• Title/Summary/Keyword: Point attenuation rate

Search Result 22, Processing Time 0.033 seconds

A Study on Groundwater Quality and Biodegradability at the Petroleum Contaminated Sites of Kangwon and Gyeonggi Provinces, Korea (강원도 및 경기도 소재 유류오염지역의 수질특성, 발현 생분해능과 오염물질 저감속도)

  • Choi, Hyun-Mi;Lee, Jin-Yong;Park, Yu-Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.2
    • /
    • pp.24-33
    • /
    • 2010
  • This study focused on the groundwater quality, biodegradability and attenuation rate at the petroleum contaminated sites of Kangwon and Gyeonggi Provinces, Korea. For groundwater quality, Kangwon site showed chemical compositions of $Ca-SO_4+Cl$, $Ca-HCO_3$ and $Na+K-HCO_3$ types, while Gyeonggi site showed chemical compositions of $Ca-SO_4$, $Ca-HCO_3$ and $Na-HCO_3$ types. $Na+K-HCO_3$ and $Na-HCO_3$ types were detected only in February. Among many biodegradation processes, the majority was attributed to biodegradation from denitrification in both area. In Kangwon site, biodegradation from denitrification occupied 63.5%, and in Gyeonggi site it was 39.45%. Biodegradation from the most efficient aerobic respiration occupied 7.12% in Kangwon site, while Gyeonggi site in it did 27.29%. Point attenuation rate of BTEX in Gyeonggi site (GW-22) was 0.0182 $day^{-1}$, half life of BTEX was 84 days, and thus 124 days (0.34 year) would be required to clean up this site. Mean of point attenuation rate of TPH in Kangwon site was 0.0088 $day^{-1}$, mean of half life was 257 days, and thus 462 days would be required to clean up the site. Mean of point attenuation rate of TPH in Gyeonggi site was 0.0387 $day^{-1}$, mean of half life was 55 days, and thus remediation time was calculated as 99 days.

An Empircal Model of Effective Path Length for Rain Attenuation Prediction (강우감쇠 유효경로 길이 예측을 위한 경험 모델)

  • 이주환;최용석;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.813-821
    • /
    • 2000
  • The engineering of satellite communication systems at frequencies above 10GHz requires a method for estimating rain-caused outage probabilities on the earth-satellite path. A procedure for predicting a rain attenuation distribution from a point rainfall rate distribution is, therefore, needed. In order to predict rain attenuation on the satellite link, several prediction models such as ITU-R, Global, SAM, DAH model, have been developed and used at a particular propagation condition, they may not be appropriate to a propagation condition in Korean territory. In this paper, a new rain attenuation prediction method appropriate to a propagation condition in Korea is introduced. Based on the results from ETRI measurements, a new method has been derived for an empirical approach with an identification on the horizontal correction factor as in current ITU-R method, and the vertical correction factor has been suggested with decreasing power law as a function of rainfall rate. This proposed model uses the entire rainfall rate distribution as input to the model, while the ITU-R and DAH model approaches only use a single 0.01% annual rainfall rate and assume that the attenuation at other probability levels can be determined from that single point distribution. This new model was compared with several world-wide prediction models. Based on the analysis, we can easily know the importance of the model choice to predict rain attenuation for a particular location in the radio communication system design.

  • PDF

A Correction Method of Dose to Attenuation Rate of Transmitting Photon Beam Through Couch Top for Radiosurgery Using Novalis (노발리스를 이용한 방사선 수술시 치료테이블을 투과하는 광자선의 감쇠율에 따른 선량 보정방법)

  • Kim, Sung-Joon;Shin, Hyun-Soo;Ko, Seung-Young;Park, Hye-Li;Kim, Ja-Young;Lee, Bo-Mi;Yea, Ji-Woon;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.12-17
    • /
    • 2011
  • This study has its own goal to deliver the accurate dose on the target volume by calculating and modifying the attenuation rate of photon beam transmitting the couch top with geometric model. The experiment was that the transmission rate and attenuation rate of photon beam transmitting the couch top was predicted by the geometric model, then compared and analyzed with what was measured experimentally based on that. The result showed that the predicted value by the geometric model accorded closely with the experimental value. In addition, in order to judge whether the practical clinical application is available, the point dose, measured after modifying the attenuation rate modelinged according to the treatment plan of a patient of spine radiosurgery, was compared with the one done nothing. The result was that the former showed decreased error range with treatment planned one than the latter. This papers calculated the transmission and attenuation rate with the geometric model transmitting the couch top and verified it experimentally. This method is expected to be very useful in not only the radiosurgery using Novalis but also the general radiation therapy.

Conversion of Rain Rate Cumulative Distributions by Multiple Regression Model (다중회기모형에 의한 강우강도 누적분포의 변환)

  • Dung, Luong Ngoc Thuy;Sohn, Won
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.4
    • /
    • pp.13-15
    • /
    • 2014
  • At frequencies above 10 GHz, rain is a dominant propagation phenomenon on satellite link attenuation. The prediction of rain attenuation is based on the point rainfall rate for 0.01 % of an average year with one minute integration time. Most of available rain data have been measured with 60 minutes integration time, and many researchers have been studying on converting the rainfall rate data from various integration times to one minute integration time. This paper proposes a new Multiple Regression model for the conversion, and the proposed schemes show better performance than the existing schemes.

Dosimetrical Analysis of Reactor Leakage Gamma-rays by Means of Scintillation Spectrometry

  • Jun, Jae-Shik
    • Nuclear Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.291-309
    • /
    • 1973
  • Exposure rates due to leakage gamma-rays from operating reactors TRIGA Mark II and III were measured in a horizontal plane by means of scintillation spectrometry using a 3"$\times$3" cylindrical Nal(T1) detector associated with a 400 channel pulse height analyzer under varied conditions of reactor operation. In determining exposure rate due to the leakage gamma-rays at each point of measurement, Moriuchi's spectrum-exposure rate conversion theory was applied instead of using conventional responce matrix method which necessitates very complicated procedures to convert a spectrum into exposure rate. The results show that a basic pattern of "typical" spectrum of the reactor leakage gamma-rays is neither affected by thermal output of the reactor, nor influenced by overall attenuation in radiation intensity. It was indicated that he attenuation of the leakage gamma-rays in air in terms of exposure rate as a whole follows an exponential law, and the total exposure rate due to the leakage gamma-rays at a certain point is nearly proportional to thermal output of the reactor. The complexity in spectrum measured for a movable core reactor, TRIGA Mark III, was analyzed through spectrum resolution, and proper judgement of the leakage gamma-rays in a complex spectrum was discussed.ctrum was discussed.

  • PDF

Quantitative Measurement of Soot concentration by Two-Wavelength Correction of Laser-Induced Incandescence Signals (2파장 보정 Laser-Induced Incandescence 법을 이용한 매연 농도 측정)

  • 정종수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.54-65
    • /
    • 1997
  • To quantify the LII signals from soot particle of flames in diesel engine cylinder, a new method has been proposed for correcting LII signal attenuated by soot particles between the measuring point and the detector. It has been verified by an experiment on a laminar jet ethylene-air diffusion flame. Being proportional to the attenuation, the ratio of LII signal at two different detection wavelengths can be used to correct the measured LIIsignal and obtain the unattenuated LII signal, from which the soot volume fraction in the flame can be estimated. Both the 1064-nm and frequency-doubled 532-nm beams from the Nd : YAG laser are used. Single-shot, one-dimensional(1-D) line images are recorded on the intensified CCD camera, with the rectangular-profile laser beam using 1-mm-diameter pinhole. Two broadband optical interference filters having the center wavelengths of 647 nm and 400 nm respectively and a bandwidth of 10 nm are used. This two-wavelength correction has been applied to the ethylene-air coannular laminar diffusion flame, previously studied on soot formation by the laser extinction method in this laboratory. The results by the LII measurement technique and the conventional laser extinction method at the height of 40 nm above the jet exit agreed well with each other except around outside of the peaks of soot concentration, where the soot concentration was relatively high and resulting attenuation of the LII signal was large. The radial profile shape of soot concentration was not changed a lot, but the absolute value of the soot volume fraction around outside edge changed from 4ppm to 6.5 ppm at r=2.8mm after correction. This means that the attenuation of LII signal was approximately 40% at this point, which is higher than the average attenuation rate of this flame, 10~15%.

  • PDF

An Auto-tuning Algorithm of PI Controller Using Time Delay Element (시간 지연 요소를 이용한 PI 제어기 자동 동조 알고리즘)

  • Oh, Seung-Rohk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.6
    • /
    • pp.1-5
    • /
    • 2010
  • We propose an algorithm which can classify the system should use a PI controller, which have a weak high frequency attenuation characteristics near the critical frequency. To classify the system, we use a time delay element to calculate a gain attenuation rate near the critical frequency. The proposed algorithm also can design PI controller with the given magnitude margin and phase margin specification. The proposed algorithm uses time delay element and saturation function to identify the one point information in frequency domain. We justify the proposed algorithm via the simulation.

Noise Generation by Water-Sodium Reaction and its Absorption on Hydrogen Bubbles for KALIMER Steam Generator (칼리머 증기발생기에서 물-소듐 반응에 의한 소음 발생과 수소 기포의 소음 흡수)

  • Kim, Tae-Joon;Yughay, Valeri S.;Hwang, Sung-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1829-1835
    • /
    • 2000
  • The experimental results of sodium-water reaction noise measurement in frequency range $1{/sim}200kHz$ are presented. The experiments of noise generation under the condition of sodium test facility, water leak rate $0.01{\sim}1.2g/s$ and temperature of sodium $250{\sim}500^{\circ}C$, were carried out. From theoretical study it is noted that the noise resonant attenuation on hydrogen bubbles in liquid sodium plays the significant role for leak noise spectra formation. Interaction of leak noise and hydrogen bubbles in sodium being accompanied by thermal, emission and viscosity energy dissipation was studied. Acoustic noise spectra were investigated from point of view of water leak detection in sodium/water steam generator. The results of sodium-water reaction noise absorption on hydrogen bubbles in liquid sodium by temperature $250{\sim}500^{\circ}C$ are presented. The theoretical model of noise absorption using the coefficients of attenuation was developed. From calculation the coefficients of attenuation were estimated.

  • PDF

Automatic Contrast Enhancement by Transfer Function Modification

  • Bae, Tae Wuk;Ahn, Sang Ho;Altunbasak, Yucel
    • ETRI Journal
    • /
    • v.39 no.1
    • /
    • pp.76-86
    • /
    • 2017
  • In this study, we propose an automatic contrast enhancement method based on transfer function modification (TFM) by histogram equalization. Previous histogram-based global contrast enhancement techniques employ histogram modification, whereas we propose a direct TFM technique that considers the mean brightness of an image during contrast enhancement. The mean point shifting method using a transfer function is proposed to preserve the mean brightness of an image. In addition, the linearization of transfer function technique, which has a histogram flattening effect, is designed to reduce visual artifacts. An attenuation factor is automatically determined using the maximum value of the probability density function in an image to control its rate of contrast. A new quantitative measurement method called sparsity of a histogram is proposed to obtain a better objective comparison relative to previous global contrast enhancement methods. According to our experimental results, we demonstrated the performance of our proposed method based on generalized measures and the newly proposed measurement.

Tractor Implement Attitude Control System Using Microcomputer (마이크로컴퓨터를 이용(利用)한 트랙터 작업기(作業機)의 자세제어(姿勢制御) 시스템에 관한 연구(硏究))

  • Yoo, S.N.;Suh, S.R.;Kim, D.J.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.3
    • /
    • pp.199-208
    • /
    • 1993
  • This study was attempted to develop the eletronic-hydraulic hitch system for controlling the attitude of tractor implements and to investigate control performance of the system through experiments. Main components of the system developed in this study were reference inputs panel, inclination angle detecter, electronic controller consisted of IBM-AT PC and interfaces, electro-hydraulic directional valves and other hydraulic components and three-point hitch linkage. Experiments were carried out to investigate the response of the system to the step and sine inputs. The effects of hydraulic flow rate and dead band on control performance were analized. Attitude of the implement was controlled within 2.4-5.1 degrees to the setting attitude when the hydraulic flow rate was in the range of $0.25-1.5{\ell}/min$. And implement was controlled without rapid amplitude attenuation and phase angle change in the frequency range of 0.02-0.2Hz when the hydraulic flow rate was in the range of $0.25-1.5{\ell}/min$. Control performance of the system can be expected to be improved if the inclination angle detecter show rapid and stable output as the implement moves.

  • PDF