• 제목/요약/키워드: Pohang Light Source (PLS)

검색결과 47건 처리시간 0.026초

Digital DC power supply for light accelerator

  • Kim, Yoon-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권8호
    • /
    • pp.1000-1003
    • /
    • 2014
  • There are 70 vertical and 70 horizontal correctors for Pohang Light Source. Until mid of 2000, power supplies for these correctors were based on 1990's technology, so the global orbit feedback system was not possible with poor 12 bit resolution. A new task force team was assembled to develop new power supplies with BESSY type DAC cards. After the project, two vertical correctors in each lattice were connected with new power supplies, and the global orbit feedback was available within the accuracy of 5 microns. However, this replacement was not enough to satisfy the beam stability requirement of 2 microns for PLS. We have launched another power supply design based on all digital technology. This attempt was completed within a year, and 80 units were assembled in house. Currently, the global orbit feedback system is running successfully with new digital power supplies and the compensation of chamber motion due to the thermal load by using digital displacement transducers attached on each BPMs.

Real-time X-ray Scattering as a Nanostructure Probe for Organic Photovoltaic Thin Films

  • 이현휘;김효정;김장주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.181-181
    • /
    • 2013
  • Recently, nanostructure and the molecular orientation of organic thin films have been largely paid attention due to its importance in organic electronics such as organic thin film transistors (OTFTs), organic light emitting diodes (OLEDs), and organic photovoltaics (OPVs). Among various methods, the diffraction and scattering techniques based on synchrotron x-rays have shown powerful results in organic thin film systems. In this work, we introduce the in-situ annealing system installed at PLS-II (Pohang Light Source II) for organic thin films by simultaneously conducting various x-ray scattering measurements of x-ray reflectivity, conventional x-ray scattering, grazing incidence wide angle x-ray scattering (GI-WAXS) and so on. Using the in-situ measurement, we could obtain real time variation of nanostructure as well as molecular orientation during thermal annealing in metal-phthalocyanine thin films. The variation of surface and interface also could be simultaneously investigated by the x-ray reflectivity measurement.

  • PDF

XFEL를 위한 기존의 펄스전원공급장치 개선 연구 (Study of Pulse Generator used Inverter HV Power Supply)

  • 박성수;김상희;김성철;황정연;한영진;최진혁;김홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2146-2148
    • /
    • 2005
  • The 2.5GeV linac of the Pohang Light Source(PLS) is planed to be converted to a XFEL. The PAL XFEL requires a new 1.2-GeV linac that will be combined to the existing linac to increase a beam energy upto 3.7GeV. This stability is mainly determined by a low level RF drive system and klystron-modulators. The stability level of the modulator has to be improved 10 times better to meet the pulse stability of 0.02 %. The regulation methods such as traditional de-Qing and precision inverter charging technology are reviewed to find out suitable upgrade scheme of the modulators. In order to obtain electron beam of the consequently stability for XFEL linac, the pulse-to-pulse beam voltage regulation is less than +/-0.5%. To get the reliable stability of the modulator which is less than +/-0.2%, a charging section is improved in a modulator which has been operated with inverter power supply and de-Q'ing.

  • PDF

Gamma-ray 무기 연구 (A Study of Gamma-ray Weapon)

  • 한동윤
    • 한국군사과학기술학회지
    • /
    • 제20권1호
    • /
    • pp.72-80
    • /
    • 2017
  • Gamma-ray has some advantages as a weapon: it has the ability to transmutate matter, high penetrability through materials, and it is very harmful to living things. So it is worth to study the features of gamma-ray weapon in order to utilize it. Such abilities were simulated on the basis of Monte Carlo simulation program GEANT4. For the simulation conceptual design of gamma-ray weapon was conducted. High energy electrons, which were necessary for the high energy gamma-rays, were produced by linear electron accelerator, of which the parameters were derived from the Pohang Light Source(PLS-II). Gamma-rays were get by bremsstrahlung mechanism. The spectra of gamma-rays, that were measured at distances of 500 m, 1000 m, 1500 m and 2000 m, were gained by GEANT4.

Ultrasoft X-ray의 Escherichia coli균과 plasmid DNA에 대한 영향 (The Effects on Escherichia coli and Plasmid DNA Using Ultrasoft X-ray)

  • 전선미;김영민;김도만;김도원;윤화식
    • KSBB Journal
    • /
    • 제15권1호
    • /
    • pp.84-87
    • /
    • 2000
  • 포항 선형 가속기로부터 얻은 ultrasoft X-선이 대장균의 돌연변이 유도와 plasmid DNA 변이에 주는 영향을 알아보았다. 빔을 조사함에 따라 supercoil 형태의 plasmid DNA가 relaxed 형태로 변하고, 그후 선형으로 변해 감을 확인하였다. 빔을 조사한 plasmid DNA를 E. coli에 형질전환하여 $\beta$-galactosidase의 돌연변이 균을 분리하였고, 빔을 직접 조한 E. coli균으로부터도 $\beta$-galactosidase의 돌연변이 균을 얻었다. 변이된 plasmid DNA와 변이 대장균들의 plasmid DNA의 염기 부분을 변화를 확인하였으며 이 빔에 의해 주로 변이가 일어나는 부분이 있음을 알았다.

  • PDF

LIGA공정을 이용한 정밀 고분자 광도파로 제작 (Fabrication of Polymeric Optical Waveguide by LIGA)

  • 김진태;김병철;최춘기;윤근병;정명영
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.997-1006
    • /
    • 2003
  • LICA technique evolved as a basic fabrication process fur micro-structure. The present report deals with the basic technological features in the sequence of the LIGA technique such as deep x-ray lithography(DXRL), electroplating, and moulding processes at Pohang Light Source (PLS). We designed 3-D structured master for fabrication of polymeric optical wavegude and manufactured polymeric optical wavegude with the same using hot embossing process. Polymeric optical waveguide could be produced with ${\pm}$ 1 $\mu\textrm{m}$ accuracy and good surface roughness.

X-ray 식각된 PMMA의 다양한 현상조건에 따른 현상특성 (Development Characteristics of PMMA fabricated by X-ray Lithography in Various Development Conditions)

  • 김윤호;박준식;이인규;박순섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.284-287
    • /
    • 2004
  • Micro-structures fabricated by X-ray lithography are largely affected by doses, development conditions and other factors. For these reasons, PMMA development rates and its surface profiles under various development conditions were obseued. Development rates were measured in the rage from 1 to 6 $kJ/cm^3$ using the 9C1 white beamline of Pohang light source(PLS). In this experiment, we observed that development rates of stacked PMMA sheet using Si filter were relatively higher than that of not using Si filter. Furthermore, development rates in condition with the acoustic agitation(1 MHz, 3.67 $W/cm^3$) were twice than that in dipping condition with $35^{\circ}C$ developer considering the PMMA sheets-substrate bond strength

  • PDF

Synthesis of Synchrotron Radiation-induced Gold Nanoparticles as Radiosensitizer in Radiotherapy

  • Oh, Se An;Park, Jae Won;Kim, Seong Hoon;Kim, Sung Kyu;Yea, Ji Woon;Lee, Su Yong;Kang, Hyon Chol
    • Journal of the Korean Physical Society
    • /
    • 제73권11호
    • /
    • pp.1744-1749
    • /
    • 2018
  • This study investigated the feasibility of synthesizing GNPs using synchrotron radiation X-ray for use as a radiosensitizer in radiotherapy, and examined the morphology of the GNPs. Different concentration ratios of 4-mM gold precursor aqueous solution and 4-mM $NaHCO_3$ were mixed. This gold precursor aqueous solution was continuously irradiated with synchrotron radiation in the 4B X-ray microdiffraction beamline of Pohang Light Source (PLS)-II in Korea. The SEM, EDS, TEM, and XRD spectra of the GNPs synthesized using the synchrotron radiation were investigated. The GNPs synthesized using the synchrotron radiation were nanocrystals predominantly in the (111) direction of the face-centered cubic structure. We found that the shape of the gold nanoparticles was icosahedron at the molar concentrations of 0.25 mM:0.25 mM and 0.5 mM:0.5 mM mixed with 4 mM $HAuCl_4{\cdot}3H_2O$ and 4 mM $NaHCO_3$ solutions.

Charge Redistribution of Pt-based Alloys

  • Lim, K.Y.;Chung, Y.D.;Kwon, S.Y.;Lee, Y.S.;C.N.Whang;Y.Jeon;Park, B.S.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.171-171
    • /
    • 1999
  • We studied the charge redistribution in the Pt-M (M=Cu, Co) alloys by X-ray Absorption Near Edge Spectroscopy(XANES) and X-ray Photoelectron Spectroscopy(XPS). These analysis tools provide us information about the charge transfer in the valence band of intermetallic bonding. The samples were prepared by arc-melting method. After annealing this samples in vacuum for several hours, we cold get the ordered samples, which were confirmed with XRD analysis. the core and valence level energy shift in these system were investigated by Mg $K\alpha$(1253.6eV) x-ray source for Pt-Co alloys and monochromatized Al $K\alpha$ (1486.6eV) for Pt-Cu alloys. Pt L2, L3-edge, and Cu, Co K-edge XANES spectra were measured with the total electron-yield mode detector at the 3Cl beam line of the PLS (Pohang light source0. from the changes of White line (WL) area and the core level shifts of the each metal sites, we can obtain the information about the electrons participating in the intermetallic bonding of the Pt-Cu and Pt-Co alloys.

  • PDF

X-ray Absorption Near-edge Studies of Au1-xPtx alloys

  • Y.D. Chung;Lim, K.Y.;Lee, Y.S.;C.N.Whang;Park, B.S.;Y.Jeon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.164-164
    • /
    • 2000
  • Since Au-Pt alloys have various atomic structures depending upon composition and annealing temperature, it is very interesting to investigate the electronic structures of alloys. We studied the changes of the electronic structure I the Au-Pt alloys by x-ray absorption near edge spectroscopy (XANES). Two kinds of Au-Pt alloy samples were prepared by arc melting methods and ion-beam-mixing technique. The Pt L2, 3-edge and Au L2, 3-edge X-ray absorption spectra (XPS) were measured with the electron yield mode detector at the 3C1 beam line of the Pohang Light Source (PLS). It was found that there was a substantial decrease in the area of the Pt L2, 3 white lines compared with that of pure Pt. The observed decrease in white line area was attributed to an increase in the number of pure Pt. The observed decrease in white line area was attributed to an increase in the number of 5d-electrons at the Pt site upon alloy formation. However, the Au L2, 3 edge spectra for Au-Pt alloys are all similar to that of pure Au. This implies that the 5d hole count of Au is not changed by alloy formation with Pt.

  • PDF