An experimental study on the resistance and movement of short pile installed in sands under horizontal pullout load

  • Kwon, Oh Kyun;Kim, Jin-Bok;Kweon, Hyuck-Min
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.1
    • /
    • pp.87-97
    • /
    • 2014
  • In this study, the model tests were conducted on the short piles installed in sands under a horizontal pullout load to investigate their behavior characteristics. From the horizontal loading tests where dimensions of the pile diameter and length, and loading point were varied, the horizontal pullout resistance and the rotational and translational movement pattern of the pile were investigated. As a result, the horizontal pullout resistance of the pile embedded in sands was dependent on the pile length, diameter, loading point, etc. The ultimate horizontal pullout load tended to increase as the loading point (h/L) moved to the bottom from the top of the pile, regardless of the ratio between the pile length and diameter (L/D), reached the maximum value at the point of h/L = 0.75, and decreased afterwards. When the horizontal pullout load acted on the upper part above the middle of the pile, the pile rotated clockwise and moved to the pullout direction, and the pivot point of the pile was located at 150-360mm depth below the ground surface. On the other hand, when the horizontal pullout load acted on the lower part of the pile, the pile rotated counterclockwise and travelled horizontally, and the rotational angle was very small.

The design and the full load test results of 765kV tower foundation (765kV 철탑기초 설계 및 기초재하시험)

  • Kim, J.B.;Cho, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.447-449
    • /
    • 1995
  • In terms of a new development on the foundation design of 765kV tower and its applications, a revolutionary turning point comes out through this study in approaching the new concept, what we call "Rock anchor" "Deep foundation" to tower foundation which was officially approved by the full load test. this contents is described of the foundation design and the results of full load test for two types foundation.

  • PDF

Bearing Capacity and Control Method of Driven Piles (기성말뚝의 지지력 거동해석과 시공관리방안)

  • 박영호;김경석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.249-258
    • /
    • 1999
  • Dynamic load and static load tests are performed on steel pipe piles and concrete piles at five construction sites in highway to compare the difference of load bearing mechanisms. At each site, one steel pile is instrumented with electric strain gages and dynamic tests are performed on the pile during installation. Damages of strain gages due to the installation are checked and static test is performed upon the same pile after two or seven days as well. It shows that load transfer from side friction to base resistance behaves somewhat differently according to the results of load-settlement analysis obtained from PDA and static load test. Initial elastic stage of load settlement curves of two load tests is almost similar. But after the yielding point, dynamic resistance of pile behaves more stiffer than static resistance, thus, dynamic load test result might overestimate the real pile capacity compared with static result. Analysis of gage readings shows that unit skin friction increases exponentially with depth. The skin friction is mobilized at the 1∼2m above the pile tip and contributes to the considerable side resistance. Comparison of side and base resistances between the measured value and the calculated value by Meyerhof's bearing capacity equation using SPT N value shows that the calculated base resistance is higher than the measured. Therefore, contribution of side resistance to total capacity shouldn't be ignored or underestimated. Finally, based upon the overall test results, a construction control procedure is suggested.

  • PDF

An Experimental Study for the Qualitative Effect of Carrier Pin Hole Position Error on Planet Load Sharing of Wind Turbine Three-point Suspension Gearbox (풍력발전기용 3점 지지 기어박스에서 캐리어 핀홀 위치 오차가 유성기어의 하중분할에 미치는 정성적 영향에 관한 실험적 연구)

  • Nam, Ju-Seok;Han, Jeong-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.2
    • /
    • pp.97-104
    • /
    • 2016
  • In this study, the qualitative effects of the positional error of carrier pin holes on the planet load sharing characteristics of the three-point suspension gearbox of wind turbines were investigated experimentally. A 35-kW gearbox comprising two planetary gear stages and a parallel gear stage and size one-fourth of that of a 2-MW three-point suspension gearbox was used as the test gearbox. The strain gauges attached to the ring gear teeth of the input planetary gear stage were used for the purpose of this study. The applied loading conditions were 50%, 75%, and 100% of the rated torque, and the mesh load factor was used as the load sharing index. The experimental results indicated that both the magnitude and direction of the positional error of pin holes had a significant effect on the planet load sharing characteristics of the three-point suspension gearbox. In addition, an increase in the applied torque results in uniform load sharing.

Study on a loading mechanism for fixed ratio traction drives (고정 감속비트랙션 드라이브의 압부력 발생장치에 대한 연구)

  • Kim, Sung-Yeol;Kim, Bae-Jin;Park, Dae-Hyun;Oh, Se-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1212-1218
    • /
    • 2003
  • A novel loading mechanism of wedge roller type has been developed. This type traction drive has long system life and high efficiency by changing the pre-load on a contact point. And this loading mechanism does not need precision machining. So it has, as opposed to the conventional loading mechanism, an advantage in saving manufacturing cost. In this paper, by analyzing pre-load generating mechanism, spring pre-load and the roller size are defined and the stress on the contact point by pre-load is calculated. On the basis of this analysis, the model of wedge roller type traction drive for the test is made and was carried out its performance test. It can transmit input torque up to 1.5 N m, with high efficiency over 91% up to 98%, with slip rate under 2.5%.

  • PDF

The Weathering Index and Prediction of Uniaxial Compressive Strength for Chung-Ju Granite (충주 지역 화강암의 풍화지수 및 일축압축강도 추정에 관한 연구)

  • Eom, Tae-Uk;Kim, Hak-Mun;Kim, Chan-Kuk;Jang, Kyung-Jun;Pyo, Myung-Ryul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.863-874
    • /
    • 2008
  • We have to judge engineering properties of rock accurately in order to design and construct rock structure safely and economically. Among the rock tests, the test result of UCS(Uniaxial Compressive Strength) is very important factor used in the variety ways for designing and construction of underground structures, rock slope and foundation analysis. But the UCS test has some disadvantages of intact sample preparation such as because the shape of sample has to be regular cylindrical, cube or rectangular. In order to solve those problem, indirect tests are used such as point load test, schmidt hammer test, absorption test, dry density to predict UCS of rock. Those tests are easy to prepare sample and convenient to carry out the tests, so it is simple and costs less. Schmidt hammer test are frequently used in the construction site, because it is handy and easy to use, but there is concern of misuse without classifying the specification of each schmidt hammer. Thus, this study suggested presumptive numerical formula related on each specification of schmidt hammer test, point load test, absorption test and dry density also. We compared presumptive numerical formula and R-square through schmidt rebound assessment method already brought up. Also, through the test we offer the extent of weathering index according to the weathering grade.

  • PDF

The method using dynamic load and static load figures out gust factor of the membrane structure (동적하중과 정적하중을 이용한 막구조의 거스트 계수 산출 방법)

  • Wang, Ben-Gang;Jeong, Jae-Yong;You, Ki-Pyo;Kim, Young-Moon
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.19-24
    • /
    • 2008
  • The thesis is for gust factor needing when calculate the wind resistance design. For the gust factor, to the membrane structural model, carry through the wind tunnel test and the static load test. Therefore, at first through the tensile test of the fabric material, designate the material of the membrane structural model. Then, to saddle, wave, arch and point four kinds of basic shape membrane structural models, carry on the wind tunnel test, determine their dynamic load and distortion on lateral direction. Finally, according to distort situation of the membrane structure in the wind tunnel test, carry on the static load experiment outside of the wind tunnel, calculate static load which corresponding with distort. According to dynamic load and the static load, figure out gust factor of these kinds of basic membrane structure.

  • PDF

Fatigue Safety Evaluation of the Half-Depth Precast Deck with RC Rib Panel (리브 형상을 갖는 반단면 프리캐스트 바닥판의 피로 안전성 평가)

  • Hwang, Hoon Hee
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.103-110
    • /
    • 2019
  • In order to reduce the accidents occurring at construction sites, it is necessary to approach with harmonious measures considering various aspects such as systems, training, facilities, and protection equipments. Suggestion of safe construction method can be a good alternative. In the previous study, the half-depth precast deck with RC rib panel was proposed as an alternative method for safe bridge deck construction, and the performance required by the design code was verified through a four-point bending test. But the actual bridge deck is subjected to the repetitive action of the wheel load rather than the bending condition due to the four-point load. In this study, fatigue test was performed by repeating the wheel load $2{\times}10^6$ cycles to verify the safety of the half-depth precast deck with RC rib panel under actual conditions. As a result, fatigue effect due to repetition of wheel load was not significant in terms of serviceability such as crack width and deflection. In the residual strength test conducted after the fatigue test, the half-depth precast deck with RC rib panel failed by punching shear which is typical failure mode of bridge decks and the residual strength was similar to the punching strength of the RC and PSC bridge decks in spite of the fatigue effects.

An Experimental Study on the Structural Characteristics of Reinforced Concrete Beams Containing Oyster Shells (굴패각을 사용한 철근콘크리트 보의 특성에 관한 실험적 연구)

  • Lee, Sang-cheol;Woo, Song-gyu;An, Yong-deok;Jun, Hak-su;Koo, Hae-shik
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.135-142
    • /
    • 2007
  • This is an experimental study on the structural characteristics of reinforced concrete beams using of the oyster shells as a substitute fine aggregate of concrete. In this study, the main factors consist of the grain sizes and the percentage of substitution of oyster shells to fine aggregate in the equal water cement ratio. The results of the study showed as followed. The initial load value of them represented similar constant within 10% of the maximum load value in each test beam. But the maximum load value and the ultimate load value decreased with increased grain size and the rate of substitution. As the grain size of oyster shells became smaller, the load values of them were somewhat higher. The deflection among deformation properties of reinforced concrete beams with oyster shells represented typical curves like that of normal reinforced concrete. In the deformation of steel and concrete, the deformation was proportionated to the load till yield point and from yield point until approaching the ultimate load point. One type was typical curve of the load and the deformation and the other type irregularly was changed to very small deformation for the load increase centering around load axis. After the analyzing structural behaviors and the properties of reinforced concrete test beams with oyster shells, the most excellent grain size of oyster shells represented 1.0mm and less or 5.0mm and less with taking uniformly, and the percentage of practicable substitution of them to fine aggregate was about 30%.

Estimation of Rotation Point of Laterally Loaded Piles through Laboratory Test (실내모형 실험을 통한 수평재하말뚝의 회전점 산정)

  • Hwang, Sung-Wook;Hong, Jung-Moo;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.744-747
    • /
    • 2008
  • In this study, to analyze the rotation point of piles, the laboratory lateral load test was performed. The lateral load bearing capacity is one of the important factor related with structure failure directly. Analyzing rotation point in different soil condition, relative density and stress condition, leads more accurate ultimate lateral bearing capacity. Also, reliability was analyzed about established 예측식 as applying to tapered pile. As a result, the established prediction was suitable to cylider pile, but not to tapered pile.

  • PDF