• 제목/요약/키워드: Pole transformer

검색결과 108건 처리시간 0.028초

식물성절연유의 주상변압기 적용 연구 (Study on Vegetable Oil Application of the Pole Transformer)

  • 곽동순;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.169-171
    • /
    • 2009
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. For development of the environmental-friendly pole transformer using vegetable oil, we discussed the insulation construction of the transformer and the dielectric characteristics of the Nomex insulation paper in vegetable oil. Based on the experimental data, the insulation of the transformer is designed.

  • PDF

이동통신망의 SMS 방식을 이용한 주상변압기 무선 진단 기법 (Wireless Diagnostic Technique for Pole Transformer Using SMS of Mobile Telecommunication Network)

  • 김진철;이향범
    • 정보통신설비학회논문지
    • /
    • 제2권3호
    • /
    • pp.61-71
    • /
    • 2003
  • 본 논문에서는 이동통신망의 SMS 방식을 이용하여 소용량 변전기기인 주상 변압기의 상태를 진단함으로써 발생 가능한 변압기의 사고를 사전에 방지할 수 있는 시스템에 관하여 연구하였다. 변압기의 전류와 온도를 취득하여, 과부하 상태의 값들을 평균과 표준편차로 정리하여 보내는 방식의 무선진단에 적합한 알고리즘 및 프로토콜을 설계하였다. 이동통신망의 SMS방식을 이용하여 유선의 단점인 설치장소에 대한 장애를 없앴다. 또한, 1대의 서버로 많은 수의 변압기를 관리, 제어, 모니터링이 가능하도록 하였다.

  • PDF

일체형 주상용 몰드 변압기의 온도분포 및 특성 비교 (Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding)

  • 조한구;이운용;강택수;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

주상변압기 고압권선의 서지응답 특성 (Electrical Characteristics of Insulation Paper for Distribution Transformers)

  • 송일근;정종욱;이병성;이재봉;김상준;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.156-159
    • /
    • 2002
  • This paper presents an experimental study of the surge response characteristics for the primary winding of a pole transformer and ultimately aims at devising countermeasures against the surge in operating transformer. After applying the impulse voltage to the primary of the 30 kVA pole transformer with single bushing, the voltage waveforms were measured at each tap lead and compared with one another. As a result, the voltage peak of the surge propagating in the primary was decreased in magnitude at a constant rate and somewhat delayed compared to the peak of the applied surge as the tap leads were getting closer to the grounding terminal. The voltage measured at the secondary was not delayed in time, different from that at the primary, and it was about 1/6 according to the turn ratio.

  • PDF

자동 탭 절환 내장형 주상변압기 개발에 관한 연구 (Development Pole Transformer with Automatic Tap Changer)

  • 남궁원;이성우;장문종
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.108-113
    • /
    • 2013
  • Change of supply voltage, customer load, output of distributed generation, etc cause voltage change in distribution system. OLTC and SVR are usually used to supply normal voltage at customer. But usage of these devices is inefficient and uneconomical in certain circumstances. To solve this problem, new pole transformer which has automatic tap changer is developed. The transformer changes tap when voltage changes. And it has latch switch and reactor for supplying power without outage. To verify normal operation of tap changer, test is conducted. SVR and 50kVA load is used for test.

주상용 몰드변압기의 온도분포 해석과 온도상승 시험 (The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer)

  • 조한구;이운용;김석수;이종득
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.780-782
    • /
    • 2001
  • The mold transformer has anti-burnt and possibility of small size contrary to oil-immersed transformer. The mold transformer has generally cooling duct between low voltage coil and high voltage coil and also made by one body molding for small size and low loss. In this paper, the temperature distribution of designed 50kVA pole mold transformer for power distribution is investigated by FEM program. The designed transformer is also manufactured and temperature rise test is carried out.

  • PDF

주상용 몰드변압기의 온도분포와 열응력 해석 (The Temperature Distribution and Thermal Stress Analysis of Mold transformer)

  • 조한구;이운용;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2000
  • The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. Therefore design time and design cost are decreased by numerical analysis. In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The temperature change according to load rates of transformer also have been investigated. We have carried out temperature rise test and test results are compared with simulation data.

  • PDF

원통형 캐비티에서 방출되는 방사 전자파 특성 (Characteristics of Radiated Electromagnetic Fields From A Cylindrical Cavity)

  • 김효균;조준호;임동영;김기채
    • 한국정보통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.237-244
    • /
    • 2016
  • 본 논문에서는 주상변압기의 내부 부분방전에 의한 방사 전자파를 예측하기 위해 원통형 캐비티의 구조 및 크기 변화에 따른 1차측, 2차측 전극의 부싱을 통해 방출되는 방사 전자파 특성을 FDTD 법으로 검토하였다. 그 결과, 원통형 캐비티의 구조에서 1차측 및 2차측 부싱에서 방사되는 방사 전자파를 확인할 수 있었다. 원통형 캐비티 외함의 구조에 대한 방사 전자파의 주파수 특성을 검토하고 제작한 원통형 캐비티의 실험을 통해 이론 계산 결과와 비교 검토하였다.

수용가 냉방부하를 고려한 하절기 주상변압기 최대부하 추정 (Peak Load Estimation of Pole-Transformer in Summer Season Considering the Cooling Load of Customer)

  • 윤상윤;김재철;김기현;임진순
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, we propose a method for estimating the peak load of pole-transformer in summer season considering the degree of cooling load possession in customer. The cooling load of customer is selected as the most reliable parameter of peak load in summer season. The proposed estimation method is restricted to the aspect of load management for pole-transformer. The main concept of proposed method is that the error of peak load estimation using load regression equation reduces with considering the degree of cooling load possession in customer. We propose an index for estimation of cooling load possession in each customer. The proposed index is defined as cooling load possession in customer (CLPC) and obtained from the increment of monthly electric energy. The membership function for deciding the uncertainty of cooling load possession in customer is used. The database of pole-transformer in Korea Electric Power Corporation (KEPCO) is used for case studies. Through the case studies, we verify that the proposed method reduces the error of peak load estimation than the conventional method in domestic.

  • PDF

주상용 몰드 변압기의 온도분포 해석과 온도상승 시험 (The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer)

  • 조한구;김석수;이운용;이종득
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.245-247
    • /
    • 2001
  • In this paper, the temperature distribution and thermal stress analysis of 50kVA pole mold transformer for power distribution are investigated by FEM program. The temperature rise test of designed mold transformer is carried out and test result is analyzed compare to simulation data.

  • PDF