• Title/Summary/Keyword: Polarization Curves

Search Result 222, Processing Time 0.019 seconds

Electrochemical Evaluation on Corrosion Resistance of Anti-corrosive Paints

  • Moon, Kyung-Man;Lee, Myung-Hoon;Kim, Yun-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.387-394
    • /
    • 2009
  • It has been observed that coated steel structures are rapidly deteriorated than designed lifetime due to acid rain caused by air pollution etc.. Therefore improvement of corrosion resistance of anti-corrosive paint is very important in terms of safety and economic point of view. In this study corrosion resistance for five kinds of anti-corrosive paints including acryl, fluorine and epoxy resin series were investigated with electrochemical methods such as corrosion potential, polarization curves, impedance and cyclic voltammogram measurements etc.. There were somewhat good relationships between values measured by electrochemical methods such as corrosion current density obtained by cathodic and anodic polarization curves, value of impedance estimated with AC impedance, and polarization resistance on the cyclic voltammogram, for example, corrosion current density was decreased with increasing of values of impedance and polarization resistance on the cyclic voltammogram. However their relationships between corrosion current density and corrosion potential were not well coincided each other. Consequently it is considered that although a corrosion potential of F101 of fuoric resin series shifted to negative direction than other anti-corrosive paints, its corrosion resistance, indicating on the cathodic and anodic polarization curves, AC impedance curves and cyclic voltammogram, was the most superior to other paints, whereas A100 containing arcylic resin showed a relatively poor corrosion resistance compared to other paints.

Affect of Corrosion Potential and Current Density on Polarization Curves Variations of Polyvinylchloride[II]

  • Park, Chil-Nam;Yang, Hyo-Kyung;Kim, Sun-Kyu
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.3
    • /
    • pp.159-167
    • /
    • 1999
  • This study performed experiments for measuring corrosion potential and current density variations in the polarzation curves of polyvinylchloride. The results were examined to identify particular influences affectingthe corrosion potential such as temperature, pH, enzyme, and salt. The lines representing active anodic dissolution were only slightly shifted in the potential direction by temperature, pH, enzyme and salt. The Tafel slope for the anodic dissolution was determined using the polarization effect with varying conditions. The slope of the polarization curves describing the active-to-passive transition region was noticeably shifted in the potential direction. In addition, using the variation in conditions, the best temperature and pH were determined for the corrosion rate, and resistance of corrosion. The second anodic current density peak and maximum passive current density were designated as degraded(IP/I0). The value of IP/I0 was used in measuring the extent of the degradation of the polyvinychloride. The potentiodynamic parameters of the corrosion were obtained using a Tafel plot.

  • PDF

Redox Reaction on Polarization Curve Variations of Polymer with Enzymes

  • Park, Chil-Nam
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.3
    • /
    • pp.165-171
    • /
    • 2000
  • Experiments were carried out to measure variations in the oxidation potential and current density using the polarization curves of polycarbonate. The results were then examined to identify the influences affecting the oxidation potential related to various conditions, such as temperature, pH, and oxydase(citrate and lipase). The lines representing the active anodic and cathodic dissolution shifted only slightly in the potential direction relative to temperature, pH, and the effect of the enzyme. The Tafel slope for the anodic and cathodic dissolution was determined such that the reversibility polarization was indicated as being effected by various conditions. The slope of the polarization curves describing the active-to-passive transition region shifted noticeably in their direction. Also, by varying the conditions, the optimum conditions for the most ready transform were identified, including temperature, pH, oxidation rate, and resistance of oxidation potential. The critical oxidation sensitivity(I(sub)r/I(sub)f) of the anodic current density peak and maximum passive current density was also determined, which is used in measuring the critical corrosion sensitivity of a polycarbonate.

  • PDF

Influence of the cathode catalyst layer thickness on the behaviour of an air breathing PEM fuel cell

  • Ferreira-Aparicio, Paloma;Chaparro, Antonio M.
    • Advances in Energy Research
    • /
    • v.2 no.2
    • /
    • pp.73-84
    • /
    • 2014
  • Fuel cells of proton exchange membrane type (PEMFC) working with hydrogen in the anode and ambient air in the cathode ('air breathing') have been prepared and characterized. The cells have been studied with variable thickness of the cathode catalyst layer ($L_{CL}$), maintaining constant the platinum and ionomer loads. Polarization curves and electrochemical active area measurements have been carried out. The polarization curves are analyzed in terms of a model for a flooded passive air breathing cathode. The analysis shows that $L_{CL}$ affects to electrochemical kinetics and mass transport processes inside the electrode, as reflected by two parameters of the polarization curves: the Tafel slope and the internal resistance. The observed decrease in Tafel slope with decreasing $L_{CL}$ shows improvements in the oxygen reduction kinetics which we attribute to changes in the catalyst layer structure. A decrease in the internal resistance with $L_{CL}$ is attributed to lower protonic resistance of thinner catalyst layers, although the observed decrease is lower than expected probably because the electronic conduction starts to be hindered by more hydrophilic character and thicker ionomer film.

Full and Partial Polarization Switching Characteristics of Sol-Gel derived Pb(ZrxTi1-x)O3 This Films

  • Kim, Joon-Han;Park, Chang-Yub
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.46-52
    • /
    • 1998
  • In this study, polarization switching characteristics of Pb(ZrxTil-x)O3 (PZT) thin films were investigated. Switching times(ts) were found to be decreased as the Zr mol% was increased. But, the switching peak currents(Imax) showed the largest value at 50 mol% Zr. As a result of this experiment, ts was found to be depended on the remanent polarization and coercive field and also Imax strongly depended on the dielectric constant of PZT thin films. In order to investigate the partial switching kinetics of PZT thin films, short and relatively small voltage pulses were applied to the MFM(metalferroelectric metal) PZT capacitors and polarization switching curves were measured with a variation of the total width of the applied pulses. Also, the switching curves were measured at different applied voltages(4, 8, 10, 12 and 14 volts). As the applied voltages increased, ts and Imax were found to be decreased and increased, respectively. In case of fatigued specimen which we applied $\pm$10 volts square pulse for 1010 cycles, ts and Imax were found to be shorter and smaller than those of virgin specimens. This is due to the decrease of the remanent polarization and the increase of the coercive field.

  • PDF

Influence of Redox Potential Current Density on Polarization Curves with Polypropylene Polymer

  • Park, Chil-Nam;Kim, Myung-Sun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.4
    • /
    • pp.255-261
    • /
    • 2000
  • Experiments were carried out to measure the corrosion potential and current density variations in the polarization curves of polypropylene. In particular, the results were examined to identify those influences affecting the corrosion potential, such as temperature, pH, salt, and oxygen. The Tafel slope for the anodic dissolution was determined based on the polarization effect under various conditions. Furthermore, the optimum conditions for the most rapid transformation were establish based on a variety of conditions, including temperature, pH, corrosion rate, and resistance of corrosion potential. The second anodic current density peak and maximum passive current density were designated as the critical corrosion sensitivity(I(sub)r/I(sub)f). This I(sub)r/I(sub)f value was then used to measure the critical corrosion sensitivity of polypropylene. The potentiodynamic parameters of corrosion were obtained using a Tafel plot.

  • PDF

An Experimental Investigation of the Application of Artificial Neural Network Techniques to Predict the Cyclic Polarization Curves of AL-6XN Alloy with Sensitization

  • Jung, Kwang-Hu;Kim, Seong-Jong
    • Corrosion Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2021
  • Artificial neural network techniques show an excellent ability to predict the data (output) for various complex characteristics (input). It is primarily specialized to solve nonlinear relationship problems. This study is an experimental investigation that applies artificial neural network techniques and an experimental design to predict the cyclic polarization curves of the super-austenitic stainless steel AL-6XN alloy with sensitization. A cyclic polarization test was conducted in a 3.5% NaCl solution based on an experimental design matrix with various factors (degree of sensitization, temperature, pH) and their levels, and a total of 36 cyclic polarization data were acquired. The 36 cyclic polarization patterns were used as training data for the artificial neural network model. As a result, the supervised learning algorithms with back-propagation showed high learning and prediction performances. The model showed an excellent training performance (R2=0.998) and a considerable prediction performance (R2=0.812) for the conditions that were not included in the training data.

Effects of Asymmetric Distribution of Charged Defects on the Hysteresis Curves of Ferroelectric Capacitors

  • Lee Kang-Woon;Kim Yong-Il;Lee Won-Jong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.3 s.36
    • /
    • pp.219-226
    • /
    • 2005
  • When a ferroelectric film has an inhomogeneous distribution of charged defects, a voltage shift in the polarization curve is induced by the internal field generated in the film. The direction and the magnitude of voltage shift in the P-V hysteresis curves obtained by the Sawyer-Tower method are different from those obtained by the virtual ground method. In this study, the asymmetric behavior in the P-V hysteresis curves of inhomogeneous ferroelectric films was investigated with a physical model and the polarization curves obtained by the Sawyer-Tower and the virtual ground methods are compared.

  • PDF

Polarization Behaviors of SnCu Pb-Free Solder Depending on the P, Ni, Addition (SnCu계 무연솔더의 Ni, P 첨가에 따른 분극거동)

  • Hong Won Sik;Kim Whee Sung;Park Sung Hun;Kim Kwang-Bae
    • Korean Journal of Materials Research
    • /
    • v.15 no.8
    • /
    • pp.528-535
    • /
    • 2005
  • It is inclined to increase that use of hazardous substances such as lead(Pb), mercury (Hg), cadmium(Cd) etc. are prohibited in the electronics according to environmental friendly policies of an advanced nation for protecting environment of earth. As this reasons, many researches for ensuring the reliability were proceeding in Pb free soldering process. n the flux remains on the PCB(printed circuit board) in the soldering process or the electronics exposed to corrosive environment, it becomes the reasons of breakdown or malfunction of the electronics caused by corrosion. Therefore in this studies we researched the polarization and Tafel properties of Sn40Pb and SnCu system solders based on the electrochemical theory. The experimental polarization curves were measured in distilled ionized water and 1 mole $3.5 wt\%$ NaCl electrolyte of $40^{\circ}C$, pH 7.5. Ag/AgCl and graphite were utilized by reference and counter electrodes, respectively. To observe the electrochemical reaction, polarization test was conducted from -250mV to +250mV. From the polarization curves composed of anodic and cathodic curves, we obtained Tafel slop, reversible electrode potential(Ecorr) and exchange current density((cow). In these results, we compared the corrosion rate of SnPb and SnCu solders.

Analytical polarization curve of DMFC anode

  • Kulikovsky, A.A.
    • Advances in Energy Research
    • /
    • v.1 no.1
    • /
    • pp.35-52
    • /
    • 2013
  • A model for DMFC anode performance is developed. The model takes into account potential--independent methanol adsorption on the catalyst surface, finite rate of proton transport through the anode catalyst layer (ACL), and a potential loss due to methanol transport in the anode backing layer. An approximate analytical half--cell polarization curve is derived and equations for the anode limiting current density are obtained. The polarization curve is fitted to the curves measured by Nordlund and Lindbergh and parameters resulted from the fitting are discussed.