• Title/Summary/Keyword: Pollution sources

Search Result 1,048, Processing Time 0.034 seconds

A Study on Estimation of Air Pollutants Emission from Residential Wood Stove (주거용 화목난로의 대기오염 배출량 추정에 관한 연구)

  • Kim, Pil-Su;Jang, Young-Kee;Kim, Jeong;Shin, Yong-Il;Kim, Jeong-Soo;An, Jun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.276-285
    • /
    • 2010
  • Recently the Korean government has tried to cut down the $PM_{10}$ concentration by the Special Law for Air Quality Improvement. But the concentrations of $PM_{10}$ have exceeded the air quality standard at most monitoring stations. Primary $PM_{10}$ emitted from various sources and emission data have large uncertainty. The biomass burning is one of the major sources of $PM_{10}$ emission. The biomass burning is composed of wood stove usage, meat cooking and agricultural combustion etc.. Activity data and emission factors for the biomass burning are limited, and it is hard to calculate the air pollution emissions from these sources. In this study, we tried to estimate the air pollution emission from residential wood stove usage. The number of total wood stoves is estimated by the survey of wood stove manufacturer. And air pollution emission factors for the wood stove are investigated using the flue gas measurement by U.S. EPA particulate test method (Method 5G). As the results, the $PM_{10}$ and CO emission factors of wood stove are estimated as 7.7 g/kg-wood and 78.8 g/kg-wood respectively. The annual $PM_{10}$ and CO emissions from wood stove are calculated as 1,200~3,600 ton/year and 12,600~36,400 ton/year in Korea. It is confirmed that wood stove is the one of major sources of biomass burning, and the survey for activity data and the measurement for emission factors are needed for reducing the uncertainty of these emission data.

Spatiotemporal Variations and Possible Sources of Ambient PM10 from 2003 to 2012 in Luzhou, China

  • Ren, Dong;Li, Youping;Zhou, Hong;Yang, Xiaoxia;Li, Xiaoman;Pan, Xuejun;Huang, Bin
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.331-338
    • /
    • 2014
  • Descriptive statistics methods were used to study the spatiotemporal variations and sources of ambient particulate matter ($PM_{10}$) in Luzhou, China. The analyzed datasets were collected from four national air quality monitoring stations: Jiushi (S1), Xiaoshi (S2), Zhongshan (S3), Lantian (S4) over the period of 2003-2012. This city was subjected serious $PM_{10}$ pollution, and the long-term annual average $PM_{10}$ concentrations varied from 76 to $136{\mu}g/m^3$. The maximum concentration was more than 3-fold of the annual average ($40{\mu}g/m^3$) issued by EPA-China for the ambient air quality. General temporal pattern was characterized by high concentrations in winter and low concentrations in summer, and general spatial gradient was in the reduction order of S2 > S4 > S3 > S1, which were both due to different particulate contributors and special meteorological conditions. The source apportionment indicated that vehicular emissions, road dusts, coal burning and chemical dusts were the major contributors of the identified $PM_{10}$ pollution, and the vehicular emissions and the road wear re-suspended particles dominated the heavy $PM_{10}$ pollution in recent years. Two other potential sources, agricultural and celebration activities could decrease the air quality in a short term. Finally, some corresponding suggestions and measures were provided to improve the air quality.

Current Management Status of Mercury Emissions from Coal Combustion Facilities: International Regulations, Sampling Methods, and Control Technologies

  • Lee, Sung-Jun;Pudasainee, Deepak;Seo, Yong-Chil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.E1
    • /
    • pp.1-11
    • /
    • 2008
  • Mercury (Hg), which is mainly emitted from coal-fired power plants, remains one of the most toxic compounds to both humans and ecosystems. Hg pollution is not a local or regional issue, but a global issue. Hg compounds emitted from anthropogenic sources such as coal-fired power plants, incinerators, and boilers, can be transported over long distances. Since the last decade, many European countries, Canada, and especially the United States, have focused on technology to control Hg emissions. Korea has also recently showed an interest in managing Hg pollution from various combustion sources. Previous studies indicate that coal-fired power plants are one of the major sources of Hg in Korea. However, lack of Hg emission data and feasible emission controls have been major obstacles in Hg study. In order to achieve effective Hg control, understanding the characteristics of current Hg sampling methods and control technologies is essential. There is no one proven technology that fits all Hg emission sources, because Hg emission and control efficiency depend on fuel type, configuration of air pollution control devices, flue gas composition, among others. Therefore, a broad knowledge of Hg sampling and control technologies is necessary to select the most suitable method for each Hg-emitting source. In this paper, various Hg sampling methods, including wet chemistry, dry sorbents trap, field, and laboratory demonstrated control technologies, and international regulations, are introduced, with a focus on coal-fired power plants.

Problems and their Counter-measures in Water Quality Preservation (수질보전상의 문제와 대책)

  • Ryu Jae Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.2 no.2 s.2
    • /
    • pp.69-78
    • /
    • 1987
  • Due to the increase of population and development of industry, the demand of available water resources increased . Many reservoirs have been constructed in large scales to meet this urgent need , resulting in the increased amount of water resources. After the constructions, however, serious pollution-especially eutrophication-in some reservoirs become a socialaffair. Therefore, water quality control in these resources should be considered more intensively than any other environmental preservation policies. It also seems to be imminent to prepare the precautionary steps. Most water pollution in Korea-73 percent - can be traced to domestic sewage. It may rome as a surprise to Some, Industry is responsible for just 27 percent of ]Korea's water pollution. What he calls 'non-point' Sources, which may include agricultural Chemicals, Create only negligible amount of water pollution. Up to $15\%$ of domestic sewage is treated in Korea, which is quite low when compared with the waste processing in developed countries. So it is the most urgent matter to control the pollution sources. One of the precautionary plans, more urban domestic sewage treatment plants must be installed and operated efficiently. It is known that nutrients such as nitrogen and phosphorous are the major factors the process of eutrophication, which can be removed majorly by the tertiary or advanced treatment process.

  • PDF

A Study on the Development of the Mercury Emission Factor from Coal-fired Power Plant (석탄 화력발전시설에서의 수은 배출계수 개발에 관한 연구)

  • Kim, Hyung-Chun;Park, Jung-Min;Jang, Kee-Won;Lee, Sang-Bo;Jung, No-El;Song, Deok-Jong;Hong, Ji-Hyung;Lee, Suk-Jo;Kim, Sang-Kyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.2
    • /
    • pp.172-181
    • /
    • 2012
  • Mercury is one of the most hazardous air pollutants. Recently, mercury has been a concern in domestic and overseas because it has lethal toxicity, long distance transport, persistence and bioaccumulation in the environment. Stationary combustion sources such as coal-fired power plants, waste incinerators, and cement kilns are the major sources of mercury emissions. The objectives of this study were to measure the concentration for mercury from coal-fired power plants and to calculate emission factor to estimate its emission. The results showed that the mercury concentrations in the flue gas were 1.63-3.03 mg/$Sm^3$ in anthracite-fired power plants (average 2.32 mg/$Sm^3$) and 1.95-3.33 mg/$Sm^3$ in bituminous-fired power plants (average 2.6 mg/$Sm^3$). Mercury emission factor was estimated as 25.74 mg/ton for anthracite-fired power plants and 12.48 mg/ton for bituminous-fired power plants. Because actual measurements are limited in quantity, it is desirable to refine our estimates by extending the actual measurements.

Eutrophication Modelling in Gunsan Estuary (군산하구 해역에서의 부영양화 모델링)

  • Kim, Jong-Gu;Jung, Tae-Ju;Kang, Hoon;Kim, Jun-Woo;Lee, Nam-Do
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.05a
    • /
    • pp.191-200
    • /
    • 2003
  • Gunsan coastal area is one of region increasing pollution problems. One of the most important factors that cause eutrophication is nutrient materials containing nitrogen and phosphorus which stem from excreation of terrestial sources. At this study, the three-dimensional numerical hydrodynamic and ecosystem model, which was developed by Institute for Resources and Environment of Japan, were applied to analyze the processes affecting the eutrophication. The residual currents, which were obtained by integrating the simulated tidal currents over 1 tidal cycle, showed the presence of a typical. Density driven currents were generated westward at surface and eastward at the bottom in Geum estuary area where the fresh waters are flowing into. The ecosystem model was calibrated with the data surveyed in the field of the study area in annual average. The simulated results of DIN were fairly good coincided with the observed values within relative error of 32.39%. correlation coefficient(r) of 0.99. In the case of DIP, the simulated results were fairly good coincided with the observed values within relative error of 24.26%, correlation coefficient (r) of 0.82. The simulations of DIN and DIP concentrations were performed using ecosystem model under the conditions of 20 ∼ 80% pollution load reductions from pollution sources. In study area, concentration of DIN and DIP were reduced to 20∼80% and under 10% in case of the 80% reduction of the input loads from fresh water respectively. But pollution loads from sediment had hardly affected DIN and DIP concentration. For the environment management of coastal areas, in case of Kunsan area, the most important pollution sources affecting eutrophication phenomenon were found to be the input loads from fresh water.

  • PDF

A Study on the Improvement of Accuracy in Mapping the Distribution of the Emission Volume of Air Pollution Using GIS (GIS를 이용한 대기오염 배출량 분포도의 정확도 향상에 관한 연구)

  • 최진무
    • Spatial Information Research
    • /
    • v.6 no.1
    • /
    • pp.65-76
    • /
    • 1998
  • Air contaminant density must be inferred exactly to manage air pollution. Each land use of air pollution source is duplicated in the existing air contaminant distribution because the resolution of the land use map is low. The purpose of this study is to understand how the land use map is used to determine effectively in the distribution calculation of the emission volume and the inference of air contaminant density, as it is made in a high resolution. The major findings are as follows : In this study, as to making a high resolution($28.5m{\times}28.5m$) map of land use with GIS, each air pollution source is not duplicated spatially and land use can be reflected effectively. In Seoul, each air contaminant density was inferred (using a TCM-2 model) with the existing distribution map of emission volume, whose resolution is $1km{\times}1km$, and the new distribution map of emission volume, whose resolution is $28.5km{\times}28.5km$. According to the result, the inference value of the new distribution map was more similar to the actual value of an automatic survey network.

  • PDF

Antimicrobial Resistance of Escherichia coli Isolates from Mussel Mytilus galloprovincialis Farms and Inland Pollution Sources in the Changseon Area, Korea (창선 해역의 지중해담치(Mytilus galloprovincialis) 양식장 및 육상오염원에서 분리한 대장균(Escherichia coli)의 항생제 내성)

  • Kwon, Soon Jae;Lee, Ka Jeong;Jung, Yeoun Joong;Park, Sang Gi;Go, Kyeong Ri;Yang, Ji Hye;Mok, Jong Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.5
    • /
    • pp.564-572
    • /
    • 2016
  • In this study, we isolated and characterized Escherichia coli from mussels and inland pollution sources in or in proximity to the Changseon area on the southern coast of Korea in 2014. A total of 147 strains of E. coli were isolated from 54 mussels and 32 pollution-source samples. The susceptibility of the isolates to 24 antimicrobial agents was analyzed. The resistance of E. coli isolates to rifampin was highest at 100%, followed by cephalothin (98.6%), tetracycline (91.8%), amikacin (81.0%), ampicillin (79.6%), cefazolin (79.6%), streptomycin (73.5%), piperacillin (70.7%), gentamicin (37.4%), cefoxitin (35.4%), cefamandole (34.7%), tobramycin (29.9%), amoxicillin/clavulanic acid (24.5%), nalidixic acid (21.8%), trimethoprim (19.0%), chloramphenicol (17.7%), cefotaxime (12.9%), trimethoprim (10.9%), ceftazidime (10.2%), aztreonam (7.5%), imipenem (2.7%), cefepime (2.0%), and cefotetan (0.0%). In addition, the antimicrobial resistance of E. coli isolates from inland pollution sources was slightly greater than or similar to that of isolates from mussels.

Analysis of Runoff Characteristics of Non-point Sources Pollutant and Application of BMP Using BASINS/WinHSPF Model (BASINS/WinHSPF 모형을 이용한 비점오염물질 유출특성 분석과 최적관리기법 적용)

  • Kim, Min Joo;Kim, Tae Geun
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.2
    • /
    • pp.88-100
    • /
    • 2014
  • This study analyzed runoff characteristics of non-point sources pollutant and evaluated removal of pollution by BMP(Best Management Practice) using BASINS/WinHSPF model. Hourly meterological data including input data was provided from 2010 to 2011 year to run HSPF model in Miho stream watershed. As the results of calibration and validation of the model, the model could be successfully performed to simulate the flow and water quality parameters. The apprehensive area of non-point source pollution was chosen by non-point source pollution per area of a tributary to the Miho stream and applied constructed wetland in area chosen. Three scenarios were based on installation area of an constructed wetland and HSPF model would be applied to estimate the pollutant removals through the constructed wetland. The removal rates of pollutants through the constructed wetland were estimated with the runoff and water quality parameters by the comparisons of before and after the constructed wetland application.

The role of nuclear energy in the correction of environmental pollution: Evidence from Pakistan

  • Mahmood, Nasir;Danish, Danish;Wang, Zhaohua;Zhang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1327-1333
    • /
    • 2020
  • The global warming phenomenon emerges from the issue of climate change, which attracts the attention of intellectuals towards clean energy sources from dirty energy sources. Among clean sources, nuclear energy is getting immense attention among policymakers. However, the role of nuclear energy in pollution emissions reduction has remained inconclusive and demand for further investigation. Therefore, the current study contributes to extend knowledge by investigating the nexus between nuclear energy, economic growth, and CO2 emissions in a developing country context such as Pakistan for the period between 1973 and 2017. The auto-regressive distributive lag model summarizes the nuclear energy has negative effect on environmental pollution as it releases carbon emission in the environment. Moreover, vector error correction Granger causality provides evidence for bidirectional causality between nuclear energy and carbon emissions. These interesting findings provide new insight, and policy guidelines provided based on these results.