• 제목/요약/키워드: Pollution Emission

검색결과 1,130건 처리시간 0.032초

철강 산업의 산업공정부문 CO2 실측 배출계수 산정에 관한 연구 (An Estimation of Plant Specific Emission Factors for CO2 in Iron and Steel Industry)

  • 엄윤성;홍지형;김정수;김대곤;이수빈;송형도;이성호
    • 한국대기환경학회지
    • /
    • 제23권1호
    • /
    • pp.50-63
    • /
    • 2007
  • The development of domestic plant specific emission factors is very important to estimate reliable national emissions management. This study, for the reason, was carried out to obtain advances emission factor for Carbon Dioxide ($CO_2$) by source-specific emission tests from the iron and steel industry sector which is well known as one of the major sources of greenhouse gases ($CO_2$). Emission factors estimated in this study were compared with those of IPCC for evaluation and they were found to be of similar level in the case of $CO_2$. There was no good information available on $CO_2$ plant specific emission factors from the iron and steel industry in Korea so far. The major emission sources of $CO_2$ examined from the iron and steel manufacturing precesses were a hot blast stove, coke oven, sintering furnace, electric arc furnace, heating furnace, and so on. In this study, the concentration of $CO_2$ from the hot blast stove process was the highest among all processes. The $CO_2$ emission factors for a ton of Steel and Iron products (using B-C oil) were estimated to be 0.315 $CO_2$ tonne (by Tier 3 method) and 4.89 $CO_2$ tonne. In addition, emission factor of $CO_2$ for heating furnace process was the highest among all process. Emission factors estimated in this study were compared with those of IPCC for evaluation and they were found to be of similar level in the case of $CO_2$.

운행차 배출가스 정밀검사 결과를 이용한 휘발유 승용차 대기오염물질 배출량 중 고농도 배출 차량의 기여도 분석 (Quantified Contribution of High Emitting Vehicles to Emission Inventories for Gasoline Passenger Cars based on Inspection and Maintenance Program Data)

  • 이태우;김지영;이종태;김정수
    • 한국대기환경학회지
    • /
    • 제28권4호
    • /
    • pp.396-410
    • /
    • 2012
  • The purpose of this study is to quantify the contribution of high emitting vehicles to mobile emission inventories. Analyzed emission data include $NO_x$, HC, and CO results, which were measured through the vehicle Inspection and Maintenance (I/M) program in Seoul metropolitan area. The high emitting vehicles were identified as the top 5% worst polluting cars of the fleet. We estimated that 5% of the gasoline passenger car fleet, which is high emitters, generated 25.5% of $NO_x$, 34.5% of HC, and 66.1% of CO emissions of total inventories for gasoline passenger car fleet in year 2010. In the study, we identified that the older vehicles (older than ten years) and high mileage vehicles (more than 120,000 km driven) comprised high emitter fleet with 70.9% and 71.2%, respectively. The emission contribution of high emitters became larger in younger fleet than in the older fleet. This is due to the reduced emission rates in newly manufactured vehicles, which were developed under the more stringent emission regulation limits. This analysis implies that high emitters could be responsible for an even larger fraction of total vehicular emissions as more advanced technology vehicles are being incorporated into the current vehicle fleet. The findings suggested that the high emitting vehicles should be primarily considered for in-use vehicle emission management program, such as I/M, accelerated vehicle retirement, or catalytic converter replacement, in order to enhance the effectiveness of selected program.

부산지역에서의 오염물 배출량 산정에 관한 연구 (A Study on the Emission Estimate of Pollutants in Pusan)

  • 김유근;이화운;전병일;방종선
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.361-367
    • /
    • 1996
  • In order to accurately predict air pollution concentration according to reduction of air pollutant emission, a numerical model is needed. And the total emission amount of air pollutants should be estimated to explain the air pollution phenomena. The characteristics of the emission amount from area, line, and point sources in Pusan were studied by using emission data during one year (1992). The result showed that the annual total emission amount of pollutant is about 299,744 tons in Pusan. The emission consists of 31.8% of $SO_2$, 48.4% of CO, 4.6% of HC, 11.0% of NOx and 4.1% of TSP, as well as 52.1% of line, 24.1% of area and 23.7% of point sources. The result also showed that emission amount becomes larger in winter than that of the others.

  • PDF

시멘트 소성시설에서의 수은 배출특성 및 최신 측정방법 적용성 평가 연구 (A Study on the Mercury Emission Characteristic and Comparison Tests for Applicability of Latest Mercury Measuring Methods - Focus on the Cement Kiln -)

  • 김형천;김희진;김종현;강대일;박정민;김정훈
    • 한국대기환경학회지
    • /
    • 제33권3호
    • /
    • pp.241-250
    • /
    • 2017
  • Recently, there has been growing interest in the emission characteristics and behavior of anthropogenic mercury compounds from emission sources. It is required to establish a standard for reliable mercury measurement method. Therefore, this study has evaluated the applicability of the new measurement method; Continuous Emission Monitoring (US EPA 30A, CEM). In addition, the reliability evaluation was conducted through Ontario Hydro Method (ASTM D6784, OHM) and Sorbent trap method (US EPA Method 30B). As a monitoring result for three months via CEM from cement kiln, the maximum mercury compounds concentration was about $600{\mu}g/Sm^3$. This is because of the various of raw materials and fuel, and the absence of mercury-control device. The mercury compounds concentrations of OHM, Sorbent trap and CEM were 13.64 $(3.33{\sim}32.41){\mu}g/Sm^3$, $13.94(5.97{\sim}23.44){\mu}g/Sm^3$ and $14.68(6.19{\sim}26.75){\mu}g/Sm^3$, respectively. The relative standard deviations (% RSD) of the three methods were 5.1~40.9%. The result of this study suggest that it is possible to apply the CEM in the cement kiln when, QA/QC such as calibration is verified.

주행 경로 및 계절의 변화가 소형 경유차의 실제 주행 시 질소산화물 배출량에 미치는 영향 (Influence of Driving Routes and Seasonal Conditions to Real-driving NOx Emissions from Light Diesel Vehicles)

  • 이태우;김지영;박준홍;전상진;이종태;김정수
    • 한국자동차공학회논문집
    • /
    • 제22권1호
    • /
    • pp.148-156
    • /
    • 2014
  • The objective of this study is to compare NOx emissions from light duty diesel vehicles measured from on-road tests that conducted under various driving routes and seasonal conditions. We measured real-driving NOx emissions using PEMS, portable emissions measurement system, under the urban, rural and motorway road traffic conditions. On-road tests were repeated at summer, fall and winter season. The accumulated driving distance is more than 1,200 km per each vehicle. Route average NOx emission factors were compared among nine route-season combinations. The emission characteristics of each combinations were investigated using time series mass emission rates and vehicle operation-based emission rates and activities, which is based on U.S. EPA's MOVES model. Most concerned route-season combination is "urban road condition at summer", which shows two to eleven times higher NOx emissions than other combinations. The emission rates and activities under low speed operating conditions should be managed in order to reduce urban-summer NOx. From a NOx control strategy perspective, the exhaust gas recirculation, EGR, is observed to be properly operated under wide range of vehicle driving conditions in Euro-5 vehicles, even if the air conditioner turns on. In high power demanding conditions, the effect of overspeeding could be more critical than that of air conditioner activation.

배출계수법과 연속자동측정법에 의한 배출량 비교 연구 (A Study on the Comparison of Emission Factor Method and CEMS (Continuous Emission Monitoring System))

  • 장기원;이주형;정성운;강경희;홍지형
    • 한국대기환경학회지
    • /
    • 제25권5호
    • /
    • pp.410-419
    • /
    • 2009
  • Generally, air pollutant emission at workplace is estimated by two methods: indirect methods using emission factors and direct methods based on CEMS (Continuous Emission Monitoring System). CAPSS (Clean Air Policy Support System) is a representative indirect method and the national air pollutant database of Korea. However, characteristics of some workplaces may create a gap between CAPSS and CEMS data. For improving of emission data accuracy, emission data of CEMS (named CleanSYS) equipped at 138 target workplaces were compared with those of CAPSS. As a result, $SO_x$ and $PM_{10}$ emission levels obtained by CAPSS were lower than those of CleanSYS. $SO_x$ and $PM_{10}$emission ratios were 61.5% and 71.2% lower respectively, showing the biggest gaps. On the other hand, $NO_x$ emission of CAPSS was higher by 10.4%. $SO_x$ showed the biggest difference in 'Energy industry combustion' and $NO_x$ did in 'Production Process' within the SCC category. $PM_{10}$ presented a large gap in 'Manufacturing industry combustion.' The differences in $SO_x$ between the two systems occurred because some large-size facilities lack pollution controllers or efficient pollution controllers. Based on this study, CAPSS emission database of Korea will improve accuracy through adopting CEMS emission system, which enables more efficient national atmospheric policies and workplace management.

GIS를 이용한 대기오염정보시스템 개발에 관한 연구 (A Study on Developing Environmental Information Systems for Presenting Air Pollution Emission Data Using GIS)

  • 이봉규
    • 한국공간정보시스템학회 논문지
    • /
    • 제1권1호
    • /
    • pp.39-48
    • /
    • 1999
  • 본 논문은 GIS를 이용하여 대기오염도 정보를 전달하는 환경정보시스템을 연구하는 것을 목적으로 한다. 본 연구에서는 ArcView 3.1과 수치지도를 이용하여 환경정보시스템을 개발하였다. 본 논문은 4장으로 구성되어 있는데, 서론에 이어 제2장에서는 대기오염정보 전달시스템의 현황을 서울시를 중심으로 살펴본다. 제3장에서는 본 연구를 통해 구현된 인터페이스와 시스템을 설명하고, 마지막 장에서는 요약으로 결론을 맺기로 한다.

  • PDF

노천소각에서 배출되는 먼지 배출계수 산정에 관한 연구 (Estimation of Particulate Matter Emission Factors from Open Burning)

  • 정노을;조명란;허선화;김형천;박정민;이대균;홍지형;이석조;이영재
    • 한국대기환경학회지
    • /
    • 제28권3호
    • /
    • pp.348-356
    • /
    • 2012
  • It is very important to investigate air pollutants and emissions emitted from open burning in order to control nonpoint sources effectively. In this study, we utilized incineration simulator proposed by U.S. EPA and investigated concentrations of TSP, PM10, PM2.5 from woods and household wastes burning to calculate emission factors and build emission inventories. The results of experiment with 15 kg of woods and 3 kg of household wastes using the incineration simulator were as follows: in case of woods burning, TSP concentration was $66.4mg/m^3$, PM10 concentration was $28.4mg/m^3$, PM2.5 concentration was $17.9mg/m^3$, respectively; in case of household wastes burning, TSP concentration was $118.4mg/m^3$, PM10 concentration was $66.8mg/m^3$, PM2.5 concentration was $55.2mg/m^3$, respectively. Concentrations from household burning, as stated above, were higher than those from woods burning. Emission factors (EFs) for woods and household wastes burning were calculated as 2.45 and 6.75 g/kg for TSP, 0.86 and 5.45 g/kg for PM10, 0.78 and 4.81 g/kg for PM2.5, respectively. EFs of TSP, PM10, PM2.5 calculated from household wastes burning were higher than those of woods burning. When we added PM emissions from woods burning and household wastes burning to Korean National Emission Inventory named as Clean Air Policy Support System (CAPSS), CAPSS annual emissions of TSP, PM10, PM2.5 were increased by 0.08~0.26% (An increase rate for TSP, PM10, PM2.5 were 0.08~0.10%, 0.16~0.20% and 0.18~0.26%, respectively). Note that we assumed that the 1% of household wastes is emitted by open burning.

저온 플라즈마 장치를 이용한 디젤기관의 유해배출물질 저감에 관한 실험적 연구 (An Experimental Study on the Reduction of Diesel Emission Using Low Temperature Plasma Apparatus)

  • 김홍석;원준희;정태용
    • 한국자동차공학회논문집
    • /
    • 제8권5호
    • /
    • pp.12-19
    • /
    • 2000
  • The increasing use of vehicles is causing air-pollution problems. Diesel vehicles are preferred to gasoline vehicles, because the diesel vehicles are superior to gasoline vehicles in terms of fuel consumption, durability, power and efficiency. But the emission reduction technologies for diesel vehicle are not developed well like those for gasoline vehicles. Moreover, the NOx and smoke emitted from diesel vehicle are recognized as a main source of the air-pollution in the urban areas. The emission reduction devices have been installed for each of the emission gas components. Using plasma(i.e. electrical energy)only, the emission gas was found to be reduced. The present paper investigate the effects of a low temperature plasma device in engine performance as well as in emission reduction with the change of the applied voltage and the loading rate of the engine.

  • PDF