Case Study: Operation of the Juam Constructed Wetland for Effluent from a Sewage Treatment Plant and Diffuse Pollution for Two Years (하수종말처리장 방류수와 비점오염원 처리를 위한 주암호 인공습지 2년 운영 사례)

  • Jung, Yong-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1031-1037
    • /
    • 2006
  • In order to improve water quality of the Juam Lake, a constructed wetland was implemented and operated for 2 years with the effluent of sewage treatment plant and diffuse pollutant discharged from agricultural area. During the summer season, average removal efficiencies for BOD and SS were 15.8% and 39.4%, respectively. Due to the mixed effect of vegetation, soil microbes and sediments, the higher nutrient removal efficiencies were obtained: average T-N and T-P removal efficiencies were 64.2% and 71.7%, respectively. The concentration of sediment was increased initially, and maintained constant throughout monitoring period. The highest nitrogen and phosphorus uptake were observed in Phragmites japonica. The nitrogen uptake was estimated as 0.235 DW mg/g while phosphorus uptake was estimated as 2.059 DW mg/g.

The Study of DAF-System to Apply the CSOs Treatment (CSOs의 오염물질 제거시 DAF-system의 적용에 관한 연구)

  • Lee, Tae-Gwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.385-391
    • /
    • 2004
  • This paper examines the applicability of DAF-system to the domestic sewers for the effective CSOs treatment. The procedures for the experiment include mainly two steps. One is to analyse the water qualities and settling test of the CSOs and the other focuses on general characteristics of the CSOs such as the removal efficiency of pollutant, the distribution of particle size and mass balance of DAF-system. The result of this study show that the application of DAF-system is more effective and economical than the existing treatment systems because it has two removal mechanisms of sedimentation and flotation simultaneously.

The Comparison of Disinfection Technologies for Managing Antibiotic Resistance ; Chlrorination, Ozonation and Electron Beam (항생제 내성 제어를 위한 소독 기법간의 비교 ; 염소, 오존 및 전자빔)

  • Oh, Junsik;Kim, Sungpyo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.797-803
    • /
    • 2013
  • Recently, a number of countries are now considering the reuse of effluents from wastewater treatment for various water applications. To improve the reuse of wastewater effluent, the development of appropriate micro-pollutant removal technology is necessary. Although several researche have been studied for removing micro-pollutants in water, little study has been conducted for the removal of emerging contaminant such as antibiotic resistant genes (ARGs) by disinfection processes. Therefore, the aim of this study is to compare the capacity of disinfection technologies such as chlorination, ozone, and electron beam, for removing antibiotic resistant bacteria (ARB) and ARGs. Based on this study, better ARG removal can be achieved by ozonation and electron beam. Relatively, high CT values of chlorination or ozonation are needed to remove ARB and ARG compared to conventional pathogens.

Characteristics of Phenol Degradation by Fenton Treatment (Fenton 처리에 의한 페놀의 분해 특성)

  • 최석순;염승호;차형준
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.29-35
    • /
    • 1997
  • Phenol, often discharged from petroleum and fine chemical industries is potential carcinogen and was classified into priority pollutant by EPA in USA. It causes serious environmental and health problem if discharged to the environment such as soil or aquifer. The removal efficiency of phenol and COD using Fenton treatment(Hydrogen Peroxide and Ferrous Sulfate) was observed and biodegradability (BOD$_{5}$/COD$_{cr}$) of reaction products were also examined. When 50 mg/l of phenol was treated by Fenton's Reagent(50 mg/l of hydrogen peroxide and 900 mg/l of ferrous sulfate), the removal efficiency of phenol and COD was 100% and 80% respectively in 10 minutes, which suggested this method can be used as actual phenol removal process. The initial biodegradability of 500 mg/l phenol solution was 0.7 but decreased as hydrogen peroxide was increased.

  • PDF

Water Treatment Characteristics by Const ucted Wetland with Different Vegetation - Open Water Arrangements (식생습지와 개방수역의 배열에 따른 인공습지의 수처리 특성)

  • Jang, Jeong-Ryeol;Choi, Sun-Hwa;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.122-130
    • /
    • 2007
  • This study was conducted to evaluate water treatment characteristics according to vegetated wetland(V) and open water(O) arrangements in free water surface constructed wetland. Three pilot-scale wetlands, V-V, O-V and V-O, were built and operated. $BOD_5$ was a slightly reduced at all the arrangements because the influent concentration was so low as background concentration of constructed wetlands. While T-N and T-P removal efficiency showed higher than 50% for all cases. The O-V arrangement showed the highest removal efficiency: 20% for $BOD_5$, 56% for SS, 59% for T-N and 72% for T-P. Effluent concentration of the O-V were significantly low compared with those from the V-O. O-V arrangement would be beneficial in the light of pollutant removal efficiency as well as construction cost.

Development of the Inorganic Paint Using Blast Furnace Slag$\cdot$Photocatalytic Carrier and the Removal Property of NOx and Indoor a Pollutant (고로슬래그$\cdot$광촉매담체를 이용한 무기도료의 개발과 질소산화물 및 실내오염물질의 제거 특성에 관한 연구)

  • Chai Han sik;Lee Jun-cheol;Kim Wha-Jung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.385-388
    • /
    • 2005
  • In this study, the objective is to develope environment friendship mineral pigments for removal of harmful chemical substance. Environment friendship mineral pigments made of Slag blast furnace-photocatalyst carriers were developed to identify their removal effects of NOx, HCHO and VOCs(benzene, Toluene) on sunlight, fluorescent light and UV lamp. In case of NOx at UV light, the eliminative ability was been better than different harmful materials, and it was appeared large degree rather than different harmful materials.

  • PDF

BASELINE MEASUREMENTS ON THE PERFORMANCE OF FOUR CONSTRUCTED WETLANDS IN TROPICAL AUSTRALIA

  • Fell, A.;Jegatheesan, V.;Sadler, A.;Lee, S.H.
    • Environmental Engineering Research
    • /
    • v.10 no.6
    • /
    • pp.316-327
    • /
    • 2005
  • Constructed wetlands provide several benefits that are not solely limited to storm water management and are becoming common in storm water management. In this research, four recently constructed wetlands underwent in situ and laboratory water sampling to determine their efficiency in removing storm water pollutants over a 5-month period. From the sampling results, it was determined that each of the wetlands was able to reduce the concentration of pollutants in the stormwater. To aid in the assessment of the wetlands against each other, a model was developed to determine the extent of removal of stormwater pollutants over the length of the wetland. The results from this model complimented the data collected from the field. Improvements, such as increased amounts of vegetation were recommended for the wetlands with the aim of increasing the effectiveness. Further investigations into the wetlands will allow for better understanding of the wetland's performance.

Effect of Nano-Bubble on Removal of Complex Heavy Metals (나노버블이 복합중금속(구리/납) 오염물 제거에 미치는 영향 분석)

  • Lee, Yang-Gyu;Han, Jung-Geun;Choi, Ju-Hyun;Kim, Dong-Chan;You, Seung-Kyong;Hong, Kikwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.139-146
    • /
    • 2015
  • This paper describes a effect of nano-bubble on removal of complex heavy metals, in order to remove pollutants of soil with copper (Cu) and lead (Pb) based on column test. It was conducted column test considering inflow and fine soil contents condition, and then it was analyzed removal effect of nano-bubble on Cu and Cu/Pb. The test result showed that the removal effect of the nano-bubble was higher than that of distilled water regardless of fine soil contents in case of Cu pollutant, and the removal effect of nano-bubble on heavy metals was found to have a significant impact on Pb than Cu in case of Cu/Pb pollutants. It was also analyzed that engineering properties (like a flow path and permeability) of soil due to void ratio has influenced a significant impact the pollutants removal of nano-bubble. The test results determined that nano-bubble can be applied as a flushing agent for priority target pollutant in complex heavy metals.

Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants (산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건)

  • 백경렬;구자공
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

Bacterial Dynamics of Biofilm Development During Toluene Degradation by Burkholderia vietnamiensis G4 in a Gas Phase Membrane Bioreactor

  • Kumar, Amit;Dewulf, Jo;Wiele, Tom Van De;Langenhove, Herman Van
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.9
    • /
    • pp.1028-1033
    • /
    • 2009
  • In this study, the dynamics of living cells (LC) and dead cells (DC) in a laboratory-scale biofilm membrane bioreactor for waste gas treatment was examined. Toluene was used as a model pollutant. The bacterial cells were enumerated as fluoromicroscopic counts during a 140 operating day period using BacLight nucleic acid staining in combination with epifluorescence and confocal laser scanning microscopy (CSLM). Overall, five different phases could be distinguished during the biofilm development: (A) cell attachment, (B) pollutant limitation, (C) biofilm establishment and colonization, (D) colonized biofilm, and (E) biofilm erosion. The bioreactor was operated under different conditions by applying different pollutant concentrations. An optimum toluene removal of 89% was observed at a loading rate of 14.4 kg $m^{-3}d^{-1}$. A direct correlation between the biodegradation rate of the reactor and the dynamics of biofilm development could be demonstrated. This study shows the first description of biofilm development during gaseous toluene degradation in MBR.