• Title/Summary/Keyword: Pollution inflow

Search Result 186, Processing Time 0.023 seconds

Characteristics of TOC Distribution in Lake Hapcheon (합천호의 TOC 분포 특성)

  • Seong, Jin-Uk;Kim, Hyung-Jin;Park, Jae-Chul
    • Journal of Environmental Science International
    • /
    • v.20 no.6
    • /
    • pp.711-719
    • /
    • 2011
  • This study was conducted to estimate the distribution characteristics and budget of organic matter in the Lake Hapcheon. In the dry season, the concentration ranges of organic carbons were similar, but in the rainfall season, it showed about double concentrations. Changes of vertical water quality in the lake, there were no big differences with the concentration by the depth. However, it tends to be relatively high on the surface, a little low on the mid-depth and high in the lake bottom. DOC rate at TOC, it was lower than POC rate at inflow and DOC rate was higher than POC rate in the lake and discharging water. R-DOC accounted for more 80% of DOC rate in all investigated areas, therefore we judge that this R-DOC is to increase the organic carbon pollution gradually. As the result of the calculated organic carbon budget in the Lake Hapcheon, the amount of allochthonous, autochthonous and release were 3,552, 3,288, 228 tonC/year, respectively. the amount of discharge, decomposition and sedimentation were 504, 1,344, 5,520 tonC/year, respectively. According to this investigation, the changed amount of organic matter in the Lake Hapcheon recorded -300 tonC/year with the increase of 7,068 tonC/year and the decrease of 7,368 tonC/year.

Effect of an Urban Thermal Environment on the Air Quality in Two Cities

  • Lee, Kwi-Ok;Lee, Hwa-Woon;Lee, Hyun-Ju;Park, Jong-Kil;Jung, Woo-Sik
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.29-40
    • /
    • 2011
  • In this study, the effects of an urban thermal environment on air quality were investigated using hourly surface weather observation data and air quality data over six summers from 2000 to 2005 in two cities on the Korean Peninsula. One, the city of Daegu, is representative of basin topography and the other, the city of Busan, represents a coastal area. It is known that the characteristics of an urban thermal environment are represented as an "urban heat island". Here, we focus on the nighttime urban thermal environment, which is called a "tropical night", during the summer. On tropical nights in Busan, the temperature and cloud cover levels were higher than on non-tropical nights. Wind speed did not appear to make a difference even on a tropical night. However, the frequency of southwestern winds from the sea was higher during tropical nights. The prevailing southwest winds in all areas meant an inflow of air from the sea. So at most of the air quality stations, the ozone concentration during tropical nights was lower than during non-tropical nights. In Daegu, the tropical nights had higher temperatures and cloud covers. Despite these higher temperatures, the ozone concentration during the tropical nights was lower than that on non-tropical nights at most of the air quality stations. This feature was caused by low irradiance, which in turn caused an increased cloud cover. Wind speed was stronger during the tropical nights and dispersed the air pollutants. These meteorological characteristics of the tropical nights reduced ozone concentrations in the Daegu Basin.

Spatial Distribution and Improvement of Water Quality in the Youngrang Lake (영랑호 수질의 공간적 분포 및 개선방안)

  • Huh, In-Ryang;Yi, Geon-Ho;Jeong, Won-Gu;Kwon, Jae-Hyouk
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.341-347
    • /
    • 2017
  • From 2014 to 2016 water quality survey results according to the location and depth of Youngrang Lake are as follows: Distribution of dissolved oxygen in the water depth was investigated by the middle section and the downstream 1st, 3rd, 5th, when investigating bottem 1m interval anoxic layer. In organic matter and nutrient concentration distribution COD upstream 2.8 mg/L, middle section 4.2 mg/L downstream 4.1 mg/L, more than two times higher in bottem layer and TP concentrations showed a similar trend with COD, upstream of 0.047 mg/L, middle section was 0.051 mg/L, downstream of 0.059 mg/L. There was a difference in salinity every survey period the average salinity is lowest with 28.5‰ when the second survey. And the highest with 32.1‰ in the fourth investigation. Korean trophic state index($TSI_{KO}$) were showed eutrophic conditions in the middle section and downstream else showed mesotrophic state in the entire period. In order to evaluate the cause of water pollution Youngrang lake, regression analysis of the relationship between salinity and DO, COD, TN, TP, Chl-a results, $R^2$ is from 0.63 to 0.95 Youngrang lake water quality was found to have a close relationship with salinity due to inflow of seawater. As a result, in order to improve the quality of Youngrang lake efficient incorporation of the amount of water through the seawater influent as it is considered the key.

Evaluation of treatment efficiencies of pollutants in daecheong lake juwon stream constructed wetlands (대청호 주원천 인공습지의 오염물질 정화효율 평가)

  • Kim, Tae-Hun;Sung, Ki-Eun;Ha, Duk-Ho;Kim, Dong-Hee;Heo, Soon-Uk;Choi, Chung-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.211-222
    • /
    • 2015
  • This study focused on evaluating the efficiency of the removal of non-point source pollution by Daecheong Lake Juwon Stream constructed wetlands. The constructed wetland system is a surface flow type designed in the year 2007 for purifying eutrophic water of Daecheong Lake Juwon Stream. The value of conductivity, suspended solids(SS), chemical oxygen demand using a potassium permanganate($COD_{Mn}$), five-day biochemical oxygen demand($BOD_5$), total nitrogen(T-N), total phosphorous(T-P), and pH in inflow averaged 220.2, 2.46, 3.33, 1.34, 2.00, 0.04 mg/L and 7.24, respectively and in outflow averaged 227.9, 1.12, 3.34, 0.87, 1.16, 0.02 mg/L and 7.45, respectively. The average removal efficiency of constructed wetlands was 30 % for SS, 22 % for $BOD_5$, 45 % for T-N and 31 % for T-P. The removal rates of SS, $BOD_5$ and T-N in the spring, summer and autumn were higher than those in winter. The removal rate of T-P was not significant different in all seasons. The amounts of pollutants removal in the constructed wetlands were higher in the order of $3^{rd}$ < $2^{nd}$ < $1^{st}$ wetland for SS and T-P, $2^{nd}$ < $3^{rd}$ < $1^{st}$ wetland for $BOD_5$ and T-N. Therefore, our findings suggest that the constructed wetlands could well treat the eutrophic Daecheong Lake Juwon Stream waters.

The Study on Development and Verification of Rainfall-Runoff Simulator for LID Technology Verification (LID 기술의 효율성 검증을 위한 강우-유출 모의장치 개발 및 검증실험에 관한 연구)

  • Jang, Young Su;Kim, Mi Eun;Baek, Jong Seok;Shin, Hyun Suk
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.6
    • /
    • pp.513-522
    • /
    • 2014
  • Climate change and urbanization have affected a increase of peak discharge and water pollution etc. In a view of these aspects, the LID(Low Impact Development) technology has been highlighted as one of adjustable control measures to mimic predevelopment hydrologic condition. Many LID technologies have developed, but there is a lack of studies with verification of LID technology efficiency. Therefore this study developed a rainfall-runoff simulator could be possible to verify LID technology efficiency. Using this simulator, this study has experimented the rainfall verification through the rainfall distribution experiment and the experiment to show the relation between inflow and effective rainfall in order to sprinkle the equal rainfall in each unit bed. As a result, the study defined the relation between allowable discharge range and RPM by nozzle types and verified the hydrologic cycle such as the relation between infiltration rate, surface runoff and subsurface runoff at pervious area and impervious area through the rainfall-runoff experiment.

Control of Microstructure on TiO2 Nanofibers for Photocatalytic Application (광촉매 응용을 위한 TiO2 나노 섬유의 미세구조 제어)

  • Lee, Chang-Gyu;Kim, Wan-Tae;Na, Kyeong-Han;Park, Dong-Cheol;Yang, Wan-Hee;Choi, Won-Youl
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.417-421
    • /
    • 2018
  • $TiO_2$ has excellent photocatalytic properties and several studies have reported the increase in its specific surface area. The structure of $TiO_2$ nanofibers indicates promising improved photocatalytic properties and these nanofibers can thus potentially be applied in air pollution sensors and pollutant removal filters. In this study, a $TiO_2$ nanofiber was fabricated by the electrospinning method. The fabrication processing factors such as the applied voltage, the distance between nozzle and collector, and the inflow rate of solution were controlled. The precursor was titanium (IV) isopropoxide and as-spun $TiO_2$ nanofibers were heated at $450^{\circ}C$ for 2 h to obtain an anatase crystalline structure. The microstructure was analyzed using field emission scanning electron microscope (FE-SEM) and X-ray diffraction analysis (XRD). The anatase phase was observed in the $TiO_2$ nanofibers after heat treatment. The diameter of $TiO_2$ nanofibers increased with the flow rate, but decreased with decreasing applied voltage and nozzle to collector distance. The diameter of $TiO_2$ nanofibers was controlled in the range of 364 nm to 660 nm. These nanofibers are expected to be very useful in photocatalytic applications.

Experimental Study on the Wake Characteristics of a Perforated Vertical Wall with Gap in the 2-Dimensional Flow (2차원 흐름 중에 놓인 틈새를 갖는 수직벽 후류 특성에 관한 실험적 연구)

  • Jo Dae-Hwan;Oh Kyoung-Gun;Lee Gyoung-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.135-140
    • /
    • 2005
  • There are cofferdam and watertight wall to prevent of circulation or pollution during building of ocean structures like a dam and bridge in the harbors area and the sea. Inflow fluid and base of structure is important thing as one of the structural design factors for this interception wall like a cofferdam and watertight wall. In this study, it is revealed that at least 500 instantaneous velocity field data are required for ensemble average to get reliable turbulence statistics. The turbulent shear flow around a surface-mounted vertical wall was investigated by using the two-frame PIV(CACTUS 3.1) system and Mean velocity distributions have also been measured in the whole flow field.

  • PDF

Temporal and Spatial Analysis of Water Quality Data Observed from Major Water Quality Stations in Nakdonggang Watershed (낙동강 유역 주요 수질측정지점의 시·공간적 수질특성 분석)

  • Kim, So Rae;Kyung, Jo Hyun;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.545-545
    • /
    • 2017
  • The purpose of this study was to analyze the characteristics of water quality and spatial and temporal water quality in Nakdong River basin. Spatial changes of water quality in Nakdong River due to inflow of sewage treatment plant and main tributaries were analyzed. The water quality data were collected from the water environment information system of the National Institute of Environmental Research (NIED) for 8 days interval from 2004 to 2015, and the collected data were analyzed for water quality items (flow rate, BOD, TN, TP). The discharge water quality data of 32 sewage treatment plants were collected from the National Institute of Environmental Research (NIER) nationwide from 2012 to 2015 and arithmetically averaged over the spring and autumn seasons.

  • PDF

Analysis of the Effect of Water Quality Improvement on Seomgang and South Han River by Securing the Flow during the Dry Season (갈수기 유량 확보에 따른 섬강 및 남한강 본류 갈수기 수질 개선 효과 분석)

  • Lee, Seoro;Lee, Gwanjae;Han, Jeongho;Lee, Dongjun;Kim, Jonggun;Lim, Kyoung Jae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.25-39
    • /
    • 2019
  • The water pollution Accident in the South Han River is increasing due to increase of pollutants inflow from small streams from rural areas and reduced flow rate. This study predicted the change of water quality in the main stream of the South Han River due to climate change through the linkage of watershed and water quality models. Also, This study analyzed the effect of water quality improvement on Seomgang and the South Han River by securing the flow during the dry season. According to the scenarios for securing the river flow during drought season, the river flow in the Seomgang is increased up to 2.19 times, and the water quality during the drought season was improved up to $BOD_5$ 20.5%, T-N 40.8%, T-P 53.4%. Also, the water quality of the main stream of the South Han River improved to 5.22% of $BOD_5$, 5.42% of T-N and 7.69% of T-P as the river flow was secured from the Seomgang. The result of this study confirms that securing the baseflow in the Seomgang according to the scenarios for securing the river flow during the dry season has a positive effect on the improvement of the water quality of the rivers in the main river of the Seomgang and South Han River. The results of this study will contribute to the establishment of reasonable management to improve the water quality of the main stream of the Seomgang and South Han River.

Evaluation of Water Quality and Phytoplankton Community Using a Multivariate Analysis in Bukhan River (다변량 통계분석을 이용한 북한강의 수질 및 식물플랑크톤 군집 특성 평가)

  • Kim, Hun Nyun;Youn, Seok Jea;Byeon, Myeong Seop;Yu, Soon Ju;Im, Jong Kwon
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.19-27
    • /
    • 2019
  • The purpose of this study is to evaluate the water quality and phytoplankton community in Bukhan River which account for 44.4 % of the total inflow into Lake Paldang, using multivariate statistical techniques (i.e., correlation analysis, principal component analysis (PCA)/factor analysis (FA)). Water samples were collected from March to November 2015 and the following parameters measured; water temperature, pH, DO, EC, SS, BOD, Chl-a, COD, TN, $NO_3-N$, $NH_3-N$, TP, DTP, $PO_4-P$, and phytoplankton community. The water quality of the main stream and the tributaries were not significantly different apart from the relatively high concentration of BOD, COD and nutrients recorded in MH. The highest cell density of Stephanodiscus hantzschii and Merismopedia glauca dominated phytoplankton was observed in PD. Based on the correlation analysis, total phytoplankton and cyanophyceae were highly correlated with BOD, COD and nutrients. PCA/FA resulted in four main factors accounting for 82.240 % of the total variance in the water quality dataset. The group of component 1 (TN, DTN, DO, $NO_3-N$, water temperature) and component 2 ($PO_4-P$, T-P, DTP, SS) were classified as nutrient element factor whereas component 3 (Chl-a, COD, BOD, $NH_3-N$, pH) was related to organic substances. Hence, the identification of the main potential environmental pollution factors in Bukhan River will help policy makers make better and more informed decisions on how to improve the water quality.