 전 세계를 통해 육수학과 수생태학에서 많은 관심을 갖게 한 분야이었다. 그러나 우리나라는 아직까지 초보적이거나 접근 조차 미진한 실정에 있다. 본 연구는 2015년 12월부터 2016년 9월까지 경기도 포천에 위치한 계류(부소천)의 최상류 구간 5개 지점(BSU (상류), HSW (온천폐수 방류구), BSD1~3 (하류))에서 수질환경과 부착조류 생태계에 온배수와 산성비의 시공간적 영향을 파악하고자 매월 조사하였다. 조사기간 동안 수온의 범위(평균값)는 $1.7{\sim}28.8^{\circ}C$($15.0^{\circ}C$)이었다. 특히 HSW의 범위와 평균값은 17.5 (1월)~$28.8^{\circ}C$(9월), $24.2{\pm}3.7^{\circ}C$로서 고온을 유지하였고, 다른 지점에 비해 월등히 높았다. 온배수는 하천수의 수온 증가와 영양염 펄스로서 작용하였으며, 그 영향은 갈수기와 저온기 (12월~3월)에 우세하였다. 그리고 온도의 영향권은 유하 거리에 따라 멀지 않았으나, P N 영양염은 다소 원거리까지 미칠 수 있는 잠재력을 갖고 있었다. pH는 5.1~8.4 (6.9)이었다. 수중 pH 감소의 원인은 계절적으로 강설과 산성비의 습윤 산성강하물에 있었고, 그 영향은 부착 규조류 중 호산성 종조성(Eunotia pectinalis, Tabellaria flocculosa)의 생물학적 분포에서 간헐적(3월과 8월)으로 확인되었다. 부소천의 수질과 부착조류 생태계는 열 오염, 부영양화 및 산성화에 의한 역동적인 상태이었고, 계류, 온배수 및 대기오염과 같은 지리 지역적 특성에 기반한 인위적 영향이 지배적이었다.

폐석면광산 주변 지역의 주택 침적먼지의 석면 검출과 석면폐증의 관련성 (Exposure Assessment and Asbestosis Pulmonum among Inhabitants near Abandoned Asbestos Mines Using Deposited Dust)

  • 안호기;양원호;황보영;이용진
    • 한국환경보건학회지
    • /
    • 제41권6호
    • /
    • pp.369-379
    • /
    • 2015
  • Objectives: The lack of reliable information on environmental pollution and health impacts related to asbestos contamination from abandoned mines has drawn attention to the need for a community health study. This study was performed to evaluate asbestos-related health symptoms among residents near abandoned asbestos mines located in the Chungcheong Provinces. In addition, exposure assessment for asbestos is needed although the exposure to asbestos was in the past. Methods: Past exposure to asbestos among inhabitants near abandoned asbestos mines was estimated by using surface sampling of deposited dust in indoor and outdoor residences. A total of 54 participants were divided into two groups with (34 cases) and without (20 controls) diseases related to asbestos. Surface sampling of deposited dust was carried out in indoor and outdoor residences by collecting 105 samples. Deposited dust for sampling was analyzed by polarization microscope (PLM) and scanning electron microscope?energy dispersive x-ray spectrometer (SEM-EDX) to detect asbestos. Subsequently, the elements of the deposited dust with asbestos were analyzed by SEM-EDX to assess the contribution of sources such as abandoned mines, slate and soil. Results: Among the 105 samples, asbestos was detected by PLM in 29 (27.6%) sampling points, and detected by SEM in 56 (48.6%) sampling points. Asbestos in indoor residences was detected by PLM in four sampling points, and by SEM in 12 sampling points. Asbestos detection in indoor residences may be due to ventilation between indoors and outdoors, and indicates long-term exposure. The asbestos detection rate for outdoor residences in the case group was higher than that in the control group. This can be explained as the case group having had higher exposure to asbestos, and there has been continuous exposure to asbestos in the control group as well as the case group. Conclusion: Past residential asbestos exposure may be associated with asbestosis among local residents near abandoned asbestos mines. Odds ratios were calculated for asbestos detection in outdoor residence by logistic regression analysis. Odds ratio between asbestos detection and asbestosis pulmonum was 3.36 (95% CI 0.90-12.53) (p=0.072), adjusting for age, sex, smoking status and work history with multi-variable logistic regression by PLM analysis method.

가축 액상분뇨의 시용방법이 벼의 생육과 수량에 미치는 영향 (Effect of Application Methods for Liquid Pig Slurry on Growth and Yield of Rice(Oryza sativa L.))

  • 류종원;홍미자
    • 한국축산시설환경학회지
    • /
    • 제10권2호
    • /
    • pp.75-80
    • /
    • 2004
  • 본 연구는 액상분뇨 시용방법의 벼의 생육특성, 수량, 수량구성 요소, 쌀 품질에 미치는 영향을 구명하기 위하여 실시되었다. 처리는 액상분뇨를 기비만 처리한 처리구, 액상분뇨를 기비로 시용하고 화학비료를 추비로 시용한 시험구, 대조구로 화학비료 시용구를 두었다. 시험결과를 요약하면 아래와 같다. 1. 초장은 생육초기 화학비료구가 가장 큰 것으로 나타났으나 생육후기에는 초장의 차이가 처리구 간에 크지 않았다. 분얼 수의 경우도 화학비료구가 액비 시용구보다 더 많았다. 엽록소 함량은 생육초기 화학비료 시용구에서 생육 후기에는 처리간에 유의한 차이가 없었다. 2. 수량구성 요소에 있어서 주당수수는 화학비료구가 가장 많은 것으론 나타났다. 수당립수는 액상분뇨 시용구에서 가장 많았으며 천립중은 시비처리구 사이에 차이가 없는 것으로 나타났다. 등숙율에 있어서는 화학비료 시용구가 높은 것으로 나타났다 3. 벼의 정조수량은 화학비료 시용구에서 가장 높았고 액비+화학비료구에서 $3\%$ 액상분뇨 시용구에서 화학비료 시용구 대비 $5\%$ 감수되었다. 4. 쌀 품질은 액상분뇨 시용구와 액비기비 +화학비료 추비구가 화학비료구에 비해 상당히 높게 나타났다. 단백질 함량은 액비 시용구가 화학비료 시용구보다 유의성있게 낮았다. 따라서 쌀 품질 향상에 적절한 양의 액비 시용이 효과가 있는 것으로 나타났다.

  • PDF

FDI 유형별 CO2 배출량에 미치는 영향 분석 - 규모효과와 기술효과를 중심으로 - (An Analysis of the Impacts of FDI Types on CO2 Emissions - Focus on Scale Effects and Technique Effects -)

  • 황윤섭;박정훈;이상휘
    • 통상정보연구
    • /
    • 제17권3호
    • /
    • pp.379-402
    • /
    • 2015
  • 본 연구는 국내 제조업으로 유입된 FDI 유형을 Greenfield FDI와 M&A FDI로 나눠 각 유형이 $CO_2$ 배출량에 미치는 영향을 규모효과와 기술효과로 나눠 살펴보고, FDI 유형별로 두 가지 효과에 미치는 영향력의 차이를 비교하여 궁극적으로 FDI와 환경오염 간 관계를 명확히 하는 데 그 목적이 있다. 이를 위해 본 연구는 각 변수 간 동시적 영향관계를 분석하고 상호작용을 파악하기 위해 연립방정식 형태로 연구모형을 구성했고, 1995년부터 2009년까지의 국내 13개 제조업의 패널자료를 이용하여 3단계 최소제곱법 (3SLS)으로 실증분석했다. 분석결과는 크게 2가지로 요약된다. 첫째, Greenfield FDI는 M&A FDI에 비해 규모효과를 통해 산업 생산량 증가에 더 큰 영향을 미치고, 결과적으로 $CO_2$ 배출량 증가에도 더 큰 영향력을 미친다. 둘째, FDI의 기술효과가 규모효과에 비해 $CO_2$ 배출량에 미치는 영향력이 더 크고, 이는 국내 제조업으로 유입되는 FDI가 $CO_2$ 배출량 감소에 유의한 영향을 미친다는 것을 의미한다. 이러한 결과들은 FDI 유형별로 정책 인센티브 등을 달리함으로써 환경보호 효과를 극대화시키는 방안이 마련되어야 한다는 시사점을 제시하고, 결과적으로 환경을 고려한 FDI 정책 수립에 기여할 것으로 기대된다.

  • PDF