• Title/Summary/Keyword: Pollutant load

Search Result 480, Processing Time 0.036 seconds

Contamination of the Mushim-Cheon and its Countermeasures;I. Analysis of the Water Samples in Summer (무심천 수질 오염 실태와 그 방지책;I. 하계절의 수질 오염 분석)

  • Lee, Jea-Koo;Kyung, Kee-Sung;Kim, Hak-Nam;Oh, Kyeong-Seok
    • Korean Journal of Environmental Agriculture
    • /
    • v.9 no.1
    • /
    • pp.23-37
    • /
    • 1990
  • In order to disclose the contamination of the Mushim-Cheon by pollutants in August and September of 1989 and to establish countermeasures, the collected water samples were analyzed to obtain the following results : 1. The water temperature of the period ranged from 25.8 to $30.8^{\circ}C$ acceptable for the growth of microorganisms and algae to allow the self-purification of the stream. 2. The pHs at the sites during the same period ranged from 6.5 to 8.5 which fall within the allowed values for the first grade water supplies except for site 14. 3. At site 18 which is the confluence of the sewer of the excretion disposal facilities and the main stream, the DO was observed to fall down to 0.7 ppm in September. 4. The BOD value reached a maximum of 62.1 ppm at site 18, which far exceeded the limit of 40 ppm, the allowed value for the discharges from the disposal facilities. In addition, the SS values were 200 and 520 ppm in August and September, respectively, which were three to seven times as high as the allowed limit of 70 ppm. 5. The high $NH_3-N$ value of 46.2 ppm at site 18 in September suggested that the water was heavily contaminated with excretions. 6. The BOD load of the sewage from site 12, the Sajik-Dong Sewer, in September was estimated to be about 0.306 ton/day. 7. The contamination of the influents, the family wastewater, and the discharges from the disposal facilities was greater than that of the main stream. 8. In the samples collected from site 12, the Sajik-Dong sewer at an interval of every two hours, a close correlation was observed between the pollutant load and the life cycle of the nearby inhabitants. 9. Compared with the results obtained from the water samples in 1979, it was observed that the water was heavily contaminated at site 12 (the Sajik-Dong Sewer, under the Chung Ju Great Bridge) and site 15 (Under the 2nd Uncheon Bridge) over the last 10 years, with little difference at site 9(Young Un-Dong water supply source).

  • PDF

Reduction of Pollutant Load by Small Pond in a Rice Paddy Applied with Pig Manure Compost (돈분퇴비가 시용된 논의 양분유출 저감을 위한 저류지 효과)

  • Kim, Min-Kyeong;Kim, Myung-Hyun;Choi, Soon-Kun;Cho, Kwang-Jin;Hong, Seong-Chang;Jung, Goo-Bok;So, Kyu-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.4
    • /
    • pp.21-27
    • /
    • 2014
  • Pig slurry has been considered as environmental waste to be treated in an appropriate manner. Moreover, water-born pollution loads by agricultural non-point source(NPS) pollution are expected to become intensified due to ongoing precipitation change. This study was conducted to develop a best management practice to reduce NPS pollution load by agricultural activity with pig manure compost. An eco-friendly way, small drainage pond, was suggested in this study to avoid direct drainage of agricultural runoffs and eventually reduce the amount of pollutants discharged into the surrounding aqua-environment. A small pond($12m^2$) was constructed at the corner of a rice paddy field($17,15m^2$) located in Suwon, Korea. Water was allowed to drain only via a small drainage pond. Sampling was repeatedly made at two locations, one from an entrance and the other from an exit of a pond, during the rice cultivation period(May to October, 2013). Generally, sampling was made only when runoff water drained through a pond, such as during and/or after rain(irrigation). The water quality analysis showed that all quality parameters(SS, $COD_{Mn}$, T-N, and T-P) were improved as water passed through the pond. The amount of runoff water was reduced by 67.8%. Suspended solids and $COD_{Mn}$ concentrations were reduced by 79.8% and 71.9%, respectively. In case of T-N and T-P amounts, the reduction rates were 73.6% and 74.9%, respectively. Our data implies that agricultural NPS pollution from rice paddy fields with pig manure-based fertilizer can be effectively managed when an appropriate drainage water management practice is imposed.

Distribution of Organic Matter and Heavy Metals in the Surface Sediments from Fishery Resources Protection Areas in the Southwestern Coast of Korea (남서해연안 수산자원보호구역 표층 퇴적물 중 유기물 및 중금속 농도분포)

  • Koo, Jun-Ho;Lee, Garam;Hwang, Hyunjin;Kim, Jeong-Bae;Kim, Sang-Su;Hwang, Dong-Woon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.6
    • /
    • pp.666-677
    • /
    • 2019
  • In order to understand the distribution of organic matter and heavy metal concentrations in the surface sediments of fishery resources protection areas (FRPAs), we measured the grain size, ignition loss (IL), chemical oxygen demand (COD), acid volatile sulfide (AVS), and concentrations of heavy metals (As, Cd, Cr, Cu, Fe, Hg, Pb, and Zn) in the surface sediments collected at 54 stations of 5 FRPAs (Gamak Bay, Yeoja Bay, Deukryang Bay, Wando coast, and Youngkwang coast) in the southwestern coast of Korea in February 2017. The surface sediments consisted of fine sediment such as mud, with 2.9~8.8Ø (7.4±0.1Ø) of mean grain size. The average concentrations of IL, COD, and AVS in the sediments were 4.63±0.96 %, 13.0±3.1 mgO2/g·dry, and 0.092±0.124 mgS/g·dry, respectively, and were lower for sediments from the Youngkwang coast than those from other FRPAs. The average concentrations of heavy metals in the sediment were 7.5±0.9 mg/kg for As, 0.04±0.02 mg/kg for Cd, 70.2±9.7 mg/kg for Cr, 15.3±2.8 mg/kg for Cu, 3.3±0.5 % for Fe, 0.014±0.003 mg/kg for Hg, 25.0±6.0 mg/kg for Pb, and 99±14 mg/kg for Zn, respectively, and were relatively higher for sediments in the inner bays than those from the outer bays and coasts. Based on the assessment of sediment samples using the sediment quality guidelines (SQGs), the pollutant load index (PLI), and the ecological risk index (ERI), the surface sediments of FRPAs in the southwestern coast of Korea do not appear to be polluted by heavy metals, suggesting that the heavy metal concentrations in the sediments would not adversely impact aquatic and benthic organisms.

Comparison of Removal Efficiencies in Single and Duplex Ventilation Constructed Wetland Systems for Treating Domestic Sewage (단일 통풍형과 이중 통풍형 인공습지시스템의 하수처리 효율 비교)

  • Seo, Dong-Cheol;Lim, Seok-Cheon;Jo, In-Seong;Lee, Byeong-Ju;Lee, Hong-Jae;Kim, Sang-Don;Lee, Jun-Bae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.3
    • /
    • pp.258-265
    • /
    • 2009
  • To develop environmentally friendly constructed wetlands(CWs) for treating domestic sewage which was produced in farming and fishing village, the efficiency of water treatment at different ventilation systems in the vertical bed, depths of horizontal bed, and sewage loads was investigated. In the vertical bed, BOD and COD by duplex ventilation system were lower than those by single ventilation system. But T-N and T-P concentrations by both ventilation systems in the vertical bed were little different. In the horizontal bed, BOD, COD, T-N and T-P in 1.0 m and 1.3 m depths were little different. To reduce the CWs' area and to improve the pollutant removal efficiencies, the optimum depth of horizontal bed was 1.3 m. In single and duplex ventilation CWs, the removal rate of BOD, COD, SS, T-N and T-P decreased slightly with the sewage load increases. In same sewage load conditions, the removal rates of BOD, COD, SS, T-N and T-P by duplex ventilation CWs were higher than those by single ventilation CWs. In summary, to effectively treat domestic sewage from farming and fishing village, the optimum constructed wetlands would be the duplex ventilation CWs.

The impact of anthropogenic factors on changes in discharge and quality of water in the Hadano basin, Japan (인위적인 요인이 하천의 유량과 수질변화에 미친 영향 - 일본 하다노 분지를 사례 로 -)

  • ;Yang, Hea-Kun
    • Journal of the Korean Geographical Society
    • /
    • v.30 no.3
    • /
    • pp.242-254
    • /
    • 1995
  • The Hadano Basin is located at a distance of about 70kms and 60kms from Tokyo and Yokohama and lies in the south-west part of the Kanto region in Japan. The basin area, which correspoends to the catchment of the Kaname River, is about areal size of 60.7$\textrm{km}^2$ and extends about length of 8kms in E-W direction and about width of 5kms in N-S direction (Fig.1). The Hadano basin is filled with thick pile of the alluvum from deposits composed of volcanic materials, mostly came from the Hakone Volcano and overlain by Fuji Volcanic ashes. Fluvial deposits form the good aquifer, therefore water resources of Handano City has been largely depending upon the eroundwater. Urbanization and industrialization of the basin has been rapid in the last thirty years, after activation of "Factory Attraction Policy of Hadano City" in 1956. Growth in population and number of factory due to urbanization changed the land-use pattern of the basin rapidly and increased the water demands. Therefore, Hadano City exploited a new source of water supply, and have introduced the prefectureal waterworks since 1976. On the other hand, the rapid urbanization has brought about the pollution of streams in the basin by domestic sewage and industrial waste water. Diffusion rate of sewerage systems in Hadano City is 38% in 1993. In ordcr to examine the impact of anthropogenic factors on river environments, the author took up the change of land-use and diffusion area of sewerage as parameters, and performed field surveys on water discharge and quality. The survey has been made at upstream and downstream of the main stream regularly per month, to get informati ons about the variation of discharge and water quality aiong the stream and its diurnal fluctuation. Annual variation has been analyzed based the data from Hadano City Office. The results are summarized as follows. 1. Stream discharge has been increasing by urbanization (Fig.3). Water quality (C $l^{-10}$ , N $H^{+}$$_{ 4}$-N, BOD) has been improving gradually after the application of sewerage service, yet water pollution load at the lower station has increased than that at the upper one because of the larger anthropogenic discharge volumes (Fig.4). 2. Corrclation coefficient of discharges between upper and lower was 0.81-0.92. Pollutant loads of the R. Kamame after the confluence with R. Kuzuha grew up by 2.4-3.7 times as compared with its upper reaches, and it increased to 3.7-6.9 times after the confluence with the R. Muro (Fig.5). 3. The changes of water quality along the stream can be divided into two groups (Fig.6a). First: water quality of the R. Kaname and R. Shijuhachisse is becoming worse towards the lower reaches because the water from branches are polluted. Second: water quality are improved in the lower where spring and small branch streams supply clear water, for example R. Mizunashi, R. Muro and R. Kuzuha. 4. Measured discharge at the upper station in the R. Shijuhachisse is 0.153㎥/sec, and about 55% of this is recharged until it reaches to the lower point. The R. Mizunashi has a discharge of 1.155㎥/sec at the upper point, is recharged 0.24㎥/sec until the midstream and groundwater spring 0.2㎥/sec at the lower reaches. R. Kuzuha recharged all the mountain runoff (0.2㎥/sec) at the upper reaches. The R. Muro is supplied by many springs and the estimated discharge of spring was 0.47㎥/sec (Fig.6b). 5. Diurmal variations in discharge and water quality are influenced clearly by domestic and industrial waste waters (Fig.7, 8).ed clearly by domestic and industrial waste waters (Fig.7, 8).

  • PDF

Water Quality and Structure of Aquatic Ecosystem in Water Source, Lake Gachang (상수원 호소인 가창호의 수질과 수생태계의 계절적 변화)

  • Park, Yeon-Jeong;Lee, Hae-Jin;Seo, Jung-Kwan;Tak, Bo-Mi;Jeong, Hyun-Gi;Lee, Jae-Kwan
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.4
    • /
    • pp.296-304
    • /
    • 2011
  • This study was carried out to investigate the relation between water quality and structure of the aquatic ecosystem in the Lake Gachang from February to December in 2010. The annual mean COD (Chemical Oxygen Demand) in Lake Gachang was 3.5 mg $L^{-1}$, indicating, level II of environmental standards and the trophic state was mesotrophic. The seasonal succession of phytoplankton showed that Bacillariophyceae was mostly dominant species throughout the year except August. In case of zooplankton, rotifers dominate in the most seasons, but copepod (Nauplii) in August. The macrophyte plants showed diverse species composition consisted of 9 varieties, 77 species, 64 genera, 34 families and 24 orders. Surveyed species of macroinvertebrates were classified into 1 phyla, 2 classes, 4 orders, 7 families, 9 species. The macroinvertebrates showed FFG (Functional Feeding Groups) such as GC (Gathering-Collector) and SH (Shedder). A total of 42 species of fish was collected including $Zacco$ $koreanus$ and $Coreoperca$ $herzi$. In this study, we investigated environmental factors including pollutant source, load, water quality and distribution characteristics of biota such as phytoplankton, zooplankton, macrophyte plants, macroinvertebrates, fish.

Long-Term Variations of Water Quality in Jinhae Bay (진해만의 장기 수질변동 특성)

  • Kwon, Jung-No;Lee, Jangho;Kim, Youngsug;Lim, Jae-Hyun;Choi, Tae-Jun;Ye, Mi-Ju;Jun, Ji-Won;Kim, Seulmin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.4
    • /
    • pp.324-332
    • /
    • 2014
  • In order to reveal the long-term variations of water quality in Jinhae Bay, water qualities had been monitored at 9 survey stations of Jinhae Bay during 2000~2012. The surface and bottom waters concentrations of chemical oxygen demand (COD), dissolved inorganic nitrogen (DIN), dissolved inorganic phosphorus (DIP), and chlorophyll-a (Chl.-a) were higher at the survey stations of Masan Bay than the stations of other Bays. Especially, station 1 which is located at the inner area of Masan Bay had the highest values in the concentrations of COD, DIN, and Chl.-a because there were terrestrial pollutant sources near the station 1 and sea current had not well circulated in the inner area of Masan Bay. In factor analysis, the station 1 also had the highest factor values related to factors which increase organic matters and nutrients in surface and bottom waters of Masan Bay. However, the stations (st.5, st.6, st.7, st.8, and st.9) of other Bays had lower values of the factors. In time series analysis, the COD concentrations of the bottom waters at 8 stations except for station 1 distinctly decreased. However, the COD concentrations of the surface waters showed no distinct decrease trends at all stations. In the concentrations of nutrients (DIN and DIP) of both surface and bottom waters, there were tremendous decrease trends at all stations. Therefore, these distinct decrease trends of the COD in bottom waters and the nutrients in surface and bottom waters of Jinhae Bay could have been associated with water improvement actions such as TPLMS (total pollution load management system).

Distributions of Organic Matter and Heavy Metals in the Surface Sediment of Jaran Bay, Korea (자란만 표층 퇴적물 중 유기물과 중금속 농도분포)

  • Hwang, Hyunjin;Hwang, Dong-Woon;Lee, Garam;Kim, Hyung-Chul;Kwon, Jung-No
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.1
    • /
    • pp.78-91
    • /
    • 2018
  • In order to understand the distributions of organic matter and heavy metal concentrations in the surface sediment of Jaran Bay, we measured the grain size, total organic carbon (TOC), total nitrogen (TN), and heavy metals (As, Cd, Cr, Cu, Fe, Hg, Mn, Pb, and Zn) in surface sediments collected at 15 stations in this bay in November 2014. The sediment consisted of finer sediment such as mud and clay, with 8.6-9.8Ø($9.3{\pm}0.3$Ø) of mean grain size. The concentrations of TOC and TN in the sediment ranged from 1.51-2.39 % ($1.74{\pm}0.22%$) and 0.20-0.33 % ($0.23{\pm}0.03%$), respectively, and did not show spatial difference. The carbon to nitrogen ratio (C/N ratio) ranged from 5-10, indicating that organic matter in the sediment originated from oceanic sources such as animal by-products from fish and shellfish farms. The concentrations of Cr, Fe, and Mn were much higher in the mouth of the bay than in the inner bay, and the concentrations of As, Cd, Cu, Hg, Pb, and Zn showed an opposite distribution pattern. Based on the results of the sediment quality guidelines (SQGs), enrichment factor (EF), geoaccumulation index ($I_{geo}$), pollutant load index (PLI), and ecological risk index (ERI), the surface sediment in Jaran Bay is not polluted or only slightly polluted with Cd, Cr, Cu, Hg, Pb, and Zn, whereas it is moderately to strongly polluted with As. In particular, some regions in the bay were identified as having a considerable risk status, indicating that metal concentration in the sediment could impact benthic organisms. Thus, the systematic management for marine and land sources of organic matter and heavy metals around Jaran Bay is necessary in order to ensure seafood safety and maintain sustainable production on shellfish farms.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

The Effective Approach for Non-Point Source Management (효과적인 비점오염원관리를 위한 접근 방향)

  • Park, Jae Hong;Ryu, Jichul;Shin, Dong Seok;Lee, Jae Kwan
    • Journal of Wetlands Research
    • /
    • v.21 no.2
    • /
    • pp.140-146
    • /
    • 2019
  • In order to manage non-point sources, the paradigm of the system should be changed so that the management of non-point sources will be systematized from the beginning of the use and development of the land. It is necessary to change the method of national subsidy support and poeration plan for the non-point source management area. In order to increase the effectiveness of the non-point source reduction project, it is necessary to provide a minimum support ratio and to provide additional support according to the performance of the local government. A new system should be established to evaluate the performance of non-point source reduction projects and to monitor the operational effectiveness. It is necessary to establish the related rules that can lead the local government to take responsible administration so that the local governments faithfully carry out the non-point source reduction project and achieve the planned achievement and become the sustainable maintenance. Alternative solutions are needed, such as problems with the use of $100{\mu}m$ filter in automatic sampling and analysis, timely acquisition of water sampling and analysis during rainfall, and effective management of non-point sources network operation management. As an alternative, it is necessary to consider improving the performance of sampling and analysis equipment, and operate the base station. In addition, countermeasures are needed if the amount of pollutant reduction according to the non-point source reduction facility promoted by the national subsidy is required to be used as the development load of the TMDLs. As an alternative, it is possible to consider supporting incentive type of part of the maintenance cost of the non-point source reduction facility depending on the amount of pollutants reduction.