• Title/Summary/Keyword: Pollution detection

Search Result 201, Processing Time 0.036 seconds

Assessment of Environmental Pollution with Tradescantia Bioassays (자주달개비 생물검정 기법을 이용한 환경오염 평가)

  • Kim Jin Gyu;Sin Hae Sik
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2004.05a
    • /
    • pp.1-15
    • /
    • 2004
  • Higher plants can be valuable genetic assay systems for monitoring environmental pollutants and evaluating their biological toxicity. Two assays are considered ideal for in situ monitoring and testing of soil, airborne and aqueous mutagenic agents; the Tradescantia stamen hair assay for somatic cell mutations and the Tradescantia micronucleus assay for chromosome aberrations. Both assays can be used for in vivo and in vitro testing of mutagens. Since higher plant systems are now recognized as excellent indicators and have unique advantages over in situ monitoring and screening, higher plant systems could be accepted by regulatory authorities as an alternative first-tier assay system for the detection of possible genetic damages resulting from the pollutants or chemicals used and produced by industrial sectors. It has been concluded that potential mutagen and carcinogen such as the heavy metals among indoor air particulates, volatile compounds in the working places, soil, and water pollutants contribute to the overall health risk. This contribution can be considerable under certain circumstances. It is therefore important to identify the level of genotoxic activity in the environment and to relate it to the biomarkers of a health risk in humans. The results from the higher plant bioassays could make a significant contribution to assessing the risks of pollutants and protecting the public firom agents that can cause mutation anuor cancer. The plant bioassays, which are relatively inexpensive and easy to handle, are recommended for the scientists who are interested in monitoring pollutants and evaluating their environmental toxicity to living organisms.

  • PDF

Analysis of PWM Converter for V-I Output Characteristics of Solar Cell

  • Han, Jeong-Man;Jeong, Byung-Hwan;Gho, Jae-Seok;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.62-67
    • /
    • 2003
  • Recently, photovoltaic system has been studied widely as a renewable energy system, because it does not produce environmental pollution and it has infinity energy source from the sun. A study on photovoltaic system has a lot of problems like as reappearance and repetition of some situation in the laboratory experiment for development of MPPT algorithm and islanding detection algorithm. because output characteristics of solar cell are varied by irradiation and surface temperature of solar cell. Therefore, the assistant equipment which emulates the solar cell characteristics which can be controlled arbitrarily by researcher is require to the researchers for reliable experimental data. In this paper, the virtual implement of solar cell (VISC) system is proposed to solve these problems and to achieve reliable experimental result on photovoltaic system. VISC system emulates the solar cell output characteristics, and this system can substitute solar cell in laboratory experiment system. To realize the VISC, mathematical model of solar cell is studied for driving converter and the DC/DC converters are compared in viewpoint of tracking error using computer simulation. Output dynamic characteristic of PV array is varied by irradiation and PWM converter performance is studied using PSIM simulator.

A Research on the Improvement of Visibility Using Low Deck Lighting in Bad Weather (악천후 시 낮은 도로조명을 이용한 도로 시인성 향상에 대한 연구)

  • Nam, Ki Ho;Kim, Chung Hyeok;Nam, Ki Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.3
    • /
    • pp.186-193
    • /
    • 2020
  • We investigate a fog-detection CCT control system using low deck lighting as a solution to the forward visibility of pole-type street lamps employed on existing roads. The lighting standards were met with a light source that has less compared with those of pole-type street lamps. The results show that the transmission rate was increased by changing the color temperature by automatically recognizing fog in bad weather and minimizing the phenomenon of lighting. In addition, it was allowed to create a safer and more comfortable driving environment for drivers owing to flicker or light pollution of existing pole-type street lamps. As a result, if lighting is used at a lower level than pole-type street lamps, the accident rate caused by securing the driver's forward visibility can be reduced sharply and existing problems can be resolved.

Design of Anti-Islanding Algorithm for Utility interactive Photovoltaic System (계통연계형 태양광 발전시스템에서 역충전방지 알고리즘 설계)

  • Gho, J.S.;Kim, H.S.;Choe, G.H.;Kim, H.S.;Lee, Y.J.;You, G.J.;Song, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.440-442
    • /
    • 1995
  • In a recently as renewable energy source photovoltaic(PV) system using solar energy has been very widely researched because of its pollution-free and infinity. Especially many researches are intensively focused on small scale utility interactive PV system which can use dead space and easily make power stabilized from unstable natural energy source. In this system one of the most important matters is islanding protection. Islanding phenomenon appears when power failure occurs. For the safety of utility interactive PV system must has the function of not only system protection but also detection of islanding. This paper describes parallel operating alghorithm using reactive power variation method and twin peak band pass filter. This alghorithm is verified useful by simulation.

  • PDF

Traffic Emission Modelling Using LiDAR Derived Parameters and Integrated Geospatial Model

  • Azeez, Omer Saud;Pradhan, Biswajeet;Jena, Ratiranjan;Jung, Hyung-Sup;Ahmed, Ahmed Abdulkareem
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.1
    • /
    • pp.137-149
    • /
    • 2019
  • Traffic emissions are the main cause of environmental pollution in cities and respiratory problems amongst people. This study developed a model based on an integration of support vector regression (SVR) algorithm and geographic information system (GIS) to map traffic carbon monoxide (CO) concentrations and produce prediction maps from micro level to macro level at a particular time gap in a day in a very densely populated area (Utara-Selatan Expressway-NKVE, Kuala Lumpur, Malaysia). The proposed model comprised two models: the first model was implemented to estimate traffic CO concentrations using the SVR model, and the second model was applied to create prediction maps at different times a day using the GIS approach. The parameters for analysis were collected from field survey and remote sensing data sources such as very-high-resolution aerial photos and light detection and ranging point clouds. The correlation coefficient was 0.97, the mean absolute error was 1.401 ppm and the root mean square error was 2.45 ppm. The proposed models can be effectively implemented as decision-making tools to find a suitable solution for mitigating traffic jams near tollgates, highways and road networks.

Improvement of Validity and Efficiency for Detection of Cryptosporidium Ocysts and Giardia Cysts in Environmental Water Samples (환경수 중 크립토스포리디움 오시스트 및 지아디아 시스트 검출의 정확도 및 회수율 향상을 위한 연구)

  • 이목영;조은주;김도연;변승헌;이의광;오세종;안승구
    • Korean Journal of Microbiology
    • /
    • v.39 no.1
    • /
    • pp.27-35
    • /
    • 2003
  • No currently available methods to monitor pathogenic protozoa, Cryptosporidium and Giardia in environmental water come close to acceptable sensitivity, specificity and reproducibility, and so it has to be accompanied by thorough quality control and performance evaluation to credibly predict the distribution of them. We collected surface water samples from the Han River and spiked our prepared (oo)cysts, determined Matrix Spike recoveries using USEPA Method 1623 and considered what factors influence MS recovery and validity. As a result, average 46% of spiked oocysts and 60% of spike cysts were recovered, but repetitive sampling and statistical approach seemed to be necessary to determine the environmental pollution level of two protozoa as their variation coefficients was so much as 35oio and 26%. And MS recoveries with two acid dissociations during immunomagnetic separation were improved more 10% than that with one dissociations and the use of spiked suspension enumerated by flow cytometry instead of manual preparation enhanced the validity and reliability in spiking tests. Because fluorescence characteristics of (oo)cysts stained on well slides with FITC-labeled monoclonal antibodies and DAPI was not always same, well Elides from spiked field samples were helpful to evaluate the performance of staining. We found many (oo)cyst-like objects with typical fluorescence, not (co)cysts, from the Han River water samples, and then it was concluded that nuclei staining by DAPI (4',6-diamidino-2-phenylindole) and examination by Differential Interference Contrast Microscope should be critical for valid identification.

Detection of Enterococci and their Vancomycin Resistance in Drinking Spring-Water (먹는물 약수터 장구균의 검출 특성과 반코마이신 내성 현황)

  • Yoon, Tae-Ho;Lee, Hyang;Lee, Seung-Joo;Yeo, In-Hak;Eom, Seok-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.979-985
    • /
    • 2010
  • This study was performed to detect enterococci strain as an indicator of faecal contamination, to identify of 16S rDNA sequence and vancomycin resistance by MIC (Minimum Inhibitory Concentration) test from drinking spring-water samples in Seoul. The detection frequency of enterococci was 42 (19.8%) among 212 samples, and its concentration was ranged from 0 to 110 CFU/100 mL. These results were confirmed the possibility as an indicator microorganisms that similar to the frequency of E. coli detection (t test p-value 0.268, significant level 0.05). Isolated 56 enterococci samples were identified by 16S rDNA sequence data and their NCBI BLAST searching. They were identified to Enterococcus faecalis of 24 samples, E. faecium (10), E. casseliflavus (10), E. gallinarum (3), E. hirae (2), E. durans (2), E. sanguinicola (1). E. faecalis was dominant species that clinical case report of a domestic was similar. Vancomycin resistant enterococci (VRE) of 53 samples showed that vanB and vanC1/C2 type with 2 and 12 case, respectively. These results indicated that the drinking spring-water quarantined to fecal pollution for block out outbreak of gastrointestinal symptom with using such as disinfection process.

Effects of Physical Factors on Urban Surfaces on Air Quality - Chang Chun, China as an Example - (도시표면의 물리적 요소가 대기질에 미치는 영향 - 중국 창춘을 사례로 -)

  • Jin, Quanping;Kim, Tae Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.5
    • /
    • pp.1-11
    • /
    • 2021
  • The purpose of this study is to find out the main factors affecting air quality in urban physical space factors, and provide clues for environmental improvement. Nine monitoring stations in China's industrial city, Changchun, collected AQI concentration data from January 1, 2018 to December 31, 2019. This paper analyzes the types and distribution characteristics of urban physical facilities within a radius of 300m with the detection station as the center. The monitoring station is divided into three groups, and the difference in floating dust concentration among the three groups in different seasons is analyzed. The results show that AQI concentration is the highest in spring and winter, followed by summer, and the lowest in autumn. The place with the highest concentrations of AQI in spring are F (93.00), D (91.10), I (89.20), in summer are D (69.05), A (67.89), B (84.44), in autumn are I (62.80), G (60.84), D (53.27), D (53.27), in winter are I (95.82), H (95.60), f (94.04). Through SPSS analysis, it shows that the air index in a space with a diameter of 600 meters is related to forest land, grassland, bare land, water space, tree height, building area (average value), and building volume (average value). According to the statistical analysis results of spring and winter with the most serious pollution, forest land area (43,637m2, 15.44%) and water surface area (18,736m2, 6.63%) accounted for the majority, and group 1 (A, B, C) with the least average building area (448m2, 0.17%) and average building volume (10,201m2) had the lowest pollution concentration. On the contrary, group 2 (D, E, F) had the highest AQI concentration, with less or no woodland (1,917m2, 0.68%) and water surface area (0m2, 0%), and the highest average building area (1,056m2, 0.37%) and average building volume (17,470m3). It is confirmed that the characteristics of the area with the highest AQI concentration are that the more the site ratio of tree height above 12m, the smaller the site ratio of bare land, and the lower the pollution degree. On the contrary, the larger the area of bare land, the higher the pollution degree. By analyzing the characteristics of nine monitoring stations in Changchun, it can be seen that the air quality brought by the physical characteristics of urban space is closely related to the above factors.

A Study on pollution of spring in Incheon Area (인천 지역 약수터의 오염에 대한 연구)

  • Kim, Kyung-Ae;Lee, Byeng-Ok;Kim, Ou-Mok;Hur, Myung-Je;Kim, Kyung-Tae;Ro, Jae-Il;Choe, Choon-Suck;Go, Jong-Myoung;Kim, Yong-Hee
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.35-50
    • /
    • 2007
  • In order to investigate water pollution of spring, we carried out the experiments on mineral water, rainwater and surrounding soil of several springs collected in Incheon area from February to August in 2007. The results were as follows. 1. Soil : This study investigated the pH and organic matter contents in the soil which effect on microorganisms. The pH value was from 4.5 to 5.3 on average and organic matter contents ranged from 1.09% to 5.6% and E. coli, K. pneumoniae, S. faecalis and other microorganisms were isolated. 2. Natural mineral water : As the rainfall increased, the concentration of $No_3-N$, consumption of $KMnO_4$ and the number of microorganisms was increased while the other physicochemical items were not affected. The microorganism isolated in the natural mineral water were as follows: E. coli, K. oxytoca S. faecalis, S. facium, and so on from evacuation; E. agglomerans, E. amnigenus, E. cloacae, E. sakazakii and so on from the environments and evacuation. Detection of these microorganisms shows that the environment around the spring had been exposed to excrements of the warm blood animal. 3. Rain : The coliforms in the rain were the identical one detected from the mineral water and the soil. In conclusion the quality of natural mineral water is influenced by rain, resident bacteria of soil and surrounding environment. This study will be the basic data of characteristics of spring in Incheon area and also this result will give useful aids for the efficient control of spring.

Some considerations for the determination of carbonyl compounds in air: Reaction characteristics of formaldehyde with 2.4-DNPH (대기 중 카보닐 계열 성분의 분석기법의 연구: 포름알데하이드와 DNPH의 반응 특성을 중심으로)

  • Hong, Y.J.;Kim, K.H.
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • A number of carbonyl compounds including formaldehyde and acetaldehyde are well known for their toxicity and irritancy. Hence, acquisition of both qualitative and quantitative tool for their analysis is essential to resolve issues associated with malodor or indoor pollution. Using HPLC/UV method, we examined various aspects involved in the measurements of formaldehyde in environmental samples. The results of our analysis indicated that its detection was made as low as 0.5 ppb (assuming 5 L of sample volume), while its precision was maintained near 2% in terms of relative standard error (RSE). When the stability of calibration was checked by variability of slope values obtained over long-term period (e.g., one month), its values were found to remain constantly with RSE values of 3%. It was also found that liquid-phase reaction between formaldehyde and DNPH proceed very slowly to attain equilibrium (one and half hour), while requiring adequate amount of DNPH to form their derivatives. The overall results of our study thus suggest that there are a number of factors to consider for the accurate analysis of formaldehyde in ambient air.