• Title/Summary/Keyword: Point variation aspect

Search Result 27, Processing Time 0.02 seconds

Convective Heat Transfer to Water near the Critical Region in Horizontal Rectangular Ducts (수평 직사각 덕트 내 임계점 부근 물의 대류열전달 특성)

  • Lee, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.477-485
    • /
    • 2012
  • Fluid flow and heat transfer in horizontal ducts are strongly coupled with large changes in thermodynamic and transport properties near the critical region as well as the gravity force. Numerical analysis has been carried out to investigate convective heat transfer in horizontal rectangular ducts for water near the thermodynamic critical point. Convective heat transfer characteristics, including velocity, temperature, and the properties as well as local heat transfer coefficients along the ducts are compared with the effect of proximity on the critical point. When there is flow acceleration because of a density decrease, convective heat transfer characteristics in the ducts show transition behavior between liquid-like and gas-like phases. There is a large variation in the local heat transfer coefficient distributions at the top, side, and bottom surfaces, and close to the pseudocritical temperature, a peak in the heat transfer coefficient distribution resulting from improved turbulent transport is observed. The Nusselt number distribution depends on pressure and duct aspect ratio, while the Nusselt number peak rapidly increases as the pressure approaches the critical pressure. The predicted Nusselt number is also compared with other heat transfer correlations.

Clinical Applications of the Meridian Theory in the Point of Hyungsang Medicine (형상의학적(形象醫學的) 관점(觀点)에서 본 경락이론(經絡理論)의 임상활용(臨床活用))

  • Kang, Kyung-Hwa;Song, Choon-Ho;Kim, Hyung-Gyu;Lee, Yong-Tae
    • Korean Journal of Acupuncture
    • /
    • v.21 no.1
    • /
    • pp.149-173
    • /
    • 2004
  • Objective & Methods : In the point of several medical books included 'Internal Classic' and Hyungsang medicine, the writer studied about meridian theory and it's disorders, after adapting to acupuncture and herb medicine. Results : 1. Dr. Jisan explained concretely physiological and pathological meridian appearances with using metaphor about phenomenons of nature and human living. 2. Shapes corresponding to meridian are considered as Yukkyunghyung formed by more or less of vigor and blood, and by tendency of up and down in eyes and nose, and also contained diseases of viscera and characters. 3. The colors connected with meridian are changed according to conditions, and meridian is seen through colors. And then colors is the properties of vital energy and symbol of spirit, that is expressed as aspect of essence, vigor, spirit and blood, as the original color of five viscera, as the colors of four seasons and as the colors of diseases. So the changes of feelings are appeared to meridian flow. 4. The method of examining pulse for meridian disorders is applied to Jisan diagram. Jisan diagram is devised from mutual communication of viscera and connection with inside and outside. It is conjugated widely in clinical examination to be distinguished into Dam-Bangkwang, into diseased part of viscera and into meridian. Also it is conjugated recuperation of diseases. 5. The meridian diseases are appeared all the distributed parts of meridian, especially skin, hair, eyebrow, and the ends of the extremities which are sensitive to stimulus. The causes are the disharmony between vital energy and blood and the discordance of six atmospheric variation. The symptoms are skinny aches, itching and eruption, etc. Conclusions : The acupuncture of Hyungsang medicine which utilizes classification of shapes, examining pulse according to Jisan diagram and demonstration of symptoms, is very effective and required systematical study from now on.

  • PDF

A study on composition and narrative style of 『Jwagyebudam』 (『좌계부담(左溪裒談)』의 구성과 서술방식)

  • Cho, Jeongyun
    • (The)Study of the Eastern Classic
    • /
    • no.63
    • /
    • pp.83-113
    • /
    • 2016
  • This paper is focused on objective and meaning of its compilation through reviewing system, composition, method of description, and content of "Jwagyebudam". "Jwagyebudam" has all round form of a history and character book by recording via arranging figures from the end of 16th century to the middle of 18th century in a chronological order. Figure were not only assigned at close range by steretyping people into groups to a degree in it, but also recorded in a chronological order. In view of method of description, "Jwagyebudam" concentrated a theme by recording via separating different people associated from a figure and content of the same event by using the same method like 'Hogeonbeom(互見法)' shown in "Sagiyeoljeon(史記列傳)". In addition, it obtained effect to objectify evaluation of figures included. In a method of embodying figures, it has described concretely and in a three dimensions figures by recording anecdotes and poems associated with them via focusing on lifelong characteristic aspect of corresponding figures. In other words, "Jwagyebudam" can be called by biographies or character books, writings specialized in characters center among writings of method to weave freely experience. In a broad sense, it can be called a writing to cover a function of history book, poem and picture. This was located to a starting point of variation of inclusive and descriptive method. Namely, several kinds of writings in late Joseon dynasty can show aspect to fulfill specialized aspect gradually.

The Effect on Heat Loss Reduction in a refrigeration with the Variation of Gasket Shape (냉장고 가스켓 형상 변화에 따른 냉장고 열손실 저감 효과)

  • Ha, Ji-Soo;Jung, Kwang-Soo;Kim, Tae-Kwon;Kim, Kyung-Ho;Jeong, Gwan-Sik;Kim, Seok-Ro
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.286-291
    • /
    • 2008
  • Insulation of refrigerator with gasket material near door becomes the technical point at the aspect of heat loss and energy efficiency. Heat loss of refrigerator through the gasket is nearly 30%. In this paper, quantitative evaluation method of heat loss through gasket in established suggest the method for the improvement of heat loss. To analyze the heat transfer, we have used the common software Fluent that is used to CFD. Because of using the convection coefficient of heat transfer, we have solved only the equation of energy for heat transfer. As a result, we have known that heat loss flows through the heat flux vector and that the heat gathered out of the outside iron plate is transferred inner part through the gasket and ABS, etc. Through the result of the numerical simulation that use sub-gasket, we have known that we are able to reduce the heat loss about $20{\sim}40%$. when we applied that sub-gasket on a real refrigerator, the power consumption had reduced about 4.76%. In addition, when we applied a more improved sub-gasket on a real refrigerator and measured the power of the refrigerator the power consumption does reduce about 3% and we will try to apply the improved sub-gasket on a new models of refrigerator.

  • PDF

Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target (표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가)

  • Choi, Young Se;Park, Hyo Kuk;Kim, Se Young;Kim, Joo Ho;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose: To evaluate the usefulness of the $HexaPOD^{TM}$ evo RT system(6DoF couch) and the tendency of dose difference according to size of rotational direction error for volumetric rotational modulated radiotherapy(V-MAT) in patients with long target lengths. Therefore, it is suggested to recommend the need for rotational error correction. Materials and Methods: Ten patients with Esophagus cancer or Breast cancer including SCL treated with HexaPOD 6DoF(Six-Degree of Freedom) couch were included in this study. 6DoF couch was used to measure the difference in dose according to the rotation error in the directions of Rx(pitch), Ry(roll), and Rz(yaw). Each rotation error was applied. Positioning variation on x, y and z axis was verified and random variations were made by 6DoF couch with positioning variation. Modified DQA is conducted and point dose and gamma value are analyzed and compared. In addition, after applying the rotation error every $1^{\circ}$ to treatment plans of each target with a diameter of 3 cm, 5, 10, 15, and 20 cm respectively, gamma passing rate is being monitored by its aspect of change according to types and sizes of the target length and rotation error. Results: Mean error of the point dose and Gamma passing rate when the position variation was applied were $2.50{\pm}1.11%$ and $84.1{\pm}7.39%$ in the Rx direction, $2.36{\pm}1.16%$, and $81.0{\pm}8.49%$ in the Ry, $2.35{\pm}1.10%$ and $84.4{\pm}6.99%$ in the Rz direction, respectively. As a result of analysis on gamma passing rate according to types and sizes of the target length and rotation error, the gamma passing rate tended to decrease with increasing rotation error in the Rx and Rz directions except Ry direction. In particular, the lowest gamma passing rate (74.2 %) was in the case of $2.5^{\circ}$ rotation error in Rz direction of the target of 10 cm. Conclusion: The correction of the rotational error is needed for volumetric modulated radiotherapy of the treatment area with a long target length, and the use of 6DoF couch will improve the reproducibility of the patient position and the quality of the treatment.

  • PDF

Behavior of Columns Due to Variation of Performance Influencing Factors Based on Performance Based Design (성능기반설계에 기초한 성능영향인자 변화에 따른 기둥의 거동분석)

  • Yun, Sung-Hwan;Choi, Min-Choul;Kang, Yoon-Sig;Park, Tae-Hyo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.489-498
    • /
    • 2010
  • The performance evaluation of reinforcement concrete structure is carried out as a function of the following performance influencing factors: (1) the strength of concrete, (2) longitudinal reinforcement, (3) transverse reinforcement, (4) aspect ratio, and (5) axial force. With various values of the five parameters, eigenvalue analysis and non-linear static analysis were performed to investigate the structural yield displacement, yield basis shear force, and static performance of ductility ratio. In addition, the performance evaluation is carried out according to the modified capacity spectrum method (FEMA-440) using the results of non-linear static analysis, and the effect of each parameter on performance point is analyzed. Based on the result of eigenvalue analysis and non-linear static analysis indicates, that the natural period and the ductility ratio are affected more by the structural properties than the material properties. In case of the analysis of the criterion of performance points, the effect of section shape is one of the important factors together with natural period and ductility ratio.

Scapular Free Flap (유리 견갑 피판 이식술)

  • Chung, Duke-Whan;Han, Chung-Soo;Yim, Chang-Moo
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.24-34
    • /
    • 1996
  • There are many kinds of free flaps for management of extensive soft tissue defect of extremities in orthopaedic field. Free vascularized scapular flap is one of the most useful and relatively easy to application. This flap has been utilize clinically from early eighties by many microsurgical pioneers. Authors performed 102 cases of this flap from 1984 to 1995. We have to consider about the surgical anatomy of the flap, technique of the donor harvesting procedures, vascular varieties and anatomical abnormalities and success rate and the weak points of the procedure. This flap nourished by cutaneous branches from circumflex scapular vessels emerges from the lateral aspect of the subscapular artery 2.5-5cm from its lateral origin passing through the triangular space(bounded by subscapularis, teres minor, teres major, long head of triceps). The terminal cutaneous branch runs posteriorly around the lateral border of the scapular and divided into two major branches, those transeverse horizontally and obliquely to the fascial plane of overlying skin of the scapular body. We can utilize these arteries for scapular and parascapular flap. The vascular pedicle ranged from 5 to 10 cm long depends on the dissection, usually two venae comitantes accompanied circumflex scapular artery and its major branches. The diameter of the circumflex scapular artery is more than 1mm in adult, rare vascular variation. Surgical techniques : The scapular flap can be dissected conveniently with prone or lateral decubitus position, prone position is more easier in my experience. There are two kinds of surgical approaches, most of the surgeon prefer elevation of the flap from its outer border towards its base which known easier and quicker, but I prefer elevation of the flap from its outer border because of the lowering the possibilities of damage to vasculature in the flap itself which runs just underneath the subcutaneous tissue of the flap and provide more quicker elevation of the flap with blunt finger dissection after secure pedicle dissection and confirmed the course from the base of the pedicle. There are minimal donor site morbidity with direct skin closure if the flap size is not so larger than 10cm width. This flap has versatility in the design of the flap shape and size, if we need more longer and larger one, we can use parascapular flap or both. Even more, the flap can be used with latissimus dorsi musculocutaneous flap and serratus anterior flap which have common vascular pedicle from subscapular artery, some instance can combined with osteocutaneous flap if we include the lateral border of the scapular bone or parts of the ribs with serratus anterior. The most important shortcoming of the scapular free flap is non sensating, there are no reasonable sensory nerves to the flap to anastomose with recipient site nerve. Results : Among our 102 cases, overall success rate was 89%, most of the causes of the failure was recipient site vascular problems such as damaged recipient arterial conditions, and there were two cases of vascular anomalies in our series. Patients ages from 3 years old to 62 years old. Six cases of combined flap with latissimus dorsi, 4 cases of osteocutaneous flap for bone reconstruction, 62 parascapular flap was performed - we prefer parascapular flap to scapular. Statistical analysis of the size of the flap has less meaningful because of the flap has great versatility in size. In the length of the pedicle depends on the recipient site condition, we can adjust the pedicle length. The longest vascular pedicle was 14 cm in length from the axillary artery to the enter point cutaneous tissue. In conclusion, scapular free flap is one of the most useful modalities to manage the large intractable soft tissue defect. It has almost constant vascular pedicle with rare anatomical variation, easy to dissect great versatility in size and shape, low donor morbidity, thin and hairless skin.

  • PDF